| | | Reporting criterion |
|---|
| 05000263/LER-1979-001, Forwards LER 79-001/03L-0 | Forwards LER 79-001/03L-0 | |
| 05000263/LER-1979-001-03, /03L-0 on 790110:during Normal Operation,Steam Leak Found in Elbow on Turbine Main Steam Bypass Header 1 Inch Drain Line to Condenser,Due to Erosion Caused by Steam & Water Flow of Restricting orifice,RO-2569 | /03L-0 on 790110:during Normal Operation,Steam Leak Found in Elbow on Turbine Main Steam Bypass Header 1 Inch Drain Line to Condenser,Due to Erosion Caused by Steam & Water Flow of Restricting orifice,RO-2569 | |
| 05000263/LER-1979-002, Forwards LER 79-002/03L-0 | Forwards LER 79-002/03L-0 | |
| 05000263/LER-1979-002-03, /03L-0 on 790118:during Normal Operation,Weekly Average Power Range Monitor Functional Scram Test Was Not Completed within Time Allowed.Caused by Personnel Error | /03L-0 on 790118:during Normal Operation,Weekly Average Power Range Monitor Functional Scram Test Was Not Completed within Time Allowed.Caused by Personnel Error | |
| 05000263/LER-1979-003, Forwards LER 79-003/01T-0 | Forwards LER 79-003/01T-0 | |
| 05000263/LER-1979-003-01, /01T-0 on 790301:containment Vent & Purge Isolation Valves Would Not Close During DBA-LOCA.Cause Unknown.Fisher Continential 18 & 20 Inch,Type 9220 Butterfly Valves Opening Is Administratively Controlled | /01T-0 on 790301:containment Vent & Purge Isolation Valves Would Not Close During DBA-LOCA.Cause Unknown.Fisher Continential 18 & 20 Inch,Type 9220 Butterfly Valves Opening Is Administratively Controlled | |
| 05000263/LER-1979-004-01, /01T-0 on 790313:shipping Cask Model B-2 Found W/ Two Missing Lid Bolt Nuts,Missing Inner Lid Gasket & Damaged Outer Lid Gasket.Caused by Inadequate Insp & Maint by Supplier.Cask Returned Empty | /01T-0 on 790313:shipping Cask Model B-2 Found W/ Two Missing Lid Bolt Nuts,Missing Inner Lid Gasket & Damaged Outer Lid Gasket.Caused by Inadequate Insp & Maint by Supplier.Cask Returned Empty | |
| 05000263/LER-1979-005-03, /03L-0 on 790315:results of Special Test of Safety Relief Valve Effects on Torus Indicated Possible Excessive Opening Delay Time.Caused by Improper Installation of Insulation on Valve 67F.Maint Procedure to Modified | /03L-0 on 790315:results of Special Test of Safety Relief Valve Effects on Torus Indicated Possible Excessive Opening Delay Time.Caused by Improper Installation of Insulation on Valve 67F.Maint Procedure to Modified | |
| 05000263/LER-1979-006-01, /01T-0 on 790317:during Recirculator Motor Generator Shutdown,Associated Field Breaker Failed to Trip. Caused by Metal Bead Fused to Arc Chute.Bead Removed,Breaker Tested & Returned to Svc | /01T-0 on 790317:during Recirculator Motor Generator Shutdown,Associated Field Breaker Failed to Trip. Caused by Metal Bead Fused to Arc Chute.Bead Removed,Breaker Tested & Returned to Svc | |
| 05000263/LER-1979-007-03, /03L-0 on 790318:valve Operability & Motor Current Check Signed Despite Current Outside Formula Spec.Caused by Misaligned Torque Switch.New Components Ordered | /03L-0 on 790318:valve Operability & Motor Current Check Signed Despite Current Outside Formula Spec.Caused by Misaligned Torque Switch.New Components Ordered | |
| 05000263/LER-1979-008-01, /01T-0 on 790323:one Trip Output Relay Failed to Initiate Trip in No 12 Recirculation Motor Generator Set Field Breaker Trip Logic.Caused by Contact Which Was Disengaged from Socket.Contact re-engaged in Socket | /01T-0 on 790323:one Trip Output Relay Failed to Initiate Trip in No 12 Recirculation Motor Generator Set Field Breaker Trip Logic.Caused by Contact Which Was Disengaged from Socket.Contact re-engaged in Socket | |
| 05000263/LER-1979-009-03, /03L-0 on 790404:steam Leak Found in 90 Degree Elbow in 1-inch Core Isolation Cooling Steam Supply Drain Pot Condenser Line.Caused by Erosion Due to High Velocity Steam from Leaking Valve.Hole Patched.Repairs Planned | /03L-0 on 790404:steam Leak Found in 90 Degree Elbow in 1-inch Core Isolation Cooling Steam Supply Drain Pot Condenser Line.Caused by Erosion Due to High Velocity Steam from Leaking Valve.Hole Patched.Repairs Planned | |
| 05000263/LER-1979-010-01, /01T-0 on 790426:informed by General Motors of Potential Diesel Generator Turbocharger Problem.Caused by Inadequate Design of Lube Oil Sys.Mod Being Developed | /01T-0 on 790426:informed by General Motors of Potential Diesel Generator Turbocharger Problem.Caused by Inadequate Design of Lube Oil Sys.Mod Being Developed | |
| 05000263/LER-1979-011, Forwards LER 79-011/03L-0 | Forwards LER 79-011/03L-0 | |
| 05000263/LER-1979-011-03, /03L-0 on 790529:no Min Flow in B Train Standby Gas Treatment Sys.Caused by Dilution Flow from Compressed Storage Not Isolated by BV-5.Replaced Positioner & Installed Filter in Cylinder Supply/Return Line | /03L-0 on 790529:no Min Flow in B Train Standby Gas Treatment Sys.Caused by Dilution Flow from Compressed Storage Not Isolated by BV-5.Replaced Positioner & Installed Filter in Cylinder Supply/Return Line | |
| 05000263/LER-1979-012, Forwards LER 79-012/03L-0 | Forwards LER 79-012/03L-0 | |
| 05000263/LER-1979-012-03, /03L-0 on 790702:during Reactor Core Isolation Cooling Sys Test,Governor end-bearing Temp Alarm Received & Bearing Exhibited High Vibration.Sys Inoperative.Caused by Turbine Oil Pump Drive Gear Failure.Gears Replaced | /03L-0 on 790702:during Reactor Core Isolation Cooling Sys Test,Governor end-bearing Temp Alarm Received & Bearing Exhibited High Vibration.Sys Inoperative.Caused by Turbine Oil Pump Drive Gear Failure.Gears Replaced | |
| 05000263/LER-1979-013, Forwards LER 79-013/03L-0 | Forwards LER 79-013/03L-0 | |
| 05000263/LER-1979-013-03, /03L-0 on 790708:motor Operator Failed,Rendering Torus Cooling Injection Valve Inoperable During Normal Operation.Caused by Failure of Motor Winding Due to Limit Switch Not de-energizing Motor.Switch Replaced | /03L-0 on 790708:motor Operator Failed,Rendering Torus Cooling Injection Valve Inoperable During Normal Operation.Caused by Failure of Motor Winding Due to Limit Switch Not de-energizing Motor.Switch Replaced | |
| 05000263/LER-1979-014, Forwards LER 79-014/03L-0 | Forwards LER 79-014/03L-0 | |
| 05000263/LER-1979-014-03, /03L-0 on 790709:water Leak Discovered in 1/2 Inch Instrument Line from Reactor Water Cleanup Sys Nonregenerative Heat Exchanger.Cause Not Determined.Leaking Line Isolated & Will Be Further Investigated & Repaired | /03L-0 on 790709:water Leak Discovered in 1/2 Inch Instrument Line from Reactor Water Cleanup Sys Nonregenerative Heat Exchanger.Cause Not Determined.Leaking Line Isolated & Will Be Further Investigated & Repaired | |
| 05000263/LER-1979-015, Forwards LER 79-015/03L-0 | Forwards LER 79-015/03L-0 | |
| 05000263/LER-1979-015-03, /03L-0 on 790712:discovered Steam Leak from Intermediate Pressure Feedwater Heater.Cause Undetermined. Temporary Patch Installed Pending Replacement of Heater Shell | /03L-0 on 790712:discovered Steam Leak from Intermediate Pressure Feedwater Heater.Cause Undetermined. Temporary Patch Installed Pending Replacement of Heater Shell | |
| 05000263/LER-1979-016-03, /03L-0 on 790731:turbine Tripped on Low Oil Pressure.Caused by Clogged Lube Oil Filter.Sys Drained, Inspected & Flushed | /03L-0 on 790731:turbine Tripped on Low Oil Pressure.Caused by Clogged Lube Oil Filter.Sys Drained, Inspected & Flushed | |
| 05000263/LER-1979-016, Forwards LER 79-016/03L-0 | Forwards LER 79-016/03L-0 | |
| 05000263/LER-1979-017, Forwards LER 79-017/03L-0 | Forwards LER 79-017/03L-0 | |
| 05000263/LER-1979-017-03, /03L-0:on 790806,steam Leak Observed on Feedwater Extraction Steam Line Drain 15A.Caused by Steam Erosion Through Wall of Steam Trap on Line.Trap Isolated Pending Repair or Replacement at Next Appropriate Outage | /03L-0:on 790806,steam Leak Observed on Feedwater Extraction Steam Line Drain 15A.Caused by Steam Erosion Through Wall of Steam Trap on Line.Trap Isolated Pending Repair or Replacement at Next Appropriate Outage | |
| 05000263/LER-1979-018, Forwards LER 79-018/03L-0 | Forwards LER 79-018/03L-0 | |
| 05000263/LER-1979-019, Forwards LER 79-019/03L-0 | Forwards LER 79-019/03L-0 | |
| 05000263/LER-1979-019-03, /03L-0:on 790923,ECCS Yarway Level Switches Indicated Falsely High Level & Would Not Have Tripped within Specified Settings.Caused by Effects of Leak Which Developed in Reactor Pressure Gauge During Normal Operation | /03L-0:on 790923,ECCS Yarway Level Switches Indicated Falsely High Level & Would Not Have Tripped within Specified Settings.Caused by Effects of Leak Which Developed in Reactor Pressure Gauge During Normal Operation | |
| 05000263/LER-1979-020-03, /03L-0:on 791030,reactor Core Isolation Cooling Isolation Temp Switch Found to Trip Above Allowable Setpoint.Caused by Setpoint Drift.Switch Replaced | /03L-0:on 791030,reactor Core Isolation Cooling Isolation Temp Switch Found to Trip Above Allowable Setpoint.Caused by Setpoint Drift.Switch Replaced | |
| 05000263/LER-1979-020, Forwards LER 79-020/03L-0 | Forwards LER 79-020/03L-0 | |
| 05000263/LER-1979-021-03, /03L-0:on 791119,during IE Bulletin 79-02 Evaluation,Snubber SS-31 Base Plate Expansion Anchor Bolt Safety Factor Found to Be Less than One.Caused by Inadequate Base Plate & Expansion Anchor Bolts | /03L-0:on 791119,during IE Bulletin 79-02 Evaluation,Snubber SS-31 Base Plate Expansion Anchor Bolt Safety Factor Found to Be Less than One.Caused by Inadequate Base Plate & Expansion Anchor Bolts | |
| 05000263/LER-1979-021, Forwards LER 79-021/03L-0 | Forwards LER 79-021/03L-0 | |
| 05000263/LER-1979-022, Forwards LER 79-022/03L-0 | Forwards LER 79-022/03L-0 | |
| 05000263/LER-1979-022-03, /03L-0:on 791213,during Normal Operation,Leak Discovered in 90-degree Elbow on 1-inch Condensate Line from Steam Supply to Recombiner Train Drain Trap.Caused by Erosion from Hot Steam Drains.Elbow Modified | /03L-0:on 791213,during Normal Operation,Leak Discovered in 90-degree Elbow on 1-inch Condensate Line from Steam Supply to Recombiner Train Drain Trap.Caused by Erosion from Hot Steam Drains.Elbow Modified | |
| 05000263/LER-1979-023, Updated LER 79-023/01T-1:on 800103,one Fuel Type Noted to Exceed Max Allowable Max Average Planar Linear Heat Generation Rate Value & Another as Improperly Programmed in Plant Computer.Caused by Inadequate Review | Updated LER 79-023/01T-1:on 800103,one Fuel Type Noted to Exceed Max Allowable Max Average Planar Linear Heat Generation Rate Value & Another as Improperly Programmed in Plant Computer.Caused by Inadequate Review | |
| 05000263/LER-1979-024-03, /03L-0:on 791220,during Normal Operation,Routine Operator Insp Revealed Steam Leak in 1-inch 90 Degree Elbow in Reactor Core Isolation Cooling Steam Line Drain to Condenser.Caused by Pinhole Failure of 3,000-lb Socket Weld | /03L-0:on 791220,during Normal Operation,Routine Operator Insp Revealed Steam Leak in 1-inch 90 Degree Elbow in Reactor Core Isolation Cooling Steam Line Drain to Condenser.Caused by Pinhole Failure of 3,000-lb Socket Weld | |
| 05000263/LER-1979-024, Forwards LER 79-024/03L-0 | Forwards LER 79-024/03L-0 | |