ML19284A489
| ML19284A489 | |
| Person / Time | |
|---|---|
| Site: | 07001113 |
| Issue date: | 12/21/1978 |
| From: | Sutherland J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Alkema R GENERAL ELECTRIC CO. |
| Shared Package | |
| ML19284A490 | List: |
| References | |
| NUDOCS 7903060615 | |
| Download: ML19284A489 (2) | |
Text
,
M
'~T~ 5 )
W
}&,
pm af C UNITED STATES NUCLEAR REGULATORY COMMISSION 3
,og 7
g REGION 11 g
).g g
C 101 M ARIETT A sTR E ET, N.W.
[
ATL ANT A, GEORGI A 30303 o,
t p
y..s -..."
DEC %1IWi@
In Reply Refer To:
RII:JBK 70-1113/78-23 General Electric Company Attn:
Mr. R. J. Alkema Wilmington Manufacturing Department P. O. Box 780 Wilmington, North Carolina 28401 Gentlemen:
This refers to the inspection conducted by Mr. J. B. Kahle of this office on December 5-8, 1978, of activities authorized by NRC License No. SNM-1097 for the Wilmington Manufacturing Department facility, and to the discussion of our findings held with Mr. L. A. Sheely at the conclusion of the inspection.
Areas examined during the inspection and our findings are discussed in the enclosed inspection report.
Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.
During the inspection, it was found that certain activities under your license appear to be in noncompliance with NRC requirements.
This item and references to pertinent requirements are listed in the Notice of Violation enclosed herewith as Appendix A.
This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, a written statement or explanation in reply including:
(1) corrective steps which have been taken by you, and the results achieved; (2) corrective steps which will be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
If this report contains any information that you (or your contractor) believe to be proprieta ry, it is necessary that you make a written application within 20 days to this of fice to withhold such information f rom public disclosure.
Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
7903 060 b\\'S
DEC 21 1979 General Electric Company Should you have any questions concerning this letter, we will be glad to discuss them with you.
Sincerely, k
Yi M
(
t' k T. Sutherland, Chief Fuel Facility and Materials Safety Branch
Enclosures:
1.
Appendix A, Notice of Violation 2.
Inspection Report No. 70-1113/78-23 cc w/ encl:
Mr. A. L. Kaplan, Manager Licensing and Compliance Audits General Electric Company Mail Code J-26 P. O. Box 780 Wilmington, North Carolina 28401 Mr. C. M. Vaughan, Manager Nuclear Materials Management Mail Code K-88 P. O. Box 780 Wilmington, North Carolina 28401