MONTHYEARML20010D3712020-01-10010 January 2020 Updated NRC Staff Exhibit List ML19304B3532019-10-31031 October 2019 INT049-R - Supplemental Testimony of Victor E. Saouma, Ph.D Regarding Petrographic Documents ML19262F1292019-09-19019 September 2019 NER005-R2 - NextEra Exhibit List ML19266A6342019-09-0404 September 2019 INT030-R - Rebuttal Testimony of Victor E. Saouma, Ph.D Regarding Scientific Evaluation of Nextera'S Aging Management Program for Alkali-Silica Reaction at the Seabrook Nuclear Power Plant (Revised) IR 05000443/20140052019-07-24024 July 2019 NRC030 - Letter from Glenn T. Dentel, NRC, to Dean Curtland, NextEra, Seabrook Station, Unit No. 1 - NRC Integrated Inspection Report 05000443/2014005, (Feb. 6, 2015) IR 05000443/20150022019-07-24024 July 2019 NRC031 - Letter from Glenn T. Dentel, NRC, to Dean Curtland, NextEra, Seabrook Station, Unit No. 1 - NRC Integrated Inspection Report 05000443/2015002, (Aug. 5, 2015) IR 05000443/20150042019-07-24024 July 2019 NRC032 - Letter from Fred L. Bower, III, NRC, to Dean Curtland, NextEra, Seabrook Station, Unit No. 1 - NRC Integrated Inspection Report 05000443/2015004 and Independent Spent Fuel Storage Installation Report No. 07200063/2015001 (Feb. 12, IR 05000443/20140032019-07-24024 July 2019 NRC029 - Letter from Glenn T. Dentel, NRC, to Dean Curtland, NextEra, Seabrook Station, Unit No. 1 - NRC Integrated Inspection Report 05000443/2014003, (Aug. 5, 2014) IR 05000443/20140022019-07-24024 July 2019 NRC028 - Letter from Glenn T. Dentel, NRC, to Kevin Walsh, NextEra, Seabrook Station, Unit No. 1 - NRC Integrated Inspection Report 05000443/2014002, (May 6, 2014) IR 05000443/20110102019-07-24024 July 2019 NRC024 - Letter from Christopher G. Miller, NRC, to Paul Freeman, NextEra, Seabrook - NRC Inspection Report 05000443/2011010 Related to Alkali-Silica Reaction Issue in Safety Related Structures (Mar. 26, 2012) IR 05000443/20130052019-07-24024 July 2019 NRC027 - Letter from Glenn T. Dentel, NRC, to Kevin Walsh, NextEra, Seabrook Station, Unit No. 1 - NRC Integrated Inspection Report 05000443/2013005, (Jan. 30, 2014) IR 05000443/20110022019-07-24024 July 2019 NRC021 - Letter from Arthur L. Burritt, NRC, to Paul Freeman, NextEra, Seabrook Station, Unit 1 - NRC Integrated Inspection Report 05000443/2011002 (May 12, 2011) IR 05000443/20110032019-07-24024 July 2019 NRC023 - Letter from Arthur L. Burritt, NRC, to Paul Freeman, NextEra, Seabrook Station, Unit No. 1 - NRC Integrated Inspection Report 05000443/2011003 (Aug. 12, 2011) IR 05000443/20170022019-07-24024 July 2019 NRC036 - Letter from Fred L. Bower, III, NRC, to Mano Nazar, NextEra, Seabrook Station, Unit No. 1 - Integrated Inspection Report 05000443/2017002, Encl. at 31-32 (Aug. 14, 2017) IR 05000443/20160042019-07-24024 July 2019 NRC035 - Letter from Fred L. Bower, III, NRC, to Eric Mccartney, NextEra, Seabrook Station, Unit No. 1 - Integrated Inspection Report 05000443/2016004, (Feb. 8, 2017) IR 05000443/20160022019-07-24024 July 2019 NRC034 - Letter from to Eric Mccartney, NextEra, Seabrook Station, Unit No. 1 - Integrated Inspection Report 05000443/2016002, (Aug. 5, 2016) IR 05000443/20120102019-07-24024 July 2019 NRC026 - Letter from Raymond K. Lorson, NRC, to Kevin Walsh, Seabrook Station, Unit No. 1 - Confirmatory Action Letter Follow-up Inspection - NRC Inspection Report 05000443/2012010, at 1 (Aug. 9, 2013) IR 05000443/20130062019-07-24024 July 2019 NRC086 - Letter from Darrell J. Roberts, NRC, to Kevin Walsh, NextEra, Mid-cycle Performance Review and Inspection Plan Seabrook Station, Unit 1 (Report 05000443/2013006), (Sept. 3, 2013) Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) IR 05000443/20170042019-07-24024 July 2019 NRC037 - Letter from Fred L. Bower, III, NRC, to Mano Nazar, NextEra, Seabrook Station, Unit No. 1 - Integrated Inspection Report 05000443/2017004, Encl. at 24-27 (Feb. 12, 2018) IR 05000443/20180012019-07-24024 July 2019 NRC038 - Letter from Fred L. Bower, III, NRC, to Mano Nazar, NextEra, Seabrook Station, Unit No. 1 - Integrated Inspection Report 05000443/2018001, Encl. at 8-9 (May 14, 2018) IR 05000443/20180112019-07-24024 July 2019 NRC039 - Letter from Mel Gray, III, NRC, to Mano Nazar, NextEra, Seabrook Station, Unit No. 1 - Integrated Inspection Report 05000443/2018011, (Aug. 10, 2018) IR 05000443/20180032019-07-24024 July 2019 NRC040 - Letter from Fred L. Bower, NRC, to Mano Nazar, NextEra, Seabrook Station, Unit No. 1 - Integrated Inspection Report 05000443/2018003, (Nov. 13, 2018) ML19206A0392019-07-24024 July 2019 NRC070 - Research Activities Fy 2018-2020, NUREG-1925, Rev. 4 (Mar. 2018) ML19205A5232019-07-24024 July 2019 NER011 - Edward Carley Resume ML19205A5222019-07-24024 July 2019 NER010 - Dr. Oguzhan Bayrak Curriculum Vitae ML19205A5212019-07-24024 July 2019 NER009 - Chris Bagley Curriculum Vitae ML19205A5202019-07-24024 July 2019 NER008 - John Simons Curriculum Vitae ML19205A5192019-07-24024 July 2019 NER006 - Michael Collins Biography ML19205A5182019-07-24024 July 2019 NER048 - L. Phan, Structural Performance of NPP Concrete Structures Affected by Alkali-Silica Reaction (Asr), Slides for NRC Regulatory Information Conference Session TH27 (2018) ML19205A5172019-07-24024 July 2019 NER047 - N. Ezell Et Al., Experimental Collaboration for Thick Concrete Structures with Alkali-Silica Reaction (2018) ML19205A5162019-07-24024 July 2019 NER046 - Seabrook Mechanical Maintenance Procedure MS0517.51, Installation of Geokon Snap-Ring Borehole Extensometers, Rev. 0 (Feb. 2016) (Cover & Pages 13-19) ML19205A5152019-07-24024 July 2019 NER044 - Seabrook Station Unit 1, Updated Final Safety Analysis Report (UFSAR) (Rev. 19) (2.5.2.5 Only) ML19205A5142019-07-24024 July 2019 NER043 - NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition Chapter 3 - Design of Structures and Components, Equipment, and Systems 3.7.2, Rev. 4 (Sept. 2013) ML19205A5122019-07-24024 July 2019 NER005 - NextEra Exhibit List ML19205A5082019-07-24024 July 2019 NER038 - Gocevski, V., Pathologies/Degradation Mechanisms Experienced by Hydro-Quebec During the Evaluation of Gentilly-2 NPP, Report Submitted to Ascet, (June 2015) ML19205A5052019-07-24024 July 2019 NER035 - U.S. Department of Commerce, National Bureau of Standards, Nbs Special Publication 577, Development of a Probability Based Load Criterion for American National Standard A58 (1980) ML19205A5032019-07-24024 July 2019 NER033 - Matthew Sherman Curriculum Vitae ML19205A5022019-07-24024 July 2019 NER032 - Glenn Bell Curriculum Vitae ML19205A5002019-07-24024 July 2019 NER031 - Said Bolourchi Curriculum Vitae ML19205A4972019-07-24024 July 2019 NER028 - Sg&H Report 110594-RPT-02, Rev. 1, Damage Rating Index and ASR Rating (Feb. 10, 2012) (FP100702) ML19205A4962019-07-24024 July 2019 NER027 - Saouma, V., Benchmark Problems for Aar Fea Code Validation (Aug. 4, 2017) ML19205A4952019-07-24024 July 2019 NER018 - MPR-3727, Rev. 1, Seabrook Station: Impact of Alkali-Silica Reaction on Concrete Structures and Attachments (Jan. 2014) and NextEra Supplements I-V Thereto (FP100716, Rev. 4) ML19205A4922019-07-24024 July 2019 NER014 - NUREG-2191, Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report, Vol. 2 (July 2017) (Cover and Section X.M1) ML19205A4912019-07-24024 July 2019 NER013 - U.S. Department of Transportation, Federal Highway Administration, Report on the Diagnosis, Prognosis, and Mitigation of Alkali-Silica Reaction (ASR) in Transportation Structures (FHWA-HIF-09-004) (Jan. 2010) ML19205A4902019-07-24024 July 2019 NER002 - MPR Testimony - Attachment 1 - Glossary ML19205A4872019-07-24024 July 2019 NRC Staff Appendix a Exhibit List ML19205A4512019-07-24024 July 2019 NRC085 - Letter from William M. Dean, NRC, Kevin Walsh, NextEra, Closure of Confirmatory Action Letter 1-12-002, Seabrook Station, Unit 1 (Oct. 9, 2013) ML19205A4502019-07-24024 July 2019 NRC084 - Letter from Darrell J. Roberts, NRC, to Kevin Walsh, NextEra, Deviation from the Reactor Oversight Process Action Matrix for Seabrook Station, Unit No. 1, (Sept. 12, 2012) ML19205A4492019-07-24024 July 2019 NRC083 - Memorandum from William M. Dean, NRC, to R.W. Borchardt, NRC, Request for Deviation from the Reactor Oversight Process Action Matrix to Provide Increased Oversight of the Alkali-Silica Reaction Issue at Seabrook, (Sept. 5, 2012) 2020-01-10
[Table view] |
Text
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD In the Matter of Docket No. 50-443-LA-2 NEXTERA ENERGY SEABROOK, LLC ASLBP No. 17-953-02-LA-BD01 (Seabrook Station, Unit 1)
Hearing Exhibit Exhibit Number: NER005 Exhibit
Title:
NextEra Exhibit List
NextEra Energy Seabrook, LLC, Docket No. 50-443-LA-2 September 2019 Evidentiary Hearing Exhibits NextEra Witness/ Exhibit Title/Description ADAMS Exh. No. Panel Accession No.
NER001 MPR/NextEra Testimony of NextEra Witnesses Michael Collins, John Simons, Christopher Bagley, Oguzhan Bayrak, and Edward Carley (MPR Testimony)
NER002 MPR/NextEra MPR Testimony - Attachment 1 -
Glossary NER003 MPR/NextEra MPR Testimony - Attachment 2 -
Proprietary Appendix
[PROPRIETARY]
NER004 MPR/NextEra Testimony of NextEra Witnesses Said Bolourchi, Glenn Bell, and Matthew Sherman (SGH Testimony)
NER005 MPR/NextEra; NextEra Exhibit List SGH NER006 MPR/NextEra Michael Collins Biography NER007 MPR/NextEra Seabrook Structures Monitoring Program Manual, Rev. 7
[PROPRIETARY]
NER008 MPR/NextEra John Simons Curriculum Vitae NER009 MPR/NextEra Chris Bagley Curriculum Vitae 1
NextEra Witness/ Exhibit Title/Description ADAMS Exh. No. Panel Accession No.
NER010 MPR/NextEra Dr. Oguzhan Bayrak Curriculum Vitae NER011 MPR/NextEra Edward Carley Resume NER012 MPR/NextEra; The Institution of Structural SGH Engineers, Structural Effects of
[Copyright] Alkali-Silica Reaction (July 1992)
NER013 MPR/NextEra; U.S. Department of Transportation, SGH Federal Highway Administration, Report on the Diagnosis, Prognosis, and Mitigation of Alkali-Silica Reaction (ASR) in Transportation Structures (FHWA-HIF-09-004) (Jan. 2010)
NER014 MPR/NextEra NUREG-2191, Generic Aging ML17187A204 Lessons Learned for Subsequent License Renewal (GALL-SLR)
Report, Vol. 2 (July 2017) [Cover and Section X.M1]
NER015 MPR/NextEra MPR-3848, Rev. 0 Seabrook Station, Approach for Shear and
[PROPRIETARY] Reinforcement Anchorage Testing of Concrete Affected by Alkali-Silica Reaction (Apr. 2013)
(FP100818)
NER016 MPR/NextEra Allford, M., Expansion Behavior of Reinforced Concrete Elements Due
[Copyright] to Alkali-Silica Reaction (Aug.
2016) 2
NextEra Witness/ Exhibit Title/Description ADAMS Exh. No. Panel Accession No.
NER017 MPR/NextEra EPRI Report 3002013192, Evaluation of Laboratory Tests to
[Copyright] Detect Up-to-Date Expansion and Remaining Expansion in Concrete Structures Affected by Alkali-Silica Reaction (Oct. 15, 2018)
NER018 MPR/NextEra MPR-3727, Rev. 1, Seabrook Station:
Impact of Alkali-Silica Reaction on Concrete Structures and Attachments (Jan. 2014) and NextEra Supplements I-V Thereto (FP100716, Rev. 4)
NER019 MPR/NextEra Bayrak, O., Structural Implications of ASR; State of the Art (Feb. 2,
[PROPRIETARY] 2012) (FP100697)
NER020 MPR/NextEra MPR 0326-0062-88, Rev. 2, Initial Expansion Assessment of ASR-
[PROPRIETARY] Affected Reinforced Concrete Structures at Seabrook Station (Mar. 2018) (FP101070, Rev. 1)
NER021 MPR/NextEra MPR-4231, Rev. 0, Instrumentation for Measuring Expansion in
[PROPRIETARY] Concrete Affected by Alkali-Silica Reaction (Oct. 2015) (FP100972)
NER022 MPR/NextEra MPR-4262, Shear and Reinforcement Anchorage Testing
[PROPRIETARY] of Concrete Affected by Alkali-Silica Reaction, Vol. I, Rev. 1 (July 2016) & Vol. II, Rev. 0 (Jan. 2016)
(FP100994) [Main Report & Apps. E
& G]
3
NextEra Witness/ Exhibit Title/Description ADAMS Exh. No. Panel Accession No.
NER023 MPR/NextEra MPR-3722, Rev. 2, Strength Testing of Anchors in Concrete
[PROPRIETARY] Affected by Alkali-Silica Reaction (Jan. 2016) (FP100718, Rev. 1) [Main Report & App. A]
NER024 MPR/NextEra MPR-4247, Rev. 0 Commercial Grade Dedication Report for
[PROPRIETARY] Seabrook ASR Anchor Testing (Block Series and Girder Series Phase 2) (Dec. 2015) (FP100986)
[Main Report & Apps. A & B]
NER025 MPR/NextEra MPR-4259, Commercial Grade Dedication Report of Seabrook ASR
[PROPRIETARY] Shear, Reinforcement Anchorage and Instrumentation Testing (Jan.
2016) [Main Report, App. B, &
Pages D-1745, D-2615 to 16, F-9474, G-14, and G-18 to 19]
NER026 MPR/NextEra MPR-3757, Rev. 4, Shear and Reinforcement Anchorage Test
[PROPRIETARY] Specimen Technical Evaluation (May 2014) (FP100760)
NER027 MPR/NextEra Saouma, V., Benchmark Problems for AAR FEA Code Validation (Aug. 4, 2017)
NER028 MPR/NextEra; SG&H Report 110594-RPT-02, Rev.
SGH 1, Damage Rating Index and ASR Rating (Feb. 10, 2012) (FP100702) 4
NextEra Witness/ Exhibit Title/Description ADAMS Exh. No. Panel Accession No.
NER029 MPR/NextEra EPRI Report 3002013190, Modeling Concrete Structures
[Copyright] Affected by Alkali Silica Reaction:
Hydro-Quebec Approach for Hydraulic and Nuclear Power Plants (Oct. 15, 2018)
NER030 MPR/NextEra Giannini, E., Evaluation of Concrete Structures Affected by
[Copyright] Alkali-Silica Reaction and Delayed Ettringite Formation (2012)
NER031 SGH Said Bolourchi Curriculum Vitae NER032 SGH Glenn Bell Curriculum Vitae NER033 SGH Matthew Sherman Curriculum Vitae NER034 SGH ASCE Standard ASCE/SEI 7-16, Minimum Design Loads and
[Copyright] Associated Criteria for Buildings and Other Structures (2016) [Cover
& Page 1]
NER035 SGH U.S. Department of Commerce, National Bureau of Standards, NBS Special Publication 577, Development of a Probability Based Load Criterion for American National Standard A58 (1980) 5
NextEra Witness/ Exhibit Title/Description ADAMS Exh. No. Panel Accession No.
NER036 SGH ASCE Standard ASCE/SEI 4-16, Seismic Analysis of Safety-Related
[Copyright] Nuclear Structures (2016) [Cover &
Pages 9-11, 23]
NER037 MPR/NextEra; Esposito, R., and Hendriks, M.A.N.,
SGH Literature Review of Modelling
[Copyright] Approaches for ASR in Concrete: A New Perspective, EUROPEAN JOURNAL OF ENVTL. & CIVIL ENGG (2017)
NER038 SGH Gocevski, V.,
Pathologies/Degradation Mechanisms Experienced by Hydro-Quebec During the Evaluation of Gentilly-2 NPP, Report Submitted to ASCET, (June 2015)
NER039 SGH Neville, A.M., Properties of Concrete, 5th Edition, Pearson
[Copyright] Education Limited; Harlow, Essex, England, 2012 [Cover Pages &
Pages 426-27, 436-37, 444-45]
NER040 SGH J.J. Brooks, Accuracy of Estimating Long-Term Strains in Concrete, 36
[Copyright] Magazine of Concrete Research 127, 131-45 (June 1984)
NER041 SGH Mijnsbergen, J. and Reinhardt, H.
W., Long-Time Creep and
[Copyright] Expansion Behavior of Concrete in a Marine Environment, 109 American Concrete Institute Special Publication 599-624 (SP 109-27)
(1994) 6
NextEra Witness/ Exhibit Title/Description ADAMS Exh. No. Panel Accession No.
NER042 SGH G.E. Troxell, et al., Long-Time Creep and Shrinkage Tests of Plain
[Copyright] and Reinforced Concrete, 1958 Proceeding of the American Society for Testing and Materials 1101-20 NER043 SGH NUREG-0800, Standard Review Plan ML13198A223 for the Review of Safety Analysis Reports for Nuclear Power Plants:
LWR Edition, Chapter 3 - Design of Structures and Components, Equipment, and Systems § 3.7.2, Rev.
4 (Sept. 2013)
NER044 SGH Seabrook Station Unit 1, Updated Final Safety Analysis Report (UFSAR)
(Rev. 19) [§ 2.5.2.5 only]
NER045 MPR/NextEra MPR-4286, Rev. 0, Supplemental Commercial Grade Dedication
[PROPRIETARY] Report for Seabrook ASR Test Programs (Mar. 2016) (FP101003)
NER046 MPR/NextEra Seabrook Mechanical Maintenance Procedure MS0517.51, Installation of Geokon Snap-Ring Borehole Extensometers, Rev. 0 (Feb. 2016)
[Cover & Pages 13-19]
NER047 MPR/NextEra N. Ezell et al., Experimental Collaboration for Thick Concrete Structures with Alkali-Silica Reaction (2018) 7
NextEra Witness/ Exhibit Title/Description ADAMS Exh. No. Panel Accession No.
NER048 MPR/NextEra L. Phan, Structural Performance of NPP Concrete Structures Affected by Alkali-Silica Reaction (ASR), Slides for NRC Regulatory Information Conference Session TH27 (2018)
DB1/ 105506972.1 8