Forwards IE Bulletin 79-05C & 79-06C, Nuclear Incident at TMI - Suppl. Action Required
ML19249B620
Person / Time
Site: Sequoyah  
Issue date: 08/17/1979
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Parris H
TENNESSEE VALLEY AUTHORITY
References
NUDOCS 7909040604
Download: ML19249B620 (2)


Text

i i

sam arco i

'o UNITED STATES 8'

' 7, NUCLEAR REGULATORY COMMISSION 5

A'-( ' i REGION 11 o,

.,I 101 M A RIETT A ST., N.W., SUIT E 3100

% ' b' [

ATLANT A, GEORGI A 30303 7

AUG i 1979 50-327/

50-328 Tennessee Valley Authority ATTN:

H.

G. Parris Manager of Power 500A Chestnut Street Tower II Chattanooga, Tennessee 37401 Gentlemen:

The enclosed Bulletin 79-05C and 79-06C is forwarded to you for action. Written responses are required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, t

Y

. _ __ ; 4 v

(ig James P. O'Reilly Director

Enclosure:

1. IE Bulletin Nos.79-05C and 79-06C
2. Listing of IE Bulletins Issued In 1.ast Twelve Months

,,,,_s,-

r,

\\ $ 0 1 f ed m J

  • 7 909040 bb i

Tennessee Valley Authority.

cc w/ enc 1:

G. G. Stack, Project Manager Post Office Box 2000 Daisy, Tennessee 37319 J. M. Ballentine Plant Superintendent Post Office Box 2000 Daisy, Tennessee 37319 J. F. Cox 400 Commerce Street W10C131 C Knoxville, Tennessee 37902 D. L. Lambert, Project Engineer 400 Chestnut Street Tower II Chattanooga, Tennessee 37401 r, G < '..; q u

s+

.t..-

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 July 26, 1979 IE Bulletin Nos.79-05C & 79-06C NUCLEAR INCIDENT AT THREE MILE ISLAND - SUPPLEMENT Description of Circumstances:

Information has become available to the NRC, subsequent to the issuance of IE Bulle* ins 79-05,79-05A, 79-05B, 79-06,79-06A, 79-06A (Revison 1) and 79-06B, which requires modification to the " Action To Be Taken By Licensees" portion of IE Bulletins79-05A, 79-06A and 79-06B, for all pressurized water reactors (PWRs).

Item 4.c of Bulletin 79-05A required all holders of operating licenses for Babcock 6 Wilcox designed PWRs to revise their operating procedures to specify that, in the event of high pressure injection (HP1) initiation with reactor coolant pumps (RCPs) operating, at least one RCP per loop would remain operating.

Similar requirements, applicable to reactors designed by other PWR vendors, were contained in Item 7.c of Bulletin 79-06A (for Westinghouse designed plants) and in Item 6.c of Bulletin 79-06B (for Combustion Engineering designed plants).

Prior to the incident at Three Mile Island Unit 2 (TMI 2), Westinghouse and its licensees generally adopted the position that the operator should promptly trip all c erating RCPs in the loss of coolant accident (LOCA) situation. This Westinghouse position, has led to a series of meetings between the NRC staff and Westinghouse, as well as with other PWR vendors, to discuss this issue.

In addition, more detailed analyses concerning this matter were requested by the NRC.

Recent preliminary calculations perfcrmed by Babcock & Wilcox, Westing-house and Combustion Engineering indicate that, for a certain spectrum of small breaks in the reactor coolant system, continued operation of the RCPs can increase the mass lost through the break and prolong or aggravate the uncover-ing of the reactor core.

The damage to the reactor core at TMI 2 followed tripping of the last operating RCP, when two phase fluid was being pumped through the reactor coolant system.

It is our current understanding that all three of the nuclear steam system suppliers for PWRs now agree that an acceptable action under LOCA symptoms is to trip all operating RCPs immediately, before significant voiding in the reactor coolant system occurs.

Action To Be Taken By Licensees:

In order to alleviate the concern over delayed tripping of the RCPs after a LOCA, all holders of operating licenses for PWR facilities shall take the following actions:

Y?,~. ?

4 IE Bulletin Nos.79-05C & 79-06C July 26, 1979 Page 2 of 3 Short-Term Actions 1.

In the interim, until the design change required by the long-term action of this Bulletin has been incorporated, institute the following e:tions at your facilities:

A.

Upon reacter trip and initiation of HPI caused by low reactor coolant system pressure, immediately trip all operating RCPs.

B.

Provide two licensed operators in the control room at all times during operation to accomplish this action and other immediate and followup actions required during such an occurence. For facilities with dual control rooms, a total of three licensed operators in the dual control room at all times meets the require-ments of this Bulletin, 2.

Perform and submit a report of LOCA analyses for your plants for a range of snall break sizes and a range of time lapses between reactor trip and pump trip.

For each pair of values of the parameters, deter-mine the peak cladding temperature (PCT) which results.

The range of values for each parameter must be wide enough to assure that the maximum PCT or, if appropriate, the region containing PCTs greater than 2200 degrees F is identified.

3.

Based on the analyses done under Item 2 above, develop new guidelines for operator action, for both LOCA and non-LOCA transients, that take into account the impact of RCP trip requirements.

For Babcock &

Wilcox designed reactors, such guidelines should include appropriate requirements to fill the steam generators to a higher level, following RCP trip, to promote natural circulation flow.

4.

Revise emergency procedures and train all licensed reactor operators and senior reactor operators based on the guidlines developed under Item 3 above.

5.

Provide analyses and develop guidelines and procedures related to in-adequate core cooling (as discussed in Section 2.1.9 of NUREG-0578, "TMI 2 Lessons Learned Task Force Status Report and Short-Term Recom-mendations") and define the conditions under which a restart of the RCPs should be attempted.

Long-Term Action 1.

Propose and submit a design which will assure automatic tripping of the operating RCPs under all circumstances in which this action may be needed.

%'G',A,N

k IE Bulletin Nos.79-05C & 79-06C July 26, 1979 Page 3 of 3 Schedule The schedule for the short-term actions cf this Bulletin is:

Item 1: Effective upon receipt of this Bulletin, Item 2: Within 30 days of receipt of this Bulletin, Item 3: Within 30 days of receipt of this Bulletin, Item 4: Within 45 days of receipt of this Bulletin, Item 5: October 31, 1979 (as noted in Table B-2 of NUREG-0578, under Item 3).

A schedule for the long-term action required by this Bulletin should be developed and submitted within 30 days of receipt of this Bulletin.

Reports should be submitted to the Director of the appropriate NRC Regional Office with copies forwarded to the Director, Office of Inspection and Enforcement and the Director, Office of Nuclear Reactor Regulation, Washington, D. C. 20535.

Approved by GAO (R0072): clearance expires 7/31/80. Approval was given under a blanket clearance specifically for generic problems.

col unn c, -, a ;

E i M.

  • ~4***

Enclosure IE Bulletin Nos.79-05C & 79-06C Page 1 of 3 July 26, 1979 LISTING OF IE BULLETINS ISSUED IN LAST TWELVE MONTliS Bulletin Subj ec t Date Issued Issued To No.

79-17 Pipe Cracks in Stagnant 7/26/79 All PWR's with Borated Water Systems at operating license PWR Plants 79-16 Vital Area Access ~'ntrols 7/26/79 All Holders of and applicants for Power Reactor Operating Licenses who anticipate loading fuel prior to 1981 79-15 Deep Draft Pump 7/11/79 All Power Reactor Licensees with a CP Deficiencies and/or OL 79-14 Seismic Analyses for 6/2/79 All Power Reactor As-Built Safety-Related facilities with an OL or a CP Piping System OL for action. All System Piping BWRs with a CP for in f o rma t ion.

79-02 Pipe Support Base Plate 6/21/79 All Power Reactor Faci 11tica with an (Rev. 1)

Designs Using Concrete OL or a CP Expansion Anchor Bolts 79-12 Short Period Scrams at 5/31/79 All GE BWR Facilities BWR Facilities with an OL 79-11 Faulty Overcurrent Trip 5/22/79 All Power Reactor Device in Circuit Breakers Facilities with an OL or a CP for Engineered Safety Systems 79-10 Requalification Training 5/11/79 All Power Reactor Facilities with an OL Program Statistics 79-09 Failures of GE Type AK-2 4/17/79 All Power Reactor Circuit Breaker in Safety Facilities with an OL or CP Related Systems 79-08 Events Relevant to BWR 4/14/79 All BWR Power Reactor Reactors Identified During Facilities with an OL Three Mile Island Incident

<.;> ~

. ; t. o..s

IE Bulletin Nos.79-05C & 79-06C Enclosure July 26, 1979 Page 2 of 3 LISTING OF IE BULLETINS ISSUED IN LAST TWELVE MONTHS Bulletin Subj e ct Date Issued Issued To No.

79-07 Seismic Stress Analycis 4/14/79 All Power Reactor of Safety-Related Piping Facilities with an OL or CP 79-06B Review of Operational 4/14/79 All Combustion Engineer-Errors and System Mis-ing Designed Pressurized alignments Identified Water Power Reactor During the Three Mile Facilities with an Island Incident Operating License 79-06A Review of Operational 4/18/79 All Pressurized Water (Rev 1)

Errors and System Mis-Power Reactor Facilities alignments Identified of Westinghouse Design During the Three Mile with an OL Island Incident 79-06A Review of Operational 4/14/79 All Pressurized Water Errors and System Mis-Power Reactor Facilities alignments Identified of Westinghouse Design.

During the Three Mile with an OL Island Incident 79-06 Review of Operational 4/11/79 All Pressurized Water Errors and System Mis-Power Reactors with an alignments Identified OL except B&W facilities During the Three Mile Island Incident 79-05A Nuclear Incident at 4/5/79 All B&W Power Reactor Three Mile Island Facilities with an OL 79-05 Nuclear Incident at 4/2/79 All Power Reactor Three Mile Island Facilities with an OL and CP

--a wi' -t.b!

55

IE Bulletin Nos.79-05C & 79-06C Enclosure July 26, 1979 Page 3 of 3 LISTING OF IE BULLETINS ISSUED IN LAST IWELVE MONTHS Bulletin Subj ec t Date Issued Issued To No.

79-04 Incorrect Weights for 3/30/79 All Power Reactor Swing Check Valves Facilities with an Manufactured by Velan OL or CP Engineering Corporation 78-12B Atypical Weld Material 3/19/79 All Power Reactor in Reactor Pressure Facilities with an Vessel Welds OL or CP 79-03 Longitudinal Welds Defects 3/12/79 All Power Reactor In ASME SA-312 Type 304 Facilities with an Stainless Steel Pipe Spools OL or CP Manufactured by Youngstown Welding and Engineering Co.

79-02 Pipe Support Base Plate 3/2/79 All Power Reactor Designs Using Concrete Facilities with an Expansion Anchor Bolts OL or CP 79-01A Environmental Qualification 6/6/79 All Power Reactor of Class IE Equipment Facilities with an (Deficiencies in the Envi-OL or CP ronmental Qualification of ASCO Solenoid Valves) 79- 01 Environmental Qualification 2/8/79 All Power Reactor of Class IE Equipment Facilities with an OL or CP

?