ML19208B641

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-354/79-03 & 50-355/79-03 on 790416-19 & Notice of Violation
ML19208B641
Person / Time
Site: Hope Creek  
Issue date: 06/21/1979
From: Robert Carlson
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Martin T
Public Service Enterprise Group
Shared Package
ML19208B632 List:
References
NUDOCS 7909210123
Download: ML19208B641 (2)


See also: IR 05000354/1979003

Text

l. . . A

pn Rio

UNITED STATES

'o,'o

NUCLEAR REGULATORY COMMisslON

p

$

REGION l

C

631 PARK AVENUE

f

KING OF PRUSSI A. PENNSYLV ANIA 19406

\\..../

+

h nim

Docket Nos. 50-354

50-355

Public Service Electric & Gas Company

ATTN:

Mr. T. J. Martin

Vice President

Engineering and Construction

80 Park Place

Newark, New Jersey 07101

Gentlemen:

Subject:

Combined Inspection 50-354/79-03; 50-355/79-03

This refers to the inspection conducted by Mr. L. Narrow of this office on April

16-14, 1979, at Hope Creek Generating Station, Unit 1 and 2 Site in Hancocks

Bridge, New Jersey of activities authorized by NRC License Nos. CPPR-120 and

CPPR-121 and to the discussions of our findings held by Mr. Narrow with Mr.

Giardino and other members of your staff at the conclusion of the inspection.

Areas examined during this inspection are described in the Office of Inspection

and Enforcement Inspection Report which is enclosed with this letter.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observations by the

inspector.

Based on the results of this inspection, it appears that one of your activities

was not conducted in full compliance with NRC requirements, as set forth in the

Notice of Violation, enclosed herewith as Appendix A.

This item of noncompli-

ance has been categorized into the levels as described in our correspondence to

you dated December 31, 1974.

This notice is sent to you pursuant to the pro-

visions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10,

Code of Federal Regulations.

Section 2.201 requires you to submit to this

office, within thirty (30) days of your receipt of this r.otice, a written state-

ment or explanation in reply including:

(1) corrective steps which have been

taken by you and the results achieved; (2) corrective steps which will be taken

to avoid further items of noncompliance; and (3) the date when full compliance

will be achieved.

384331

7 909210 /M 3

.

.

.

Public Service Electric & Gas Company

2

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title

10, Code of Federal Regulations, a copy of this letter and the enclosures will

be placed in the NRC's Public Document Room.

If this report contains any information

that you (or your contractor) believe to be proprietary, it is necessary that

you make a written application within 20 days to this office to withhold such

information from public disclosure. Any such application must be accompanied by

an affidavit executed by the owner of the information, which identifies the

document or part sought to be withheld, and which contains a statement of reasons

which addresses with specificity the items which will be considered by the

Comission as listed in subparagraph (b)(4) of Section 2.790. The information

sought to be withheld shall be incorporated as far as possible into a separate

part of the affidavit.

If we do not hear from you in this regard within the

specified period, the report will be placed in the Public Document Room.

Should you have any questions concerr,ing this inspection, we will be pleased to

discuss them with you.

Sincerely,

C

Robert T. Carlson, Chief

Reactor Construction and Engineering

Support Branch

Enclosures:

1.

Appendix A, Notice of Violation

2.

Office of Inspection and Enforcement Combined Inspection Report

Number 50-354/79- 03; 50-355/79-03

cc w/encls:

E. N. Schwalje, Manager - Quality Assurance,

Engineering and Construction Department

30*It032

.