March 11, 2020 Mr. Brian H. Whitley, Director Regulatory Affairs Southern Nuclear Operating Company, Inc.

3535 Colonnade Parkway, Bin N-226-EC Birmingham, AL 35243

SUBJECT:

VOGTLE ELECTRIC GENERATING PLANT, UNITS 3 AND 4 ISSUANCE OF AMENDMENTS AND GRANTING OF EXEMPTIONS RE: AUTOMATIC DEPRESSURIZATION SYSTEM (ADS) AND CORE MAKEUP TANK (CMT)

DESIGN PARAMETERS (LAR 19-009) (EPID L-2019-LLA-0213)

Dear Mr. Whitley:

In response to your application dated September 30, 2019, as supplemented by letter dated December 19, 2019, the U.S. Nuclear Regulatory Commission has granted the enclosed Exemptions and issued the enclosed Amendment Nos. 176 and 175 to Combined License (COL) Nos. NPF-91 and NPF-92 for the Vogtle Electric Generating Plant (VEGP) Units 3 and 4, respectively. The amendments consist of departures from the Updated Final Safety Analysis Report (UFSAR) Tier 2 information (which includes the plant-specific Design Control Document (DCD) Tier 2 information), related changes to plant-specific Tier 1 information, with corresponding changes to the associated COL Appendix C information, and related changes to COL Appendix A, Technical Specifications.

The amendments authorize changes to reflect revisions in the design parameters of: a) the maximum stroke times for the automatic depressurization system (ADS) Stages 1, 2, and 3 valves; b) the minimum effective flow areas for the ADS Stages 2 and 3 valves; and c) the core makeup tank (CMT) minimum volume. The exemptions allow changes that impact Tier 1 of the plant-specific DCD and Appendix C of the facility COL, as specified in License Amendment Request (LAR)19-009. These exemptions are related to, and necessary for, the granting of the license amendments, which are being issued concurrently.

A copy of the related Safety Evaluation, which includes the staffs evaluation of the amendments, is enclosed. The notice of issuance of the amendment documents included in this letter will be published in the Federal Register.

Sincerely,

/RA/

Cayetano Santos, Senior Project Manager Vogtle Project Office Office of Nuclear Reactor Regulation Docket Nos.: 52-025 52-026

Enclosures:

1. Exemption for License Amendment No. 176 to VEGP Unit 3 COL
2. Exemption for License Amendment No. 175 to VEGP Unit 4 COL
3. Amendment No. 176 to VEGP Unit 3 COL
4. Amendment No. 175 to VEGP Unit 4 COL
5. Safety Evaluation cc: See next page

ML20049A655 - Package

  • via e-mail NRO-008 OFFICE NRR/ VPO:LA NRR/VPO:PM NRR/DSS/SNRB:BC NRR/DEX/EMIB:BC NAME RButler CSantos* (c)

RPatton*

TScarbrough* for SBailey DATE 2/20/20 2/24/20 2/21/20 2/21/20 OFFICE OGC/NLO NRR/VPO:BC (c)

NRR/DRA/APLC:BC NRR/DSS/STSB:BC NAME MWright*

VHall* (s)

SRosenberg*

VCusumano*

DATE 3/2/20 2/20/20 2/21/20 2/21/20 OFFICE NRR/VPO:D NRR/VPO:PM NRR/VPO:BC NAME MKing CSantos (s)

VHall (s)

DATE 3/11/20 3/11/20 3/11/20

Vogtle Mailing List (Revised 2/13/2020) cc:

Resident Manager Resident Inspector Oglethorpe Power Corporation Vogtle Plant Units 3 & 4 Alvin W. Vogtle Nuclear Plant 8805 River Road 7821 River Road Waynesboro, GA 30830 Waynesboro, GA 30830 Mr. Barty Simonton Office of the Attorney General Team Leader 40 Capitol Square, SW Environmental Radiation Program Atlanta, GA 30334 Air Protection Branch Environmental Protection Division Southern Nuclear Operating Company 4244 International Parkway, Suite 120 Document Control Coordinator Atlanta, GA 30354-3906 3535 Colonnade Parkway Birmingham, AL 35243 Brian H. Whitley Regulatory Affairs Director Anne F. Appleby Southern Nuclear Operating Company Olgethorpe Power Corporation 3535 Colonnade Parkway, BIN N-226-EC 2100 East Exchange Place Birmingham, AL 35243 Tucker, GA 30084 Mr. Michael Yox County Commissioner Site Regulatory Affairs Director Office of the County Commissioner Vogtle Units 3 & 4 Burke County Commission 7825 River Road, Building 302 (ESB)

Waynesboro, GA 30830 Bin 6031 Waynesboro, GA 30830 Mr. Wayne Guilfoyle Commissioner District 8 Augusta-Richmond County Commission 4940 Windsor Spring Rd Hephzibah, GA 30815 Gwendolyn Jackson Burke County Library 130 Highway 24 South Waynesboro, GA 30830 Mr. Reece McAlister Executive Secretary Georgia Public Service Commission Atlanta, GA 30334 Page 1 of 3

Vogtle Mailing List Email aagibson@southernco.com (Amanda Gibson) acchambe@southernco.com (Amy Chamberlian) gam@nei.org (Gia Montserrat)

Lindsay@georgiawand.org (Lindsay Harper) bhwhitley@southernco.com (Brian Whitley)

Bill.Jacobs@gdsassociates.com (Bill Jacobs) corletmm@westinghouse.com (Michael M. Corletti) crpierce@southernco.com (C.R. Pierce) dahjones@southernco.com (David Jones) david.hinds@ge.com (David Hinds) david.lewis@pillsburylaw.com (David Lewis) dlfulton@southernco.com (Dale Fulton) ed.burns@earthlink.net (Ed Burns) edavis@pegasusgroup.us (Ed David)

G2NDRMDC@southernco.com (SNC Document Control)

George.Taylor@opc.com (George Taylor) harperzs@westinghouse.com (Zachary S. Harper) james1.beard@ge.com (James Beard)

JHaswell@southernco.com (Jeremiah Haswell) jim@ncwarn.org (Jim Warren)

John.Bozga@nrc.gov (John Bozga)

Joseph_Hegner@dom.com (Joseph Hegner) karlg@att.net (Karl Gross) kmstacy@southernco.com (Kara Stacy) kroberts@southernco.com (Kelli Roberts)

KSutton@morganlewis.com (Kathryn M. Sutton) kwaugh@impact-net.org (Kenneth O. Waugh) markus.popa@hq.doe.gov (Markus Popa) mdmeier@southernco.com (Mike Meier) media@nei.org (Scott Peterson)

Melissa.Smith@Hq.Doe.Gov (Melissa Smith) mike.price@opc.com (M.W. Price)

MKWASHIN@southernco.com (MKWashington) mphumphr@southernco.com (Mark Humphrey)

MSF@nei.org (Marvin Fertel) nirsnet@nirs.org (Michael Mariotte)

Nuclaw@mindspring.com (Robert Temple)

Paul@beyondnuclear.org (Paul Gunter) pbessette@morganlewis.com (Paul Bessette) ppsena@southernco.com (Peter Sena,III) r.joshi15@comcast.net (Ravi Joshi) rwink@ameren.com (Roger Wink) sabinski@suddenlink.net (Steve A. Bennett)

Michelle@cleanenergy.org (Michelle Powell)

Page 2 of 3

Vogtle Mailing List sblanton@balch.com (Stanford Blanton)

Shiva.Granmayeh@hq.doe.gov (Shiva Granmayeh) sjackson@meagpower.org (Steven Jackson) sjones@psc.state.ga.us (Shemetha Jones) skauffman@mpr.com (Storm Kauffman) slieghty@southernco.com (Steve Leighty) sroetger@psc.state.ga.us (Steve Roetger) syagee@southernco.com (Stephanie Agee)

TomClements329@cs.com (Tom Clements)

Vanessa.quinn@dhs.gov (Vanessa Quinn) wayne.marquino@gmail.com (Wayne Marquino) weave1dw@westinghouse.com (Doug Weaver)

William.Birge@hq.doe.gov (William Birge)

X2edgran@southernco.com (Eddie R. Grant) x2gabeck@southernco.com (Gary Becker)

X2hagge@southern.com (Neil Haggerty)

X2wwill@southernco.com (Daniel Williamson)

Page 3 of 3