ML19259D106

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-17, Pipe Cracks in Stagnant Borated Water Sys at PWR Plants. No Action Required
ML19259D106
Person / Time
Site: Clinton  
Issue date: 07/26/1979
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Gerstner W
ILLINOIS POWER CO.
References
NUDOCS 7908300411
Download: ML19259D106 (1)


Text

ma acc t

[

oq'o, UNITED STATES

! j( _,,' %g' '7 [,g g

NUCLEAR REGULATORY COMMISSION

/ c REGION 111 799 ROOSEVELT ROAD ogv

/

ctEu Ettvu. ittinois soia7 JUL 2 61979 -

Docket No. 50-461 Docket No. 50-462 illinois Power Company ATTN:

Mr. W. C. Gerstner Executive Vice President 500 South 27th Street Decatur, IL 62525 Gentlemen:

The enclosed IE Bulletin No. 79-17 is forwarded to you for information. No written response is required. However, the potential corrosion behavior of safety related systems as it regards your plant over the long term should be taken into consideration.

If you desire additional information concerning this matter, please contact this office.

Sincerely, WS

^

(/ James G. Kepp er Director

Enclosure:

IE Bulletin No. 79-17 cc w/ enc 1:

Central Files Director, hM/DPM Director, NRR/ DOR PDR Local PDR NSIC TIC Mr. Dean Hansell, Office of Assistant Attorney General 2105

.548 7908300911

s UNITED STATES NUCLEAR REGUIATORY COMMISSION mcE LBiBEi3.^P "15818'*'"'

v July 26l, 1979'-

i IE Bulletin No. 79-17 PIPE [ CRACKS IN STAGNANT BORATED WATER SYSTDiS AT PWR PIANTS DeschiptionofCircumstances:

During the period of November 1974 to Feb uary 1977 a number of cracking incidents have been experienced in safety.-elated stainless steel piping systems and portions of systems which contain oxygenated, stagnant or essentially stagnant borated water. Metallurgical investigations revealed these cracks occurred in the weld heat affected zone of 8-inch to 10-inch type 304 material (schedule 10 and 40), initiating on the piping I.D. surface und propagating in either an intergranular or transgranular mode typical of ocress Corrosion Cracking. Analysis indicated the probable corrodents to be chloride and oxygen contamination in the affected systems. Plants affected up to this time were Arkansas Nuclear Unit 1, R. ". Ginna, H.B. Robinson Unit 2, Crystal River Unit 3, San Onofre Unit 1, and Surry Units 1 and 2.

The NRC issued Circular 76-06 (copy attached) in view of the apparent generic nature of the prublem.

During the refueling outage of Three Mile Island Unit I which began in February of this year, visual inspections disclosed five (5) through-wall cracks at welds in the spene fuel cooling system piping and one (1) at a weld in the decay heat removal system. These cracks were found as a result of local boric acid build-up and later confirmed by liquid penetrant tests. This initial identification of cracking was reported to the NRC in a Licensee Event Report (LER) dated May 16, 1979. A preliminary metallurgical analysis was performed by the licensee on a section of cracked and leaking weld joint from the spent fuel cooling system.

The conclusion of this analysis was that cracking was due to Intergranular Stress Corrosion Cracking (IGSCC) originating on the pipe I.D.

The cracking was localized to the beat affected zone where the type 304 stainless steel is sensitized (precipitated carbides) during welding. In addition to the main through-wall crack, incipient cracks were observed at several locations in the weld heat affected zone including the weld root fusion area where a miniscule lack of fusion had occurred. The stresses responsible for cracking are believed to be primarily residual welding stressss in as much as the calculated applied stresses were found to be less than code design limits. There is no conclusive evidence at this time to identify those aggressive chemical species which promoted this IGSCC attack. Further analytical afforts in this area and on other system velds are being pursued.

DUPLICATE DOCdMENT2105 34 9 Entire document previously entered into system under:

ANO No. of pages:

.