ML19253A209

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-14 Re Description of Plans for Seismic Analyses of as-built Piping Sys
ML19253A209
Person / Time
Site: Calvert Cliffs  
Issue date: 07/31/1979
From: Lundvall A
BALTIMORE GAS & ELECTRIC CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 7908200108
Download: ML19253A209 (51)


Text

7M 4

1 t'

BALTIMORE GAS AN D ELECTRIC COMPANY GAS AND ELECTRIC BUILDING B ALTI M O R E, M A RY LAN D 21203 July 31, 1979 AnTHun E. LUN DVALL,Ja.

%CE P8ES' DENT Sumv Mr. Boyce H. Grier, Director Region I, Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19h06

Subject:

Calvert Cliffs Nuclear Power Plant Units Nos. 1 & 2, Docket Nos. 50-317 & 50-318 IE Bulletin No. 79-14 Seismic Analyses for As-Built Pinine Systems

Dear Mr. Grier:

IE Bulletin 79-lh requires a written report within 30 days describing our plans for verification of as-built piping systems. The following provides the information required by the Bulletin.

Piping systems to be included in the program have been identified and are listed in Attachment 1.

These have been sub-divided as necessary and categorized redundant /nonredundant and accessible / inaccessible.

Inaccessible systems or portions of systems are those in containment and in high radiation areas of the auxiliary building. For systems to be inspected, design documents have been listed (Attachments 2 through 8) and assembled for use by field personnel performing system inspections. Engin-eering information contained in these documents is summarized in Attachment 9

Insuection elements have been identified ( Attachment 10) and acceptance criteria developed, to provide the basis for a field inspection procedure.

Inspection teams at the plant have begun to walk down accessible systems of Unit 2 to verify and document as-built conditions.

Our Architect / Engineer, Bechtel Power Corporation vill compare these with the conditions of the design documentation.

Any instection element falling outside established tolerances will be evaluated to determine its effect upon system operability.

Our plans are to comulete the inspection described by item 2 of the Bulletin within the required 60 days for both Calvert Cliffs units.

For the insnection required by item 3 of the Bulletin, we plan to complete the program for Unit 2 within 120 days or prior to return to power following our refueling outage; for Unit 1, we plan to complete inspection on all accessible systems within the required 120 days, and on inaccessible systems during our next scheduled refueling outage in the spring of 1980.

Our bases for continuing the operation of Unit 1 and extending completion of this program are as follows:

802 159

< Mr. B. H. Grier Page 2 July 31, 1979 1.

The inspection and verification program carried out on Unit 1 of pipe supports and associated concrete expansion anchors to meet IE Bulletin 79-02 was extremely comprehensive and included many of the elements required by the Bulletin 79-lh program.

In addition, the results of that inspection sho red very little effect on as-analyzed conditions. Our letter to you of July 6 describes that program, its results, and our schedule for completion.

2.

Experience with the inspection programs for both units vill be continuously evaluated as they progress to verify that continued confidence in the integrity of Unit 1 systems is justified.

Very truly.yours,

/

f~

ws t_.

cc:

J. A. Biddison, Esquire G. F. Trowbridge, Esquire Mr. E. L. Conner, Jr. - NRC Mr. J. W. Brothers - Bechtel Office of Inspection & Enforcement U. S. Nuclear Regulatory Co= mission Division of Reactor Insrection Washington, D. C.

20555 802 160

e AEL Letter of T/31/79 IE Bulletin 79-lh List of Attachments 1.

Systems to be insuccted (1 page).

2.

Unit 1 Isometric List (5 pages).

3.

Unit 2 Isometric List (5 pages).

h.

Unit 1 Ranger Sketch List (12 pages).

5 Unit 2 Hanger Sketch List (lh pages).

6.

valve List, Units 1 and 2 (6 pages).

7 Unit 1 Class I Piping 2" and under (2 pages).

8.

Unit 2 Class I Piping 2" and under (1 page).

9 Engineering Data Recuired for Stress Calculations (1 page).

10.

Inspection Elements (1 page).

802 161 IE Bulletin 79-lh Systems to be Inspected Unit 1 P&ID Unit P&ID Title No.

Rev.

Date No.

Rev.

Dnte Main Steam & Reheat M-35 14 7-07-75 M-36 11 5-20-76 N

1 W

Condensate & Feedvater M-39 Sh 1 114 12-09-76 M 40 8

5-29-76 Service Water, Auxiliary & Containment M l:6 Sh 2 9

8-lh-Th M !:7 Sh 2 10 2-23-76 g

CD Circulating Salt Water M h9 13 7-19-76 M 150 7

9-21-76 m

4 8

Component Cooling M-51 10 7-08-75 M 152 6

9-21-76 4

4 Charcoal Filter Spray M-52 7

5-13-76 M1453 3

5-23-75 Spent Fuel Pool Cooling M-58 10 5-11-76 M-58 Common Well Water, Condensate Storage, etc.

M-59 9 12-07-7h M-59 Common Diesel Generator Systems M-69 9

T-07-75 M-69 9

7-07-75 Reactor Coolant M-72 6

5-13-76 M-460 7

9-21-76 4

CVCS M-73 1h 3-13-76 M h61 10 10-1h-76 SI and Containment Spray M-Th 13 5-13-76 M h62 7

9-24-76 e

O

UtIT el ISOMITRIC 1137 DPAM M.

.U,UE FIVISI W E

SK-M-600 Feedvater - Unit #1 Inside Contairr.ent 1

5-02 74 5K + 606 Spray system header No.1 Inside Containment 1

5-31-74

$K-M-607 Sprey System Beader No. 2 Inside Containment 1

5-31-74 SK-M-608 sh 1 Shutdown Mt. Exch. Piping 1

4-16-74 SK + 608 Sh 2 Shutdown Et. Exch. Piping 1

7-18-74 SK-M-608 sh 3 shutdown ut. Exch. Piping 0

1-09-74 EK-M-604 sh 4 shutdown st. Exch. Piping 1

5-21-74 SK-M-408 Sh 5 Shutdown at. Exch. Piping 1

4 16-74 SK-M-608 Sh 6 Shutdown Mt. Exch. Piping 1*

7 19 74 SK-M-608 Sh 7 Shutdown Mt. Exch. Piping 0

1-09-74 SK + 608 Sh 8 Shutdown Et. Exch. Piping 1

4 02 74

$K M-608 Sh 9 Shutdown Mt. Exch. Piping 1

6-24 74 EK-M-608 sh 10 Shutdown Et. Exch. Piping 1

4-04-74 SK + 608 sh 11 Shutdown Mt. Exch. Piping 1

4-16-74 SK + 608 Sh 12 Shutdown Mt. Exch. Piping 1

4 29-78

$K+608 Sb 13 Shutdown Mt. Exch. Piping 1

2-06 74 SK-M-608 Sh 14 Shutdown Mt. Exch. Piping 0

12-07-73 SK-M-608 Sh 15 Shutdown ut. Exch. Piping 0

12-07-73 sK-M-608 sh 16 thutdown Mt. Exch. Piping 0

11-29-73 SK-M-608 sh 17 Shutdown St. Exch. Piping 1

7-18-74 SK + 608 sh 18 shutdown Mt. Exch. Piping 0

11 29-73 SK-M-609 sh 1 Fressuriser Relief Valve F1 ping Inside Containment 3

10-04-76 SK-M-609 Sh 2 Pres;uriser Relief Valve Fiping Inside Contaiment 3

10-04 76 SK-M-610 Pressuriser Spray System 1

5-21-74 SK-M-411 sh 1 Safety injection Fiping System. Tk 114. Lag 11A 1

3-21-74 sK-M-611 sh 2 safety injection Fiping system. Tk 113. Lag 113 1

3-21-74 5K-M-411 Sh 3 safety injection Piping System. Tk 12A. Leg 12A 2

SK-M-611 Sh 4 Safary Injection Piping System. Tk 123. Leg 12A 1

3-21-74 5K-M-612 Shutdown Cooling Fiping laeida Containment Unit No.1 0

4-29 74 SK-M-614 sh 1 Charging Line - Regenerative Et. Exch. To Coolant IsoF 0

(See F5K-MF) 5K-M-615 Aux Feedwater Inside Contaiment 1

5-21-74 SK-M-617 sh 1 Letdown Beat Exchanger Piping To Furification Domin.

1 6 19-74 SK-M-617 Sh 2 Letdown Beat Exchanger Piping To Furification Domin.

3 6-27-75 SK-M-617 sh 3 Letdown Beat Exchanger Piping To Furification Domin.

1 7-15-74 SK-M-618 Letdown Heat rehanger Piping Cooling water 0

11 29-73 5K + 619 Main & Aux Stasa To Sta Can Aux Feed Pump hrtinee 3

2-12-75 3K-M-610 Sh 1 Comp. Cooling Pump toom Piping Salt veter Systen 2

1-15-75 SK-M-620 Sh 2 Comp. Cooling Pump Room Piping salt veter System 2

1-13-75 BK-M-621 sh 1 Aux. Feedwater 1

7-25-74 SK-M-621 sh 2 Cond. From Storess Tk 2

6-07-74 IK + 612 Comp. Cooling Pump toom Piping safety injection System 0

1-07-74 SK-M-624 Comp. Cooling Pump Room Piping Shutdown Cooling Systes 1

4-04-74 n.

o u.

e e

.CFAV'% No.

M FIVI$1CM M

SK-M-626 Serv. V. Ileat. Exch. Salt Setor Cooling System 5

2 24 75 SK-M-627 Salt Water Pump Discharge Unit do.1 3

7-23-74 SK-M-629 sh 1 Comp. Cooling Pump Rm Piping Component Cooling system 0

1 17 74 SK-M-629 sh 2 Comp. Cooling Pump Rm Piping Component Cooling System 1

3-21-74

$K-M-629 sh 3 Comp. Coolir.g Pump Rm Piping Component Cooling System 1

2 24-75

~

5K-M-629 sh 4 Comp. Cooling Pump Rm Piping Component Cooling Systne 1

6-24-74 SK M-629 sh 5 Comp. Cooling Pump Ra Fiping Component Cooling Systne 1

2-24-75 SK-M-629 sh 6 Comp. Cooling Pump Rm Piping Component Cooling System 2

3 21-74 SK-M-629 Sh 7 Comp. Cooling Pump Rm Piping Component Cooling System 1

11-04-74 5K-M 632 Letdown Line From Regenerative seat Exch.

0 2 21-74 sK-M-634 sh 1 spt Fuel Pool cooling Pp Boom Fuel Pool Cooling system 2

8-27 74 5K-M-634 sh 3 Spt Fuel Pool Cooling Pp Room Fuel Pool Cooling System 0

12-29-73 sK-M-634 Sh 4 Spt Fuel Fool *ooling Pp Room Fuel Pool cooling system 2

5-09-74 SK + 634 Sh 6 Spt Puel Fool Cooling Pp Room Fuel Fool Cooling System 1

5-08-74

$K-M-634 sh 8 Spt Fuel Pool Cooling Fp Room Fuel Foot Cooling system 0

1-03-74 SK-M-635 Sh 1 Spt Fuel Fool Cooling Py Room Service Water System 2

6-05-75

$K + 635 sh 2 spt Fuel Pool Cooling Py Room Service Water system 2

7-31-74 SK-M-637 sh 1 Spc Fuel Pool Cooling Pp Room Fuel Pool Cooling System 0

1-17-74 SK-M-637 sh 2 spt Fuel Pool Cooling Pp Room Fuel Fool Cooling System 0

1-16-74

$K-M-63 Spt Fuel Fool cooling Py Room Fuel Fool Cooling System 2

7-18-70 SR-M-MO Component Cooling 1

3-21-74 SK+ M1 Service Water 2

7-31-74 SR-M.M2 service Water 1

6-26-74 st+M3 servica Vater 1

5-20-74 st+%4 service Water 1

6-12-74 8K-M-M5 3.F. safety 2njection 0

1-17-74 SK-M-M6 Component Cooling 1

3 21-74 EK+M7 Service Water System 1

2-11 75 SK-M-48 service Water system 2

2-04-75 SK-M-M 9 Service Water system 2

6-28-75

$K-M-650 Serviss Water System 1

4-24-74 SI-M-631 service Water Systen 1

4 24-74

$K-M-652 service Water system 1

4-24-74 5K-M-653 Service Water system 1

2-12 74 SK-M-655 service Water w t 0

11 26-73 EK M-656 Service veter out 0

12-05-73 SK N-657 Service Water out 1

6-24 74 SK-M-659 Aux Foodwater 0

11-26-73 SK-M-660 sh 2 From condensate Storage Th. No.12 to Aux Feed Pumps 1

7-09-74 EK + 661 From condenaste Storage Tank 2

7-09-74 st-M-662 L.P. safety injection 1

5-09-74

$K-M-663 L.F. Safety Injection 2

7-18-74 P00R BRIG'M' '

802 y{

s EMVIN %

UTel PIrT513 E

SK-M-664 Containment sprey 2

7-14-74 st-M-665 1.actat is hun Coolins 0

4 29-74 sK-M-666 Compt. Cooling Water in 1

3-21-74

$K-M-667 Compt. Ceating Water out 1

6-14 74 SK-M-668 sesvice Water 0

11 27 73 SK-M-669 Service Water 1

4-25-74 SK-M-670 service Water 0

11 27 73 sK-M-671 Safety injection System 2

8 02-74 KK-M-672 Safety injection System 2

8 02-74

$K-M-673 Safety injection Pump Discharge 2

8 02-74 5K-M-674 Service Water 1

6-24 74 5K-M-675 service Water 1

4-24-74 5K-M-676 Service Water 1

4-24-74 SK-M-677 service Water 1

3-21-74 SK-M-678 To Refueling water Tank 1

5-13-74 8K-M-679 From Refueling Water Tank 1

4 29 74 5K-M-682 Containment 5 prey Discharge 1

5-21-74 SK M-684 From Refueling Water Tank 1

5-14-74 EK-M-485 From Refuelint Water Tank 1

6-19-74 EK-M-686 Shutdown Cooling 1

4 29 74 SK-M-689 1,.F. Safety injection 1

7 10 74 SK-M-690 E.F. Safety injection 1

6-19-74 SK-M-691 spent Fuel Fool Cooling 1

4-29-74 SK-M-692 Spent Fuel Cooling 1

6-27 74 SK-M-693 Contaimment sprey 1

3-20-74 st-M-694 Centatusent Spray 2

5-21 74 SK-M-697 Refueling Water System 1

6-19-74 SK-M-698 Cond. From storage Tank 1

5-20 74 SK-M-699 Aux. Feedveter 0

11-27-73 EK-M-700 sh 1 Component Cooling kater Cutlet, inside containment 2

1 23-75

$K-M-700 Sh 2 Component cooling water Outlet, inside Contairenant 2

5-20-74 SK-M-701 Sh 1 Component Cooling Water Inlet, inside Contate--at 0

11 26-73 Ft-M-701 Sh 2 Component Cooling Water Inist, inside containment 1

5-21-74 SK-N-712 Service Water Inlet Containment cooler #11 2

5 07-74 sK-M-713 service Water outlet containment cooler #11 1

5-23-74 EK-M-726 From Refueltag Water Tank 1

4-29 74 SK-M-728 To Refueling Water Tank 1

5-14-74 SK-M-729 Ftne Refueling Water Tank 1

5-14-74 st-M-734 service Water 1

5-14-74 5K-M-735 service Water 0

11-28 73 31-M-736 Service Water 1

6-27-74 SK-M-737 Service Water 1

6-14-74 I

l

t PWM F4 M

FIVIIIC7 M

$K M-748 Comp. Cooling Water 0

1-17 74 SK-M-749 Comp. Cooling Water 1

5-21-74

$K-M-758 Service Water 2

8-04 76 SK + 751 service Water 2

8-04 76

$K-M-756 servise Water 1

5-04-76 SI-M-739 service Water 1

5-14-74 SK + 760 Service Water 2

7-10-74 5K.H-763 Ser-ice Water 1

5 21 74 SK + 764 Service Water 1,

5-20-74 SK-M 765 service Water 1

5-14-74 SK M-766 Service Water 1

6-11-74 SK M-769 sh 1 service Water riping Inlet Ctat Cooler #12 0

11-28-73 IK M-769 Sh 2 Service Water Firing Outlet Ctat Caolar #12 1

5-07 74 SK+769 sh 3 service Water Piping Inlet Ctat Cooler *13 0

11 29-73 CK-M-769 sh 4 Service Water Piping CP2tlet Ctat Cooler #13 1

5 29-74 SK-M-769 sh 5 Servise Water Piping Inlet Ctat Cooler d14 0

11-28-73

$K-M-769 Sh 6 Service Water Piping Outlet Ctat Cooler #14 2

5-28-74 SK-M-770 Sh 1 Charcoal Filter spray Piping Unit No.1 1

5 07 74 SK-M-770 Sh 2 Charcoat Filter Sprey Piping *-n po. I 1

5 02-74 SK-M-771 Sh 1 From Latdown Pressure Conts.el Valve to Ion t u hanger 2

6-27-74 SK-M-771 sh 3 From utdown Pressure Control valve to Ion Exchanger 1

5-21-74 SK-M-772 sh 1 Boris Acid Pump suct. and Pump Discharge to Charging Pump 0

11-23-73 SK-M-772 sh 2 Boric Acid Pump suct. and Pump D:scharge to Charging Pump 2

11-25-74 SK-M-772 sh 3 Boris Acid Pump suct. and FM Discharge to Charging Pump 2

10-07-74 SK-M-772 sh 4 3 aria Acid Fump suct. and Pump Discharge to Charging Pump 0

11 29-73 SI-M-775 Refueling Pool Recycle Piping Inlet inside Contamt 1

4-12 74 5K-M-778 57T Puel Fool Cooling ffetec 0

12-11 73 sI-M-780 SFT Twel Fool Cooling System 0

12-11-73 SK-M-781 SFT Fuel Fool Cooling Syste 0

11-26-73 st-n-782 SFT Fuel Fool Cooling System 0

12-11-73 5K-M-783 Component Cooling water 1

9-10-74 EK-M-784 Component Cooling Water 1

5-25-74 SI-M-785 Component Cooling Wats >

2 6-10-74 SI M-786 Component Cooling Vater 2

9-10-74 SI-M-787 Componat Cooling Water 0

12-2?-73 2t + 788 Component Cooling water 1

5-11-74 5K c=791 Component Cooling Water 1

2-24-74 SK-M-792 Component cooling water 0

12-5-73 SI-M-813 Eafety lejection Relief to truench Tank 0

1$.- h SK-M-821 Component Cooling Water 1

3-15 74 EK-M-822 Component Cooling Water 2

9-11-74

$1-M-823 Salt Water Supply To KCCS Fump toon Cooler #11 2

6-24-74 f

D W ITC FO.

M PIvifts g

SR-M-824 Salt Water Supply From ECCS Fump Room Cooler #11 1

4-29-74 5K-M-813 salt Water supply To KCCS Fump toon Cooler #12 0

9 11 73 31-M-426 salt Water supply From ECC5 Fump Room Coolet #12 1

44N74 5K.M-827 Salt Water Frt - ECCS Fump Room Cooler #12 1

4 29 74

$1-M-829 Containment Refueling Pool Drain 0

1-16-74 SK-M-831 Component Coeling typees Component Cooling System 1

3 11 74 St-M.832 Component Cooling typass Component Coeling system 1

4 24-74 EK-N-833 service water Read Tanka 1

7 11 74 SK-M-839 Sh 1 4" Byd. supply F1 ping Main Steam Isolation valve 1-CV-4043 1

6 04-74 SK-M-839 sh 2 4" Byd. Surply Piping Main Steen Isolation valve 1-CV-4044 0

12 28 73 5K-M-839 Sh 3 4" Byd. Return Piping Main Staam Ise!stion valve 1-cv4043 1

5-24 74 SK-M-834 sh 4 4" tyd. Return Piping Main Staam Isolation valve 1-cv-4048 0

12 28 73 EK-M-?086 Domineralised Water To Miscellaneous Systems 1

9-08-76 M-177 Main Staan Piping System Isometric 8-06 75 802 167

~

a c Attach:: lent 3 tm #7 is~mn un DUM M.

M Pf?7517N M

SI+604/19 shutdove gaat Exchaeger Piping 1

10-31 74 ER-M-608/20 Shutdown meat tachanger Piping 2

%,28-75 SE-M-608/21 Shutdown deat Exchanger Piping 3

5-14-75 5K + 608/22 Shutdown usat Exchanger Piping 1

7 29-74 53-M-608/23 Shutdown Beat Exchaeger Piping 1

2-04-75 St M-408/24 shutdown Heat Esshanger Piping 0

10-22-73 SI-M-608/25 Shutdown Heat Exch*nger Piping 2

5-13-75 II-M-608/27 Shutdown Rest Exchanger Piping 2

5-21 75 SE-M-608/28 Shutdown samt Exchanger Piping 3

6-22-75 3R-M-608/29 shutdown Beat E msnser Piping 2*

5-14-75 SE-M-628 Salt Water Pr pe Unit #2 5

1 13-75 5K-M-629/7 Comp. CooLira hap Isom F1 ping Comp. Cooling System 1

11-Os-7a 5K-M-634/2 Spent Fuel Fool Cooling Pump Race. Fuel Foot Coe11cs System 2

3-28-75 SI-M-634/5 Spent Fuel Peol Cooling Pump Room, hel Fool Cooling System 1

4-12 74 5K+634 /6 spent het Foot Cooling Pump Soca. Fuel Foot Cooling Systen 1

3-08-74 SK-M-634/7 Spc Fuel Fool Cooling Pump Room. Fuel Fool Cooling System 0

1 03-74 St-M-635/1 spent Fuel Fool (soling Pump Reos Service Water system 2

6 05 *3 SK-M-635/2 Spent Fual Foc-Cooling Pump Room Isrvice Water System 1

7 34 74 SK-M-660/1 From Cond. Storege Tk #21 to Aua. Feed Pumpe 4

7 29-74 3R-M-660/2 From cand. Storage Tk #12 to Aux. Feed Pumpe 1

7-09-74 5K-M-681 From cond. Tad to Auz. Feed Pumpe 1

3-11-75 5K + 7C2 Cente brtet sprey 1

3 04 75 SK-M-703 Spent het Pool Cooling 6

5-13-75 51-M-704 Componee': CoJ11ng i

11-05-74 SI-M-705 Free Cond. Tk to Aux. Feed Pump

  • 4 1-17-75 SI-M-706 Aux. Feodwater 3

8-23-75 5K-> 707 Service Water systen 2

10-02-74 IK-M-708 Service Water System 3

10-02-74 SK-M-709 spent Fuel Fool cooling 2

3-28-75 SE-M-710 Coitainment Spray S

12-09-74 51-M-711 Component Costing Water 4

8-06-76

$K-M-714 Service Water 1

11-05 74 SK-M-716 Eafety injection system 1

12-09-74 EK-M-717 Safety Inj-etion system 1

1-W 75 SK-M-718 Safety injection Pump Discharge 1

1-09-75 EK M-719 Service Water 2

10-21-74 51 N-720 service Meter 3

10-02-74 8E-M-721 Service Water 2

10-17-74 SI-M-722 To Refueling hter Tank 4

4-13-75 SX-M-723 Refooling Pool Fill 3

3-06-7*.

SI + 724 Refueling Pool Drain 0

1 > 22-73 51-M-723 From Fafueling Water Tank 0

11-28-73 51-M-730 From Refueling Water Tank 5

4 03-75 UkM{[f k

2 Ju

.=

402 1<0

I _ __ tuvDC ?M.

E p!"I71CM g

4 SK-N-732 To Refueling Water Tank 6

5-02-75 SK + 733 From Refueling Water Tank 2

2-04 75 SK-M-738 Service water 2

11-05-74 sK-M-739 Service Water 3

8-11-75

$K-M-741 Service Water 2

10-20-74 SK-M-738 Spent Fuel Foot Coeling 6

1 06-76 SK-M-759 Service Water 1

5-14-74 St-M-761 Service Water 1

6 27-74 SK-M-762 service Water 1

5-14-74 st-M-765 Service Water 1*

5 14-74 5K-M-766 Service Water 1

6-11 74 SK-M-772 /!

Volume control Tank #21 Dischar2e to Charging Pumps 2

4-11-75 SK-M- /7; Spent Fuel Fool Cooling system 1

2-12 74 SK-M-779 Spent Fuel Fool Cooling System 0

11-28-73 SK-M-785 Component cooling Water 2

6-10-74 nK-M-725 Component Cooling Water 2

9-10-74 SK-M-789 Component cooling Water 1

3-21-74 SK-M-790 component Cooling Water 1

5-14 74 SK-M-793 Component Cooling Wster 2

10-31-74 SK-M-794 Component Coottog Water 3

2 24-75 SK-M-817/35 Drains To Misc Waste Receiver & Monitor Tanks fit 6

8-06-76 SI-M-845/1 Safety injection Piping system (Tank d21A Lag #21A) Unit #2 9

2-05 76 SK-M-843 /2 safety injection Piping system (Tank #113 Les #213) Unit #2 8

2 05-76 SK-M-845/3 Safety injection Piping system (Tank #224 Les #22A) L' nit #2 9

2-C5-79 SK-M-845/4 Safety injection Piping system (Tank d223 Les $223) Unit #2 9

2 05-76 SI + 856 Freasuriser Sprey Syste Unit #2 11 1-26 76 5K-M-876/1 Fressuriser Relief Talve Piping Inside Ctat 2 10 1-26-76 st-M-876/2 Freeruriser Reliaf valve riping Inside Ctat 2 10 1 26 76 SK-M-878 Shutdown Cooling Piping. Inside Ctat. Unit #2 6

11-11-75 SK-M-379 Reactor shutdove Cooling 4

12-11-75 II-M-880/1 service Water Piping Inlet Ctat. Cooler #22 1

7-31 75 SK-M-880/2 service Vatar Piping cutlet Ctat. Cr y e3 2

6-14-75

~

SK-M-880/3 Service Water Piping Inlet Ctme wi.: 823 0

1-16 74 SK-M-880/4 Service Water Piping out!

on t 623 0

10-17-73 SK-M-880/5 Service Water Piping In;. tut. 14.n' *, 924 1

6-14-75 SI-M-860/6 Service Water Piping Ntlet Cast. Looler eie 1

8-14-75

$K-M-881 service Water inlec Unit #2 2

8-14-75 st-M-882 service Water 6

12-09 75 EI-M-883/1 Service Water 2-24-75 SK-M-883/2 Service Water System 2 24-75 EK-M-884 service Water out 0

12-28-73 EX-M-885 service Water w t i

12 25-73 SI-M-886 service Water Outlet Ctat. Air Cooler d21 1

2 04-76 Dnnn 09%802 169 2

luuf[WidJhikr

,__ pwim MO.

tmz

__ s m stem pm i

SK-M-837 Service Water Out 1

3-15-74 SI-M-888 Service Water Out 3

3-26-76 SK-M-889 Servica Water Head Tank 4

10-24-74 SK-M-890 Service Water Unit #2 1

9-10-74 SK-M-891 Service Water System 2

10-04-74 SE-M-892/2 service Water System 3

2-24 75 SK-M-892/1 Service Water System 5

2-14-75 SK-M-893 Service Water System 2

2-03-76 SK-M-894 Service Water System 0

10-17-73 SK-M-895 Service Water Systen 0*

10-17-73 SK-N-896 Shutdown Raat Exchanger Piping Unit #2 2

5-23-75 SK-M-898 Service Wate:; Inlet Ctat Cooler #21 1

8-19-74 SK-M-899 Service Water System 2

3-10-76 SK-M-900 Service Water System 2

6-10-76 SK-M-905 Shutdown Beat Exchanser Piping Component Cooling System 1

10-31-74 SK-M-906 Shutdown Heat Exchanger Piping component Cooling System 2

6-13-74 SK-M-907 Shutdown Heat Exchanger Piping Component Cooling System 1

4-02-74 SK-M-908 Shutdown Best Exchanger Piping Component Cooling System 3

10-31-74 SK-M-909 Shutdown Beat Exchanger Piping component Cooling System 0

3-14-74 SK-M-910 Shutdown Heat Exchanger Piping Component Cooling System 3

8 20-74 SK-H-911/1 Component Coiling Pump Room Piping, Component Cooling Systen 1

11-04-74 SK-M-911/2 Cot

nt Couting Pump Soom Piping, Component cooling System 0

10-26-73 SK-M-911/3 Component Cocling Pump Roca Fiping, Componeet Cooling System 2

2-24-75 SK-M-911/4 Component Cooling Pump Room Piping Component Cooling System 0

10-26-73 SK-M-911/5 Component Cooling Pump Room Fiping, Component Cooling Svetna 1

2 24-75 SI-M-912 Component Cooling Water, Unit #2 1

11 01-74 SI-H-913 Component Cooling Water Unit #2 1

11-01-74 SK-M-914 sealing water leturn Fram EFS1. LFS1 Fumps. Component Cooling System 5

3-14-75 SK 4-915 Letdown Beat Exi: banger Piping, Component Cooling Water 3

10-31-74 SK-M-916 Component Cooling outlet, Unit #2 2

7-11-74 S..-N-917 Component Cooling Water, Unit #2, Inlet 5

11-05-74 SK-M-913 Composent Coolirag sypass Component Cooling System 1

11 04-74 SK-M-919 Component Cooling typass Component Cooling System 0

10-26-73 SK-M-922 Service Water 2

8-11-75 SK-M-923 Shutdown Cooling 4

11-12-75 SK-M-928 From Refueling Water Tank 1

12-20-74 SF-M-929 Air Intake To Emers. Diasel can (21 0

1-18-74 SI-M-931 Letdown Beat Exchanger To Furification Demineraliser 3

1-06 76 31-M-932 From Letdown Frass. Control valve to Ion Exchangers 4

1 06-76 SK-M-933 From Letdown Press. Control valve to Ion hehagers 0

9-11-73 SK-M-934/1 Refueling Pool Recycle Piping Inlet, inside Containment 0

1-18-74 SK-M-934/2 Refueling Pool Recycle Piping inlet, inside Containment O

1-18-74 SK-M-935/1 Service Water Best Exchanger Pipios. Salt Water Cooling Sys. Unit #2 5

8-31-76 802 170 P00RBR W

DFAm M.

M

_ _ REV171(N g

sK-M-935/2 Service Water Best Exchanger Piping. Salt Water Coeling sys. Unit #2 2

7-15-76 SF-M-937 Aux. Feedwater Inside contairment 1

9-04 74

$K-M-938/1 Aux. Feedwater Inside Contairment 2

9-15-74 SK + 938/2 Aux. Feedvster Inside Contairment 1

,4-01-74 SK-M-939 R.F. Safety injection 2

12-09-74 5K + 941/1 Containment spray sys. Baader #2, Unit #2 0

1-17-74 51-M-941/2 contairument Spray sys. Reader #2, Unit f 2 1

4-24-75 SK-M-942 Spray System Header No.1 Inside contairment 3

6-09-75

$K-M-943/1 Charcoal Filter Spray Piping Unit f2 3

8-14-75 5K-M-943/2 Charcoal Filter Spray Piping Unit #2 3

8-14-75 SK-M-943/3 Charcoat Filter Spray Piping Unit #2 1

3 31-75 SK-M-94 3 /4 Charcoat Filter sprey Piping Unit #2 2

12-11-75

$K-M-944 Containment Spray Discharge 2

12-12-74 SK-M-%3/1 Component Cooling Pump Room Cooling 3

1-29-75 SK-N-945 /2 Component Cooling Pump Room Piping 3

1-29-75 SK-M-946 Salt Water Supply to ECCS Pump Room Cooler #21 5

3 27-75 SK + 947 salt Water Return From ECCS Famp Room Cooler #21 4

4-19-75 SK-M-948 salt Water Supply to ECCS Fump Room Cooler #22. Unit #2 4

4-29-75 SK M-949 Salt Water Return From ECCS Fump Room Cooler #22 4

4-29-73 SK + 950 satt Water Return From ECCS Fump Room Cooler #22 1

12-05 74 RK-M-952/1 Boric Acid Pump suction & Discharge To Charging System 4

3-28-75 SK + 952/2 Borie Acid Pump Suction & Fump Discharge To Charging System 2

5-06-75

$K-M-952/3 Beric Acid Pump suction & Discharge To Charging System 2

8-12-74 SK-M-952/4 Roric Acid Pump Suction & Discharge To Qarging Systen 1

9-05-74 SK-M-953 Component Cooling Pump Room Piping Safety injection System 2

5-02-75

$1 + 954 Shutdown Beat Exch. Piping 1

9-23-74 SK-M-955 shutdown seat Exch. Piping 0

1-17-74 SK-M-956 Component Cooling Pump Room Piping. Shutdown Cooling System 6

5-12-75 5K-M-957 L.F. safety injection systen 2

7-03-75 EK*M-958 2,.F. safety Injection 2

5-13-75 SK-M-959 E.F. Safety Injection 3

4-08-75 SK-M-900 safety injection Rectre. To Refueling Water Tank, Unit #2 7

1-09-75

$K-M-961 Containment Spray 1

12 09-74 sK-M-962/1 From imtdown Pressure Control valve To Ion Exchangers 1

5-28-75 3K-M-962/4 Line From Purif. Filter To Latdown Strainer Entrance 4

6-20-75 SK-M-963 From Refueltas Water Tank 2

4-03-75 SK-M-964 Refueling Water System 2

4-03-75 SK-M-966 L.F. Safety injection system 5

7-03-75

$K-M-967 Containment Refuel Fool Drain, Unit #2 0

12 20-73 SK-M-981 Refueling Water Tank yo. 21 F1 ping 2

11-27-74 sK-M-986/1 4" Byd. F1 ping To Main sta lao. valve 3

8-06-75 st-N-986/2 4" Byd. Piping From Main Stu Iso. Talve 1

7-23-75 SK-M-986/3 4" Byd. Piping To Main Sta Iso. Velve 1

7-23-75

i_ _

DFAV"C MO.

M RETTSts E

6

$K-M-996 1.V.S. Tk (21 Beater Recirc. Internal standpipe 0

3 18-74 SK-M-997 Pefueling water Unit #2 3

12 15-75 5K-M-998 Feedvater inside Contairsment 1

4-21-75 SK-M-1000/1 Feedwater Inside Aux. 31ds.

I 7 13-75 SK-M-1001 Condensata From Storese Tk 2

6 19-75 sK-M-1002 Aux. Feedveter 1

7 15-74 SK-M-1019 Rafueling water 0

6-17-74

$E-M-1020 Component Cooling Bead Tk #21 overflaw 0

7-18 74

$K-M-1023 Safety injection Ralief To Quench Tk, Unit #2 2

8-11 75 SK-M-1048 Inlet 6 outlet service Water Heat F.ach. #12 2*

8-11-76 EK-M-1087 Domineralised Water To Misc. Systems 1

9-08-76 St-M-1090 Diesel Gen. Starting Air 0

9-11-76 SK-M-1091 Diesel Cen. Starting Air 0

7-21-76 SK-M-1600 Aux. Feedwater Turbine Exhaust Unit #2 2

7-11-75 SK M-1601 Aux. Feedwater Tarbine Exhaust Unit #2 1

5-13-75 M-179 Main Steam System Unit #2 13 11-10-76 Ult /9Glug 5

802 172

Attne WEnt h Page 1 of 12 MA E !7 Sr!Tcv W M P !

FCR tw 180.1 SK-M-600 SK-5811 SK-M 607 SK-546 5810

-545 5809

-544

-5805 543 5807 542

-5806 541

=5805

-581

-5804

-855 5803

-339 5802 540

-5801

-538 5800

-5700 31-M.608/1 sE-1710

-5701

-1712 *

-3702 1708

-5703

-17%

-1769 SK-M-606 sK-100 1700 104

-33127 130

-1716

-132

-1719 134

-1723 150

-1725 152

-1727

-135

-1702 160 8108 223

-1796

-220

-1731

=206

-1734 204

-1728 200

-154 st-M-608/2 SK-8107

-182

-141

-180 32098 579

-143 571 144 572

-145

-517

-146

-316

-147 515

-148 513

-149 512

-150 578

-151 505 24943

-506

-15 3

-507

- 135

-577 160 27206

-26919 500 SK-M-608/3 SK-111 SK.M-607 st-800 104 802

-102

-803 101 807

-D0

-809 850 SR-M-608/4 st-183

-810

-26942 612

-181

-813

-179 817 180 820

-821 st-M-608/5 SK-167

-825 166 826

-165 84 7 164

-846

-163

-845

-162

-844

-170

-840

-169

-839

-172 838

-173

-837

-174

-853

-176

-836

-177 832

-178 831

-162

-830 829 EK-M-608/6 EK-12099

-860 140

-848 139 580 138

-548

-136 547

-134 ER@mgLr 802 173

Pese 2 of 12 s

3K-M 608/6 sE-133

$K-M-608/13 sK-26925

-132

-1159

-131

-1675

-130

-1674

-125

-1657

- 15 8

-1635

-26928

-1323

-26929

-1663

- 15 2

-1661

-129

-1623

-128

-1621

-127

-1622

- 126

-1630

-26921

-1676

-1300

-1627

-1303

-1633

-1304

-1306 st-N-608/14 5K-1763

-1308

-1766

-1775 sK-M-608 /7 sK-26918

-1777

-118

-1743

-115

-1746

-116

-1748

-114

-1750

-105

-1754

-107

-112 SK-PH6' '15 sK-1648

-109

-1650

-1652 SK-M-608/8 SK-26934

-1643

-124

-1673

-123

-1646

-121

-1640

-120

-1638

-119

-1655

-26919 st-N-608/9 st-26932

-33391 SK-M-608/16 SK-26926

-26923

-14C5

-1007

-1410

-1005

-1413

-1003

-1415

-1000

-1418

-1402

$K-M-608/10 SK-1200

-1407

-1202

-1400

-26922

-1208 st-M-608/17 st-1422

-1010

-1425

-1014

-1432

-26931

-1435

-1446 sK-M-608/11 SK-1338

-1444

-1138

-26930

-i143

-1428

-1100

-1430 26927

-1442

-1617

-1613

$1-M-608/18 SK-26921

-1611

-1130

-1609

-1141

-1606

-1132

-1600

-1128

-1669

-1134

-1667

-1665 SK-M-609/1 SK 19032

-1671

-19031

-26914

-19030

-19029 SK-M-608/12 SK-1144

-19027

-1137

-19022

-1120

-19023

-1139

-19024

-1111

-19021

-1109

-25008

-1108

-19017

-1103

-19016

-1142

-19019

-1115

-19013

-1113

-33649

-1117

-33645

-19009 bklfQ 802 174

Page 3 of 12 SR-M-609/1 EE-19010 3r-N-611/2 EX-18321

-19011

-18320

-19005

-18319

-1*0 04

-18318

-19003

-18317

-19002

-18316 19001

-18315

-19000

-18314

-19006

-18313

-19007

-18312

-19004

-18311

-18310 SK-M-609/2 3: 19020

-18309

-19019

-18308

-19018

-18307

-15007

-18306

-17510

-18304

-17509

-18329

-17508

-18332

-17507

-18300

-33644

-18302

-17501

-17502 Ex-N-(11/3 EK-17708

-17503

-17707

-33643

-17706

-17516

-17705

-17517

-17704

-17500

-17703

-17513

-17711

-17514

-17712

-17515

-17521 52-N-611/4 EK-18713

-17522

-18714

-18715 SK M-610 SK-19116

-18712

-19117

-18709

-19118

-18708

-19106

-18707

-19107

-18700

-19108

-18701

-19109

-18715

-19146

-18703

-19147

-18704

-19129

-18705

-19132

-18706

-19110

-18710

-19111

-18711

-19112

-19113 SK-M-612 EK-16300

-19114

-16301

-19115

-16302

-19131

-16303

-19130

-16304

-19122

-16305

-19121

-16306

-19120

-16307

-19105

-16308

-19104

-16309

-19103

-16310

-19128

-16311

-19102

-16312

-19100

-16313

-19144

-16314

-19101

-16315 3R-M-611/1 EK-17100 st-M-613 sK-20000

-17101

-20001

-17102

-20002

-17103

-20003

-17111

-20004

-17112

-20005

-17104

-20006

-17105

-20007

-17114

-19913

-17110

-19909

-17106

-19908

-17107

-19907

-17108

-19906 j

-17113

-19905

-17109

-19904

-19903

-19911

-19910

-19902

-19900 y

802 175

Page 4 of 12

$K-M-418 SK-14300 SK-M-626 SK-207 5204

-40268

-5202

-202 3200

-209

-224 SK-M.619

-36421

-210

-21910

-4C269 21907

-205

-21908

-208

-21925

-2 06

-21926

-211

-21927

-40*70

-21906 36417 5K-M-627 SK-10630

-21901

-10600

-21932

-10610 21933

-10611

-21903

-10612

-36416

-10622

-21922 10623

-21923

-10613

-11924 10615 21904 10616 2260

-10609

-26901

-10628

-36454

-10603

-10602 SK-H-620/1 SK-604

-10606 605

-10607

-607

-10608

-608

-10624 610

-10625

-609

-10615

-620

-10629 36246 10a04

-6 12 10605 SK-M-620/2 SK-600 SK-M-629/1 SK-19C2

-603

-1901 619 1900

-618

-1903

-602

-1904

-1905 st-M-621/1 st 11513

.1906

-11516 1909

-11517

-1910

-11511

-1911

-11512

-1912

-11514

-1913

-11515

-11509 5K-M-629/2 sK-1919

-11508

-1920

-26952

-1921

-1923 Ex-M.621/2 tr.11506 1916

-11503 1915

-11504

-1922 11502

-1925

-11505 1914

-11501 1917 24951 1928

-1929 SK-M-622 SK-8106

-8111 SK-M-629/3 gK-916 8108

-918

-8112

-909 8113

-913

-81G7

-923

-26942 SK-M-624

$K-1510

-924

-26928

-928

-1516

-920

-1502 929 1514

-907

-1500 940

-1512 914

-26929 J.,

802 176

Page 3 of 12 rK-M-423/4 SK-24928 EK-M-634/8 SK-19205

-1830

-19206

-1827

-19203

-1518

-19204

-1819

-19207

-1823

-19208

-1823

-19202

-1814

-19201

-1804

-19200

-1800

-19209

-1810

-19210

-1808

-19211

-1606

-19212

-26917

-19213

-19214 5K-M-629/5 SK-26834

-17902

-900

-17904

-904

-17903

-150ta

- 3 64 S6 EK-M-635/1 sE-13103

-935

-13105

-932 SK-M-635/2 SK-13206 SK-M-629/6 SK-8000

-13204

-9001

-8002 SK-M-637/2 SK 27203

-8008

-27202

-8009 SK-M-638 SK-33101 SK-N-634/1

$K-24905

-32700

-5307

-33103

-5305

-3300 EK-N-640 SK 24929

-5308

-3329

-5309

-3327

-3312

-3304

-16005

-3303

-5302

-3302 5310

-14200

-24921

-2733

-5311

-2720

-24918

-2719

-14201 SK-A-6 34/3 SK-16906

-14202

-16907

-16908 St-M-641 SK-27000

-16901

-12603

-16902

-12604

-15.F03

-12513

-16904

-3305

-16905

-3304

-16900

-12614

-12601 SK-M-634/4 5K-18430

-12600

-15427

-12613

-18426

-12612

-13009

-3306

-15423

-12602

-18423

-12610

-24920

-12609

-18431

-12608

-18422

-12607

-15421

-18420 IK-M-642 EK-3306

-24922

-3305

-1. 18

-13302

-18428

-13301

-15429

-13300

-3323 FK-M-634/6 sx-26913

-2742

-16411

-2728

-26914

-2727

-18414

-18417 SK-M-643 EK-2727

-18413

-2728

-18414

-2742

-18413

-3324

-13904

-3325

-18403

-13700

-16402

-13701

-15401

' 3304

-18410

-3305

-18408

-3306 l

-16405

-13704

-18404 F

I l[

-13703

-18406 l

)i

[

-13702

-1s407 d

j jj p

802 177

Fase 6 of 12

$K M-644 SK-3306 EK-M-649 SK-20310

-11002 20300 3305

-20306 10007

-22201

-10008

-20307

-14007

-20308

-3325

-20306 3323

-20305 2748

-20303 20302 sK-M-645 sE-27205

-20301 15210 20300 15204 20309

-15211

-15200 SK.M-650 SK.16400 15201

-16401

-3304

-16402 3303

-16403

-3300

-16404

-2735 16405

-2734

-16406

-2733 16407

-2720

-16408 2718 16409

-2717

-16410

-15202 16411 26930

-16412

-16413 SK-M-646 SK-33635

-16414

-33630

-12203

-33637

-22204

-3317

-3312 SK-M-631 SK-22205 24927

-22206

-3305

-16415

-3312

-16416

-2717

-16417

-14300

-16418

-16419

$K-M.647 gr 10317

-16420

-10333

-16421 10340 22202 10341

-10312 sr M-631 SK-21207

-10336

-16423 10305

-16424

-10301

-16423

-10302

-16426

-10313

-10319 5K->>653 SK-13669

-10314 13668

-10304

-13667 10315

-13666

-10333

-13665

-10334

-13664

-10330

-13663

-10331

-32035

-10332

-13662

-10318

-13661

-10308

-33569 10317

-33570 10307

-32037

-10320 13671

-10316

-13673

-10306

-13670

-10310

-13671

-10309

-32034

-10321

-13659 10322

-13660

-10323

-10324 BK-M-655 sr.17300

-24954 17301

-10303

-17302

-10326

-17303

-10327

-24910 SK-M-648 EK-16117 SK-M-636 EK-24909

-16118

-7000

-16119 16100 SK.M-657 SK.7001

-16101

-7003

-16102

-16103

-16104

-16105

-16107

-16112 61 ruu[w a3r]I.)gl[j)

-16111 4 hg

Pese 7 of 12

=

SK-M-639 sK-33042 st-M-674 sK-24956

-6104

-10003

-6105

-10008 6106

-10007

-o100

-6101 SK-M-675 sE 10011

-6102

-10002

-6103

-10000

-6107

-10009

-6108

-10010

-6109

-10004

-6110

-10001

-6111

-10006

-6112

-24955

-6113

-10005

-24944 SK-M-660/2 SK-3'353

-24955

-33392 sK-M-676 31-9603

$1-M-661 s -35391

-9606

-21411

-9614

-214c8

-9613

-21409

-9612

-21407

-9605

-21414

-9611

-21405 9604

-214Je

-21404 SK-M-677 SK-9412

-21413

-9404

-21403

-%05

-21410

-S413

-21415

-9414

-%15 sK-M-662 st-18105

-%06

-18106

-9407

-18104

-%16

-18103

-18102 SK-M-678 SK-13916

-18101

-13913

-12100

-13915

-2490c

-13911

-13912 SK-M-663 sK-18203

-13910

-40519

-13909

-18201

-13908

-18202

-13907

-18200

-18613 st-M-679 31 22008

-22007 SK-M-664 SK-10717

-22006

-10716

-22005

-10713

-3289

-14923 st-M-690 sK-27210 sK-M-665 SK-16317

-8905

-16318

-8904

-18900 SK-M-666 SK-11200

-3318

-24929

-3319

-32071

$1-M-667 SK-24926 st-M-691 sK-!742 sK-M-668 31-3224

-2,*29

-3226

-2728 32 "

r.3 SK-M-692 SK 33032

-16000 sK-M-669

.K-9312

-16001

-9320

-16002

-9318

-16003

-9317

-9316 51-M-693 SK-3303

-9315

-3304

-9314

-14800

-9321

-14801

-14802 sK-M-670 SK-6000

-14803

-6001

-14804

-6002

-3318

-3320 sK-M-673 SK 11302

-24923

-11303A I

-11300 SK-M-6 %

sK-10705

-11301

-10712

-11306

-11304

-11303 P % R g gH I 30 2 179

Page 8 of 12

.K-M-695

$K-8007 2K '-700 sh 1 SK-21508 d

-8006

-21500

-8005

-21501

-8004

-21505

-4008

-21502

-21504 SI-M-697 51-2717

-14102

-2719

-14100 2720

-14101

-26902

-21506

-14105 sE-M-698 SK-21400

-26905

-21401

-21402 SK-M-700 sh 2 sx-24915

-14400 SK-N-699 sE-24952

-14404 6114

-14A01

-6113

-14402

-6116

-14405 6117

-14403

-6118

-14106

-6119

-14104

-6120

-14409

-6121 SK-M-701 sh 1 SK-14700 3K-M-671 sK-11320

-14704

-11321

-14702

-15202

-14705

-14707 sK M-672 SK-11314

  • 14706

-11315

-14708

-11416

-14703

-27210

-14709

-24924 sK-M-682 SK-10704

-10703 SK-M-701 sh 2 st-14715

-1070?

-14714

-10701

-14713

-10700

-14716

-14712 sK-M-684 st-15$00

-14718

-12501

-14710

-15503

-14711

-15504

-15502 sK-M-712 sK-12304

-L5505

-12303

-12302 sK-M-685 sK-26925

-12301

-21307

-12300

-21306

-21305 sx-N-713 sK-12400

-21304

-12402

-21302

-12403

-21301

-12405

-21300

-12404

-12406 SK-M-686 sK 01813

-3303 sI-M-726 sK-12000

-3304

-12001

-21100

-22002

-24912

-22001

-16316

-22004

-16319 EK-4 728 st-13917

-M-689 st-18613

-13905

-18601

-1 906

-18600

-18203 sI-M-729 SK-15508

-18603

-15507

-18604

-15506

-18605

-18606 st-M-734 sr-9617

-18614

-9616

-18615

-9615

-18607

-9600

-18608

-9608

-18610

-9601

-27211

Page 9 of 12 SK-M-732 SK-9602 sK-M-766 gK-9812

-9609

-9806

-;610

-9804

-9613

-9808

-9807 SK-M-735 SE-8905

-9813

-8900

-33590

-8901

-9800

-8902

-8903 SR-M-769 sh 1-SK-9500 8904

-9501

-24963 9502

-9503 EK-M-737 SK-8802

-9504

-E800

-9505

-8801

-9506

-9507 SK-M-748 SK-24953

-9508 11201

-9509

-11202

-9510

-11203

-9511

-11204

-9512 9513 SK-M-749 EK-15000 9514

-19300 9515

-19301

-19302 EK-M-769 sh 2

$K-9716

-19303

-9717

-11204

-9718

-9719

$K-M-750 SK 5909

-9720

-5910

-9721

-5918

-9723

-5902 9724

-5907

-9715

-5908

-9726

-5900

-9735

-5906

-9733

-9734 SK-M-751 SK-5917 5916 SK-M-769 sh 3 SK-12100

-5904

-12101

904

-12102

-5916

-12103

-5911

-12104

-5912

-12105

-5903 12106 EK-M-756 SK-21800 EK-M-769 Sh 4 5K-12200

-21801

-12201

-11802

-12202

-21803 122c3

-L2204 5K-M-760 Ex-21803

-12205 9918

-9924 EK.M-769 sh 5 SK-9700 9917

-9701 9916

-9702

-9923

-9703

-99 13

-9704

-9914

-9705

-9913

-9706

-9929 9707

-40517

-9727 9728 st-M-763 SK 9818

-9817 SK M-769 Sh 6 SK-9708

-9816

-9709

-9815

-9710 9711 EK-M-764 SK-9805

-9712

-9811

-9713

-9804

-9714

-9803

-9729

-9800 9730

-9731 SK-M-765 51 9815

-9732 9819

-9826 SI-M-770 SK-16210

-9820 sh1&2

-16200 9821

-16201 9812

-16202

-9823

-16203

-9827

-16204

-33586

-16205 2

Pe8e 10 of 12 SI-M-770 SK-1606 sI-M-77. Sh 1 SK.23210 Sh1&2

-16207

-23264

-16208' 23227

-14209

-23229

-16210

-23228

-16213

-23248

-17020

-23244

-17001

-23230

-17000

-23242

-17002

-25251

-16213

-23230

-19812

-23224

-19813

-23225

-19807

-23249

-19822

-23226

-19800

-23252

-19805

-1980.

SK-M-771 Sh 2 51-23235

-19803

-23233

-19804

-23234

-19815

-23243

-17004

-23245

-17003

-23244

-17008

-33116

-17006

-23241

-17007

-23239

-17005

-23238

-17009

-23237

-17010

-23239

-17011

-17012 81-M-772 sh 1 SK-32086

-17013

-32095

-17830 30501

-17809

-21007

-17810 27212

-17811

-2417

-17812

-2418

-17813

-26909

-17814

-26001

-17815

-2423

-17816

-2424

-17817

-2425

-17818

-2400

-17819

-21001

-17833

-21000

-17831

-33000

-17821

-21002

-17822

-21008

-17823

-21N

-17824

-26908

-17825

-17826 st-M-772 sh 2 SK-2439

-17827

-2438

-16211

-2430

-16210

-2441

-17834

-2430

-17800

-11202

-17801

-2429

-17802

-11201

-17803

-2427

-17828

-17829 SK M-773 sh 3 sK-32995

-17804

-35883

-17806

-30502

-17805

-21204

-17807

-12900

-17808

-11205

-17834 2433

-19820

-19700

-19821

-32096

-19819

-19702

-19817

-19701

-19818

-19700

-19816

-21203

-19800 33001

-19809

-2000

-19810 25700

-19811

-26000

-17820

-2003

-17832

-2004

-19801

-2007

-19802

-2002

-19814

-25704

-2006

-2005 J

g 802 187

Pa8e 11 of 12 8K-M-775 sI-20701 st-M-791 SK-24917

-20702

- 944

-20703

-945

-20700

-947

-26906

-20807 SK-M-792 SK-28206

-20808

-1832

-20805

-1833

-20806

-20809

-20803

-20906

-1080'.

-20903

-20400

-20904

-2 D801

-20902

-20802 SK-M-821 SK 20901 SK-M-778 sK-20500

-20900

-15009

-35241 FK-M-780 SK-24902 SK-M-822 SK-27908

-17907

-27907

-17906

-27906

-17904

-27108

-27307 SK-M-761 Ex-17901

-27304

-35415 SK-M-782 EK 17900 SK-M-423 SK 24400 SK-M-783 SK-13805

-24401

-13802

-24402

-13410

-24403

-13800

-24405

-13808

-24406

-24407 SK-M-784 5K 13805

-24409

-13802

-24410

-13410

-35242

-35516

-35415

-13400

-35528

-13408

-24414

-35528 SK-M-785 sK 13805

-15912 SK-M-824 FK-24500

-13802

-24501

-13406

-24502

-1'410

-24503

-13407

-24504

-13409

-14505

-13404

-24506

-24507 SK-M-786 31-13804

-24508

-35497

-24509

-14510 SK-M-787 31-15600

-15601 FK-M-825 EK-24601

-15602

-24602

-15603

-24603

-15604

-24604

-15605

-24605

-15606

-24606

-15607

-14607

-15608

-24608

-15609

-24609

-15610

-24611

-15611

-15612 SK-M-826 sK-24700

-15613

-24701

-24917

-14702 24703

$K-M-788 SK*15700

-247D4

-15701

-24705

-15702

-32077

-15703

-24706

-15704

-24707

-15705

-24708

-15706

-24709

-15707

-24710

-15708

-24711

-15709

-24713

-15710

-24712

-15711

-24714

-15712

-15713 SK-M-827 EK-24715

-15714

-24716

-28206

-24717

-14718 jf) p7g

-24719 0$l$fjilQ 802 183 I

I

~

~

Ps8e 12 of 12 SK-M-829

$K-26800 M-178 SK-6416

-26801

-M06

-26802

-6400 26803

-M07

-26804

-MO8

-26805

-6401

-26806

-MO9

-26807

-6405

-26808 6403

-26809

- A92

-26810

-M10

-26811

-6411

-26812

-M12

-1924

-M04

-1925

-6413

-6415 SK-M-831 SK-28204

-4069

-1926

-4071

-1927

-4072

-4074 SK-M-832 5K-28205

-4058

-5919

-4063

-4065 SK-M-833 SK-3920

-4068 5921

-4056

-5922 4057

-5923 4086

-103

-4087

-5924

-4088

-4089 SK-M-839 sh 1 SK-34304

-33801

-34305

-33802

-34301

-33803 34302

-33207

-34306

-330 5

-34307

-33800

-34308

-33813

-33814 SK-M-839 Sh 2 SI-31807

-33812

-31806 33206

-31804

-33813

-31805 11803 31802

-31801

-31800 SK-M-839 sh 3 SK-33700

-33701

-33702

-33703 SK-M-839 sh 4 51-31700

-31701

-31702

-31705

-31703

-31706

-31707 sK-M-1086 SK-40294

-4919

-4917

-40289

-4916

-40292 40293

-40290

-40291

-27207 802 191

~

e

~

At'eh a"t 5 Page 1 of 14 HANGER SKETCH MJuBERS FOR UNIT 82 SKM-608 SH 19 SKM-608 SM 27 SK-2-1102 SK-36648 2-1108 2-167 2-1109 36649 2-1111 2-166 2-1120 2 165 2-1123 2-1 64 2-1117 2-163 2-1113 2-162 2-11:s 2-172 2-1133 2-176 2-1136 2-174 2-1134 2-173 509-608 SH 20 2 171 ~

SK-2 1639 2-172 2-1640 2-170 33128 2 169 2-1615 SKM-608 SH 28 2-1616 SK-2-1705 2 1631 2-1706 2-1641 2-1704 2-1629 2 1734 2 1628 2-17C2 2-1627 2-1703 2 1625 2-1700 2-1618 2-1701 2 1617 2-1712 2 1623 2-1713 2-1621 2-170S SKM-608 SH 21 2-1716 5K-2-1735 2-1715 2-1736 2-1717 2 1737 33543 1 1738 2-1714 2-1720 2-1711 2-1721 2-1710 2-1722 2 1709 2-1723 SKM-608 SH 29 2-1724 SK-2-1726 2-1725 2-1728 2-1727 2-1731 SKM-608 SH 22 2-1730 SK-2-1404 2-1733 2-1407 36633 1 1410 2-1732

. '.05 2-1719 2-1402 2 1718 2-1400 SKM-628 2-1412 SK-35815 2-1413 27166 SKM-608 SH 23 2-10602 SK-27114 2-10605 2-1614 27161 2-1612 35817 2-1613 2-10616 2-1611 27159 2-1637 2-10617 2-1636 2-10605 2-1638 2-10609 2-1632 27163 2-1635 271 64 2-1634 2-10614 SKM-608 SH 24 2-10615 SK-2-1417 27165 2-1420 2-10613 2-1426 3581f 2-1423 2-10618 2-1424 27162 2 1429 35377 2-1440 27160 2-1438 2-10608 2-1436 2-10601 2-1432 35376 2-1434 27158 504-6s8 SH 25 2-10612 SK-2-1306 2-10604 2-1308 27157 2-1 304 2-10611 2-1303 2-10600 2-1300 d

2-10607 27197 4

a 2-10606 2-1128 J

j I

2-10603 2-1138 2-10610 2-1129 2-1130

11:1 802 185

Page 2 of 14 HANGE1t $ KETCH NLMERS F00 UNIT d2 5m-629 SH 7 Sm-635 SH 2 SK-2-8C00 SK-13205 2-8001 13200 2-8002 13201 2-8003 13202 2 8004 13203 5 m-63 SH 2 13204

$K-33134 13206 5323

$m-660 SH 1 5324

$K-12S13 5321 12802 5314 12812 5322 12806 5318 12811

  • 5317 12805 5316 12807 25015 12803 5315 12802 5319 12801 5320 12804

$ m-634 SH 5 12800 SK-27105 24947 27106 3 0-660 $H 2 18448 SK-35392 18435 35393 18443

$ W 687 8444 SK-24950 gg 11908 3g447 35810 18436 11906 jg34 11905 18442 U303 18437 U MO 18433 M M2 18438 U NI ggg39 36496 18440 36495 18445 36575

$m-634 SH 6 3NU

$K 1 0]

13905 5m-702 13906

$K W O3 13904 10700 18410 27188 18408

$ W 703 18406 SK-33134 18407 2-16000 18405 2 16004 184M 2-16002 18411 36298 18414 2-16005 18417 36316 18415 36314 18414 36394 18413 36393 5 2-634 SH 7 27116 SK-5411 27100 M12

$ 2-704 5413

$K-27145 M04 35985 5405 36101 5414 35986 M06 36207 MI5 35981 pg7 27112 25015 36206 M08 36205 9 09 36204 5410 36203 36202 5403 36201 5402 36200

.5401 2-14300 5400 1430o 5 0-635 SH 1

$m-705

$K-13106 SK-27139 13102 36511 13103 36512 13105 36513 13104 36514 13101 36226 13100 365C2 M;> l 802 1 86-

~

Page 3 of 14 HANGER SKETCH NMERS FOR UNIT 82 50-705 (cont'd)

S W 714 SK-2-12800 SK-2-9302 2 12802 9309 2-12801 2-9301 2-12803 2-9312 36396 2-9311 27139 2-9310 SKM-706 9307 SK-2-6115 9308 2-6117 2-9305 2-6118 27108 2-6119 9306 35886 27108 S W 707 9301 SK 36145 2-9J01 36146 2-9304 36147 2-9300 36148 5 0 -716 36149 SK-36493 36150 2-11300 36151 2-11301 36152 27101 36153 2-11329 35982 S W 717 36154 SK-35178 33580 2-11325 SKM-708 2-11302 SK-2-7801 2-11303 36142 3-11304 36143 5 0-718 36144 SK-27103 27125 2-11326 27121 2-11305 2-7806 2-11306 2-7807 2-11328 2-7808 2-11322 2-7812 36504 2-7813 2-11307 2-7809 2 11308 2-7810 2-11310 2-7811 2 11323 36134 2-11324 36135 2-11309 36136 5 W 719 36137 SK-2-10013 36138 27110 36139 27182 36140 2-10014 36141 SKM-720

$ W 709 SK-2-10013 SK-27117 2-10011 2-15105 2-10012 2-15104 2-100C0 2-15103 2-10001 2-15102 2-10002 2-15100 2-10003 2-15101 2-100fx 36776 2-10035 36293 2-100}6 36314 2-10007 36310 2-10C08 36309 33586 27119 2-10(C9 SW710 33586 SK-33542 S W 721 36274 SK-2-8936 36506 2-8933 36631 2-8904 36273 2-8S00 36630 2-8501 36271 5 m-722 36529 SK-2-t3911 36267 2-13912 S W 711 2-13913 SK-2-8005 2-13914 2 8006 2-13915 2-8007 2-13916 27107 2-13920 2-13919 2-1.3918

  1. )

2 '.3917 t

2-13922 f

35557 L

I 802 18T

Page 4 of 14 HANGER 5xETOH NLMBERS FOR UNTT e 2 SKM-723

$KM-758 SK-27105 SK-2-15111 2-14509 36624 2-14908 2-15110 2-14907 2-15109 2 14906 36625 2-14905 2-15108 2-14902 2-15107 2 14904 2-15106 2-14903 27118 2-14901 S W 759 2-14900 SK-9909 5 6 724 9903 SK-27106 9902 2-15011 9901 2-15012 9912 2-15009 9900 -

2-15010 S W 761 2-15007 SK-9911 2-15008 9930 2-15006 9907 2-15005 9905 2-15004 9904 2-15003 S W 762 2-15002 SK-9912 2-15000 9922 2-15001 9925 SKM-725 9921 SK-27104 9920 2-23400 9919 2-23401 S W 765 2 23402 SK-33588 2-23403 9827 2-23404 9823 2-23405 9822 2-23406 9820 2-23407 9821 2-23408 9826 S W 730 9819 SK-2-22004 9825 2-22002 S W 766 2-22001 SK-33590 2-22000 9813 S W 732 9807 5K-2-13900 9808 2-13902 9809 2-13904 9806 2-13906 9812 2-13907 S W 772 SH $

36419 SK-2-303 2-23300 2-304 2-23301 2-306 2-23302 2-305 2-23304 33115 27104 2-302 S W 738 2 301 SK-36184 2-300 2-8911 S W 777 35990 5K-17601 2-8910 17600 2-8909 S W 779 2-8908 SK-20600 35988 20601 35989 20602 S W 739 20604 SK-2-9600 20605 2-9601 25015 2-ir602 20606 27146 20607 3

35987 20608

$KM-741 20616 SK-33100 20611 2-20700 20614 2-20701 20613 2-20702 20610 2-20703 20609 2-20705 25013 2-20706 20612 33586 S W 785 SK-15912 13805 13802 13406 13410 13407

]

pI 13409 I}i((

[

I (jJQ) jb)J jlh I

I 13404 5101-7 86 SK-13806 13807

-l1R QQ9 13809 35497 va 13804

Page 5 of 14 HANGER SKETCH NtP'3EPS FOR tPt1T #2

$ W 789 5W845 5H 2 "18%

"mt 15817 2-17101 15816 2-17102 15815 2-17103 15814 2-17104 15813 2-17106 15812 2-17105 15811 2-17107 15810 2-17108 15809 2-17109 15808 2-17110 15807 2017111 15806 2-17112.

15805 2017113 15803 2-17114 15802 2-17115 15a01 15800 SKM-845 SH 3 36132 SK-2-18714

$ W 790 2-18715 SK-15900 2-18712 15901 2-19713 15902 2-18711 15903 2 18710 15904 2-18706 15905 2-18707 15906 2-19708 15907 2 18709 15908 2-18705 15909 2-18704 15914 2-18702 15910 2-18700 15911 2-18701 35264 15913 5 0-845 SH 4 SK-2-1 U17 24916 2-17716 SKM-793 2-17715 SK-33549 2-17714 2-1833 2-17713 S W 794 2-17712

$K-2-948*

2-1 U11 2-946 2-17710 2-945 2 17709 2-944 2-17708 24916 2-17707 SKM-817 SH 35 2-17706

$K-2-13621 2-11705 2-13625 2-1 U 04 2-13641 2-17703 2-13620 2 17702 35818 2-17701 2-13f48 2-17700 2 26.2 SKM-856 2-13630 5K-2-19101 2-13631 2-19100 2-607 2-19102 2-13633 2 19103 2-13634 2-19104 2-13635 2-19105 28225 36750 2-2371 2-19118 Z-2301 2-19117 SEM-845 SH 1 2-19107 SK-2-18319 2-19145 2-18318 2 19143 2-18321 36755 2-19320 2-19138 2-18308 2-19137 2-18309 2-19136 2-18316 2-19128 2-18317 2-19140 2-18315 2-19127 2-18314 2-19126 2-18312 36749 2-18313 2-19123 2 18304 36751 2-18303 2-19125 2-18305 36752 2-18306 2-19148 2-18300 N

2-19144 I

fI

[

ff ff f

2-19145 J

2-19141 j

Ul gjj 2-19i42 p'

] 86

~

Page 6 of 14 HANGER $ KETCH WMBERS FOR UNIT 82 5xM-876 SH 1

$KM-880 SH 1 SK-2-12705 SK-2-9500 2-12713 2-9501 i

2-12714 2-9502 2-12715 2-9505 2-19025 2 9506 2-19026 2-9508 2-12713 2-9509 2-12716 2-9510 2 12717 36192 2 12718 2-9513 2-12719 2-9511 2-12720 2-0512 2 12721 2-9514

  • 36670 2-19038 5 2-880 $H 2 2-19037 SK-2-9700 2 19009 2-9701 2-19031 2-9702 2-19016 2-9703 2-19015 2-9705 2-19032 2-9704 2-19027 2-9706 2 19030 2.9707 2-19008 2-9708 2-19007 2 9710 2-19006 2.1711 2-19029 25879 2-19038 2-9709 2-19002 2-5712 2-19003

$ 2-880 $H 3 2-19004

$K-2-12107 2-19005 2-12100 2-12711 2-12102 2-12712 2-12101 2 12710 33520 2-12709 2-12103 2-12708 2-12104 36667 2-12105 2-12707 2-12106 2 12706

$ m-880 SH 4 36682 SK-2-12200 SKM-876 SH 2 2 12201 SK-2-12722 2-12202 2-12723 2-12203 36671 33554 2-17524 2-12207 2-17508 2-12208 2-17507 2-12209 2-17506 2-12204 2-17505 2-12205 2 17502 2-12206 2-17501

$ m-880 SH 5 2-17523 SK-2-9729 2-17500 2-9730 2-17511 2 9731 2-17516 2 9732 2-17517 2-9733 2-17522 2-9735 2 17521 35880 2-17512 2-9736 2-9737

$KM-878

$ m-880 $H 6

$K-2-4102

$K-2-9713 2-16309 2-9714 2-4101 2-9716 2-16310 2-9718 2-4100 2-9719 2-4104 2-9720 2 16317 33531 2-4105 2-9721 36660 2-9722 l

2-16305 2-9723 2-16306 2 9728 2-16304 2-9727

+

2-16303 2 9724 2 16302 2-9725 2-16301 2-9726 2 16300 SKM-879

$K-2-16312 2 16313 2-16314 i

PR03 Ong;

  • 2 *

~

Page 7 of 14 HA MER SKETCH NUMBERS FOR UNIT 82 Sm-881 5 0-890 SK-2-16405 SK-27108 2-16406 36155 2-16407 36156 2-16408 35157 2-16410 36158 33556 36159 2-16412 36160 2-16413 36161 2-16411 36162 2-16400 2-13301 2-16401 2-13302 2 16402 36163 2-16409 2 13303 2-16427 36164 2-16403 36165 2-16404 z7124 Sm-882 27152 SK-33553 5 m-891 2-17203 SK-33589 2-17202 35910 2 17201 35909 2-17200 35908 SWSS3 SH 1 35907 SK-2-16100 35906 2-16101 35905 2-16102 35904 2-16103 35903 2-16104 35902 2-16105 35901 2-16106 35900 2 16107 33557 2-16108

$ m-892 SH1 36534 SK-2-10325 2-16110 2-10326 2 16111 2-10327 2-16112 2-10329 2 16113 2-10332 S G-883 SH 2 2-10331 SK-2-16116 2-10330 2-16119 2-10318 2-16109 2-10308 52-884 2-10337 SK-2-7002 2-10326 2-7003 2-10325 27147 2-10319 5m-885 2-10306 SK-2-17300 2-10338 2-17301 2-10310 2-17302 27148 2-17303 2-10309 27150 2-10301 27147 2-10302 5 m-886 2-10313 SK-2-12400 2-10323 2-12401 2-10324 2 12402 2-10316 2-12403 2-10317 2-12405 2-10314 2-12404 2 10307 2-12406 2-10303 5 m-887 2-10304 SK-2-7001 2 10315 2-7000 2-10333 27149 2-10334 S m-888 5 % 892 SH 2 SK-2-17400 SK-i7140 2 17401 2 '0311 2-17402 2-1J335 2-17403 2-10'12 2 17404 2-103 5 27149 27125 5 m-889 2-1030 a SK-2-5911 2-WO 2-5912 Sm-893 2-5913 SK-33556 I

2-5909 2-20308 2-591r 33555 2-5906 2-20302 2-20301 2-20300 2-20304 9I 1

]1 2-20305 Di

.,, li n k}'l.a y 2-20306 2-20307 g

2-20303 802 19

~

Page 8 of 14 HANGER $KETOM NUMBER $ FOR UMT 82 SKM-894 S W 906

$K-2-33580 SK-27167 2-16414 2-100 2-16415 2-101 2-16416 2-102 2-16417 2-104 2-16418 2-111 2-16419 2-105 2-16420 S W 907

$ W 895 5K-2-124

$K-33557 2-123 2-16422 2-121 2-16423 2-120 2 16424 2-119 2-16425

$m-908 2-16426 SK-27168 SKM-896 2-118 SK 27116 2-115 2-1619 2-116 27115 2-114 36683 2-112 2-1610 2-109 2-1609 2-107 2-1600 52-909 2-1601 SK-2-1025 2-1642 2-1026 2-1602 2-1024 2-1603 35837 2-1604 2-1023 2-1605 2-1014 2-1606 2-1010 2-1607

$ W 910 2-1608 SK-2-183 27171 2-131 2-1100 2-179 2-1140 2 180 2-1105 2-13642 2-1135 3 2-911 SH I 2-1101

$K-2-1906 36571 2-1907 Sm-898 2-1911 SK-2-12300 2-1909 2-12301 2-1910 2-12302 2-1900 2-12303 2-1901 2-12304 2-1902 2-12306 SKM-911 SH 2 S W 899 SK-2-1915 SK-27140 2-1914 2-5900 2-1913 2-5901 2-1912 2-5902 2-1925 2-5903 2-1926 2-5904 2-1916 2-5905 2-1917 2-5906 2-1918 2-5907 2-1919 27141 2-1920 S W 900

$ m-911 SH 3 SK-2-5914 SK-2 907 33536 2-913 2-5922 2-914 2-5921 2-916 2-5919 2-918 27194 2-929 2-5920 2-924 2-5903 2-921 2-5917 2-916 2 5916 2-918 2-5915 5 m-911 SH 4 27140 SK-27167 Sm-905 2 1806 SK-2-1000 2-1808 2-1003 2-1810 l

2-1005 2-1804 2-1008 2-1814 2-1007 2-1825 2-1021 2-1823 2-1018 2-1819 2-1022 2-1818 27193 2-1827 hh D IEll E

27192 2-1830 URhl#1

!=

802 192

Pa9t 9 of 14 MNGER SKETCH NUMBERS FOR UNIT 82 S W 911 SH $

S W 928 SK 2-905 SK-2 21300 f.f4o 35253 2-21301 2-935 35252 2-937 2-21302 2 932 2~21303 2 900 2-21304 27177 f,}l2 27112 2 7195 36431

$m-912 36430

$K-2 11202 36429 2-11201 3Mf8,

2-11204 g

2-11205 36426 SKM-913 SK-2-19303 5 W 929 2-19300

-25602 5 % 914 Sm-931 SK-2-13644 SK-2-15114 f'136 2-15115 2-15116 2-13647

$m-932 2-13648 SK-2-15112 hf6 33521 2-15113 2-32404 33532 2-32403 2-23209 32038 S m-933 2-32401 SK-2-23212 f.13$3 2 23211 2-13650 5 m-934 SH 1 32039 SK-2-20800 3'

2*20801 Sm-915 2-20802 SK-27153 2'20803 2-5201 2-20804 2 5202 2-20805 2-5200 2-20806 52-916 2-20807 SK-27145 2-20808 5 W 917 SK-35979 -

Sm 934 5H 2 35980 SK-2-20813 2-20812 3 6 2-22 H 35970 S m.g3$ $g j 35971 SK-2-2C7 37075

$9 2*202 35974 2-209 35975 2'21 0 35976 37076 35977 35978 2

-H 200 2-212 S m-918 SK-33550 S m-935 SH 2 2-1921 SK-2 200 3 m. gig 37074 SK-33551 2-1923 2-1924 S W 922 SK-2-6100 SK-33591 36523 2-21800 2-6104 2-21801 2-6105 2 2a302 2-6106 2-21403 0

2-21804 2-21805 2-6103 5 % 923 2-6102 SK-27122 2-6101 2-21100 24112 36479 2-6110 36478 2-6107 i

27115 P00RORISM mm w.-

Page 10 of 14 HANGER $Kli., pBERS FOR UW!? 82 S W 938 IH 1 SgM-941 SH 2 (cont'd) g 3E"f*

2 20005 2-20006 2-806 2-20007 2 804 2 2 WOO S W 942 2-20001 SK.2 853 2-20002 36645 3

  • I3 36644 SK-2-19908 2-19907 2 542 2-19906 2 540 2 19905 2-539 2-19904 2-538 2-19903 2 537 2-19902 2-535 2-19901 2-534 2-19900 2-533 2-19914 2-502 2 19915 2 531 2-19916 2-530 2-19913 32022 2-19911 2 513 2 19909 2 514 2 19910 2-515 2-19912 2-51 6 2-517 SK 36469 26468

-1 2-15200 2-520 36467 2-521 2-15202 2-522 36466 2 523 36425 2 524 36470 2 525 36471 2 526 36472 2 527 36473 2 528 36474 2-512 36475 2 511 36476 2-51 0 36477 2-508 2-507 SK-32021 2441 2442 2 504 2443 2 500 2446 2 502 2-501 2-848 2-844 SK-2-17829 2 845 2 17828 2-837 2 17805 2 838 2-17804 2 839 2-17807 2 a40 2 17808 2-850 27179 35254 2 19819 2-849 2-19820 2-852 2 19816 2-19817 SK2-802 2-800 25 32021 2-19823 2-817 2 19824 '

2-818 2 19804 2-819 2 19810 2 821 2 19811 2-822 2 19825 2-823 2-19801 2 824 2-19814 2-825 2 19826 2-826 5 3 943 SH 2 2-827 SK 2-16208 2-828 2-16207 2-830 2 16206 2 831 2 16205 2-832 2 16204 2 833 2 16202 2-816 2-16203 2-83e 2 16201 2-833 2 16200 2-815 2-17811 2-813 2-17801 h008'} l T

2-814 O

2 17800 t

3 2-17809 2.Bu 2-807 NI IL.

35802-194 2 809 2-17834 6

e-Page 11 of 14 MAN 09 SKETCH NL*?RS FOR tptTT 42 5 2-943 SH 2 (cont'd) 5 2-946 SK-2-16200 SK-2-36218 33593 2-24400 2-17824 2-24401 2-17822 2-24402 2-17823 36231 2-17835 36219 2-17831 2-24400 2 17832 2-24404 2-17820 2-24406 2 17817 2-24407 2-17818 2-24409 2-17815 36248 2-17836 36249 2-17814 2-2441E 2-17813 2-24414 2 17830 2024411 2 17837 2-24408 5 0-943 SH 3 2-24415 SK-33587 2 24416 2-16242 2-24417 2-16241 IU'947 2-16240 SK-2-24500 2-16239 35878 2-16238 2-24501 2 16237 2-24503 2 16236 2*24504 2-16235 2-24505 2-16234 2-24506 2-16233 2-24507 33592 2 24508 2-16226 2-24510 2-16227 0

2-16229 SK-2-24602 2-16228 2-24601 2-16232 2-24605 2 16230 2 06 5 0-943 SH 4 2-24604 SK-2-19805 2-24607 2-19806 2-24608 2-19822 2-24620 2-19804 2-24614 2-16212 2-24621 2-19808 2-24616 2-19813 2-24615 2-19812 2 24617 2-16213 2-24618 2-16214 5 m-949 2-16215 SK-2-24701 2-16216 2-24700 2-16222 2 24702 2-16224 2-24703 2-16225 2-24704 2-16223 36266 2-16220 2-24705 2-16219 2-24706 2-16210 36265 S m-944 36251 SK-2-10705 2-24707 2-10704 36268 2-10706 2-24708 2-10708 36269 2-10707 36311

$m-9' SH 1 2-24710 5K-2-508 2-24711 i

2-605 2 24713 2 604 52-950 SK-2-24718 l

2-609 2-24719 2-610 2-24717

$m-945 SH 2 2-24716 SK 2-60' f'52-952 SH 1 SK-2-2445 Z-603 2-21008 2-607 2-21009 35749 2-21010 2-618 2 2367 2-61g j

3 fa 35371 If' l f i

2-21012 g

35176 1

2-21011 802 195

Page 12 of 14 HANGER SKETCH NUMBERS FOR UNIT #2 SKM-952 SH 2 SKM-956 SK-2-2438 SK-35757 2-21207 2-1512 2-21214 2-E00 2-21206 2-1502 2-2428 2-1506 2-2440 2-1516 2-2426 2-1510 2-21204 27196 2-21205 27119 35177 SKM-957 SKM-952 SM 3 SK-35836 SK-2-21215 2-18100 2-21213 2-18105 2-2434 2-18107.

2-21211 2-18101 2-21212 2-18102 2-21210 2 18103 2-21202 2-18104 2-21203 27143 2-21208 2-18108 33115 SKM-958 SKM-952 SH 4 SK-2-18610 SK-2-21001 36592 2-21000 36593 2-21004 36594 2-21002 36595 2-21003 36596 2-21005 36597 2-21006 2-18611 SK%953 27103

$K-27126 2-16609 2-8100 2-18507 2-8102 2-18606 2-8103 2-18608 2-8104 2-18605 2-8105 27126 2-8106 35590 2-8107 36589 2-8108 36588 33543 36587 33544 36586 2-810, 36585 2-8111 27123 2-8110 2-18602 SKM-954 36584 SK-32099 35836 2-140 5 % 959 2-139 SK-35175 2-138 36460 2-136 36433 2-134 36434 2 133 2-18900 2-132 36435 2-1 31 36437 2 130 36438 2-125 27155 2-126 2-18903 2-127 35178 2-128 36439 2-158 36440 2 132 36441 27196 36442 2-129 36461 SKM-955 36443

$K-2-142 36444 2 141 36445 32099 36392 2-143 SKM-C60 36409 SK-27101 2-146 2-1203 2-148 2-1200 2-149 2-1202 2 150 2-1208 2 151 SKM-961 3M83 SK-33583 27114 36222 2-155 36223 2-160 36224 2-153 36225 2-144 g

I l

f gf 36227 36226 2-145 i 9 b

DS e

802 196

Page 13 of 14 H4 %ER 3rtTcw M M ER$ ron UNIT #2

$m-962 SH 1 5 0-986 $H 2

$K-27188 5K-2-31700 33566 2-37101 2-23206 2-37102 2-23205 2-31703 33567 2-31704 24028 2-31705 2*23218 2-31706 S W 962 SH 4 5 W 986 $H 3

$K-2 23200 SK-2-31800 2442 1 2 31802 2+232W 2 31801 2-23202 2 31803 S W 963 2 31804

$K 2-2EE5 2-31805 2 22006 2-31806 2 22007 t w e96 2-22008

$g.35343 36464 5108-99

S W 964 SK-35757

$K-36426 36451 36427 35450 36428 36463 35441 36449 36429

-'462 36430 36448 36431 26447 36635 36446 36432 36403

$m-966 j.102%

SK-2-18204 geggg 2*18203 2-It2C2 35836 2-10203 2-18201 2 10204 2 18202 2-2604 2 j

$ W 967 5

SK-2-26800 2132 2-26801 36402 2 26802 ggggg 2*26803 SK-2-5700 2 26804 2-5701 2-26805 2-5703 2 26806 2-5702 2 26807 2-5800 2*26808 2 5801 2-26813 2-5802 2 26812 2-5803 2-26810 2-5804 S W 981 2-5G05

$K-2-5300 2-5806 2 5301 2-5807 2-5302 2-5809 2-5303 2 5808 2-5304 g,$g)g 2-5305 2-5811 2-2615

$ W 1000 SH I i:ia 5x-;m2 2-261f 36410 2-5308 Z-6502 2 5309 2-6503 2-2619 35793 2-2520 36247 2-2622 2-6500 2-5312 2-6501 2-5313 M404 2 5315 5W1001 I*~2 5W986 SH 1 2 702 SK-2-34300 2-6701 2 34301 2-6700 2-34303 36650 2-34304 36642 2-34308 S W 1002 2-34305 SK-35886 2-34310 2-11500 2 34307 2-11504 2'34308 2-11501 2-11505 2-11502 2 11503 PDMI US$h[

2 11506 h

2 11507 802 to7

Page 14 of 14 HANG'R SKETOM NUMBERS FOR UNIT #2 S W 1019 5 W 179 (cont'd)

SK-2-13005

$x 2-6270 2-13008 2-6271 2 13004 2-6272 2-13009 2-6273 2-13010 36651 2-13011 36654 36183 36653

$KM-1020 35249 SK-2-11600 2-6258 2-11601 2-6259 S W 1023 2-4020

$K-36424 2 4021 2-12700 24069 2-12701 2-4070.

2 12703 2-4071 2-12704 24066

$KM-1048 2-4067 SK-36979 2-6337 36888 2-6238 36887 2-4001 36886 2-4002 36885 2-4003 S W 1087 2-4004 SK 37083 2-4005 2-4937 2-40C6 37080 2-4007 27141 2-4003 2-4935 2-4009 37002 2-4010 37081 2-4011 SKH-1600 SK-2-28109 36637 2-11835 2-11836 36641 SKM-1601 SK-36647 36658 36659 2 28112 36638 36665 5xM-179 SK-2-6400 2-6401 2-6402 24403 2-6404 24405 24406 24407 2-6409 2-6410 2-6411 2-6412 2-6288 2-6287 2-6286 2-6285 2 6246 2-6242 2-6240 2-6243 2-6278 2-6277 2-6276 2-6275 2-6248 2-6247 2 6254 24255 2-6245 2-6244 2 6256 2 6250 2-6257 2-6260 2-6251 4

l

'j

  1. ' N t 2-6253 2-6262

< Jf'h[ ag,,

I*

36652 18%

802 198

)

Attachinent 6 1.

1 VALVE 1.15T Fot UNITS I & 2 I of 6 BFCNTEL MARK NO.

VEMX1R VFNDI4 DWC NO.

DESCRIPfl0N BEVISION g

BrMBKS 29 & 29C MWELL M-2743 2h" - 150# CATE, B.W.

I UNKM WN CBANE M-2 74C 3" - 150# CATE. B.W.

UNKNUWN UNKMWN MWELL M-2743 3" - 150f CATE B.W.

I l-19-74 VELAN M-253 3" - 15CI CATE, B.W. N.cl II B

11-22-73 CRANE M-275N 4" - 150# CATE, B.W.

B l-12-72 MWEtt M-2743 4" - 150f CATE, B.W.

I l-19-74 WEIAN M-253 4" - 1508 CATE, B.W. N.Cl 11 8

11-22-73 VEIAN M-253 4" - 150# CATE, B.W. N.Cl Ill B

ll-22-73 VEIAN M-253 6" - 150# CATE, B.W. N.Cl 31 5

11 22-73 MWELL M-2 74B 6" - 1508 CATE, B.W.

I l-19-74 CRANE M-275N 4" - 150# CATE, B.W.

B l-12-72 1

MWELL M-2743 8* - 150# CATE, B.W.

I UNKNOWN VIEAN M-253 B" - 150$ CATE. B.W. N.Cl III B

11-22-73 VEIAN M-253 B" - 150i CATE B.W. N.Cl Il C

12-21-73 FtWELL M-2743 10" - 150# CATE, B.W.

I l-19-74 FACIFIC M-275N 10" - 150f CATE, B.W.

UNKMWN UNKNtWN C-29 MWELL M-2745 10" - 150# CATE, B.W. (17.5' CNAIN)

I l-19-74 FuWELL M-2 745 10" - 150# LATE, B.W. (21' OlAIM)

I l-19-74 MWELL M-274B 10" - 150f CATE, B.W (It' QtAIN)

I l-19-74 MWELL M-274B 10" - 150# CATE B.W. (6' QtAIN)

I l-19-74 FACIFIC M-275W 10" - 150# CATE, B.W.

UNKNLMN UNKNOWN 14 FCWELL M-2753 4" - 600# CATE, B.W.

4 UNKNOWN OtArMAN M-275A 4" - 6008 CATE, B.W.

UNKJeUWN UNKNOWN VEIAN M-253 4" - 600# CATE. B.W. N.Cl 11 D

31 25-71 i

VEIAN M-253 4" - 600# CATE, B.W. N.Cl II B

11-26-73 VEIA N M-253 6" - 600# CATE, B.W. N.Cl II D

11-25-71 l

VEIAN M-253 6" - 6004 CATE, B.W. N.Cl 31 B

11-20-73 l

NMELL M-275B 6" - 600# CATE. B.W.

4 UNKNOWN 142 N1WELL M-2743 2h" - 1508 CIDaE, B.W.

I UNKNOWN CRANE M-275N 2h" - 150f CtDat, B.W.

A UNKNIWN NWELL M-2748 3" - 150f CIDBE B.W.

I UNKNOWN VEIAN M-253 3" - 150f cloBE, B.W. N.Cl II 11-22-72 BOCKWELL M-275N 10" - 3000 CIDBE B.W.

UNKNWN UNRMWN MWELL M-2743 10" - 1508 CILBE B.W.

I UNKNOWN 214 RnCEVELL H-275C 16" - S004 CHECE. TILT 1HG DISC, B.W.

B UNKM WN 218 utAFMAN M-275A 4" - 600# QlECE, TILTING DISC. B.W.

UNKM WN UNKNOWN O-QLAPMAN H-275A 6" - 600# CHECK. TILTING DISC, B.W.

UNKM EN UNKHLEN

(. )

223 VEIAN M-235 2" - 600# QIECE. LIFT 1TFE, B.W.

UNKNOWN UNKNOWN 233 MWELL M-2745 2h" - 150# QtECK, SWING, B.W.

I UNKMWN VEIAN M-253 3" - 1508 QiECK. SWINC. B.W. N.Cl II UNKNLWN UNKM WW l

NMELL M-2 743 3" - 150# CllECK, SUING, B.W.

I UNKNt WN i H

((

Q VEIAN M-25 3-18 6" - 1505 OIECK SWINC B.W. W.Cl 11 UNKMWN UNKNUWN

[

RWELL M-2748 6" - 150d CHECK, SWING. B.W.

K 12-24-73

},

,g VEIAN M-253 6" - 150f OlECK. SWING, B.W.

UNKNOWN UNKNOWN NMELL M-2748 B" - 150I OtFCK. SWING. B.W.

I UNKNOWN VEIAN M-253 8" - 150# CHECK SWING, B.W.

UNKNOWN UNFNOWN w

257 CBANE M-28 38 30" - 125# SWING OIECK. FIED UNKMWW UNKMUN

T25

.C." g3 1

COEE

~

CD CM i

C:3 C3 ca 5l5:==55g=g:5.4 4. 4.!.$.E 4.H 4.g 5 5 5 5 8

. B i.l.I $ h g ::4. 4. 4. 94..g = ~ 5:~ = 44.g :N4.g=4

= =g ex

=

=

.B 4. 4 9 4. 4..I4. 4 4..

E

.=

E 5.. 5 5$ !.l 55l"5.g$...

lo

=

n 3

a-a-aa-aa.

ou E

5 4

4 4itEBB C

o...

- sss3 s 3

- 33uuuu O

..ggaa g :."g":..====

==

re re EsB

-~

E 55555, E $$$ BB55BE 5 naegal.gggga*33u0EE3333 BB B UU 2

8

- ss.

sa=== O a

e

..ss MMMMMMMMM;4

. sss M C

g2 ed.

M9 MM M M 444 g :g== ca===s g :-.44 e

engge

... e ge0eg0 i gg ::53535355:::::e e :: :

gag g a

s 3

e ge====

3 0

a m a.( 2

  • g U" 5. #

E.E da ad 3 3 oso C

33333 :

.g.

D E..$n~g 2:22:R23 3 g..

g 3 333-gg 8: RR R 8

.32

.. ~.~.~.. 3333 2

" " ". ". " " ". ". ".,. ".. ~. ~. ~ ~.

~~

aa ::=

x Ass -.... =. ::..

assa: 2

saa55 :: a 5: 5 A aas s E

5

! exe:4 : : ::: :::::: = :::= :::::::::= :: : : ::: :

5

~~~~7

~

~7~

~~~~~~ ~ i-~~ ~~~~~i~~~~ ~~ ~ ~ ~~~ ~

~

$ zzzzz z z zzz zzzzzz z zzzz zzzzzzzzzz zz z z zzz z C # CCC ##CCCC D j jb4 N

-ens = 2 2 n..sa 2aslas E r))]. ]gsm,c$.c].$4 4} b 4 3 rg $

~

a 5

W.

E

>o.s*

szz z s

E:

2 3

5 n

~K o

3 3n K

2 z

a

=

0 5

~

o

. ~

~

o -

802 200

3 et 6 SEnf7TL MARK NO.

VENDOR YENDOR I4C NO.

DESCIIFTION REVISION E

SFNABFS SI 215 ATWOOD & mRAIII H-733-2 12" - 1500# OLECE 3.W.

6 5-07-73 See 207 M3 SI 225 ATWOOD 6 maRIII H-733-2 12" - 1500# a:ECE 3.W.

6 5-07-73 See 207 M3 SI 235 ATWOOD & Homalti H-733-2 12" - 1500# QiECE s.W.

6 5-07-73 See 207 M3 SI 245 Atwoon & MDRatti M-733-2 12" - 15000 atECK s.W.

6 5-07-73 See 207 M3 SI 217 VEIAN M-7 3 3-3 12" - 1500# otECK 3.W.

A 8-14-70 See 207 M3 SI 227 VEIAN M-733-3 12" - 1500# a ECK n.W.

A 8-14-70 See 207 H3 SI 237 VELAN M-733-3 12" - 1500# c4ECE 3.W.

A 8-14-70 See 207 M3 SI 247 VEIAN M-733-3 12" - 15007 CHECK B.W.

A 8-14-70 See 207 M3 210 M3 VEIAN M-285 2" - 1500# OtECK S.W. N. CtASS I E

11-05-74 VEIA N H-285 2" - 1500# O!ECK S.W. N. CtASS 2 E

11-05-74 ROCKWEli H-2853 2" - 1500# atECE S.W. N. CIASS I UNKNOWN tmKmMN SF 210 M3 VEtAN M-285 2" - 15007 CHECK S.W. N. CLASS 1 E

11-05-74 VEIAN M-285 2" - 15007 CHECK S.W. N. CIASS 2 E

31-05-74 SI 405 VEIAN M-733 8" - 900# ciECK t.W.

s 10-11-70 See 214 M3 SI 427 VEIAN M-733 8"

900# otECK a.W.

a 10-11-70 See 214 M3 SR 414 VEIAN M-733 8" - 900# QtECK B.W.

3 10-11-70 See 214 M3 234 M3 VtLAN M-281 8" - 300f DIECK S.W. N. CIAS$ 2 g

12-24-73 VEIAN M-281 8" - 3005 OtECK S.W. N. CIAS$ 2 K

12-24-73 See 235 M3 238 M3 VEIAN M-281 2h" - 150# cucCK 3.W. N. CIASS 3 E

12-24-73 VEIAN M-281 3" - 150f atECE 3.W. N. CIASS 2 E

12-24-73 VEIAN M-231 3" - 1508 Q!ECK B.W. N. CIASS 3 K

12-24 73 FUWELL M-279 3" - 150# OtECK B.W.

C UNKNOWN VEIAN M-281 4" - 150f a:ECK B.W. N. CIASS 3 K

12-24-73 FtMEli M-279 4" - 150# OlECK 3.W.

UNKNOWN UNKNOWN VERAN M-281 6" - 150# clECK 3.W. N. CIASS 3 K

12-24-73 VEIAN H-281 8" = 150# QtECK B.W. M. CIASS 2 E

12-24-73 VEIAN M-281 8" - 150# QlECK 3.W. N. CIAS$ 3 K

12-24-73 VEIAN M-281 18" - 150e otECK B.W. N. CIASS 2 P

4-05-71 VEIAN M-281 24" - 150# QtECK B.W. N. CIASS 2 P

4-04-71 427 M3G FRATT M-298 8" - 8 50# BUTTERFLY, FIAICELESS, N. CLASS 2 1

4 20-71 428 M3C PRATT M-298 8" - 150# suTTERFLY. FIANCE!ZSS, N. CtASS 2 UNKNUWN UNKNOWN 2-HOV-403 VEIAN M-282-3 2h" - 15007 CATE M(N. OP.

E 2-26-74 P-34702-3 2-Mov-405 VEIAN H-282-3 2h" - 1500# CATE M 4. OF.

E 2-26-74 P-M702-3 2-MOV-501 VE LAN M-6tt-42 4" - 150# CATE MN. OF.

NONE 2-11-70 P-34657-3 2-HOV-504 VEIA N M-611-43 3" - 150# CATE HOT. OF.

NONE 2-10 70 P-34657-4 (p

2-MOV-508 VEIAN M-631-41 3" - 1508 CATE NOT. OF.

mmE 2-10-70 P-34657-5 2-MOV-509 VEIAN M-631-41 3" - 150# CATE HOT. OF.

NONE 2-10-70 P-34657-5 1C 2-mV-514 VEIAN M-631-41 3" - 1508 CATE Muf. OF.

Nt*E 2-10-70 P-34657-5 Q

2-HOV-614 VFIAN H-282-1 12" - 1500# CATE MOT. OF.

C 2-27-76 P-34702 2-HuV-615 VEIAN M-631-45 6" - 1500# CA11 HOT. OF.

NONE 2-12-70 P-34657-2 2-MOV-616 VEEAN M-611-44 2" - 1500# C14BE HOT. OF.

NONE 2-07-70 P-34657-1 2-MOV-624 WEtAN M-282-1 12" - 1500# CATE NOT. OF.

C 2-27-76 P-34 702 N

2-MOV-625 VEIA N M-631-45 6" - 1500# Clone HLFT. OF.

HONE 2-12-70 P-34657-2 2-HoV-6 %

VELAN M-282-1 12" - 1500f CATE Huf. OF.

C 2-27-76 P-34702 O

2-MOV-635 VELAN H-631-45 6" - 1500f CIDBE NOT. OP.

HONE 2-12-70 P-34657-2

- = = * "

2-IloV-644 VEIAN M-282-1 12" - 1500# CATE NOT. OF.

C 2-27-76 P-34 702 2-HOV5 VEIAN M-611 45 6" - 1500# Cimas nn. OF.

NimE 2-12-70 P-34657-2 300R ORGE

s 4 et 6 BEGITEL MARE No.

VTNivlt VFHFOR IWC NO.

gESCRIFTION BFVISION DAH R_WS 2-How-651 VEIAN H-282-1 12" - 1500f CATE NOT. OF.

C 2 27-76 P-34702 2-w ry-652 VEIAN H-282-1 12" - 1500# CATE HOT. OF.

C 2-27-76 P-M 702 2-Hov-653 VETAN H-641-46 4" - 900$ CATE HUT. OF.

MONE 2-14-70 P-34657-6 2-MHV-654 WEIAN H-611-62 6" - 900# CATE HOT. OF.

C 3-10-70 P-M65 7-8 2 -Hi'V-65 3 VEIAN H-631-46 4" - 900# CATE NOT. 07.

NahE 2-14-70 P-34657-6 2-mV-656 VEIAN H-631-62 6" - 1500f CATE HOT. OP.

C 1-59-71 P-34657-7 g

2-mV-658 VEIAN H-281-10 12" - 3007 CATE HOT. OP.

C 2-20-73 P-34701-6 2-H0V-659 VELAN H-281-7 4" - 900# CATE HOT. OP.

C 2-27-76 P-M 702 2-MOV-660 VItAN H-281-7 4" - 9007 CATE HDT. OF.

C 2 27-76 P-34702 2-mV-662 VELAN H-281-10 4" - 300# CATE HOT. OF.

C 2-20-73 P-34 701-6 2 -Pa lV-66 3 VEIAM H-281-10 4" - 300# CATE HOT. OF.

C 2-20-73 P-34 701-6 2-HuV-4070 WEIAN H-25 3-2 3 6" - 600# CATE HOT. OF.

D 6-18-73 2-HOV-4071 VEIA N H-253-21 A" - 600# CATE HOT. OP.

D 6-18-73 2-HuV-4142 VEtAN H-28I-9 th" - 1508 CATE HL7f. OF.

9 No DATE 2-tt)V-414 3 VEIAN H-281-9 18" - 150f CATE HOT. OF.

6 No DATE 2-m)V-4144 VEIAN H-281-9 24" - 1500 CATE HUT. OF.

B No DATE 2-MOV-4516 VEIAN H-253-2 16" - 900# CATE N07. OP.

NO INFO 900 DATE 2-HOV-4517 VEIAN H-253-2 16" - 900# CATE ttyt. OF.

NO INFO No DATE 2-Hov-5250 PRATT H-297-22 6" - 150# BUTTERFLY. HDTOR OPER.

A 9-30-75 2-H0V-5251 FRATT H-297-22 6" - 150f BUTTEkFLT. HOTOR OPER.

A 9-30-75 e

2-CV-210X l.T.T.

H-631-37 1%" - 150# CtanE 4

UNFNOWN 2-CV-100E I.T.T.

H-611-24 3" - 1500# ANCLE VALVE 3.W.

6 7-03-74 2-CV-100F l.T.T.

H-611-24 3" - 1500) ANGLE VALVE 5.W.

6 7-03-74 2-CV-223 FISHER H-288-96 6" - 150# DIAPHRACH ACT CV B

2-11-71 2-CV-306 HASQNEllAN H-293-SI 12" - 300f CIDBE UNKkWN UNKNOWN 2-CV-312 1.T.T.

H-631-32 3" - 150f clost B.W.

4 UNKNOWN I

2-CV-657 M&SQNEltAN H-293-51 12" - 3005 CIDBE UNKNOWN U NKNOWN 2-CV-1579 FISalER H-288-82 2" - 600# CIDaE S.W.

C 6-11-64 2-CV-1565 FISitER H-288-122 2" - 1508 CIDBE S.W.

C 6-12-68 2-CV-1581 FISHER H- %4-4 8" - 150# BUTTERFLY UNKNOWN UNKM WN 2-CV-1582 FISHER H-304-3 8" - 150) SUTTERFLY UNE *WN UNKHLWN 2-CV-1581 FISHER H-304-2 4" - 1500 BUTTERFLT UNKRMN UNFANN 2-CV-1584 FISHER H-304-4 8" - 150# BUTTERFLY L NKWWN UNKNOWN 2-CV-1585 FISUER H-304-3 8* - 150f BUTTERFLY UNEMWN UNKRWN 2-CV-1586 FISHER H-304-2 4" - 150f BUTTERFLY UNKM EN UNANUWN 2-CV-1587 HASQNEllAN H-301-5 6" - 150f BuTTERIT.T UNKM WN UNKMWN 2-CV-1589 FISHER H-304-4 8" - 150# BUTTERFLY UNEWWN UNKmWN 2-CV-1590 FISHER H-304-3 8" - 1508 BUTTERFLY

'JNKmWN UNkNLWN 2-CV-1591 FISHER H-304-2 4" - 1500 BUTTERFLY UNKmWN UNEMWN 2-CV-1592 FISHER H-304-4 4" - 1507 BUTTIRFLY UNKNOWN UNkmWN Q

2-CV-1593 FISilER H-304-3 8" - 150# BUTTERFLY UNKN4WN UNEM WN 2-CV-1594 FISHER H-304-2 4" - 150# BUTTERFLT UNKMUN UNKM WN 2-CV-1600 ANNIN H-303-Il 14" - 150# BUTTERFLT H

7-11-69 2-CV-1638 ANNIN H-303-32 14" - 150# BUTTERFLT H

7-it-69 2-CV-3823 MASON-NEllAN H-303-40 10" - 150# BUTTERFLY. FtANCELESS UNKWWN UNKRMN N

2-CV-3824 ANNIN H-30 3-9 16" - 130# BUTTERFLY. FEANCELESS N

7-17-69 Q

2-CV-3825 NASON-NEILAN H-303-40 10" - 150# BUTTERFLY. FRANCELESS UNENtWN UNE NLWN 2-CV-3826 ANNIN H-30 3-9 16" - 150# BUTTERFLY FEANGELESS II 7-11-69 2-CV-3828 ANNIN H-303-9 16" - 1508 BUTTERFLT. FLANCEIISS N

7-17-69 2-CV-3830 ANNIN H-303-9 16" - 150f BurrERFLY. FIANGELESS N

7-ff-69 2-CV-1832 FISHER H-304-1 10" - 150# BUTTERFLY. FIAEE11SS NONE MINE 2-CV-3833 FISHER H-304-1 10" - 150f BUTTERFLY FIAEELESS NONE MONE 2-CV-3938 BIAW-ENOI H-292-2 5" - 600# CIDBE B.W.

a 11-07-73 2-CV-3939 S TAW-Km1 H-292-2 5" - 600# CIDBE B.W.

4 11-07-73 P00R BRGlWL

5 et 6 BECHTYL HARE NO.

}TNDnt VEM ot IWG. NO.

DESca t rilON RFVISION p_A3 RDtApt3 2-CV-4043 SOCEWELL H-273-7 34" - 600f MAIN STEAM 150. VALVE B

UNEmWK 2-CV-4048 90CEWELL H-273-7 34" - 6JOS HAIN STEAM 150. VALVE B

UmmWN 2-CV-4150 FASON-NEllAN H-293-25 8" - 150#, CIDat B.W.

MONE WMdE 2-CV-4151 FASON-NEllAN H-293-25 8" - 150#, CIDet B.W.

MONE MmE 2-CV-4159 FASON-MEllAN H-29 3-33 4" - 1508 CATE B.W.

    • E MmE 2-CV-4160 FASON-NEllAN H-293-33 4" - 150#, CATE 3.W.

MtmE NOME 2-CV-4511 FASON-NEl[AN H-293-17 3" - 600f, Cimar. B.W.

NONE MONE 2-CV-4512 FASON-NEIIAN H-2 9 3-17 3" - 600#, CtDBE B.W.

mmE mmE 2-CV-5149 H-297-23 30" - 1258 BUTTERFLY, Ft4D UNKMLMN UNE NuWN 2-CV-5150 H-297-23 30"

'25# BUTTEBfU, FILD UNKNOWN UNEMEN 2-CV-5152 H-297-2 3 30" - 125# BUTTERrLY, Fl4D UNKNtWN UNEmWN 2-CV-5153 H-297-23 30" - 125# BUTTERFLY, FIED UNKM WN UNKNOWN 2-CV-5155 H-297-23 30" - 125# BUTTERFLY, FILD UNEMWN UNKNOWN 2-CV-3156 H-29 7-2 3 30" - 12H BUTTERFLY, FILD UNKRMN UNKNOWN 2-CV-5160 H-29 7-2 3 24" - 125# BU1TERFLY, FIED UNKhWN UNEMMM 2-CV-5162 H-297-23 24" = 125# BUTTERFLY, FIED UNKmWN UNKmWN 2-CV-5163 H-297-23 24" - 1254 BUTTERFLY, FIED UNKNUWN UNKMMM 2-CV-5165 H-297-2 3 24" - 125# FA1TERFLY, FILD UNKMWN UNXMMI 2-CV-5166 H-297-23 30" - 1252 $UTTERFLY, FIED UNkWWN UNKNLEN 2-CV-5170 M SONEllAN H-30 3-38 8" - 1508 BUTTERFLY UNKetWN UNEMEN 2-CV-5171 mSONEIIAN H-303-38 8" - 150# BUTTERFLY UNKROWN UNEWWN 2-CV-Sl73 M SONEIIAN H-30 3-38 8" - 1508 BUTTE 8 FLY UNKN WN wNENLWN 2-CV-5174 MSONEllAN H-303-38 8" - 1500 BUTTERFLE UNKN WM UelE NtWN 2-CV-5175 MSONEllAN H-301-38 8" - 150# BUTTERFLY UNKN WM tsHKHLWN 2-CV-5t?7 mSON-NEllAN H-303-39 8" - 1508 BUTTERFLY N

UNKNLWN 2-CV-5178 HnSON-NEllAN H-303-39 8" - 150# BUTTERFLY N

UNKNtWN 2-CV-5206 FttATT H-2 9 7-2 24" - 125# BUTTERFLY UNERMN UNENLWN 2-CV-5208 FRATT H-297-2 24" - 125# BUTTERFLY ONENOWN UNEM WN 2-CV-5209 FfSHER H-284-2 30" - 1258 BUTTERFLY Is 3-23-77 2-CV-5210 FtATT H-297-2 30" - 1257 BUTTERFLY UNENOWN UNE2WN 2-CV-52t?

FDATT H-297 2 30" - 125# BUTTERFLY UNKNOWN UNFNt WN 2-CV-52I4 FISutR H-284-2 30" - 125# BUTTERFLY D

3-23-77 2-ERV-402 D5 ESSER H-668-3 2h" - 2500# ELECTROHATIC RELIEF VALVE 2

12-02-70 2-ERV-404 DRESSER H-668-3 2h* - 25003 ELECTROHATIC RELIEF VALVE 2

12-02-?O 2-SV-4952 DRACOM H-377-5 3" SOLENOID CIDBE VA*.VE F

6-17-74 10190 2-SV-4953 DsACON H-377-5 3" $0tJN0!D CIDBE VALVE F

6-57-74 10190 2-SV-4954 DRAGON H-377-5

"** SOLENOID CIDBE VALVE F

6-17-76 10190 2-SV-4955 DBACnN H-377-5 Y' S0t.ENGID CID5E VALVE F

6-17-74 10190 2-SV-4956 UBACON H-377-3 3" SOLINOID CIDBE VALVE F

6-17-74 10190 2-SV-4957 DRACON H-377-5 3" $0t1N010 CIDBE VALVE F

6-17-74 1.190 O

2-RV-200 nRESSER H-669 2 2h" to 6" HAIIrtIN SAFETY VALVE 7

1 7 *.

CF-1355 g

2-RV-201 DRESSER H-669-2 2%" to 6" HAXIFils SAFETY VALVE

.-.v-73 CF-1355 N

2-RV-376 H-306-8 3" SArETY REtiEr VAtvE A

NO DATE 2-RV-446 rRDS BY H-293-5 2h" to 4" N0ZZLE DELIEF VALVE B

3-15-72 N-55294 WCT 95#

2-RV-468

( ROSBY H-295-2 th" to 2%" H0ZZLE RELIEF VALVE B

3-15-72 N-55291 WCT 55#

2-RV-4501 IARRIS H-306-44 3* SAFETY RELIEF % 3E A

No DATE N

2-RV-4502 SARRIS H-306-44 3" 8AFETY RELIEF VALVE A

NO DATE CD t.eJ -

g MWA

1 4

3 2222222222222222 h.h.hhh.hh..hhh.h.hh.hhh E

.:5:c.

b'

  1. C.O M',=a

.E.E.EE.E.E.E.E.Ef.E.EEE.EE

5===!=======

1111112211111111 CQde saaaaaaaaaaa::a::

-g aa a 2:2 2:2 2:2 2: '> ::

r l ass 020:bt2 03200 (CLe 20 assassassassa o

22:2 2:222:22:::

.E E E E E E E.E EE.E E E EE E

-~........

3333333:3332 333 E R 3 3 3 3 3 3 3 3 3 3 3 E E 3 ded@@@d@@@dede@d E

E

"""""~~~~~~"~~7" zzzzzzzzzzzzzzzz 25555555555555"5 2g22g

. EaSaag20:30g0003 3528sosias E

1 me:g_.~...-~ $..~

.23:3 8888 888 E ?????7??11111111 YYYYYY YIY7 YY Y W.

nn~~nn~~~~~~nn~n 802 204

~~

Attachment 'T 9

UNIT #1 CLASS I PIPING 2" AND UNDER

~]

SKETCH NO.

REVISION TITLE FSK-NT-489 H 11 Charging Line - Regenerative Heat FSK-MP-490 H4 10 Exchanger to Coolant Pump FSK-MP-491 H2 9

FSK-MP-492 Sht.1 H4 22 FSK-NT-492 Sht.2 H3 0

FSK-MP-581 H 10 Pressurizer Relief Valve Piping FS" HT-1019 H3 7

Inside Cont.

FSK-MP-455 H3 15 Letdown Line to Regenerative Heat FSK-MP-456 H5 9

Exchanger and Primary Drain Line FSK-MP-461 H 6

FSK-HT-576 H1 10 FSK-MP-1347 H 8

Safety Injection Piping System Tank FSK-NT-2331 HB 3

  1. 11A Leg llA, llB, 12A, & 12B FSK-MP-2329 HB 4

Safety Injection Piping System Tank

  1. 11B Les llB FSK-MP-2332 HB 3

Safety Injection Piping System Tank

  1. 11A Leg 11A FSK-MP-2330 HB 3

Safety Injection Piping System Tank

  1. 12B Leg 123 FSK-MP-575 H1 7

CC-9 & HC-2 Prirary Loop Drains Steam Gen. #11 FSK-MP-896-1 H 10 FDT Root Valve Details for Steam Gen.

  1. 11 C-9 FSK-MT-896 2H 10 PDT Root Valve Details for Steam Gen.
  1. 12 CC-9 FSK-Mf"714 H2 22 Reactor Coolant System Leakage Monitor FSK-MP-2768 H 0

Line & Reacter " slant System Vent Line FSK-NT-879 H 0

PDT Root Valve FSK-MP-933 El 12 PDT Root Valve FSK-MP-1053 HI 7

Primary Loop Drains Steam Gen. #11 FSK-MP-597 H2 12 Reactor Coole _t System Drains FSK-NT-910 H 6

Sample Connection Off Surge Line &

FSK-MP-1021 El 6

Primary Loop PAGE 1 OF 2 802 205

SKETCH NO.

REVISION Hn.E FSK-12-1023 Hi 5

Sample Connection Off Primary Loop FSK-12-1006 El 7

CC-9 and HC-2 Primary Loop Drains &

Cold Leg Loop (Steam Gen. #12B)

FSK-MP-879 0

PDT Root Valve FSK-MP-1312 H3 17 Differential Pressure Indicator on Reactor Coolant Pump #11A, llB,12A,

& 12B PAGE 2 0F 2 802

_?. 0 6

9 UNIT #2 CIASS I PIPING 2" AND UNDER

~'

-~

Sketch No.

Rev. No.

Title FSK-MP-3100 ED 11 Safety Injection Tank 21A FSK-MP-3102 HA 12 Safety Injection Tank 21B FSK-MP-3101 HA 15 Safety Injection Tank 21B FSK-MP-3096 E 12 Safety Injection & Containment Spray FSK-MP-3099 HB 7

Safety Injection Tank 22B FSK-MP-3103 HA 13 Safety Injection Tank 22B FSK-MP-3142 HC 15 Regenerative EX Inlet Loop 22A FSK-MP-3140 HC 2

Primary Loop Drains - Stm. Gen. 22 FSK-MP-3137 HB 4

Pressurizer Safety & Relief Valve FSK-MP-3193 HB 2

Pressurizer Spray FSK-MP-3141 HB 7

Primary Loop Drains - Stm. Gen. 21 FSK-MP-3148 HD 2

Reactor Coolant Drains FSK-MP-3120 HA 5

PDT Root Valves, Stm. Gen. 21 and 22 FSK-MP-3191 HA 5

Sample Connection Off Surge Line FSK-MP-3195 HB 1

Instrument Connection, Pressurizer #21 FSK-MP-3194 HF 8

Primary Loop Drains, Stm. Gen. f22 FSK-MP-3189 HB 2

Primary Loop Drains, Stm. Gen. #21 FSK-MP-3199 HA 0

Differential Press. Ind. Pump 21A FSK-MP-3200 HA 0

Differential Press. Ind. Nmp 21A, 213, 22A, 223 FSK-MP-3192 HA 1

PDT Root Valves, Stm. Gen. #21 FSK-MP-3190 HA 1

PDT Root Valves, Stm. Gen. #22 FSK-MP-?201 HA 0

Differential Press. Ind. Pumps 21A, 21B, 22A, 22B FSK-MP-3202 HB 0

Differential Press. Ind. Pumps 21A, 21B, 22A, 22B FSK-MP-3113 HA 7

Safety Injection Tank #223 802 207

ENCmEERING DATA Rr,yu1KED TO PERFORM ANSI B31.1 STRESS CALCUI.ATION 1.

Design and operating temperatures and pressuras for all modes of operation.

2.

Detailed piping is[2 metric indicating the geometry of the piping system with all necessary dimension including bend radii and weld locations.

3.

List of a-in=1 pipe sizes, schedules, weights, irisulation weights, and material.

4.

Locations and types of pipe supports (rigid, snubbers, springs) direction of action and clearences.

5.

Valve locations, lengths, weights.

6.

Anchor novements (seismic & thermal).

7.

Nozzle load allowables.

8.

Seismic response spectra.

9.

Descriptions of any special fitting or coc:ponents.

e

.w-832 208

e

_ 0 IE Bulletin 79-lh Inspection lu.ements a) Pine Run Geometrv:

Segnent length and direction.

b) Suurorts and Restraints: Location, design configuration, orientation (restriction or load-carrying direction), clearances.

c) Embedments: Installed per design drawings.

d) Pine Attachments:

Correct location of miscellaneous attachments.

e) Valves and Ouerators :

Identification, location, configuration, operator orientation, veights.

802 209