UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August 28, 2019 Mr. Richard W. Boyle, Chief Sciences Branch Division of Engineering and Research Office of Hazardous Materials Safety U.S. Department of Transportation 1200 New Jersey Ave., S.E.

Washington, D.C. 20590

SUBJECT:

APPLICATION FOR THE MODEL NO. TN-MTR TRANSPORT PACKAGE -

FIRST REQUEST FOR ADDITIONAL INFORMATION

Dear Mr. Boyle:

By letter dated March 5, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19115A127), as supplemented on June 12, 2019 (ADAMS Accession No. ML19169A036), the United States Department of Transportation requested that the U.S. Nuclear Regulatory Commission (NRC) staff perform a review of the French Certificate of Approval F/357/B(U)-96 Revision Eah, for the Model No. TN-MTR transport package and make a recommendation concerning the revalidation of the package for import and export use.

Specifically, you requested that the NRC only review the content in Appendix 9 to the French certificate for shipment of the Gisete 4, Gisete 5, or Gisete 8 radioisotopic thermal generators.

In connection with our review, we need the information identified in the enclosure to this letter.

To assist us in scheduling the staffs review of your response, we request that you provide this information one month from the date of issuance of this request. Inform us at your earliest convenience, but no later than three weeks after issuance of this request, if you are not able to provide the information by that timeframe. If you are unable to provide a response one month after issuance of this request, our review may be delayed.

The staff is available for a public meeting if you wish to discuss these issues in more detail prior to deciding on your course of action. Please reference Docket No. 71-3052 and EPID L-2019-LLA-0044 in future correspondence related to this action.

If you have any questions regarding these matters, please contact me at (301) 415-6577.

Sincerely,

/RA/

Bernard White, Senior Project Manager Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-3052 EPID L-2019-LLA-0044

Enclosure:

Request for Additional Information

ML19239A196 OFFICE:

DSFM DSFM DSFM DSFM NAME:

BWhite SFigueroa Via email JBorowsky Via email VWilson Via email DATE:

8/21/19 8/22/19 8/22/19 8/21/19 OFFICE:

DSFM DSFM DSFM NAME:

YDiaz-Sanabria Via email TTate JMcKirgan DATE:

8/28/19 8/23/19 08/28/19

Enclosure Request for Additional Information U.S. Department of Transportation French Certificate of Approval F/357/B(U)-96 Revision Eah Docket No. 71-3052 Model No. TN-MTR Package By letter dated March 5, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19115A127), as supplemented on June 12, 2019 (ADAMS Accession No. ML19169A036), the U.S. Department of Transportation requested that the U.S.

Nuclear Regulatory Commission (NRC) staff performs a review of the French Certificate of Approval F/357/B(U)-96 Revision Eah, for the Model No. TN-MTR transport package and make a recommendation concerning the revalidation of the package for import and export use.

Specifically, you requested that the U.S. Nuclear Regulatory Commission only review the content in Appendix 9 to the French certificate for shipment of the Gisete 4, Gisete 5, or Gisete 8 radioisotopic thermal generators.

This request for additional information identifies information needed by the NRC staff (the staff) in connection with its review of the application. The staff used the International Atomic Energy Agency Specific Safety Requirements No. 6, Regulations for the Safe Transport of Radioactive Material," 2012 Edition, in its review of the application.

Thermal Evaluation Provide the temperature of the outer surface to confirm that temperatures are below the allowable 85°C for exclusive use shipment.

Chapter 1 (page 18/34) states that surface temperatures are greater than 50°C and that the package is transported as exclusive use. However, it appears there was no demonstration in the thermal chapters, including Chapter 2 (Document No. DOS-18-011415-024 Rev. 1.0), that outer surface temperatures were below the allowable temperature for exclusive use shipment.

This information is needed in order to determine compliance with if the TN-MTR package meets the requirements of paragraphs 654 and 655 of SSR-6, 2012 Edition.

Shielding Evaluation Provide the flux-to-dose rate conversion factors (DCFs) used within TRIPOLI 4.4 to calculate external radiation levels.

The DCFs should be appropriate for the calculating dose equivalent for meeting the SSR-6 requirements and that are measurable since verification at the time of shipment is (often) done by measurements.

The staff needs this information to verify that the shielding is adequate for determining compliance with paragraphs 526, 527, 648(b), and 659(b)(i) of SSR-6, 2012 Edition.