K pa arcg
,0, UNITED STATES
+
S,' 3.,, cf NUCLEAR REGULATORY COMMISSION
- g 7 A,;(, iC W ASHING TON. D. C. 20555
- kM.(/
June 6,1979 v
Docket No. 50-219 Mr. I. R. FinTrock, Jr.
Vice President - Generation Jersey Central Power & Light Company Madison Avenue at Punch Bowl Road Morristown, New Jersey 07960
Dear Mr. Cinfrock:
RE:
RE0t!EST FOR ADDITIONAL INFORMATION TOPIC VI-l OYSTER CREEK NUCLEAR GENERATING STATION To continue our review of Systematic Eva'uation Program Topic VI-1, " Organic Materials and Post Accident Chemistry", we request that you submit the infor-mation described in the enclosure.
Your response is requested within 30 days of receipt of tnis letter so that we can maintain our review schedule.
Sincerely, jm Mm Dennis L. Ziemanri, Chief Operating Reactors Branch *2 Division of Operating Reactors
Enclosure:
Request for Additional Information cc w/ enclosure:
See next page a
es h
7907370@
462 253 p
Mr. I. R. Finfrock, Jr. June 6, 1979 cc w/ enclosure:
G. F. Trowbridge, Esquire Shaw, Pittman, Potts and Trowbridge 1800 M Street, N. W.
Washington, D. C.
20036 GPU Service Corporation ATTN:
Mr. E. G. Wallace Licensing Manager 260 Cherry Hill Road Parsippany, New Jersey 07054 Anthony Z. Roisman Natural Resources Defense Council 917 15th Street, N. W.
Washington, O. C.
20005 Steven P. Russo, Esquire 248 Washington Street P. O. Box 1060 Toms River, New Jersey 08753 Joseph W. Ferraro, Jr., Esquire Deputy Attorney General State of New Jersey Department of Law and Public Safety 1100 Raymond Bculevard Newark, New Jersey 07012 Ocean County Library Brick Township Branch 401 Chambers Bridge Road Brick Town, New Jersey 08723 K M C, Inc.
ATTN:
Richard E. Schaffstall 1747 Pennsylvania Avenue, N. W.
Suite 1050 Washington, D. C.
20006 462 254
REQUEST FOR ADDITIONAL INFORMATION INFORMATION NEEDED TO EVALUATE TOPIC VI-1, "0RGANIC MATERIALS AND POST ACCIDENT CHEMISTRY" The following infortnation is necessary to complete our evaluation of this topic:
l.
Estimate the areas and thicknesses of the major protective coating systems inside containment, including aluminum and zine base paints, epoxy paints, acrylic hcquer, etc.
2.
Indicate whether these coating systems and their methods of application were qualified according to the recocciendations of Regu.latory Guide 1.54.
3.
If not, describe the QA provisions which were used to assure proper application.
4.
For coatings not qualified with Regulatory Guide 1.54, describe the present condition of the coatings, including estimates of the amounts of flaking, peeling, cracking, bubbles, etc.
5.
Estimate the quantity of other miscellaneous coating materials (such as on snubbers) not qualified according to Regulatory Guide 1.54.
6.
Estimate the types and amounts of other organic materials such as electrical insulation inside containment.
7.
In addition to the information described abcve for organic coating systems, we will need the following information with respect to the related copic VI-5, " Combustible Gas Control":
Estima:.e the surface area and thickness of aluminum, zinc and galvanized steel inside containment.
We have reviewed u.m 'r.fc=t. ion available in the docket files for some of the SEP plants and found that the information described above was not available.
Since this topir is a fairly recent addition to the review areas #or CP's and OL's, we do not expect to 'ind the information in any of the SEP plant docket material.
Accordingly, you are requested to provide the information described above.
4h2