DCP _NRC_000146 Westinghouse Non-Proprietary Class 3

( Page 1 of 18

@Westinghouse U.S. Nuclear Regulatory Commission Document Control Desk 11555 Rockville Pike Rockville, MD 20852 Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA Direct tel: 412-374-5093 Direct fax: 724-940-8505 e-mail: harperzs@westinghouse.com Your Ref: Docket No.52-006 Our Ref: DCP_NRC_000146 March 26, 2019

Subject:

10 CFR 50.46 Annual Report for the APlOOO Plant Design Pursuant to 10 CPR 50.46, "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors", Westinghouse Electric Company, LLC is submitting this report to document emergency core cooling system (ECCS) evaluation model changes or errors for the 2018 Model Year (i.e., 01/01/2018 - 12/31/2018) that affect the peak cladding temperature (PCT) calculations for the APlOOO plant design.

As described below, three APlOOO analyses of record (AORs) are reported:

APlOOO Design Certification AOR:

On December 30th, 2011, the U.S. Nuclear Regulatory Commission certified an amendment to the Design Certification Rule for the APlOOO plant. As such, APlOOO Design Control Document (DCD) Revision 19 documents the AOR for the APlOOO Design Certification. The limiting transient for the APlOOO Design Certification is the Best Estimate Large Break Loss-of-Coolant Accident (LBLOCA). Westinghouse last provided an annual reporting letter to the NRC in March, 2018 (DCP _ NRC _ 003328) which presented an estimated PCT of 2010°P for the LBLOCA evaluation. There are no new ECCS model changes that impact PCT for the 2018 model year. The estimated PCT for LBLOCA remains at 2010°P and does not exceed the 10 CPR 50.46 (b)(l) acceptance criterion of2200°P.

The summary of the PCT margin allocations and their bases for the APlOOO Design Certification AOR are provided in the Attachment 1.

APlOOO V.C. Summer Units 2 & 3 AOR:

In addition to the AOR for the APlOOO Design Certification, the NRC has approved the APlOOO Core Reference Report (WCAP-17524-P-A), a generic topical which includes an ECCS "reanalysis" in the context of 10 CPR 50.46. The AOR contained in the Core Reference Report (CRR) has also been approved for incorporation into the V.C. Summer Units 2 & 3 licenses via license amendment request (LAR). There are no new ECCS model changes that impact PCT for the 2018 model year. The estimated PCT for LBLOCA remains at 1970°P and does not exceed the 10 CPR 50.46 (b)(l) acceptance criterion of2200°P.

APJOOO is a trademark or registered trademark of Westinghouse Electric Company LLC, its affiliates and/or its subsidiaries in the United States of America and may be registered in other countries throughout the world All rights reserved.

Unauthorized use is strictly prohibited. Other names may be trademarks of their respective owners_

© 2019 Westinghouse Electric Company LLC All Rights Reserved I\\Jf?-D

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 2 of 18 The summary of the PCT margin allocations and their bases for the APlOOO V.C. Summer Units 2 & 3 AOR are provided in the Attachment 2.

APlOOO Vogtle Units 3 & 4 AOR:

In addition to the AOR for the APlOOO Design Certification, the NRC has approved the APlOOO Core Reference Report (WCAP-17524-P-A), a generic topical which includes an ECCS "reanalysis" in the context of 10 CFR 50.46. The AOR contained in the Core Reference Report (CRR) has also been approved for incorporation into the Vogtle Units 3 & 4 licenses via NRC License Amendment 52. Additionally, changes as part of the containment pressure analysis included in LAR-17-043 have been approved for incorporation into the Vogtle Units 3&4 licenses via NRC License Amendments 147 (Unit 3) and 146 (Unit 4). As such, the estimated PCT for LBLOCA is 2024°F and does not exceed the 10 CFR 50.46 (b)(l) acceptance criterion of2200°F.

The summary of the PCT margin allocations and their bases for the AP 1000 Vogtle Units 3 & 4

  • AOR are provided in the Attachment 3.

By copy of this letter, COL Holders and COL Applicants are hereby notified of any changes or errors in the APlOOO standard plant design PCT calculations as required by 10 CFR 50.46(a)(3)(iii). This letter contains site-specific evaluations for V.C. Summer Units 2 & 3 and Vogtle Units 3 & 4.

Questions or requests for additional information related to content and preparation of this information should be directed to Westinghouse. Please send copies of such questions or requests to the respective COL Holders and COL Applicants referencing the amended AP 1000 Design Certification Rule for the APlOOO nuclear power plant. A representative for each COL Holder and COL Applicant is included on the cc: list of this letter.

Very truly yours, Zachary S. Harper Manager, APlOOO Licensing

/ Attachments

1.

10 CFR 50.46 Annual Report for the APlOOO Design Certification AOR, 2018 Model Year

2.

10 CFR 50.46 Annual Report fortheAPIOOO V.C. Summer Units 2 & 3 AOR, 2018 Model Year

3.

10 CFR 50.46 Annual Report for the APlOOO Vogtle Units 3 & 4 AOR, 2018 Model Year Cc:

J. Dixon-Herrity - U.S. NRC A. Zaremba

- Duke/Progress A. Bradford

- U.S. NRC S.Franzone

-FP&L D. Habib

- U.S. NRC R. Orthen

-FP&L J. Bouknight

-SCANA L. Oriani

- Westinghouse A.Aughtman

-SNC D. Weaver

- Westinghouse A. Chamberlain - SNC J. Boyle

- Westinghouse E. Grant

-SNC J. Eisenhauer

- Westinghouse Y. Arafeh

-SNC M. Corletti

- Westinghouse

© 2019 Westinghouse Electric Company LLC All Rights Reserved A. Schoedel

- Westinghouse M. Yuan

- Westinghouse D. McDevitt

- Westinghouse M. Sheaffer

- Westinghouse M. Barca

-. Westinghouse M. Patterson

- Westinghouse

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 3 of 18 10 CFR 50.46 Annual Report for the API 000 Design Certification AOR, 2018 Model Year

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page4 of 18 U02 FUEL PELLET HEAT CAPACITY

Background

A typographical error was discovered in the implementation of the U02 fuel pellet heat capacity as described by Equation C-4 ofWCAP-8301 [I] for fuel rod heat-up calculations within the Appendix K Large Break and Small Break LOCA evaluation models. The erroneous formulation results in an over-prediction of heat capacity that increases with fuel temperature. The corrected formulation results in a maximum decrease in heat capacity on the order of approximately 1.2% for existing analyses of record.

This represents a Non-Discretionary Change in accordance with Section 4.1.2 of WCAP-13451 [2].

Affected Evaluation Model(s) 1985 Westinghouse Advanced Plant Small Break LOCA Evaluation Model with NOTRUMP.

Estimated Effect The small over-prediction in U02 fuel pellet heat capacity has been evaluated to have a negligible effect on existing large and small break LOCA analysis results due to the small magnitude of the change, leading to an estimated PCT impact of 0°F.

References

l. WCAP-8301, "LOCTA-IV Program: Loss-of-Coolant Transient Analysis," June 1974.
2. WCAP-13451, "Westinghouse Methodology for Implementation of 10 CFR 50.46 Reporting,"

October 1992.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 LOCA Peak Cladding Temperature {PCT) Summary Plant Name:

APlOOO Utility Name:

Westinghouse Nuclear Power Plants EM:

ASTRUM (2004)

AOR

Description:

Best Estimate Large Break Summary Sheet Status: DCD ANALYSIS-OF-RECORD PCT {°F) 1837 Reference#

Page 5 of 18 Note#

Delta PCT Reporting ASSESSMENTS*

1.

Evaluation of Pellet Thermal Conductivity Degradation and Peaking Factor Bumdown

2.

Revised Heat Transfer Multiplier Distributions

3.

Error in Burst Strain Application AOR + ASSESSMENTS

( 0AF) 139 11 23 PCT=

Reference#

Note#

2 3

4 2010.0 °F The licensee should determine the reportability of these assessments pursuant to 10 CFR 50.46.

  • The "Reporting Year" refers to the annual reporting year in which this assessment was included.

REFERENCES 1

APP-GW-GL-700, Revision 19, "APlOOO Design Control Document," June 2011.

Year**

2012 2013 2013 2

LTR-LIS-12-288, "Information Regarding the Evaluation of Fuel Pellet Thermal Conductivity Degradation and Peaking Factor Bumdown Including Analysis Input Changes for APlOOO Large Break LOCA Analysis," June 2012.

3 L TR-LIS-13-357, "API 000 Plant 10 CFR 50.46 Report for Revised Heat Transfer Multiplier Distributions," July 2013.

4 LTR-LIS-14-41, "APlOOO Plant 10 CFR. 50.46 Report for the HOTSPOT Burst Strain Error Correction,"

January 2014.

NOTES:

(a) None

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 6 of 18 LOCA Peak Cladding Temperature {PCT) Summary Plant Name:

APlOOO Utility Name:

Westinghouse Nuclear Power Plants EM:

NOTRUMP-AP AOR

Description:

Appendix K Small Break Summary Sheet Status: DCD PCT(°F)

Reference#

Note#

ANALYSIS-OF-RECORD 1370 1

(a)

Delta PCT Reporting ASSESSMENTS*

( 0AF)

Reference#

Note#

Year**

1.

Adiabatic Heat-up Calculation 264 2

(a) 2010 AOR + ASSESSMENTS PCT= 1634.0 °F The licensee should detennine the reportability of these assessments pursuant to 10 CFR 50.46.

  • The "Reporting Year" refers to the annual reporting year in which this assessment was included..

REFERENCES 1

APP-GW-GL-700, Revision 19, "APlOOO Design Control Document," June 2011.

2 L TR-LIS-10-373, "10 CFR 50.46 Report for the Evaluation of APl 000 SBLOCA 10-inch Transient Adiabatic Heat-up Calculation," June 2010.

NOTES:

(a) This is an adiabatic heat-up calculated PCT.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP_NRC_000146 Westinghouse Non-Proprietary Class 3 Page 7 of 18 10 CFR 50.46 Annual Report for the APl 000 V.C. Summer Units 2 & 3 AOR, 2018 Model Year

./

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_O<i0146 Westinghouse Non-Proprietary Class 3 Page 8 of 18 U02 FUEL PELLET HEAT CAPACITY

Background

A typographical error was discovered in the implementation of the U02 fuel pellet heat capacity as described by Equation C-4 ofWCAP-8301 [1] for fuel rod heat-up calculations within the Appendix K Large Break and Small Break LOCA evaluation models. The erroneous formulation results in an over-prediction of heat capacity that increases with fuel temperature. The corrected formulation results in a maximum decrease in heat capacity on the order of approximately 1.2% for existing analyses of record.

This represents a Non-Discretionary Change in accordance with Section 4.1.2 ofWCAP-13451 [2].

Affected Evaluation Model(s) 1985 Westinghouse Advanced Plant Small Break LOCA Evaluation Model with NOTRUMP.

Estimated Effect The small over-prediction in U02 fuel pellet heat capacity has been evaluated to have a negligible effect on existing large and small break LOCA analysis results due to the small magnitude of the change, leading to an estimated PCT impact of 0°F.

References

1. WCAP-8301, "LOCTA-IV Program: Loss-of-Coolant Transient Analysis," June 1974.
2. WCAP-13451, "Westinghouse Methodology for Implementation of 10 CPR 50.46 Reporting,"

October 1992.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_D00146 Westinghouse Non-Proprietary Class 3 LOCA Peak Cladding Temperature {PCT) Summary Plant Name:

Utility Name:

EM:

V. C. Summer Unit 2 and Unit 3 South Carolina Electric & Gas ASTRUM (2004)

AOR

Description:

Best Estimate Large Break Summary Sheet Status: Current ANALYSIS-OF-RECORD ASSESSMENTS*

1.

Revised Heat Transfer Multiplier Distributions

2.

Error in Burst Strain Application AOR + ASSESSMENTS PCT (°F) 1936 Delta PCT

AF) 11 23 Reference#

1 Reference#

2 3

PCT= 1970.0 °F Note#

(a)

Note#

The licensee should determine the reportability of these assessments pursuant to 10 CFR 50.46.

    • The "Reporting Year" refers to the annual reporting year in which this assessment was included.

REFERENCES 1

WCAP-17524-P-A, Revision 1, "APlOOO Core Reference Report," May 2015.

Page 9 of 18 Reporting Year**

2013 2013 2

L TR-LIS-13-357, "APlOOO Plant 10 CFR 50.46 Report for Revised Heat Transfer Multiplier Distributions," July 2013.

3 LTR-LIS-14-41, "APlOOO Plant 10 CFR 50.46 Report for the HOTSPOT Burst Strain Error Correction,"

January 2014.

NOTES:

(a) Value contains 2°F bias for PCT sensitivity to PRHR isolation, per Reference 1 response to CRR-008, Table 2 and Table 15.6.5-8.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 LOCA Peak Cladding Temperature (PCT) Summary Plant Name:

Utility Name:

EM:

AOR

Description:

V. C. Summer Unit 2 and Unit 3 South Carolina Electric & Gas NOTRUMP-AP Appendix K Small Break Summary Sheet Status: Current ANALYSIS-OF-RECORD ASSESSMENTS*

1.

NOTRUMP Bubble Rise/Drift Flux Model Inconsistencies

2.

LAR-114 Evaluation AOR + ASSESSMENTS PCT{°F) 663.5 Delta PCT

( 0AF) 32 13 Reference#

1 Reference#

2 3,4,5 PCT=

708.5 °F Note#

Note#

(a)

The licensee should determine the reportability of these assessments pursuant to 10 CFR 50.46.

    • The "Reporting Year" refers to the annual reporting year in which this assessment was included.

REFERENCES 1

WCAP-17524-P-A, Revision 1, "APlOOO Core Reference Report," May 2015.

Page 10 of 18 Reporting Year**

2014 2017 2

LTR-LIS-15-5, "Updates to the APlOOO Plant SBLOCA 10 CFR 50.46 PCT Rackups," January 2015.

3 LTR-LIS-16-144, "Update to the APlOOO Plant SBLOCA 10 CFR 50.46 PCT Rackups for LAR-114,"

January 2017.

4 LTR-LIS-18-53, "APlOOO Plant 10 CFR 50.46 Annual Notification and Reporting for 2017," March 2018.

5 NND-16-0336 (ML16246A214), "Automatic Depressurization System (ADS) Stage 2, 3 & 4 Valve Flow Area Changes and Clarifications," September 2016. Approved by NRC March 17, 2017 as Amendment 64 (MLl 7039B008/ML17039B058).

NOTES:

(a) The LAR-114 evaluation assesses the impact ofreduced automatic depressurization system (ADS) Stage 2, 3, and 4 flow areas described in design change proposals (DCPs) 5051 and 5054.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 11 of 18 10 CFR 50.46 Annual Report for the APlOOO Vogtle Units 3 & 4 AOR, 2018 Model Year

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 12 of 18 LARGE BREAK LOCA DESIGN CHANGE REBASELINE EVALUATION

Background

Numerous APlOOO plant design changes have occurred since the APlOOO Core Reference Report large break loss-of-coolant accident (LBLOCA) analysis was performed [1]. The design changes impacting the LBLOCA analysis included numerous passive core cooling system (PXS), vessel model, containment pressure, reactor coolant system (RCS), and secondary system changes.

These items represent changes in plant configuration or associated set points, distinguished from an evaluation model change in Section 4 ofWCAP-13451 [2].

Affected Evaluation Model(s) 2004 Westinghouse Realistic Large Break LOCA Evaluation Model Using ASTRUM Estimated Effect An LBLOCA rebaseline evaluation was performed using the latest code versions with model corrections to determine an updated limiting peak cladding temperature (PCT) considering the APlOOO plant design changes up to May 5, 2014. The updated evaluation resulted in a PCT penalty of 54 °F against the APlOOO plant Core Reference Report analysis [1].

References I. WCAP-17524-P-A, Revision 1, "APlOOO Core Reference Report," May 2015.

2. WCAP-13451, "Westinghouse Methodology for Implementation of 10 CFR 50.46 Reporting,"

October 1992.

APIOOO is a trademark or registered trademark of Westinghouse Electric Company LLC, its affiliates and/or its subsidiaries in the United States of America and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited. Other names may be trademarks of their respective owners.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 13 of 18 SMALL BREAK LOCA DESIGN CHANGE REBASELINE ANALYSIS

Background

Numerous APlOOO plant design changes have occurred since the APlOOO Core Reference Report small break loss-of-coolant accident (SBLOCA) analysis was performed [l]. The design changes impacting the SBLOCA analysis included numerous passive core.cooling system (PXS), automatic depressurization system (ADS), reactor coolant system (RCS), containment pressure, and secondary system changes.

These items represent changes in plant configuration or associated set points, distinguished from an evaluation model change in Section 4 ofWCAP-13451 [2].

Affected Evaluation Model(s) 1985 Westinghouse Advanced Plant Small Break LOCA Evaluation Model with NOTRUMP.

Estimated Effect An SBLOCA rebaseline analysis was performed using the latest code versions with model corrections to determine an updated limiting peak cladding temperature (PCT) considering the APlOOO plant design changes up to August 4, 2014. The updated analysis resulted in a PCT penalty of 243.5°F against the APlOOO plant Core Reference Report analysis [l].

References

1. WCAP-17524-P-A, Revision 1, "APlOOO Core Reference Report," May 2015.
2. WCAP-13451, "Westinghouse Methodology for Implementation of 10 CFR 50.46 Reporting,"

October 1992.

APIOOO is a trademark or registered trademark of Westinghouse Electric Company LLC, its affiliates and/or its subsidiaries in the United States of America and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited. Other names may be trademarks of their respective owners.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 14 of 18 APlOOO PLANT LAR-133 EVALUATION

Background

The design changes associated with License Amendment Request (LAR) 133 are changes to automatic depressurization system (ADS) Stages 1, 2, 3, and 4 line resistances and in-containment refueling water storage tank (IRWST) line resistances. These changes impact the APlOOO plant small break loss-of-coolant accident (SBLOCA) analysis. These items represent changes in plant configuration or associated set points, distinguished from an evaluation model change in Section 4 ofWCAP-13451 [1].

Affected Evaluation Model(s) 1985 Westinghouse Advanced Plant Small Break LOCA Evaluation Model with NOTRUMP.

Estimated Effect Updated SBLOCA calculations using the latest limiting SBLOCA transient have been performed to assess the impact of the changes to the ADS Stages 1-4 and IRWST injection line resistances associated with LAR-133. The updated calculations resulted in a 144°F PCT penalty, which is assessed against the APlOOO Core Reference Report analysis [2].

References

1. WCAP-13451, "Westinghouse Methodology for Implementation of 10 CPR 50.46 Reporting,"

October 1992.

2. WCAP-17524-P-A, Revision 1, "APlOOO Core Reference Report," May 2015.

APIOOO is a trademark or registered trademark of Westinghouse Electric Company LLC, its affiliates and/or its subsidiaries in the United States of America and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited. Other names may be trademarks of their respective owners.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

pCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 15 of 18 U02 FUEL PELLET HEAT CAPACITY

Background

A typographical error was discovered in the implementation of the U02 fuel pellet heat capacity as described by Equation C-4 ofWCAP-8301 [1] for fuel rod heat-up calculations within the Appendix K Large Break and Small Break LOCA evaluation models. The erroneous formulation results in an over-prediction of heat capacity that increases with fuel temperature. The corrected formulation results in a maximum decrease in heat capacity on the order of approximately 1.2% for existing analyses of record.

This represents a Non-Discretionary Change in accordance with Section 4.1.2 of WCAP-13451 [2].

Affected Evaluation Model(s) 1985 Westinghouse Advanced Plant Small Break LOCA Evaluation Model with NOTRUMP.

Estimated Effect The small over-prediction in U02 fuel pellet heat capacity has been evaluated to have a negligible effect on existing large and small break LOCA analysis results due to the small magnitude of the change, leading to an estimated PCT impact of 0°F.

References

1. WCAP-8301, "LOCTA-IV Program: Loss-of-Coolant Transient Analysis," June 1974.
2. WCAP-13451, "Westinghouse Methodology for Implementation of 10 CFR 50.46 Reporting,"

October 1992.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 16 of 18 LOCA Peak Cladding Temperature (PCT) Summary Plant Name:

Vogtle Unit 3 and Unit4 Utility Name:

Southern Nuclear Operating Company EM:

ASTRUM (2004)

AOR

Description:

Best Estimate Large Break Summary Sheet Status: Current Reference#

ANALYSIS-OF-RECORD PCT (0F) 1936 Note#

(a)

Delta PCT ASSESSMENTS*

( 0AF)

Reference#

Note#

Reporting Year**

l.

Revised Heat Transfer Multiplier Distributions

2.

Error in Burst Strain Application

3.

Design Change Rebaseline Evaluation 11 2

23 3

54 4,5 (b) 2013 2013 2018 AOR + ASSESSMENTS PCT= 2024.0 °F The licensee should determine the reportability of these assessments pursuant to 10 CFR 50.46.

    • The "Reporting Year" refers to the annual reporting year in which this assessment was included.

REFERENCES 1

WCAP-17524-P-A, Revision 1, "APlOOO Core Reference Report," May 2015.

2 LTR-LIS-13-357, "APlOOO Plant 10 CFR 50.46 Report for Revised Heat Transfer Multiplier Distributions," July 2013.

3 LTR-LIS-14-41, "APlOOO Plant 10 CFR 50.46 Report for the HOTSPOT Burst Strain Error Correction,"

January 2014.

4 LTR-LIS-18-393, "Update to the Vogtle Units 3 & 4 LBLOCA and SBLOCA 10 CFR 50.46 PCT Summary Sheets forLAR-79,"November2018.

5 ND-17-2074 (ML18029A243), "Containment Pressure Analysis (LAR-17-043)," December 2017.

Approved by NRC November 7, 2018 as Amendments 147 (VEGP Unit 3) and 146 (VEGP Unit 4)

(ML18289A742).

NOTES:

(a) Value contains 2°F bias for PCT sensitivity to PRHR isolation, per Reference 1 response to CRR-008, Table 2 and Table 15.6.5-8.

(b) The design change rebaseline evaluation used current code versions and accounts for design changes up to May 5, 2014 and plant model error corrections.

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 17 of 18 LOCA Peak Cladding Temperature {PCT) Summary Plant Name:

Vogtle Unit 3 and Unit 4 Utility Name:

Southern Nuclear Operating Company EM:

NOTRUMP-AP AOR

Description:

Appendix K Small Break Summary Sheet Status: Current Reference#

Note#

ANALYSIS-OF-RECORD PCT(0F) 663.5 Delta PCT ASSESSMENTS*

AF)

Reference#

Note#

Reporting Year**

1.

NOTRUMP Bubble Rise/Drift Flux Model Inconsistencies 32

2.

LAR-114 Evaluation 13

3.

LAR-133 Evaluation 144

4.

Design Change Rebaseline Analysis 243.5 2

3,4,5 6,7 8,9 (a)

(b)

(c) 2014 2016 2018 2018 AOR + ASSESSMENTS PCT=

1096.0 °F The licensee should determine the reportability of these assessments pursuant to 10 CFR 50.46.

    • The "Reporting Year" refers to the annual reporting year in which this assessment was included.

REFERENCES 1

WCAP-17524-P-A, Revision 1, "APlOOO Core Reference Report," May 2015.

2 LTR-LIS-15-5, "Updates to the APlOOO Plant SBLOCA 10 CFR 50.46 PCTRackups," January 2015.

3 LTR-LIS-16-144, "Update to the APlOOO Plant SBLOCA 10 CFR 50.46 PCT Rackups for LAR-114,"

January 2017.

4 LTR-LIS-17-59, "APlOOO Plant 10 CFR 50.46 Annual Notification and Reporting for 2016," March 2017.

5 ND-16-0984 (ML16207A340), "Automatic Depressurization System (ADS) Stage 2, 3 & 4 Valve Flow Area Changes and Clarifications (LAR-16-012)," July 2016. Approved by NRC December 29, 2016 as Amendment 62 (ML16357A640).

6 LTR-LIS-16-429, "Update of the APlOOO Plant SBLOCA 10 CFR 50.46 PCT Rackups for LAR-133,"

January 2017.

7 ND-17-0443 (MLI 7090A209), "PXS/ ADS Line Resistance Changes (LAR-17-009)," March 2017.

Approved by NRC February 28, 2018 as Amendments 111 (VEGP Unit 3) and 110 (VEGP Unit 4)

(MLl8026A566/MLl8026A571).

8 LTR-LIS-18-393, "Update to the Vogtle Units-3 & 4 LBLOCA and SBLOCA 10 CFR 50.46 PCT

© 2019 Westinghouse Electric Company LLC All Rights Reserved

DCP _NRC_000146 Westinghouse Non-Proprietary Class 3 Page 18 of 18 j

Summary Sheets for LAR-79," November 2018.

9 ND-17-207 4 (ML18029A243 ), "Containment Pressure Analysis (LAR-17-04 3 )," December 2017.

Approved by NRC November 7, 2018 as Amendments 147 (VEGP Unit 3) and 146 (VEGP Unit 4)

(ML18289A742).

NOTES:

(a) The LAR-114 evaluation assesses the impact ofreduced automatic depressurization system (ADS) Stage 2, 3, and 4 flow areas described in design change proposals (DCPs) 5051 and 5054.

(b) The LAR-133 evaluation assesses the impact ofupdated ADS Stages 1 - 4 and In-Containment Refueling Water Storage Tank (IRWST) line resistances described in DCPs 4903 and 5138.

( c) The design change rebaseline analysis used current code versions and accounts for design changes up to August 4, 2014 and plant model error corrections.

© 2019 Westinghouse Electric Company LLC All Rights Reserved