Calvert Cliffs Operations Test Comments Sim JPM 1 - No comment.
Sim JPM 2-No comment.
Sim JPM 3 - Singular pump (vs plural) in initiating cue.
In-plant JPM 1 - Specify in IC that the applicant has appropriate keys. Specify in cues for JPM steps 1 and 2 that the amber light is not lit when key switch is turned.
In-plant JPM 2 - No comment.
SRO Admin JPM 1 - Specify that this is for normal (e.g., not refueling) SRO.
SRO Admin JPM 2 - Include in examiner cue the condensate and feedwater sodium levels as well as SG sodium levels.
SRO Admin JPM 3 - Include expectation to take calculations out to 4th decimal point in initiating cue.
SRO Admin JPM 4 - For Job 1 change expected emergency exposure to greater than 25 Rem.
Scenario 1 - Specify times for CTs 1 and 2.