ML19225C350

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-15, Deep Draft Pump Deficiencies. Action Required
ML19225C350
Person / Time
Site: Pilgrim
Issue date: 07/11/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Andognini G
BOSTON EDISON CO.
References
NUDOCS 7907270316
Download: ML19225C350 (1)


Text

  • {pa arc.')o,,

o Y*

~

UNITED STATES

,3 '^

NUCLEAR REGULATORY COMMISSION c

o

$ O ' '"

REGION I 0, '

g 631 PARK AVENUE KING oF PRUSSIA, PE*'NSYLVANIA 19406 July 11, 1979 Docket No. 50-293 Boston Edison Company M/C Nuclear ATTN:

Mr. G. Carl Andognini, Manager Nuclear Operations Department 800 Boylston Street Boston, Massachesetts 02199 Gentlemen:

The enclosed Bulletin No. 79-15 is forwarded to you for action.

A written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, h[

/

+

h cyce H. Grier 7 irector

Enclosures:

1.

IE Bulletin No. 79-15 w/ Attachments 2.

Listing of IE Bulletins Issued in Last Twelve Months cc w/encls:

P. J. McGuire, Pilgrim Statior, rianager A. Z. Roisman, Natural Resources Defense Council k "2 7 03g 7 9 0727 0 3.,b l

ENCLOSURE 1 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Bulletin No. 79-15 Date:

July 11, 1979 Page 1 of 3 DEEP DRAFT PUMP DEFICIENCIES Description of Circumstances:

On October 20, 1978, Commonwealth Edison Company reported that manufacturing deficiencies had been identified in new high pressure core spray, low pressure core spray, and residual heat removal pumps manufactured by Ingersoll-Rand (I-R)

Company, Cameron Pump Division.

Each of these pumps is a vertical turbine pump with impellers located in bowls in a sump or a self contained barrel.

The motor (prime mover) is located at the highest pump elevation to take into account maximum flooding at the site or space considerations.

The suction is at the lower end of the pump while the discharge head is just below the driver.

Bearings supporting the vertical shaft segments (usually 5 to 10 segments) are either self lubri ated, force fed (lubricated by fluid being pumpedt or oil lubricated and maintained within their own isolated system.

These pump are desigaated as " Deep Draft".

Figures 1&2 show typical outlines of such pumps.

The internal deficiencies, identified through dimensional and visual inspections were as follows:

Low Pressure Core Spray Pumps (I-R Model No. 29APKD-5) (Date of Manufacture -

Feburary 1973)

Loose impeller bolts and bolts improperly staked Loose key - keyway fit Excessive runout on pump shaft Bearing showed wear Rearing clearance exceeded recoc.m.Jad tolerance Coupling thread galled Wear ring clearance out-of-specification Impeller-to shaft clearance out of specification Cracks found in second-and-third-stage impellers Stuffing box bushings were severely galled

(' ~ ~

High Pressure Core Spray Pumps (I-R Modi

~

September 1972)

DUPLICATE DOCUMENT i

Bearing clearance exceeded recommend

' Entire document previously entered Wear ring clearance out-of-specifica into system under:

Bearings showed wear ANO 3 ( 2/ h (;/A j 427 m No. of pages:

h p

m--

= - 1 %

n.____ _

_, n

_