ML19274G208
| ML19274G208 | |
| Person / Time | |
|---|---|
| Site: | Marble Hill |
| Issue date: | 07/26/1979 |
| From: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Coughlin J PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA |
| References | |
| NUDOCS 7908300425 | |
| Download: ML19274G208 (1) | |
Text
M MGg#'o UNITED STATES
!\\
NUCLEAR REGULATORY COMMISSION IlC
$ d 3,,f ' E PEGION lli n
"/.
[
799 ROOSEVELT ROAD
(
o 9
%, ' \\/
s GLEN E LLYN, ILLINolS 60137
- ...+
Jyl, 2 61979 Docket No. 50-546 Docket No. 50-547 Iublic Service of Indiana dTTN:
Dr. James Coughlin Vice President, Nuclear 1000 East Main Street Plainfield, IN 46168 Gentlemen:
The enclosed IE Bulletin No. 79-17 is forwarded to you for information.
No written response is required. However, the potential corrosion be-havior of safety related systems as it regards your plant over the long term should be taken into consideration.
If you desire additional information concerning this matter, please contact this office.
Sincerely, AY James G. Keppler Director
Enclosure:
IE Bulletin No. 79-17 cc w/ encl:
Mr. R. M. Brown, Construction Project Superintendent Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR NSIC TIC LeBoeuf, Lamb, Leiby & MacRae 2031 050 79083004'df
UNITED STATES NUCLE AR REGULATORY COMMISSION
" S & M si'I1.*R 51'812 "
v 0
July 26*, 19791 i,
IE Bulletin.No. 79-17
?
PIPE [ CRACKS IN STAGNANT BORATED WATER SYSTEMS AT PWR PLANTS t
Description of Circumstances:
During the period of November 1974 to February 1977 a number of cracking incidents have been experienced in safety-related stainless steel pipirg systems and portions of systems which contain oxygenated, stagnant or essentially stagnant borated water. Metallurgical investigations revealed these cracks occurred in the weld heat affected zone of 8-inch to 10-inch type 304 material (schedule 10 and 40), initiating on the piping I.D. surface and propagating in either an intergranular or transgranular mode typical of Stress Corrosion Cracking. Analysis indicated the probable corrodents to be chloride and oxygen contamination in the affected systems. Plants affected up to this time were Arkansas Nuclear Unit 1 R. E. Ginna H.B. Robinson Unit 2 Crystal River Unit 3, San Onofre Unit 1, and Surry Units 1 and 2.
The NRC issued Circular 76-06 (copy attached) in view of the apparent generic nature of the problem.
During the refueling outage of Three Mile Island Unit I which began in February of this year, visual inspections disclosed five (5) through-wall cracks at velds in the spent fuel cooling system piping and one (1) at a weld in the decay heat removal system. These cracks were found as a result of local boric acid build-up and later confirmed by liquid penetrant tests. This initial identification of cracking was reported to the NRC in a Licensee Event Report (LER) dated May 16, 1979. A preliminary metallurgical analysis was performed by the licensee on a section of cracked and leaking veld joint from the spent fuel cooling system.
The conclusion of this analysis was that cracking was due to Intergranular Stress Corrosion Cracking (IGSCC) originating on the pipe I.D.
The cracking was localized to the beat affected zone where the type 304 stainless steel is sensitized (precipitated carbides) during velding. In addition to the main through-wall crack, incipient cracks were observed at several locations in the veld beat affected zone including the weld root fusion area where a miniscule lack of fusion had occurred. The stresses responsible for cracking are believed to be primarily residual velding stresses in as much es the calculated applied stresses were found to be less than code design limits. There is no conclusive evidence at this time to identify those aggressive chemical species which promoted this IGSCC attack. Further analytical efforts in this area and on other system velds are being pursued.
2031 051 DUPLICATE DOCUMENT Entire document previously entered into system under:
ANO No. of pages:
.