ML19210E548

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-26, Boron Loss from BWR Control Blades. No Response Required
ML19210E548
Person / Time
Site: Beaver Valley
Issue date: 11/20/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Dunn C
DUQUESNE LIGHT CO.
References
NUDOCS 7912050228
Download: ML19210E548 (1)


Text

as arog

-7s' e

,(y e ( (Io,,

UNITED STATES g

NUCLEAR REGULATORY COMMISSION 2

g.-i"/.-

2 REGION l o, ; [

[

631 PARK AVENUE

%'D O

o KING OF PRUSSIA, PENNSYLVANIA 19406 Docket No. 50-334 NOV 2 01373 Duquesne Light Company ATTN:

Mr. C. N. Dunn Vice President Operations Division 435 Sixth Avenue Pittsburgh, Pennsylvania 15219 Gentlemen:

The enclosed IE Bulletin 79-26 is forwarded to you for information. No written response is required. If you desire additional information regarding this matter, please contact this office.

Sincerely, w

Royce H. Grier h irector

Enclosures:

1.

IE Bulletin No. 79-26 2.

List of Recently Issued IE Bulletins CONTACT:

D. L. Caphton (215-337-5266) cc w/encls:

F. Bissert, Technical Assistant Nuclear R. Washabaugh, QA Manager J. Werling, Station Superintendent G. Moore, General Superintendent, Power Stations Department J. J. Carey, Nuclear Technical Assistant R. Martin, Nuclear Engineer 1500 120 M[

7912050

ENCLOSURE 1 UNITED STATES SSINS:

6820 NUCLEAR REGULATORY COMMISSION Accession No.:

OFFICE OF INSPECTION AND ENFORCEMENT 7910250475 WASHINGTON, D.C.

20555 IE Bulletin No. 79-26 Date: November 20, 1979 Page 1 of 4 BORON LOSS FROM BWR CONTROL BLADES Description of Circumstances:

The General Electric Company (GE) has informed us of a failure mode for control blades which can cause a loss of boron poison material.

Hot cell examinations of both foreign and doirestic blades have revealed cracks near the upper end of stainless steel tubing and loss of boron from the tubes.

The cracks and boron loss have so far been g nfined to locations in the poison tubes with more than 50 percent Boron-10 (B

) local depletion.

Observed crack sizes range from a quarter to a half inch in length and from one to two mils in width.

GE has postulated that the cracking is due to stress corrosion induced by solidification of boron carbide (B C) particles and swelling of the compacted 3

B C as helium and lithium concentrdtions grow.

Once primary coolant penetrates g

the cladding (i.e., the cracking has progressed through the cladding wall and thehelium-lithiumpressuresaresufficienttoopenthecrack),gronis leached out of the tube at locations with more than 50 percent B local depletion (local depletion is considered to be twice the average depletion).

Itwasfurtherfoundwithsimilarcrackingbutwithlessthan50percentlocal depletion of B

, that leaching did not occur even though primary coolant had penetrated the cladding.

The cracking and boron loss shorten the design life of the control blade.

According to the GE criteria the end of design life is reached when the reactivity wg th of *.he blade is reduced by 10 percent, which corresponds to 42 percent B

de6etionaveragedoverthetopquarterofthecontrolglade.

Because of the 1 aching mechanism, GE has reduced the allowance for B depletion averaged over t.he top quarter of the control blade from the 42 percent value to 34 percent.

Tne safety significance of boron loss is its impact on shutdown capability and scram reactivity.

Although shutdown ca bili

~

margin tests after refueling, the calcu tests are based on the assumption that in scram reactivity due to boron loss c DUPLICATE DOCUMENT Power Ratio (CPR) reductions during the the consequences of control rod drop ac Entire document previously entered into system under: