Amend 22 to License DPR-6,changing Provisions in Section 6 of Tech Specs to Reflect Revised Plant Organizational Structure Which Conforms to ANSI N18.7-1976
ML19282A666
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
(DPR-06-A-022, DPR-6-A-22)
Issue date: 01/30/1979
From: Ziemann D
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19282A663 List:
References
FOIA-80-162, TASK-13-01, TASK-13-1, TASK-RR NUDOCS 7903050436
Download: ML19282A666 (5)


Text

.

O UNITED STATES 4,'g C

p NUCLEAR REGULATORY COMMisslON y*

WASHINGTON. D. C. 20555 j

{

E O

49.....,o CONSUMERS POWER COMPANY DOCKET NO. 50-155 BIG ROCK POINT NUCLEAR PLANT AMENDMENT TO FACILITY OPERATING LICENS' Amendment No. 22 License No. DPR-6 1.

The Nuclear Regulatory Comission (the Comission) has found that:

The application for amendment by Consumers Power Company (the A.

licensee) dated December 27, 1978, as supplemented by letter dated January 12, 1979, complies with the standards and require-ments of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations cf the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part m.

51 of the Commission's regulations and all applicable requirements have been satisfied.

1 7003050 %54

. Accordingly, the license is amended by changes te the Technical 2.

Specifications as indicated in the attachment to this license amendmentandparagraph2.C(2)ofFacilityOperatingLicenseNo.

DPR-6 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Aopendix A, as revised through Amendment No. 22, are bereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

This license amendment is effective as of the date of its issuance.

3.

FOR THE NUCLEAR REGULATORY COMMISSION UbvvA Dennis L. Ziemann, ief Operating Reactors Branch #2 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance:

January 30, 1979

ATTACHMENT TO LICENSE AMENDMENT NO. 22 FACILITY OPERATING LICENSE NO. DPR-6 DOCKET NO. 50-155 Revise Appendix A Technical Specifications by removing the pages identi-fied below and inserting the enclosed pages. The revised pages include the captioned amendment number and contain vertical lines indicating the area of change.

REMOVE INSERT 10-3 10-3 10-5 10-5

CCNStMERS PC'"IR CCfGAT?

Plant Organization Generatins Plant CA -

Superintendent-Off Site Nuclear (a) i T'"t RevieV C0~~'ttee CA Sutt l____.-.

' '~

"'ec'~' cal

~

Eee1-"

.* -te=ance Operatic =s Superistendent Superintendent Physicist Superistanden; SQL (b) (d)

(d)

The fonoving cther disciplines, as identified by ANSI Operatic s A.

318.7-1976/ANS-3.2, vill be represented by qualified per-Supervisor sonnel who vill report at the discretica of the Generating SCL (c)

Plant Superintendent-Huclear:

1.

Nuclear Pcver Plant Mechanical, Electrical and Electronic Syste=s Shift 2.

Nuclear Engineering Supervisers SCL 3

Chemistry and Radicchemistry h.

Radiation Protectic.n (Reports to Health Physicist)

A single individual may be qualified and perform in =cre than one discipline.

3.

The Security Perce vill be supervised as described in the

~

Plant Security Plan.

C.

Qualitf Control Activities vill be in accordance with the Censumers Power Quality Assurance Program Policies.

Responsible for the Plant Fire Protection Program (a)

The Operations Superintendent need not hold an SOL provided he meets the (b) other requirements of 6.3.1 of these Specifications and the position of

" Operations Supervisor" is fined. Under these conditions, the Operations Supervisor shan be responsible for directing the activities of licensed operators.

This position need not be fined if the Operations Superintendent holds an (c)

However, when the OperationsSupervisor position is fined, that indi-SOL.

vidue.1 shall hold an SQL.

(d) The Operations and Maintenance Superintendents' positions say be ecsbined When this occurs, the operations supervisor position under one individual.

vin be fuled.

(SCL - Senior Operator Licensee)

Fig.:re 6.2-2 Amendment No. $, J2, J7, JS, 22 10-3

6.li TilAINING 6.h.1 A retraining and replacement training progrum for the plant staff shall be maintained under the direction of the Plant Superintendent and shall meet or exceed the requirements and recommendations of Section 5 5 of ANSI N18.1-1971 and Appendix "A" of 10 CFR, Part 55

6. la. 2 A training program for the Fire Brigude shall be maintained under the direction of the Plunt Training Coordia.utor und uholi meet or exceed the requirementu of Section 27 of the NFl'A Code-1975 except for Fire 11rigade training sessions which shall be held at least quarterly.

6.5 REVILV AND AUDIT 6.5.1 PLANT REVIEW COMMITTEE (PRC) 6.5 1.1 The Plant Review Committee (PRC) shall function to advise the Plant Superintendent on all matters related to nuclear safety.

6.$.1.2 00MPOSITIDL The PRC shall be composed of the:

Chairman: Plant Superintendent l

Member:

Operations Superintendent" Member:

Technical Superintendent l

Member:

Maintenance Superintendent

  • Member:

Operations Supervisor Member:

Instrument and Control Supervisor Member:

Reactor Engineer Member:

IIcalth Physicist Member:

Shift Supervisor Member:

Maintenance Engineer "Lihen these positions are combined in accordance with the Plant Organization, Figure 6.2-2, the individual holding both positions serves as a single voting member of the PRC.

6.5.1.3 AT.TERNATES Alternate members shall be appointed in writing by the PRC Chairman to serve on a temporary basis; however, no more than two alternates shall participate in PRC activities at any one time.

Anendment No. 9, J7, J7, JS, 22 10-5