Forwards IE Insp Repts 50-269/79-09,50-270/79-09 & 50-287 /79-09 on 790409-13&notice of Violation. Notice of Violation Withheld (Ref 10CFR2.790)
ML19225D042
Person / Time
Site: Oconee  
Issue date: 05/25/1979
From: Kenna W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Parker W
DUKE POWER CO.
Shared Package
ML19225D033 List:
References
NUDOCS 7908030626
Download: ML19225D042 (2)


See also: IR 05000269/1979009

Text

DirRi?.t TP"T"'TD r"'NITH

CONU,uS 2.7;3 tI"....AT10N

.

-

o na

,

'o

UNITED STATES

+8'

" ,7,

NUCLEAR REGULATORY COMMISSION

.,

$4

E

REGION 11

'

og

[

101 MARIETT A ST., N.W., SUITE 310o

AT LANT A, G EORGI A 30303

j*

.....

MAY 251979

In Reply Refer To:

RII:JMF

50-269/79-9

50-270/79-9

50-287/79-9

g

.f;i

0:}g.

l

'g

Duke Power Company

)

1

]~

ATTN:

W. O. Parker, Jr.

2

Vice President, Steam Productior

P. O. Box 33189

Charlotte, N C 28242

Gentlemen:

This refers to the inspection conducted by J. M. Fuchko of this office on

April 9-13, 1979, of activities authorized by NRC Operating License Nos. DPR-38,

DPR-47 and DPR-55 at Oconee 1, 2 and 3 and to the discussion of our findings

held with J. H. Davis at the conclusion of the inspection.

The area examined during this inspection was your physical protection program

under the 2pplicable provisions of Title 10, Code of Federal Regulations,

Part 73, " Physical Protection of Plants and Materials." Within this area,

the inspection consisted of selective examinations of procedures and

representative records, interviews with personnel, and observations by the

inspectors.

We have examined actions you have taken with regard to previously identified

enforcement matters. These are discussed in the enclosed inspection report.

During the inspection, it was fcund that certain activities under your

These items

license appear to be in noncompliance with NRC requirements.

and references to pertinent requirements are listed in the Notice of Violation

enclosed herewith as Appendix A.

This notice is sent to you pursuant to the

provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10,

Code of Federal Regulations. Section 2.201 requires you to submit to this

office, within 20 days of your receipt of this notice, a written statement or

explanation in reply including:

(1) corrective steps which have been taken by

you and the results achieved; (2) corrective steps which will be taken to avoid

further noncompliance; and (3) the date when full compliance will be achieved.

Details of activities involving safeguards and security measures are exempt

from disclosure in accordance with 10 CFR 2.790(d). Therefore, your response

should be incorporated in a separate paper and referenced in your reply.

79 0803 06k

i13

wws 2n .... .. ?

mt Ter"n:.U.?

'

QTERB.L TR!.?.SM'TTED HEREWITH

'

.

CONTAINS 2.7S312iC. .AT10M

T

.

Duke Power Company

-2-

MAY 251979

'

In accordance with Section 2.790(d) of the NRC's " Rules of Practice," Part 2,

Title 10, Code of Federal Regulations, activities involving safeguards and

security measures are exempt from public disclosure; therefore, the enclosures

to this letter with the exception of the report cover page, which is an

inspection sunxnary, will not be placed in the Public Document Room.

Should you have any questions concerning this letter, we will be glad to

discuss them with you.

Sin erely,

W

'

(

Kenna, Chief

'

.

.

SafeguardsfBranch

Enclosures:

1.

Appendix A, Notice of Violation

(Exempt from Disclosure)

2.

Inspection Report Nos. 50-269/79-9,

50-270/79-9 and 50-287/79-9

(Exempt from Disclosure)

3.

Inspection Sunnary

(Not Exempt)

,

cc w/encls:

J. E. Smith, Station Manager

P. O. Box 1175

Seneca, S C 29678

h

..

uTmunn~moe m

CONT Anis 2.701.iii,0.'.'.All3 N