    • Viii~,.i
      ;;~01..;g[1~;
      ;ifJ>i?6Jp;~..

R(o:ii:i:f:o~.n,;Vi_~~INIA,23261 * *

.. ~-..:

.... ):ti.. _:.

.. <.:~:*. *..

"j el*.,

'*~ *

.,~ '...,

'.. *.*.. :**.,:.e

{.

~

.;*... seriaLNo~ 264_* :

  • Mr.:<Noriail,~c.,.~.l!!os~

1 ley ;'.i*Di~~ci~r.

  • ,:*.* *:*, Officie.:' of*.* Insp~ction.. *a:nd Eu:fc:>rcement.*

. * '_. U. s:.*)Juclear Regulatory* *com;niss:Lori\\

Region:*. II*..:. Stiit:'e: 818*:.;.i/.- i, _:;. _;

_.p:o~M/~AB:daa *_* /.*... * ** * *

  • .Docket.'Nos:~ *s.0~280. * '..,,:.
  • 230 Peachtree Str~et,, Northwest"_*':*-.. :
  • Atlanta, -Georgi.a 30303 '* - :_

~-

.\\.*

.... *. ~-- *.

  • .. - s_o..:.2a1 *
    • .
  • License*. No!!:.- -DPR--~2 *. *:. *

-,DPR;.;37 *

~,;.

_* In' res.pqnsfi(to*: a r~~~-~st* f:fom Yo~i"*:-~ffi~-~-,--_the f~lio~in:g *infcirJ;llation:

., r~la_tive to* s~te: settlem~nt;*at. Surry.;i'o~er* :Station* is pr~aentecl to a'.lose*.. -...

    • . the previoueiy*unre'.sQlve,fitem.Oident:f.fied as '.76;.;iS/1; *site**settlement '*sur*: *

. v.~iil,mc~.*

. ihe *~r:(g{ri~J.,* ~~Ilc.eiri' :~~i;*.. '.:~it~: *-~~ttlem~Jt/~~S-_ p~sld:--~P~Jl' tlie :;~sult~. *. *_.

'*of.surveys.take11* in february;'l971-:and-:Apr:f.LJ972~*-* The!~e-- *surveys w~re later*

.. determined' to' be.* in_ error '.d1i'3-.to. the* -~~spl~c~~ht.of the:' r:ef'erenc~- bench.*.**

  • *mark (vain) *, A **survey: usinii° 'a* more<accura.te *reference was c~i:lducted. in*...

. *. May-1975~- * ::The-results -of*;this:sµ~ey**deterini-0:1ad'..that'settlement* ~a~, not a*.**_,

  • .. prdb:lemi*at :the" Sµrry :site., "A:* s4rvey'. progr~- wa$ e.stab1ished -~v_er -,the'. sub-<

sequent'* two year *period -to*. ~on_itpr s:ite ¢1.eyaticni_s. *,-:,The, re'sults* :_o:f;- -these:.. --

surveys -have. indi~ated* -that': a --*small_ amout;it :of hea_ve.has 'beeI1 exper:Le11ced in-the :Vicinity :of.botl:(cont<'linment. structtiree/:-_:However-*;.:of :importiuice.

'. *ia 'the_ diff~retitialmovetnent: -betweert'... saf~ty related* strticturee.

'Tlie. ~llqw-..

able'*tolera:rice* of ',this movemen:t:'is. o~s::-:1.n* *. -(*~042 ;f"t~) ;<>yet;. as* 1:1hQ~ in '-..,:.

  • Table l,' sin,ce: tlle * :iii~t::tal. sirvey'. in ::'the: p:i-e~ent program, the* '.max:i.lnum dif..:.:. - '*

fereritial mov~ent)haa been apprQx~ate,ly o_-.2 *iti,/(.016 ft.);: well.within>.

  • p_ermissibie liiil:i.~s._: 'Ac1clitiorially ~:*.1nspections."_:of strud:ure* *1tlt.er:f~ces re-:_**..

ve.~led' no*visible *ev;Lde~ce:*_~f. differentiaf diaplacemexits~:.

... .C~eref~r'e~ *.ba~ed upo~;ihe* r~l:~bl~-*-dar~*:e~k~n ~~ 'th~ tNrtr~i11anci~- pro- * -*

. gram a~d--:°th_El,vi.st.ui,Lit?-.~P~Cti_on.,.-lleit)ier d;Lffereritial-heave !Jr-aettlement*are

. :p;robl~s at Surry Power.:'stati,.on. -. llen~e*,* :um:est;>i,red item 76;.;.15/1"_-.should :l)e cl,<>.sed. * *.. __.::..* ;,- -;:.-* :_. * -. ;-

<
--'./; ' -::; <*_-, '.. :. ::-. -:*,,*. i,:*

. :,-, ~' ' \\ ;*...

/*'.

. Encioaures

.**.*. ci:: Mr;.* llobert w, Reid, c~:~ ;/ i < i Operating Reactors Branch.4

~,;'. :.,:*. t

'*-.. --.*:*: very. truiy* yo~r~,.

  • .*~YJ2?:~1ft,';,f *.*

C.

  • 1:1.*: StS.111Ilgs >.

--.:* Vice: Presid,~11t::..Power: Supply*. -

<','.*.'etid*Production Operations.,.

--**,1,.,.*,._,

. '~....

~

TABLE 1 DIFFERENTIAL MOVEMENT (ft.)

Survey 1 Survey 2 Survey 3 Survey 4 Interface 11-10-75

  • 5-20-76 1-10-77 5-26-77 1

.005

.004

.005

.001 2

.006

.001

.004

.003 3

,004

.003

.002

.001 4

.003

.001

.006

.001 5

.005

.002

.010

.001 6

.008

.005

.006

.004 7

.002

.003

.001

.001 8

.002

.009

.013

.005 9

.009

.012

.016

.012 10

.001

.004

.004

.006 11

.001

.001

.001

.001

REACTOR CONTA.IN10-ENT UNIT ONE FUEL BUILDING AUXILIARY BUILDING

. SERVICE BUILDING TURBINE BUILDING INTERFACE LOCATIONS REACTOR CONTAINMENT UNIT TWO N

t

INTERFACE DESIGNATIONS

1.

N/W Corner Auxiliary Building/ S/E Side Unit #1 Cable Vault

2.

S Side Unit #1 Containment/ S/W Corner Unit #1 Aux. Feed Pump Room

3.

N/W Side Unit #1 Containment Spray Pump Room/ S/W Side Unit #1 Safeguards Valve Pit

4.

N/E Corner Unit #1 Safeguards Valve Pit/ W Side Unit #1.Containment

5.

N/E Side Unit #1 Containment/ N/W Corner Fuel Building e

6.

N/E Corner Fuel Building/ N/W Side Unit #2 Containment

7.

S/E Corner Unit #2 Containment/ N/E Corner Unit #2 Containment Spray Pump Room

8.

S/E Corner Unit #2 Aux. Feed Pump Room/ S Side Unit #2 Containment

9.

N Side Service Building/ S Side Unit #2 Containment

10.

S/W.Corner Unit #2 Cable Vault/ N/E Corner Auxiliary Building

11.