i TABLE 4.3-4 SEISMIC MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL CHANNEL CHANNEL FUNCTIONAL INSTRUMENTS AND SENSOR LOCATIONS CHECK CALIBRATION TEST 1.

Tria'xial Time-History Accelerographs

a. ACS-8001, Unit 1 Containment Base Slab, Elev, 335'**

NA R

SA

b. ACS-8002, Unit i Top of Containment Elev. 531 '6" NA R

SA 2.

Triaxial Peak Accelerographs

a. 2XR-8347, Containment Base Slab.

Elev. 336'6" NA R

NA

b. 2XR-8348, Primary Shield 0/5 Reactor Cavity, Elev, 366'3" NA R

NA

c. 2XR-8349, Top of Containment, Elev.

531 '6" NA R

NA 3.

Triaxial Response-Spectrum Recorders

a. 2XR-8350, Containment Base Slab, Elev, 335'6" (0/S Containment)

NA R

R

    • With Unit 1 control room indication ARKANSAS - UNIT 2 3/4 3-32 79110503 Y