Tb n aaa,
- ju o
o UNITED STATES S Y "., >
',,g NUCLEAR REGULATORY COMMISSION 3.'
REGION I 9, '
U[
631 PARK At'ENUE
%, ' %./
o KING OF PAUSSIA, PEN %SYLVANIA 19406
+....
Docket Nos. 50-317
'5EP 27 un 50-318 Baltimore Gas and Electric Company ATTN:
Mr. A. E. Lundvall, Jr.
Vice President, Supply P. O. Box 1475 Baltimore, Maryland 21203 Gentlemen:
The enclosed Bulletin 79-24 is forwarded to you for action. Written responses are required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, f
An
_ Boyce H. Grier Director
Enclosures:
1.
IE Bulletin No. 79-24 2.
List of IE Bulletins Issued in the Last Six Months cc w/encls:
R. M. Douglass, Manager, Quality Assurance L. B. Russell, Chief Engineer W. Gibson, General Supervisor, Operational QA R. C. L. Olson, Senior Engineer K. H. Cebra, Principal Engineer 1185 091 7910180d h h
ENCLOSUREJ Accession No. 7908220114 SSINS No:
6820
'JNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHI!1GTON, D.C.
20555 IE Bulletin No. 79-24 Date:
Septer Ser 27,.1979 Page 1 of 2 FR0 ZEN LINES Summary:
On January 3, 1979, an unusual event occurred at Davis-Besse, Unit 1.
The event involved the freezing of the water in a portion of the high pressure coolant injection (HPCl) system recirculation line that is common to both high pressure coolant injection pumps.
The line was not thawed until January 5,1979, and the event was not reporteo to NRC until March 12, 1979.
In addition, over the past 'ive years, there have been several events involving frozen instrument and samp, g lines.
Description of Circumstances:
The condition was discovered on January 3, 1979, while the reactor was operating at approximately 96 percent power.
During a monthly surveillance test of the HPCI pumps, there was no flow through the recirculation line from the pump discharge to the Borated Water Storage Tank (BWST).
Investigation revealed that water in a portion of the line exposed to the outside weather was frozen.
This portion of the line to the BWST is common to both HPCI pumps.
The line has redundant heat tracing (a heated wire to prevent freezing); it is insulated; and it has a low-temperature alarm system to warn of freezing conditions.
Water in the line froze apparently because of prolonged sub-freezing temperatures and a defect in the insulation.
There was no apparent malfunction of the heat tracing or temperature alarm circuits, although the temperatu~ sensing elements are located in an area not exposed to the coldest temperaturt....ditions.
This recirculat Mn line serves two purposes:
One is to provide a flow path far surveillance testing, and the other is to provide a minimum flow path to prevent possible damage to the pump in the event it is operated against a closed discharge valve or a reactor coolant system pressure greater than the maximum discharge pressere of the pump (approximately 1600 psig).
In the initial review of the event on Jr-"--"
- "-a~aa canel" dad that the pumps were still operable with no immediate action was taken to thaw t January 5, 1979, the line was thawed an Was successfully completed.