Carolina Power & tight Compar.y August 30, 1979 FILE: NG-3516 (B)

SERIAL:

GD-79-2164 Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission Region II, Suite 3100 101 Marietta Street Atlanta, GA 30303 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-324 LICENSE NO. DPR-62 LICENSEE EVENT REPORT 2-79-066

Dear Mr. O'Reilly:

In accordance with Section 6.9.1.9.c of the Technical Specificatiens for Brunswick Steam Electric Plant, Unit 2,

the attached Licensee Event Report is submitted. This report fulfills the requirement for a written report within thirty (30) days of a reportable occurrence and is in accordance with the format set forth in NUREG-0161, July, 1977.

Yours very truly, bsu d '

J. Furr Manager Generation Department SBT: men

  • Attachment cc:

Mr. R. A. Ila rtfield Mr. V.

Stello C.1 f'(*Af1:~ud sy A G.

E. 'c. ; -...,

  • ua 411 Fayettevtile Etreet
  • P_ O Box 1551 + Rafe+gh. N C. 27602