Text

c#

UNITED STATES

.

-

NUCLEAR REGULATORY COMMISSION

f

j

REGION 1

f

$31 PARK AVENUE

KING OF PRUSSIA. PENNSYt.VANI A 19408

20 g

Docket Nos. 50-245

50-336

Northeast Nuclear Energy Company

ATTN:

Mr. W. G. Counsil

Vice President - Nuclear

Engineering and Operations

P. O. Box 270

Hartford, Connecticut

06101

Gentlemen:

Subject:

Combined Inspection 50-245/79-03 and 50-336/79-03

This refers to the inspection conducted by Mr. G. P. Yuhas of this

office on February 12-15, 1979 of activities authorized by NRC License

Nos. DPR-21 and DPR-65 and to the discussions of our findings held by

Mr. Yuhas with Mr. J. F. Opeka and other members of your staff at the

conclusion of the inspection, and to a subsequent telephone discussion

between Mr. Yuhas and Mr. J. F. Opeka on February 21, 1979.

Areas examined during this inspection are described in the Office of

Inspection and Enforcement Inspection Report which is enclosed with this

letter. Within these areas, the inspection consisted of selective

examinations of procedures and representative records, interviews with

personnel. measurements made by the inspector, and observations by the

inspector.

Our inspector also verified the steps you have taken to correct the

items of noncompliance brought to your attention in letters dated June

14, 1978 and August 11, 1978. We have no further questions regarding

your action at this time.

In addition, our inspector examined those activities conducted under

your licenses relating to the subject covered in your letter to Mr.

Boyce H. Grier, Director, USNRC, Region 1, dated December 18, 1978. We

have no further questions regarding this matter.

Based on the results of this inspection, it appears that one of your

activities was not conducted in full compliance with NRC requirements,

as set forth in the Notice of Violation, enclosed herewith as Appendix

A.

This item of noncompliance has been categorized into the levels as

2229

149

79061502o7

.

.

,

Northeast Nuclear Energy

2

Company

described in our correspondence to you dated December 31, 1974.

This

notice is sent to you pursuant to the provisions of Section 2.201 of the

NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201 requires you to submit to this office, within twenty (20)

days of your receipt of this notice, a written statement or explanation

in reply including:

(1) corrective steps which have been taken by you

and the results achieved; (2) corrective steps which will be taken to

avoid further items of noncompliance; and (3) the date when full compli-

ance will be achieved.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part

2, Title 10, Code of Federal Regulations, a copy of this letter and the

enclosed inspection report will be placed in the NRC's Public Document

Room.

If this report contains any information that you (or your contractor)

believe to be proprietary, it is necessary that you make a written

application within 20 days to this office to withhold such infonnation

from public disclosure. Any such application must be accompanied by an

affidavit executed by the owner of the information, which identifies the

document or part sought to be withheld, and which contains a statement

of reasons which addresses with specificity the items which will be

considered by the Commission as listed in subparagraph (b) (4) of Section

2.790. The information sought to be withheld shall be incorporated as

far as possible into a separate part of the affidavit.

If we do not

hear from you in this regard within the specified period, the report

will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be

pleased to discuss them with you.

Sincerely,

'

0

'

George H. Smith, Chief

Fuel Facility and Materials Safety

Branch

Enclosures:

1.

Appendix A. Notice of Violation

2.

Office of Inspection and Enforcement Combined Inspection

Report Numbers 50-245/79-03 and 50-336/79-03

2229

150

.

.

,

Northeast Nuclear Energy

3

Company

cc w/encls:

J. F. Opeka, Station Superintendent

D. G. Diedrick, Manager of Quality Assurance

J. R. Himelwright, Licensing Safeguards Engineer

A. Z. Roisman, Natural Resources Defense Council (Without Report)

2229

151