05000368/LER-1979-048-03, /03L-0 on 790703:startup Channel Excore Nuclear Log Count Ratemeter on Remote Shutdown Indicated Incorrectly During Mode 1 Operation.Cause Not Stated. Feedback Wiper Arm Cleaned

From kanterella
(Redirected from ML19274F815)
Jump to navigation Jump to search
/03L-0 on 790703:startup Channel Excore Nuclear Log Count Ratemeter on Remote Shutdown Indicated Incorrectly During Mode 1 Operation.Cause Not Stated. Feedback Wiper Arm Cleaned
ML19274F815
Person / Time
Site: Arkansas Nuclear 
Issue date: 07/31/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19274F812 List:
References
LER-79-048-03L, LER-79-48-3L, NUDOCS 7908060472
Download: ML19274F815 (1)


LER-1979-048, /03L-0 on 790703:startup Channel Excore Nuclear Log Count Ratemeter on Remote Shutdown Indicated Incorrectly During Mode 1 Operation.Cause Not Stated. Feedback Wiper Arm Cleaned
Event date:
Report date:
3681979048R03 - NRC Website

text

.

NRC FORM 366 U. S. NUCLE AR REGUL ATORY COMMISSION

(?FF)

LICENSEE EVENT REPORT EXHIBIT A CONTROL BLOCO l l l l l l lh (PLE ASE PRINT OR TYPE ALL REOUtREO INFORMATIONI I

6 lo lil l Aj R l A j Nj 0 } 2 lgl 0 l0 l -[0 l 0 l 0l 0l 0 l-l 0 l0 gi l1 l 1 l1 l 1 lg[ l lg 7

8 9 LICENSEE CODE 14 15 LICE NSE NvubEH 2b 26 tac t %E IvPs J0

  • al C A T bil CON'T loI'I s"'I."CI (L_j@l0 l 5 l0 l0 l 0 l3 l 618 l@l0 l 71013 l 7 l 91@l0 F 13 l11 7l 9l@

7 8

60 6'

LOCsf r NUM6E R W

6'>

EVENT Dart le 75 84FPOMr O ArE 80 EVENT DESCRIPTION AND PROO AOLE CONSEQUENCES h l o 121 f Durine Mode 1 operation, it was identified that the Startup 1

1 channel excore Nuclear Log Count Ratemeter, 2JI-9000, on o

2 Io141I the remote shutdown panel indicated incorrect 1v.

The electrical 1

Lpower to the indicator dropped out at sctuoint. 10-6% however, 1

e s

Io 16 I I the pointer did not go to zero.

J i There have been no similar occurrences.

1 o

i

[ o le i 1 This occurrence reportable per T.S.6.9.1.9b.

80 l

7 4

'l C DE L

E Suht E

t A%NE NT LUDE t

DE I I l Cl@ LEJ@ LEj@ l IlN l S l T R l Ul@ J. @ p_j @

[,lsl 9

m ii u

o n

m SEQut N ri A:

CCL'..n b f M E nt "On r RE v eSioN LE a kO EVENrvEA4 AEPORr %

COLi

'vPt AC

@,af?t";

I 719 I l--J l 01 al 8 I M

i01 31 O

l _]

[ 0_l 2

n u

a v

2.

x

.o u

re E A rO ONP A 1 M rC HOLR5 59 air D FO 69 PPL VANtFACit ER LSj@ll.j@

W@

l.__Zj@

l0 l 0l010l L.' J @

[_NJ@

[_NJ@

l S l 1l8 l 5l@

JJ 34 3-a au JW 43 4

4j 43 a4 4,

Ct.USE DE SCR.PTION AND CCRREC flVE ACTIONS h i

- IThe indicating instrument feedback wiper arm was cleaned.

5 iiI j ithe indicator was exercised throuchout its rance.

The i

I remote shutdown meter was returned to service within ten i

i Ihours, meeting the requirements of Action Statement I

i 3

m lT.S.3.3.3.5a.

's t'A'!' ?

or-E., s1Arus @

",'s'CZi '

u uoma o,co.E2, o,xn,,noN li l s I LBJ@ l 0 l 51 d@lPwr Escalation l W@l NA l

" A!riv iy CO' T E N r

" Test

  • c sa AuovNT oF ACDVirY @ l (Out*oN OF HELE ASE @

mELE Asto or HELE AsE LZ_J @ LZ_J@l NA l

NA c

l PE usoNNEl E x Pos " E s ao otsca.,ncN @

nuo.E.

rvet l010l0l@ y @l NA i /

l EnsowE'L.N;u' lits su otsCaierioN@

Nuvu n fi~Ili0l010l@l NA l

7 8 9 ft 12 LOSS OF 04 OAM AGE 70 FAcetsrv PO tvPE DESCR PilON [Z.J@l NA i 9 l

7 M 9 10 PLBLICirY O

DESCRiPriON "C W WLY 155UED@l LEJ NA 1 lll[t[l[;;;;l 2

NAlW'E OF PREP ARER S

7 PHONE.

7 908060m