ML19246A639

From kanterella
Jump to navigation Jump to search
Forwards IE Circular 79-10, Pipefittings Mfg from Unacceptable Matl. No Action Required
ML19246A639
Person / Time
Site: Oyster Creek
Issue date: 06/26/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Finfrock I
JERSEY CENTRAL POWER & LIGHT CO.
References
NUDOCS 7907060187
Download: ML19246A639 (1)


Text

..

g, UM TED STAT Ls 7.UCLE AR R EGUL ATC C Ol l \\ll b/.I U ?"

3 nEctor, t

,s, 17;,7 cira,:x w m.

K la.G O F P R U%I A Pt ?'

' L VD el A 11403 June 26, 1979 Docket No. 50-219 Jersey Central Power and Light Company ATTN:

Mr. Ivan R. Finfrock, Jr.

Vice President Madison Avenue at Punch Bowl Road Morristown, New Jersey 07960 Gentlemen:

The enclosed IE Circular 79-10 is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities.

No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Bulletin will be issued to recommend or request, specific licensee actions.

If you have questions regarding this matter, please contact this office.

Sincerely,

~ m. R Ua ~

ce H. Grier 1 rector

Enclosures:

1.

IE Circular No. 79-10 2.

List of IE Circulars Issued in Last Twelve Months cc w/encls:

J. T. Carroll, Station Superintendent A. Z. Roisman, Matural Resources Defense Council 298 0Ae 790706O/87 9

ENCLOSURE 1 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Circular No. 79-10 Date:

June 26, 1979 Page 1 of 2 PIPEFITTINGS MANUFACTURED FROM UNACCEPTABLE MATERIAL Description of Circumstances:

miberty Equipmvit and Supply Company of Kennewick, Washington and Tube Turns Division, Chemetron Corporation of Louisville, Kentucky reported on April 4 and 12, 1979, respectively, that potentially defective pipe fittings were manufactured from material with a high carbon content beyond the range allowed by ASTM A-234 WPB.

These high carbon content fittings may crack when welded.

Tube Turns received 3.500 OD x.250W pipe from U. S. Steel - Lorain -

identified as U. S. Steel Heat No. N570028.

A total of 28,153 feet was received and identified by Tube Turns as Lot W6719.

U. S. Steel has not been able to determine the exact number of lengths of pipe of incorrect chemistry, but indicated it could be at least four lengths.

From this pipe, 4" - 90 degrees and 45 degrees

.237 wall elbows and 2"

.237 wall straight tees, ASTM A-234 WPB, were produced by Tube Turns.

Each length of pipe is twenty feet and makes from 20 to 30 fittings.

Approximately 27,000 fittings were produced and each is identified by Tube Turns Lot No. W6719.

Shipment of these fittings started in March of 1978, and it is estimated all were shipped before the end of 1978.

On May 10, 1979, the Tube Turns Division reported to the NRC that 4" elbows, Lot W6719, have been provided to the nuclear power plants listed below.

U.S.

Steel has tested about one hundred and fifty (150) loose and installed fittings at the seven sites noted by an asterisk.

  • Grand Gulf
  • Zimmer
  • Phipps Bend
  • Waterford III
  • Brown's Ferry Midland Limerick Shoreham
  • LaSalle Sequoyah
  • Brunswick Hartsvilla Bellefonte On June 1, 1979, the Tube Turns Division reported to the NRC via telephone that of the 160 fittings tested at Nuclear Power Plants, three (3) g es h{

were found to have a high carbea content and were replaced.

A11 construction permit holders are advisn[ M e "e y ;;yiew nf their pipefitting receiving documents for the p and determine if fittings manufactured by p DUPLICATE DOCUMENT identified as Tube Turn Lot W6719-If sh i

were received, appropriate corrective act

' ' Entire document previously entered J

1 into system under:

l MD3010 I'll nNo No. of pages:

W ar w w we 3