APPENDIX A NOTICE OF VIOLATION General Electric Company License No. SNM-1097 Based on the results of the NRC inspection conducted on December 5-8, 1978, it appears that certain of your activities were not conducted in full compliance with NRC requirements as indicated below.

These items have been categorized as described in our correspondence to you dated December 31, 1974.

Condition 9 of the license requires that licensed material be used in accordance with statements, representations and conditions of Appendix A, as contained in the licensee's application.

Appendix A, Section 4.1 requires that operations and activities shall be directed by the designated area manager who shall establish written operating procedures. Written operating procedure, PROD No. 10.05, Vaporization, paragrap!. 3.2.9, of the Equipment Operating Instruction requires that the main line block valve be closed af ter the nitrogen purge.

Contrary to the above, the main line block valve was not closed causing an accidental release of special nuclear material on December 3, 1978.

This is an infraction.

7903 060 6 t *]