ML19209C261

From kanterella
Jump to navigation Jump to search
Discusses Containment Margins in Ice Condenser Plants.Peak Pressures in Proposed Plant Are Double Capability of Containment Design.Knowledgeable Groups Should Review Problem
ML19209C261
Person / Time
Site: Mcguire, McGuire, Atlantic Nuclear Power Plant  Duke Energy icon.png
Issue date: 06/04/1979
From: Kelber C
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Levine S
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
Shared Package
ML19209C260 List:
References
NUDOCS 7910120300
Download: ML19209C261 (1)


Text

"

f Ei!CLOSilRE 1

. # ;p* *Ecoq'o UNITED STATES

~

E 'y,. v f h NUCLEAR REGULATORY COMMISSION

  • C WASmNGT ON, D. C. 20555
.g \\q,&b 5

% !s[ v

'%,.s /

JUN 4 1973 MEMORAfiDUM FOR:

Saul Levine, Director Of fice of fiuclear Regulatory Research

~

TilRU:

Thomas E. Murley, Director fEA Division of Reactor Safety Research FROM:

Charles fi. Kelber, Assistant Director for Advanced heactor Safety Research Division of Reactor Safety Research

SUBJECT:

C0fiTAlf4MEllT MARGINS Iti ICE-C0f1DEtiSER PLAfiTS In the process of reviewing material submitted in support of the Offshore Power Sys tems Floa ting fluclear Flant (Core Debris Retention Sys tem),

members of nly s ta f f noted that:

1.

The proposed plant features an ice-condenser system; 2.

The containment design basis is 15 psig; 3.

111e peak pressures observed in TMI-2 containment were about twice this.

My staff are not experts in LWR containment analysis and so they feel knowledgeable groups in RSR or other Divisions should review this problem.

0 i 'k Charles N. Kelber, Assis tant Di rector for Advanced Reactor Safety Re earch Division of Reactor Safety Research h

cc: H. Denton hbE

'b i