ML19290F074
| ML19290F074 | |
| Person / Time | |
|---|---|
| Site: | Crystal River |
| Issue date: | 02/08/1980 |
| From: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Hancock J FLORIDA POWER CORP. |
| References | |
| NUDOCS 8003180054 | |
| Download: ML19290F074 (2) | |
Text
/
'o UNITED STATES
?,7, NUCLEAR REGULATORY COT.;T.;lSSION
.; 4.tf([', 5
, y.
j E
REGION !!
r,4, 2 101 Mt.RIETTA ST., N Vi., SUITE 3100 o
g gv
/
AT LANTA, G eor GI A 30303 In Reply Refer To:
FEB 6 1930 RII:JPO
(%___3022 50- -
Florida Power Corporation Attn:
J. A. Hancock, Director Nuclear Operations P. O. Box 14042, Mail Stop C-4 St. Petersburg, FL 33733 Gentlemen:
1 The enclosed IE Bulletin No. 80-04, is forwarded for action. A written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, rr-M James P. O'Reilly 6
Director
Enclosures:
l.
Most Recently Issued i
IE Bulletins
- f I
t
.f.
I l.
80 031 scosy
FEB
- p-Florida Power Corporation.
cc w/ enc 1:
D. C. Poole Nuclear Plant Manager Post.0ffice Box 1240 Crystal River, Florida 32629 s
e e
v
.=e4eG i
e we %
ee
.e
.....~,,,e,
l l
1 2
UNITED STATES SSINS No..
6820 NUCLEAR REGULATLhY COMMISSION Accessions No.:
OFFICE OF IhSPECTICN AND ENFORCEMENT 7910250504 WASHINGTON, D.C.
20555 February 8,1980 IE Bulletin No. 80-04 ANALYSIS OF A PWR MAIN STEAM LINE BREAK WITH CONTINUED FEEDWATER ADDITION Description of Circumstances:
Virginia Electric and Power Co. submitted a report to the Nuclear Regulatory Commission dated September 7, 1979 that identified a deficiency in the original analysis of containment pressurization as a result of reanalysis of steam line break for North Anna Power Station, Units 3 and 4.
Stone and Webster Engineering Corporation performed a reanalysis of containment pressure following a main steam line break and determined that, if the auxiliary feedwater system continued to supply feedwater at runout conditions to the steam generator that had experienced the steam line break, containment design pressure would be exceeoed in approximately 10 minutes. The long term blowdown of the water supplied ander runout conditions by the auxiliary feedwater system had not been considered in the earlier analysis.
On October 1, 1979, the foregoing information was provided to all holders of operating licenses and construction permits in IE Information Notice No. 79-24.
The Palisades facility did an accident analysis review pursuant to the information in the notice and discovered that with offsite power available, the condensate pumps would feed the affected generator at an excessive rate.
This excessive feed was not considered in the analysis for the steam line break accident.
On January 30, 1980, Maine Yankee Atomic Power Company informed the NRC of an error in the main steam line break analysis for the Maine Yankee plant.
During a reciew of the main steam line break analysis, for zero or low power at the end ol' core life, the licensee identified an incorrect postulation
+ hat the startup feedwater control valves would remain positioned "as is" during the transient.
In reality, the startup feedwater control valves will ramp to 80% full open due to an override signal resulting from the low steam generator pressure reactor trip signal. Reanalysis of the event shews the opening of the startup valve and associated high feedwater addition to the affected steam generator would cause a rapid reactor cooldown and resultant return-to power, a condition outside the plant design basis.
Actions to be Taken by the Licensee:
For all pressurized water power react reactors listed in Enclosure 1:
DUPLICATE DOCUMENT 1.
Review the containment pressure i potential for containment overpre Entire doctament previously entered into system under:
[