Fire Protection Evaluations for Unique and Unbounded Fire Barrier Configurations - E-1F9910-16-01
ML19092A148
Person / Time
Site: Wolf Creek 
Issue date: 03/11/2019
From:
Wolf Creek
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19092A099 List: ... further results
References
WO 19-0010
Download: ML19092A148 (4)


Text

Form APF-05-003-01, Rev. 2 DESIGN DOCUMENT CHANGE NOTICE ASSIGNED DISCIPLINE:

DESE DOCUMENT NUMBER E-1F9910 OTHER DOCUMENTS AFFECTED BY THIS CHANGE:

E-15000, E-1F9905 OTHER DDCN'S REQUIRED TO IMPLEMENT CHANGE:

NONE REASON FOR CHANGE:

Administrative change to reflect room number and/or room description changes within Access Control Area, Fire Area C-5 and C-6. No physical change to PFSSD cables. No change to Fire Area C-5 and C-6 boundaries. No impact to PFSSD Area Anlaysis.

DigsigOrg 4.5 PREPARED BY:

DATE:

01122119 Verifier Qualification will be to the same requirement as the parent document DigsigVer 4.5 0.5 Kamran Derakhshandegan VERIFIED BY: ~~~

DATE:

1124/2019 DigsigApp 4.5 0.5 APPROVED BY: ~~

DATE:

02/04/2019 DigsigDSR 4.5 0.65 DC RELEASE:

DC7 DATE: 02/04/2 019 DESCRIPTION OF CHANGE:

INITIATING DOC.

TYPE: N/A NO. N/A DCP/CCPNO REV. 013979 REV.

16 SEQ. NO.

01 PAGE 1 OF 4 DigsigCert 1.75 3.49 Administrative change does not require PE Stamping per W~NOC-162 Paragraph s.n RPE Certification For ASME Section Ill design specifications, refer to AP 05-004 for qualification requirements Room number and description changes impacted for Fire Area C-5 and C-6. See DDCN pages 2-4 for markup.

DC7 02/04/2019

Post Fire Safe Shutdown Area Analysis E*1F9919, Rev.13 1.0 GENERAL AREA DESCRIPTION Fire Area C-5 Sheet C 5 3 of C 6 16 Fire area C-5 is located on the 1984 elevation of the Control Building and includes the rooms listed in Table C-5-1.

Table C-5-1 Rooms Located in Fire Area C-5

  • ROOM#

DESCRIPTION 3206

-eo11is810 RCA Egress (Corridor) 3212

\\lltle,..e~*e l!!_eelte~ ~88~1 HP Lounge 3212A Partial Height Electrical Chase 3213

~

1e111e11'e *eils' HP Conference Room (West) 3214 Hall

'">'>It::

t"'L

.n 3216 i;l~liR!!j liillillillll RP Calibration LAB #2 3217 Men's Toilet 3218 P1.Pil. elffi~e,tc1ee Exit Monitor Area 3220 Sign In/Out Area 3221 Vestibule No. 1 3222 H.P. Office 3223 ee11i~8fS Closet 3224 Vestibule No. 2 NAC Area Above Suspended Ceiling 3231 Women's Toilet re area C-5 is rotected with an automatic wet-i e s rinkler s stem above and belo Fi p

p p p

y w the suspended ceiling. In addition, partial automatic fire detection is installed. The fire area is separated from adjacent fire areas by minimum 3-hour fire resistant construction.

2.0 PRIMARY EQUIPMENT USED FOR PFSSD Table C-5-2 lists each system credited for post-fire safe shutdown and provides a discussion regarding the availability of the system to perform its Post Fire Safe Shutdown (PFSSD) function if a severe fire occurs in this area. For a summary of the area analysis results, see Section 8.0 of the Fire Area Analysis Narrative section.

DDCN E-1 F991 0-16-01 page 2 of 4 DDCN E-1F9910-16-01 page 2 of 4

0 0

(") z m

I......,

c.o c.o 0

I......

0)

I 0......

"'0 tu

<0 CD c:..v s_

.,J::..

Post Fire Safe Shutdown Area Analysis c-*~r r~~:rTu,-l":ev;-r, Table C-5-4 PFSSD Cables Located in Fire Area C-5 Cable Function Cable#

Location Primary PFSSD (P) Power Evaluation Equipment (C) Control Section (I) Instrumentation 11EFI11EA 3222, 3224, NAC EFFT0053 I

5.2.3 11EFK01 SB 3224, NAC DPEF01A c

5.2.3 11 EJB01AA NAC DPEJ01A p

5.2.5 11GDG01AC 3212, 3224, NAC DCGD01A c

5.2.3 11GDG01AD 3212, NAC DCGD01A c

5.2.3 11GDI04AA 3224, NAC GDTE0001 I

5.2.3 11GDI04AB 3224, NAC GDTZ0001A I

5.2.3 11GDI04AC 3224, NAC GDTZ0001B I

5.2.3 11GDY01AA 3212, 3224, NAC DCGD01A c

5.2.3 11GDY01AD 3212, NAC DCGD01A c

5.2.3 11NGB10SB 3224, NAC NB00116 p

5.2.3 11NGG01AA NAC XNG01 p

5.2.6 11NGG01AB NAC NG01A p

5.2.6 11NGG01AC NAC NG01A p

5.2.6 11NGG01BA NAC XNG03 p

5.2.6 11 NGG01SA NAC XNG05 p

5.2.3 15NBB03AA J

~~3217, 3218, 3220, 3222, ~

NB01 p

5.2.4 I ~

3217,3218,

~3231, 15NBB03AC'32161 3220, 3222,~

p 5.2.4

~,

15NBB03AE

~.3217,~

3220, 3222, c

NB01 p

5.2.4

-~-

Fire Area C-5 Sheet Ca5*11 of C 5 15 Comments ESW Train A Flow Transmitter Train A ESW Pump Control HIS and Interposing Relays Train A RHR Pump Motor Train A ESW Pump Room Supply Fan Motor Train A ESW Pump Room Supply Fan Motor Train A ESW Pump Room Temperature Train A ESW Pump Room Inlet Damper Train A ESW Pump Room Recirc Damper Train A ESW Pump Room Supply Fan HIS and Interposing Relays Train A ESW Pump Room Supply Fan HIS and Interposing Relays NG05E Feeder Breaker XNG01 Incoming Power Feed from NB0113 NG01A Incoming Power Feed from NG0106 NG01A Incoming Power Feed from NG0106 XNG031ncoming Power Feed from NB0110 XNG051ncoming Power from NB0116 Phase A Power Feed XNB01 to NB01 Phase B Power Feed XNB01 to NB01 Phase C Power Feed XNB01 to NB01 DDCN E-1F9910-16-01 page 3 of 4

Post Fire Safe Shutdown Area Analysis E*1F9919, Reo. 13 1.0 GENERAL AREA DESCRIPTION Fire Area C-6 Sheet 0*6*3 of Cu6=13 Fire area C-6 is located on the 1984 elevation of the Control Building and includes the rooms listed in Table C-6-1.

Table C-6-1 Rooms Located in Fire Area C-6 ROOM#

DESCRIPTION 3201 Stairway C-1 3202 Controlled H.P. Tool & Instrument Storage Room 3203 Hot Janitors Closet 3204 Corridor No. 1 3205 H.P. Area 3205A Partial Height Electrical Chase 3207 E:~:i! 'll'lel'li~eF,ll,~eOi RCA Ingress 3208

~eto.tl'll!ii"J Ree111 RP Calibration Lab #1 3209 Decon Area 3210 Decon Shower 3211 "H.Fl. A~iia HP Conference Room (East)

SAC Area Above Suspended Ceiling Fire area C-6 is protected with an automatic wet-pipe sprinkler system above and below the suspended ceiling. In addition, partial automatic fire detection is installed. The fire area is separated from adjacent fire areas by minimum 3-hour fire resistant construction.

2.0 PRIMARY EQUIPMENT USED FOR PFSSD Table C-6-2 lists each system credited for post-fire safe shutdown and provides a discussion regarding the availability of the system to perform its Post Fire Safe Shutdown (PFSSD) function if a severe fire occurs in this area. For a summary of the area analysis results, see Section 8.0 of the Fire Area Analysis Narrative section.

DDCN E-1 F991 0-16-01 page 4 of 4 DDCN E-1F9910-16-01 page 4 of 4