l 7 ', S -:

ft

/.-

0 C

.I. - 0;.

13 Date 5-18-79

[

l

]

MEMORANDUM FOR: Dar-all G. Eisenhut, Deputy Director, Division of 6.f Operating Reactors THRU:

Steven A. Varga, Chief, Light Water Reactors Branch No. 4, Division of Project Management FROM:

F. J. Williams, Jr., Technical Coordinator, Division of Project Management

SUBJECT:

PROBLEMS - TMI BULLETIN RESPONSES Bulletin 79-05B

, Plant All B&W i

l Source Bulletin response, I&E Corments (Oconee)

~

Resolution required for safety evaluation Yes s

Problem -

Item 4f calls for manual trip on low pressurizer level.

Attached information indicates the confusion on this requirement. Need to know whether 4f should be deieted and whether a high pressurizer level should be added.

l

? ~*

i 6

Assessment by Problea Group - None I

t 1,..,

L.

Additional infomation available - Attaciisc (same argument proposed by 2 other licensees).

e i

N y

f ffI cc:

E. Case R. Tedesco

/. J. William g r.

[R.Mattson S. Varga

0. D1ss M. Williams S. Hanauer P

255 92 F'I*

E 2

--g.

m y= g. _ _.,,, w

  • ' * * ~
  • - ~ - - -

7 906 276 ) Ah'

./ </

huLLFr:0 3-OSB Twa 4 4

Provide procedures and training to operating personnel for a promot manual trip of the reactor for transients that result in a pressure increase in the reactor. coolant system.

These transients include:

a.

loss of main feedwater b.

turbine trip c

Main Steam Isolation Val 2 closure d.

Loss of offsite power e.

Low OT3G level f.

low pressurizer level.

.j_

Occ ee e.

Resc-mos e.

RESPONSE

Station Lirective 3.1.30, " Required Manual Trips of the Reactor," has been approved and distributed which requites the Control Room operator to =anually trip the reactor pro =ptly when transients that result in a pressure increase in the Reacter Coolant System occur. These specific transients are:

1.

Turbine Trip (At reactor power levels greater than 200 F?)

2.

Main Steam Stop Valve Closure (Two valves on same OTSO or all four valves) 3.

Loss of Offsite Power 4

Low OTSG Level Station Directive 3.1.21, Loss of bbin Feedwater, previously required a canual trip of the reactor upon loss of both main feedwater pumps or upon loss of feed-water flow to the steam generators.

This Directive rc=ains in effect.

The required manual trip of the. reactor on low pressurizer level is consider -

inconsistent with the general concern expressed in this ttes of pressure increases in the reactor coolant system.

Low pressuriser level is associated with under-pressurization resulting f rom overcooling rather than overpressurization.

A

  • eactor trip or. low pressuri er level would compound the transient as the priaacy heet soucce is removed.

Therefore, rather than adding a mandatory manual reactor trip, station procedures have been revised to require a prompt increase in reactor coolant make-up flow on decreasing pressuriner level in order to restore normal level.

l The above h ue been discussed and reviewed by all licensed personnel, r

o r '-

.')k 8