TECHNICAL SPECIFICATIONS FOR THE UNIVERSITY OF MASSACHUSETTS LOWELL RESEARCH REACTOR FACILITY OPERATING LICENSE NO. R-125
Contents 1.0 Introduction 1.1 Scope....................................................................................................................................................................... 1 1.2 Application.............................................................................................................................................................. 1 1.2.1 Purpose................................................................................................................................................................. 1 1.2.2 Format................................................................................................................................................................... 1 1.3 Definitions............................................................................................................................................................... 1 2.0 Safety Limit and Limiting Safety System Settings 2.1 Safety Limit............................................................................................................................................................. 6 2.2 Limiting Safety System Settings.............................................................................................................................. 6 2.2.1 Forced Convection Mode..................................................................................................................................... 6 2.2.2 Natural Convection Mode..................................................................................................................................... 7 3.0 Limiting Conditions For Operation 3.1 Reactor Core Parameters......................................................................................................................................... 9 3.1.1 Reactivity.............................................................................................................................................................. 9 3.1.2 Maximum Power Level...................................................................................................................................... 10 3.2 Reactor Control and Safety Systems..................................................................................................................... 10 3.2.1 Control Blade Scram Time................................................................................................................................. 10 3.2.2 Maximum Reactivity Insertion Rate and Regulating Rod Worth....................................................................... 11 3.2.3 Reactor Protection System Scram Channels....................................................................................................... 11 3.2.4 Radiological Protection Scrams.......................................................................................................................... 13 3.2.5 Minimum Channels Needed for Reactor Operation........................................................................................... 13 3.2.6 Reactor Control System Interlocks..................................................................................................................... 14 3.3 Reactor Coolant Systems...................................................................................................................................... 15 3.4 ConfinementContainment...................................................................................................................................... 16 3.5 Ventilation System................................................................................................................................................ 17 3.6 Radiation Monitoring Systems and Effluents........................................................................................................ 17 3.6.1 Radiation Monitoring.......................................................................................................................................... 17 3.6.2 Effluents............................................................................................................................................................. 18 3.7 Experiments........................................................................................................................................................... 19 3.7.1 Reactivity Limits................................................................................................................................................ 19 3.7.2 Design and Materials.......................................................................................................................................... 20 4.0 Surveillance Requirements 4.1 Reactor Core Parameters....................................................................................................................................... 21 4.1.1 Excessive Reactivity and Shutdown Margin...................................................................................................... 21 4.1.2 Fuel Elements..................................................................................................................................................... 21 4.2 Reactor Control and Safety Systems..................................................................................................................... 22 4.2.1 Control Rods....................................................................................................................................................... 22 4.2.2 Reactor Safety System........................................................................................................................................ 22 4.3 Coolant Systems.................................................................................................................................................... 24 4.4 ConfinementContainment...................................................................................................................................... 24 4.5 Ventilation Systems............................................................................................................................................... 25 4.6 Radiation Monitoring Equipment.......................................................................................................................... 26 5.0 Design Features 5.1 Site and Facility Description................................................................................................................................. 27 5.2 Reactor Coolant System........................................................................................................................................ 27 5.3 Reactor Core and Fuel........................................................................................................................................... 27 5.4 Fissionable Material Storage................................................................................................................................. 28 6.0 Administrative Controls 6.1 Organization.......................................................................................................................................................... 28 6.1.1 Structure............................................................................................................................................................. 28 6.1.2 Responsibility..................................................................................................................................................... 28 6.1.3 Staffing............................................................................................................................................................... 30 6.1.4 Selection and Training of Personnel................................................................................................................... 30 6.2 Review and Audit.................................................................................................................................................. 31
6.2.1 Composition and Qualifications......................................................................................................................... 31 6.2.2 Charter and Rules............................................................................................................................................... 31 6.2.3 Review Function................................................................................................................................................. 31 6.2.4 Audit Function.................................................................................................................................................... 32 6.3 Radiation Safety.................................................................................................................................................... 33 6.4 Operating Procedures............................................................................................................................................. 33 6.5 Experiment Review and Approval......................................................................................................................... 34 6.6 Required Actions................................................................................................................................................... 35 6.6.1 Actions to be Taken in the Event the Safety Limit Is Exceeded......................................................................... 35 6.6.2 Actions To Be Taken in the Event of a Reportable Occurrence......................................................................... 35 6.7 Reports................................................................................................................................................................... 36 6.7.1 Operating Reports............................................................................................................................................... 36 6.7.2 Special Reports................................................................................................................................................... 37 6.8 Records.................................................................................................................................................................. 37 6.8.1 Five-Year Record Retention............................................................................................................................... 37 6.8.2 Six-Year Record Retention................................................................................................................................. 38 6.8.3 Records To Be Retained for the Life of the Facility........................................................................................... 38
1
- 1. INTRODUCTION 1.1 Scope This document constitutes the technical specifications for The University of Massachusetts Lowell Research Reactor under facility license No. R-125. The technical specifications include definitions, safety limits, limiting safety system settings, limiting conditions for operation, surveillance requirements, design features, and administrative controls in accordance with 10 CFR 50.36. Also included are the bases for the technical specifications. The bases, which provide the technical support for the individual technical specifications, are for information purposes only. They are not part of the technical specifications, and they do not constitute limitations or requirements to which the licensee must adhere.
1.2 Application 1.2.1 Purpose The technical specifications represent the agreement between the licensee and the U.S.
Nuclear Regulatory Commission (NRC) on administrative controls, operational parameters, and equipment requirements, for safe reactor operation and for dealing with abnormal situations. They are typically derived from the safety analysis report (SAR).
These specifications represent a comprehensive envelope for safe operation. The operational parameters and equipment requirements directly related to preserving this safe envelope are included.
1.2.2 Format The format of this document is in general accordance with ANSI/ANS-15.1-2007.
1Property "ANSI code" (as page type) with input value "ANSI/ANS-15.1-2007.</br></br>1" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process..3 Definitions ADMINISTRATIVE CONTROLS - Those organizational and procedural requirements established by the NRC and/or the facility management.
CHANNEL - A channel is the combination of sensor, line, amplifier, and output devices that are connected for the purpose of measuring the value of a parameter.
CHANNEL CALIBRATION - A channel calibration is an adjustment of the channel such that its output corresponds with acceptable accuracy to known values of the parameter which the channel measures. Calibration shall encompass the entire channel, including equipment actuation, alarm, or trip and shall be deemed to include a channel test.
CHANNEL CHECK - A channel check is a qualitative verification of acceptable performance by observation of channel behavior, or by comparison of the channel with other independent channels or systems measuring the same parameter.
CHANNEL TEST - A channel test is the introduction of a signal into the channel for Comment [L1]: Added per mtg on 1/9/19
2 verification that it is operable.
CONFINEMENT - Confinement is an enclosure of the reactor building that is designed to limit the release of effluents between the enclosure and its external environment through controlled or defined pathways (see also Reactor Building).
CONTAINMENT - Containment is an enclosure of the facility designed to (1) be at a negative internal pressure to ensure in-leakage, (2) control the release of effluents to the environment, and (3) mitigate the consequences of certain analyzed accidents or events.
CONTAINMENT INTEGRITY - Integrity of the containment enclosure (reactor building) is said to be maintained when all isolation system equipment is either operable or secured in an isolating position.
CONTROL BLADE - See Rod, Control.
CORE CONFIGURATION - The core configuration includes the number, type, or arrangement of fuel elements, reflector elements, and control rods and regulating rod/
control / transient rods occupying the core grid.
EXCESS REACTIVITY - Excess reactivity is that amount of reactivity that would exist if all activity control blades and the regulating rod devices were moved to the maximum reactive condition from the point where the reactor is exactly critical (keff = 1) at reference core conditions and with all installed experiments in the most reactive conditionor at a specified set of conditions.
EXPERIMENT - Any operation, hardware, or target (excluding devices such as detectors, foils, etc.) that is designed to investigate non-routine reactor characteristics or that is intended for irradiation within the pool, on or in a beamport or irradiation facility.
Hardware rigidly secured to a core or shield structure so as to be a part of their design to carry out experiments is not normally considered an experiment.
LICENSE - The written authorization, by the NRC, for an individual or the organization to carry out the duties and responsibilities associated with a personnel position, material, or facility requiring licensing.
LICENSEE - An individual or organization holding a license.
MEASURED VALUE - The measured value is the value of a parameter as it appears on the output for a channel.
MOVABLE EXPERIMENT - A movable experiment is one where it is intended that all or part of the experiment may be moved in or near the core or into and out of the reactor while the reactor is operating.
OPERABLE - Operable means a component or system is capable of performing its Comment [lb2]: RAI 14.1.1 Comment [lb3]: RAI 14.1.2 Comment [L4]: RAI 14.1.3
3 intended function.
OPERATING - Operating means a component or system is performing its intended function.
OPERATIONS MODE - Operations mode refers to the method by which the reactor core is cooled, either natural convection mode or forced convection mode of operation.
PROTECTIVE ACTION - Protective action is the initiation of a signal or the operation of equipment within the reactor safety system in response to a parameter or condition of the reactor facility having reached a specific limit.
REACTIVITY WORTH OF AN EXPERIMENT - The reactivity worth of an experiment is the value of the reactivity change that results from the experiment, being inserted into or removed from its intended position.
REACTOR BUILDING - The reactor building is the enclosure housing the research reactor (see also Confinement).
REACTOR OPERATING - The reactor is operating whenever it is not secured or shut down.
REACTOR OPERATOR - An individual who is licensed by the NRC to manipulate the controls of the reactor.
REACTOR SAFETY SYSTEM - Reactor safety systems are those systems, including their associated input channels, that are designed to initiate automatic reactor protection or to provide information for initiation of manual protective action. The reactor safety system is also referred to as the reactor protection system.
REACTOR SECURED - The reactor is secured when:
(1)
Either there is insufficient moderator available in the reactor to attain criticality or there is insufficient fissile material present in the reactor to attain criticality under optimum available conditions of moderation and reflection; (2)
Or the following conditions exist:
(a) The minimum number of neutron absorbing control devices are fully inserted or other safety devices are in shutdown position, as required by technical specifications; (b) The console key switch is in the off position and the key is removed from the lock; (c) No work is in progress involving core fuel, core structure, installed control rods, or control rod drives unless they are physically decoupled Comment [lb5]: Added for consistent nomenclature
4 from the control rods; (d) No experiments are being moved or serviced that have, on movement, a reactivity worth exceeding the maximum value allowed for a single experiment (<0.5% k/k)., or one dollar, whichever is smaller.
REACTOR SHUTDOWN - The reactor is shut down if it is subcritical by at least one dollar (0.78%k/k) in the reference core condition with the reactivity worth of all installed experiments included.
REFERENCE CORE CONDITION - The condition of the core when it is at ambient temperature (cold) and the reactivity worth of xenon is negligible (<0.2% k/k).
RESEARCH REACTOR - The term research reactor as used in these Technical Specifications refers to the University of Massachusetts Lowell Research Reactor which is licensed by the U.S. Nuclear Regulatory Commission under license No. R-125. It is A research reactor is defined as a device designed to support a self-sustaining neutron chain reaction for research, developmental, educational, training, and experimental purposes and that may have provisions for the production of radioisotopes.
RESEARCH REACTOR FACILITY - Includes all those areas described in TS 5.1(2) within which the licensee owner or operator directs authorized activities associated with the reactor. For the UMLRR, the research reactor facility equates to the area within the reactor building. The terms research reactor facility and facility may be used interchangeably ROD, CONTROL - A control rod is a device fabricated from neutron-absorbing material or fuel, or both, that is used to establish neutron flux changes and to compensate for routine reactivity losses. A control rod can be coupled to its drive unit allowing it to perform a safety function when the coupling is disengaged. The terms control rod and control blade may be used interchangeably.
ROD, REGULATING - The regulating rod is a low worth control devicerod, used primarily to maintain an intended power level and does, that need not have scram capability. and may have a fueled follower. Its position may be varied manually or by a servo-controller.
SCRAM TIME - Scram time is the elapsed time between the initiation of a scram signal and a specified movement of a control or safety device.
SECURED EXPERIMENT - A secured experiment is any experiment, experimental apparatus, or component of an experiment that is held in a stationary position relative to the reactor by mechanical means. The restraining forces must be substantially greater than those to which the experiment might be subjected by hydraulic, pneumatic, buoyant, or other forces that are normal to the operating environment of the experiment, or by forces that can arise as a result of credible malfunctions.
Comment [lb6]: RAI 14.1.4 Comment [lb7]: RAI 14.1.9. Revised for same wording ANSI 15.1 Comment [lb8]: Revised for same wording as ANSI 15.1 and includes wording suggested in mtg on 1/9/19 Comment [lb9]: RAI 14.1.5 Comment [lb10]: RAI 14.1.6
5 SENIOR REACTOR OPERATOR - An individual who is licensed to direct the activities of reactor operators. Such an individual is also a reactor operator.
SHALL, SHOULD, AND MAY - The word "shall" is used to denote a requirement; the word "should" is used to denote a recommendation; and the word "may" is used to denote permission, neither a requirement nor a recommendation.
SHUTDOWN MARGIN - Shutdown margin is the minimum shutdown reactivity necessary to provide confidence that the reactor can be made subcritical by means of the control and safety systems starting from any permissible operating condition and with the most reactive control blade and regulating rod in the most reactive position, and the non-scramable rods in their most reactive positions and that the reactor will remain subcritical without further operatorion action.
SITE - The UMLRR site includes the reactor confinementcontainment building and the attached academic building (see also Research Reactor FacilityPinanski Hall).
SURVEILLANCE TIME INTERVALS - The maximum allowable intervals listed as follows are to provide operational flexibility only. Established frequencies shall be maintained over the long term. Any extension of these intervals shall be occasional and for a valid reason.
- 5 Year (interval not to exceed 6 years)
- Biennial (interval not to exceed 30 months)
- Annual (interval not to exceed 15 months)
- Semiannual (interval not to exceed 7-1/2 months)
- Quarterly (interval not to exceed 4 months)
- Monthly (interval not to exceed 6 weeks)
- Weekly (interval not to exceed 10 days)
- Daily (shall be done during the same working day)
- Prior to the first reactor start-up of the day TRUE VALUE - The true value is the actual value of a parameter.
UNSCHEDULED SHUTDOWN - An unscheduled shutdown is defined as any unplanned shutdown of the reactor caused by actuation of the reactor safety system, operator error, equipment malfunction, or a manual shutdown in response to conditions that could adversely affect safe operation, not including shutdowns that occur during testing or checkout operations.
Comment [lb11]: RAI 14.1.7 Comment [L12]: RAI 14.1.8. Added to provide consistency among definitions and references Comment [L13]: Consistent with ANS15.1
6 End Definitions 2.0 SAFETY LIMIT AND LIMITING SAFETY SYSTEM SETTINGS 2.1 SAFETY LIMIT Applicability:
This specification applies to the reactor fuelonset of nucleate boiling (ONB) at the hot spot in the hot channel of the reactor fuel, in either forced or natural convection mode of operation.
Objective:
The objective is to ensure that the integrity of the fuel cladding is maintained.
Specification:
The reactor fuel clad temperature shall be less than 530118°C (986244°F).
Bases:
The melting temperature of aluminum is 660°C (1220°F). Fuel damage occurs with blister formation. The blister threshold temperature for both uranium silicide and uranium aluminide fuel is above 53000°C (98632°F) (NUREG-1313). Establishing a maximum fuel clad temperature below 118°C (the minimum temperature for the onset of nucleate boiling - ONB), provides nearly a 400°C temperature margin before fuel blistering occurs. There is no possibility for clad or fuel damage at the Safety Limit.
2.2 LIMITING SAFETY SYSTEM SETTINGS 2.2.1 Forced Convection Mode Applicability This specification applies to the setpoints for the safety channels monitoring reactor thermal power, coolant flow rate, reactor coolant inlet temperature, and the height of water above the center line of the core under the condition of the Comment [lb14]: RAI 14.2.1
7 forced convection mode of operation.
Objective To ensure that automatic protective action is initiated in order to prevent the Safety Limit from being exceeded.
Specifications (1)
The Limitinged Safety System Setting for the reactor power level shall initiate automatic protective action at or below a measured value of 1.15 MWt.
(2)
The Limitinged Safety System Setting for the primary coolant flow shall initiate automatic protective action at or above a measured value of 1400 GPM.
(3)
The Limitinged Safety System Setting for the primary coolant inlet temperature shall initiate automatic protective action at or below a measured temperature of 108 oF.
(4)
The Limitinged Safety System Setting for pool height above the core centerline shall initiate automatic protective action at or above a measured value of 24.25 ft.
Bases The Limiting Safety System Settings (LSSS) for forced convection mode are set points which if reached, will cause an automatic protective action to prevent the Safety Limit (SL) from being exceeded during the course of the most adverse anticipated transient. The LSSS values for this specification are more conservative than the values used in both the analyses for steady-state (SAR 4.6) and various transient conditions (SAR 13.2.2). Of the transient conditions analyzed, the step-reactivity addition is the most limiting condition. Using values for the variables more conservative than those in this specification, and using a step reactivity value greater than the maximum reactivity value for a single secured experiment given in Specification 3.7.1, the analysis found the step-reactivity transient will not lead to an onset of nucleate boiling (ONB) before the reactor protection system begins to shut down the transient. The ONB limit provides an adequate margin to ensure the SL is not reached.These Limiting Safety System Settings (LSSS) represent values of the interrelated variables which, if reached, shall result in an automatic protective action that will prevent the Safety Limit from being exceeded during the course of the most adverse anticipated transient. The values in this specification take into account the uncertainty in the measurement. To determine the LSSS values for this specification, steady-state and various transient conditions were analyzed, Comment [lb15]: RAI 14.2.2
8 including: step reactivity addition, ramp reactivity insertion, loss of forced convection flow, and cold water insertion. Of the transient conditions analyzed, the step-reactivity addition is the most limiting condition. Using the values of the variables given above, without the uncertainty correction, and using a step-reactivity value greater than the maximum reactivity value for a single secured experiment given in Specification 3.7.1, the step-reactivity transient will not lead to ONB before the reactor protective system begins to shut down the transient (SAR 13.2.2).
2.2.2 Natural Convection Mode Applicability This specification applies to the setpoints for the safety channels monitoring reactor thermal power, reactor pool temperature, and the height of water above the center line of the core under the condition of the natural convection mode of operation.
Objective To ensure that automatic protective action is initiated in order to prevent undesirable radiation levels on the surface of the pool.
Specification (1)
The Limited Safety System Setting for the reactor power level shall initiate automatic protective action at or below a measured value of 115 kWt.
(2)
The Limited Safety System Setting for the pool temperature shall initiate automatic protective action at or below a measured temperature of 108 oF.
(3)
The Limited Safety System Setting for pool height above the core centerline shall initiate automatic protective action at or above a measured value of 24.25 ft.
Bases The Limiting Safety System Settings (LSSS) for natural convection mode are set points which if reached, will cause an automatic protective action to prevent undesirable radiation levels on the surface of the pool due to the production and escape of 16N during the natural convection mode of operation. The specifications also ensure an adequate safety margin exists between the LSSS and the SL for natural convection. The value for the power LSSS would be much higher (>200 kW, SAR 4.5) if the specifications were based on ONB rather than on 16N production (see Bases for Forced Convection).These Limiting Safety System Settings (LSSS) represent values of the interrelated variables which, if exceeded, shall result in automatic protective actions that will prevent undesirable radiation levels on the surface of the pool due to the production and escape of 16N
9 during natural convection mode of operation. The specifications given above also ensure an adequate safety margin exists between the LSSS and the SL for natural convection. The value for the power LSSS would be much higher (248 kW, SAR Chapter4.5) if the specifications were based on the Safety Limit rather than on 16N production. The 16N criterion is not related to ONB which was the criterion used in establishing the Safety Limit.
End Section 2.
3.0 LIMITING CONDITIONS FOR OPERATION 3.1 REACTOR CORE PARAMETERS 3.1.1 Reactivity and Core Configuration Applicability These specifications apply to the reactivity, core configuration, and other conditions associated withof the reactor and the reactivity worths of control rods, regulating rod, and experiments.
Objective To ensure that the reactor can be safely operated and shutdown and maintained in a safe shutdown condition at all times suchand that the Safety Limit will not be exceeded.
Comment [lb16]: Change reflects additions to the specification in response to RAIs
10 Specification The reactor shall not be operated unless When the reactor is operating, the following conditions shall exist:
(1)
The reactor core is loaded so that Tthe excess reactivity in the reference core cold clean (xenon free) critical condition shall be <4.7% k/k.
(2)
The minimum shutdown margin relative to the cold, clean (xenon free) critical condition, with the most reactive control rod in the fully withdrawn position, shall be >12.7% k/k with:. the most reactive control blade and regulating blade in their fully withdrawn position; the total worth of all installed experiments in their most reactive state; and the reactor in the reference core condition.
(3)
All core grid positions shall beare filled with fuel elements, irradiation baskets, source holders, regulating rod, graphite reflector elements, lead void boxes, or grid plugs.
(4)
All but 5 of the peripheral No more than five (5) radiation baskets shallmust be without contain flow restricting devices. This specification shallwill not apply for low power operation <100 kW without forced flow.
The reactivity coefficients (fuel temperature, moderator temperature, and void) shall be negative over the normal operating moderator temperature range of 20 °C to 42 °C (68 °F - 108°F).
(5) The reactor shall not be knowingly operated with damaged fuel except as may be necessary to identify the location of the damaged fuel.
(5)(6) The reactor shall not be operated whenever the reactor core is in the same end of the reactor pool as any portion of the cobalt-60 source.
Bases The maximum allowed excess reactivity of provides sufficient reactivity to accommodate fuel burnup, xenon and samarium poisoning buildup, experiments, and control requirements, but gives a sufficient shutdown margin even with the highest worth rod fully withdrawn. The minimum shutdown margin ensures that the reactor can be shut down from any operating condition and will remain shutdown after cooldown and xenon decay, even if the highest worth control blade and regulating rod should be in the fully withdrawn position. The requirement that all grid plate positions be filled and the restriction on radiation baskets during reactor operation ensures that the quantity of primary coolant which bypasses the heat producing elements will be kept within the limits used in establishing the Safety Limit in Chapter 13 of the SAR. This requirement does not apply under Comment [lb17]: RAI 14.3.1 Comment [lb18]: RAI 14.3.2 Comment [lb19]: RAI 14.3.3 Comment [L20]: RAI 14.3.4 Comment [L21]: Was to be moved to section 5, but removed all together per discussions at mtg on 1/9/19 Comment [lb22]: RAI 14.3.5 Comment [L23]: Moved from 3.7.2(2)
11 natural circulation conditions at power levels less than 100kW. The requirements for negative coefficients of reactivity ensure that any temperature rise or void caused by a reactor transient will not cause a further increase in reactivity. Fuel elements are initially inspected in accordance with written procedures to assure the fuel elements are not damaged. In-core fuel elements are periodically re-inspected. The primary coolant is periodically analyzed to monitor for fission products. Fuel elements with known defects would be removed from the core. The presence of Co-60 sources near the reactor may cause interference with the power measuring detectors, particularly at low power levels.
3.1.2 Maximum Power Level Applicability:
This specification applies to the reactor thermal power level.
Objective:
To ensure that the safety limit is not exceeded.
Specification:
The reactor shall not be continuously operated at a power level exceeding 1MWt.
Basis:
Thermal hydraulic calculations presented in Chapter 13 of the SAR demonstrate that the fuel may be safely operated at power levels up to 1.25 MW. The LSSS specification in 2.2.1.1 takes into account the reactor power measurement uncertainty. Automatic protective action would be initiated at or below that value. Momentary drifts of power level beyond 1MWt would be corrected by the reactor operator.
3.2 REACTOR CONTROL AND SAFETY SYSTEMS 3.2.1 Control Blades Scram Time Applicability This specification applies to the reactor control blades.elapsed time from the initiation of a scram signal to when the control rod is considered fully inserted.
Objective:
To specify the minimum number of operable control blades and their maximum scram time to ensure the reactor can be shutdown and the Safety Limit is not exceeded.ensure that the reactor can be shutdown within the specified period of time.
Specification
- 1.
All four control blades shall be operable when the reactor is operating.
1.2.
The time from initiation of a scram signal and movement of each control blade from the fully withdrawn position to 80% of the fully inserted position shall be less than one second.
Comment [lb24]: Change to accommodate addition for RAI 14.3.6 Comment [L25]: RAI 14.3.6
12 Bases The UMLRR is equipped with four control blades and one regulating rod as described in SAR 4.2.2. The control blades are connected to their drives by electromagnets and hence drop by gravity into the core upon initiation of a scram signal. The last few inches of travel are dampened to prevent damage to the control blade due to its momentum. Analyses in Chapter 13 of the SAR show that for the most limiting transient, the peak clad temperature is well below the ONB point during the 1.0 second scram time interval. The analyses also assume only 3 of the 4 control blades are scrammed. For added conservativeness, the specification requires all four control blades to be operable.
3.2.2 Maximum Reactivity Insertion Rate and Regulating Rod Worth Applicability:
This specification applies to the maximum positive reactivity insertion rate by the most reactive control rod and the regulating rod simultaneously.
Objective:
To ensure that the reactor is operated safely and the safety limit is not exceeded during any credible ramp reactivity insertion.
Specification:
(1)
The maximum reactivity insertion rate by the most reactive control bladerod and the regulating rod simultaneously shall not exceed 0.05% k/k per second.
(2)
The total reactivity worth of the regulating rod shall be < 0.5% k/k.
(2)(3) Only one control blade shall be withdrawn at a time.
Basis:
The maximum reactivity insertion rate limit and requirement for withdrawal of only one control at a time ensures that the safety limit will not be exceeded as a result of a continuous linear reactivity insertion. Analyses in Chapter 13.2 of the SAR show that the peak clad temperature would be well below the ONB point even under the conservative assumption that the reactor is operating at the LSSS values for power and temperature when the ramp begins and using a reactivity addition rate greater than that allowed by the specification. An analysis of a step insertion >0.5% k/k also is given in Chapter 13.2 of the SAR. The analysis shows the step-reactivity transient will not lead to ONB before the reactor protective system begins to shut down the transient. Limiting the reactivity worth of the regulating rod to this value ensures that any failure of the automatic servo control system could not result in the Safety Limit being exceeded.
Comment [L26]: RAI 14.3.14
13 3.2.3 Reactor Protection System Scrams Channels and Scram Switches Applicability This specification applies to the reactor protection system. channels.
Objective To stipulate the minimum number of reactor protection system scrams channels and scram switches that shall be operable to ensure that the safety limit is not exceeded.
Specification The reactor shall not be operated unless the reactor protection system scramschannels described in the following Ttable 3.2.3-1 are operable:
Table 3.2.3-1 Minimum Reactor Protection System Scrams Forced Convection Mode Natural Convection Mode ScramsChannel Function Minimum Required Function Minimum Required
- 1.
Reactor Period Scram at < 3 second period 1
Scram at < 3 second period 1
- 2.
Reactor Power Level Scram at > 1.15 MW 2
Scram at >115kW 2
- 3.
Primary Coolant Flow Rate Scram at <1400 GPM 1
n/a n/a
- 4.
Pool Water Level Scram at < 24.25 ft above core centerline 1
Scram at < 24.25 ft above core centerline 1
- 5.
Pool Inlet Temperature Scram > 108oF 1
n/a n/a
- 6.
Pool Temperature Scram > 108oF 1
Scram > 108oF 1
- 7.
Control Room Manual Scram Button Scram if depressed 1
Scram if depressed 1
- 87.
Detector High Voltage (each period and power channel)
Scram < 500 V 1
Scram < 500 V 1
- 98.
Seismic Disturbance Scram on seismic motionModified Mercali Scale IV 1
Scram on seismic motionat Modified Mercali Scale IV 1
109.
Bridge Movement Scram if moved >
1 inch 1
Scram if moved >
1 inch 1
- 10.
Manual Scram Button Scram if depressed 1
Scram if depressed 1
- 11.
Reactor On Scram at off 1
Scram at off 1
Comment [L27]: RAI 14.3.7 Comment [L28]: Various changes to this table per RAI 14.3.19 & 14.3.33, and better grouping Comment [L29]: See RAI response 14.4.10 Comment [L30]: See RAI response 14.4.12
14 Key Switch position position 112.
Drives Controls Display Watch Dog Timer Scram for communication loss >10 second 1
Scram for communication loss >10 second 1
123.
Process Controls Display Watch Dog Timer Scram for communication loss >10 second 1
Scram for communication loss >10 second 1
13 Primary Piping Alignment Scram when alignment limit switches not met 1
n/a n/a 14 Riser Coolant Gate Open Scram when gate opens in cross-pool mode 1
n/a n/a 15 Coolant Gate Open Scram when either gate opens in downcomer mode 2
n/a n/a Bases The automatic protective action initiated by the reactor period channel, the reactor power level channels, the flow rate channel, the pool water level channel, the pool inlet temperature channel, and the pool coolant temperature channels all provide redundant protection to ensure that the Safety Limit is not exceeded. The manual scram button provides a manual method to shutdown the reactor if the operator determines an unsafe condition has occurred or could occur. Automatic protection action initiated by a detector high voltage failure, a seismic event, or the reactor bridge misalignment, or displays watchdog timers ensures a reactor shutdown occurs for potential instrumentation problems. Automatic protection action initiated by a seismic event assures the reactor will be shutdown should structural or system damage occur due to seismic activity. The bridge movement, primary piping alignment, and coolant gate trips assure adequate coolant flow is maintained in the reactor core during forced convection operations. or unsafe conditions. The manual scram button and the "Reactor On" key switch provide two manual scram methods to shutdown the reactor if the operator determines an unsafe condition has occurred or could occur.
3.2.4 Radiological Protection Scrams Applicability This specification applies to reactor scrams associated with radiological protection.
Objective Radiological protection scrams are incorporated in the scram circuit to protect personnel, the public, and the environment from possible radiation exposure.
Specification The reactor shall not be operated unless the following radiological protection scrams described in the following Ttable 3.2.4-1 are operable.
Comment [lb31]: Value should have been 10s.
Also consistent with RINSC TS (similar displays)
Comment [L32]: RAI 14.3.33
15 Table 3.2.4-1 Radiological Protection System Scrams ScramChannel Function Minimum Required
- 1.
Area Radiation Monitoring System Scram on High Radiation Levels 1
- 2.
Thermal Column Door Open Scram if door limit switch open 1
- 3.
Beamport Chamber Door Open Scram if door limit switch open 1
- 4.
First Floor Airlock Integrity Scram if both doors unsealed 1
- 5.
Third Floor Airlock Integrity Scram if both doors unsealed 1
- 6.
Truck Door Seal Scram if door unsealed 1
Bases The radiological protection scrams minimize the possibility of exceeding 10 CFR Part 20 limits for radiation exposure.
3.2.5 Minimum Channels Needed for Reactor Operation Applicability This specification applies to channels in the reactor protection and control systems.
Objective To stipulate the minimum number of channels that shall be operable to ensure that the reactor operator has sufficient information for safe operation of the reactor.
Specification The reactor shall not be operated unless the channels in the following tTable 3.2.5-1 are operable.
Table 3.2.5-1 Minimum Reactor Protection Channels Channel Operations Mode Minimum Required
- 1.
Start-up Count Rate Both 1
- 2.
Reactor Period Both 1
- 3.
Reactor Linear Power Level Both 12
- 4.
Reactor Log Power Level Both 1
- 54.
Primary Coolant Flow Rate Forced 1
- 65.
Pool Water Level Both 1
- 76.
Pool Inlet Temperature Forced 1
- 87.
Pool Temperature Both 1
Bases The channels listed in the above table ensure that measurements of the reactor power level and the process variables are adequately displayed during reactor startup and during low-power natural convection and high-power forced Comment [lb33]: See RAI response 14.3.10 Comment [L34]: Changes to power measuring channels made to ensure diversity per mtg 1/9/19
16 convection modes of operation.
3.2.6 Reactor Control System Interlocks Applicability This specification applies to the reactor control system.
Objective To stipulate the minimum number of interlocks availableis provided to inhibit control bladerod withdrawal. if the limiting conditions in Specifications 3.2.3, 3.2.4, and 3.2.5 are not met.
Specification The following interlocks to prevent control blade withdrawal shall be operable when the reactor is operating:The following interlocks to prevent rod withdrawal shall be operable:
- 1)
Scram circuit not reset.
- 2)
Start-up neutron count rate is < 2 counts per second. via proportional counter or < 10 counts per second via wide range log-power module.
- 3)
The reactor period <15 seconds.
Bases The requirement for the scram circuit to be reset ensures that reactor facility conditions are normal and radiological hazards are minimized. The inhibit function for startup neutron count rate ensures the required startup neutron source is sufficient and in a proper location for reactor startup, such that a minimum source multiplication count rate level is being detected. The inhibit function for the reactor period channel limits the rate of power increase when withdrawing a control rod and Keff >1.
3.3 REACTOR COOLANT SYSTEMS Applicability This specification applies to the reactor primary coolant system water quality requirements and pool configuration.
Objective The objectives are to minimize corrosion and radioactive contaminants, and to ensure the full volume of pool water is available in the event of a loss of coolant accident. to monitor the integrity of the fuel cladding and the cobalt-60 sources.
Comment [L35]: See response to RAI 14.3.13
17 Specification The reactor shall not be operated under any of the following conditions:
(1)
TThe conductivity of the pool water, averaged over the previous two weeks, is shall be >5<10 µmho/cm.
(2)
TThe pH of the pool water is shall be between <5.0 orand >7.58.0.
(3)
The pool water shall be analyzed for gross activity and for cobalt-60.
Analysis shall be capable of detecting levels of 10-7 µCi per milliliter. If a sample analysis reveals a significant increase of activity in the water, with respect to the previous samples, or a contamination level greater than 10-6
µCi of cobalt-60 per milliliter of water, prompt action shall be taken to prevent further contamination of the pool water. If the gross activity of the sample is less than 10-7 µCi per milliliter, specific analysis for cobalt-60 need not be performed. If remedial action is required by this section, notification will be made to the USNRC as required by Section 6.6.2.
The concentrations of radionuclides in the bulk pool water meet or exceed the values presented for water in 10 CFR Appendix B to Part 20 Table 2. If such a condition occurs, the source of the radionuclide(s) shall be identified and corrected.
(4) The pool divider gate is in position to separate the bulk pool and the stall pool.
Bases Pool water of high purity minimizes the rate of corrosion and minimizes neutron activation of impurities. The purpose of a pH limitmonitoring is to minimizeensure that corrosion of the fuel, core components, and the primary coolant loop structure is maintained within an acceptable limit. The fuel cladding, core structure, pool liner, and primary piping are all made of aluminum alloy. A portion of the primary coolant loop is constructed of stainless steel. Lower pH will reduce aluminum alloy corrosion and oxide formation. Higher pH is favored to control stainless steel corrosion. Thus, a pH range between 5 and 7.58 is selected for the primary coolant. Electrical conductivity is also monitored to control purity of the primary coolant. A limit of 510 µmho/cm average is adopted from historic experience. Since 1974, the conductivity typically has been below 5 mho/cm. No corrosion issues have ever been identified with either the fuel or the core structural materials. Conductivity may occasionally and briefly exceedapproach the higher limit immediately following regeneration of the water purification system. Radionuclide analysis of the pool water allows for early determination of any significant buildup of radioactivity from operation of the reactor or the cobalt-60 source. Specifying the pool gate not be in position to isolate the bulk and stall pools during reactor operations assures the entire pool volume and surface area is available for cooling in normal and off-normal Comment [L36]: See response RAI 14.3.16 Comment [L37]: RAI 14.3.19
18 conditions.
3.4 CONFINEMENT CONTAINMENT 3.4.1 Operations Requiring Confinement Applicability This specification applies to the reactor building. operation of the reactor containment building isolation system and the emergency exhaust system.
Objective To restrict the release of airborne radioactive material into the environment in the event of an accident.To ensure that the containment and emergency exhaust system is in operation to mitigate the consequences of possible release of radioactive materials.
Specification Confinement Containment integrity shall be maintained for any of the following conditions:
(1)
The reactor is not secured. shutdown.
(2)
Movement of irradiated fuel is being performed, except when the fuel is in a properly sealed and approved shipping container.
(3)
The handling of radioactive material with the potential for significant airborne release. reactor shall not be operated unless the following equipment is operable and conditions met:
Equipment Function
- 1.
At least one door in each of the personnel air locks is sealed and the truck door is sealed.
To maintain containment integrity.
- 2.
All isolation valves, except that reactor operation can proceed if a failed isolation valve is in the closed (isolated) position.
To maintain containment integrity.
- 3.
Initiation system for containment isolation.
To maintain containment integrity.
- 4.
Emergency exhaust system To maintain the ability to tend toward a negative building pressure without unloading any large fraction of possible airborne radioactivity.
- 5.
Vacuum relief device.
To ensure that building vacuum will not exceed 0.2 psi.
Comment [L38]: Revisions per RAI 14.3.21
19 Bases Confinement provides means to isolate and release effluents through a controlled pathway, thereby mitigating possible radiological exposures to the public or workers. Reactor operation requires building confinement due to a remote possibility for the release of radioactive gasses or airborne particulates. It is not required when the reactor is shutdown. The movement of irradiated fuel introduces a remote possibility of fuel cladding damage. The handling of radioactive materials consisting of volatile, gaseous, or particulate components has the potential for creating an airborne release beyond 10CFR Part 20 Appendix B values for airborne radioactivity.
In the unlikely event of a release of fission products, or other airborne radioactivity, the containment isolation initiation system will secure the normal ventilation exhaust fan, will bypass the normal ventilation supply up the stack, and will close the normal inlet and exhaust valves. In containment, the emergency exhaust system will tend to maintain a negative building pressure with a combination of controls intended to prevent unloading any large fraction of airborne activity if the internal building pressure is high. The emergency exhaust purges the building air through charcoal and absolute filters and controls the discharge, which is diluted by supply air, through a 100 foot stack on site.
Chapter 6 of the SAR describes the system's sequence of operation. Chapter 13 provides the analysis for the maximum hypothetical accident (MHA).
3.4.2 Conditions Needed to Achieve Confinement Applicability:
This specification applies to the reactor building equipment required to achieve a confinement configuration.
Objective:
To prevent the release of reactor building exhaust air through other than defined pathways.
Specification:
For any of the conditions in specification 3.4.1, the following equipment requirements shall be met:
(1) At least one door in each of the personnel air locks is sealed and the truck door is sealed.
(2) All ventilation isolation valves are either operable or in the closed (isolated) position.
Bases:
Effective confinement is achieved by maintaining a negative building pressure or by completely sealing the building. Chapter 6 of the SAR describes the building isolation equipment operation. The reactor building personnel airlocks and truck Comment [L39]: RAI 14.3.22
20 door are not provided with automatic closure devices. Confinement cannot be maintained if any of these portals are open to the outside atmosphere. The confinement building normal ventilation valves are designed to automatically seal upon an initiating signal from the Radiation Monitoring System or manual signal by the operator. If one or more ventilation valves are closed in the sealed position, then automatic isolation of that valve (or valves) is unnecessary.
3.5 VENTILATION SYSTEM Applicability:
This specification applies to the normal and emergency exhaust ventilation equipment.systems that exhausts building air to the outside environment.
Objective:
To maintain a controlled pathway for reactor building exhaust air and minimize exposures from a release of airborne radioactive materials. provide for normal ventilation and the reduction of airborne radioactivity within the reactor building during normal reactor operation and to provide a way to turn off the main ventilation exhaust fan quickly in order to isolate the building for emergencies.
Specification:
For any of the operations specified in 3.4.1:
(1)
The main intake fan shall be operatingoperable whenever the reactor is operating.
(2) The reactor building pressure shall be at or more negative than 0.1 inch water column.
(3) The emergency exhaust system shall be operable.
(4) The emergency exhaust system charcoal filter shall have an efficiency of 95%
or greater.
(1)
The main exhaust fan automatic and manual isolation controls shall be operable whenever the reactor is operating.
(3) The reactor may be operated with the main exhaust fan inoperable provided documented verbal concurrence from the Radiation Safety Officer is made.
Comment [L40]: See response to RAI 14.3.22
21 Bases:
The main intake fan provides fresh air to the confinement building, or under the condition where building isolation occurs (see Chapter 6), dilution air up the stack. The main exhaust fan is designed to operate at a flow rate greater than the main intake fan in order to produce negative pressure in the building.
In the event the main exhaust fan is not operating, the isolation valves are interlocked to divert the main intake up the stack. Negative building pressure can be maintained by one or a combination of smaller exhaust fans. Chapter 6 of the SAR describes the ventilation systems sequence of operation. In the unlikely event of a release of fission products or other airborne radioactivity, an isolation signal from the Radiation Monitoring System, the shutdown the main exhaust fan and close the building ventilation valves. The emergency exhaust system will start and purge the building air through charcoal and absolute filters, which is then diluted by the diverted intake air through the 100 foot exhaust stack.
3.6 RADIATION MONITORING SYSTEMS AND EFFLUENTS 3.6.1 Radiation Monitoring Applicability This specification applies to the availability of radiation monitoring equipment which must be operable during reactor operation.
Objective To ensure that radiation monitoring equipment is available for evaluation of radiation conditions in restricted and unrestricted areas.
Specification (1)
For any of the conditions in specification 3.4.1, When the reactor is operating, the following minimum radiation monitors shall be operatingable with readouts and alarm indicators in the control room:
(a) A sStack gaseous and stack particulates effluent radiation monitors.
(b) A constant air monitor, located on the reactor pool level (third floor).
(c) An area radiation monitor on the reactor experimental level (first floor).
(d) An area radiation monitor over the reactor pool.
Comment [L41]: Revisions per RAI 14.3.23
22 The reactor shall be shut down within 15 minutes upon recognition that any of Specifications (a) through (d) is unmet, unless a portable instrument having an alarm feature capable of warning personnel of a high radiation level is substituted and readings are physically checked and recorded every 15 minutes.
(2)
The facility wide radiation warning alarms shall be operable to ensure that proper emergency action is taken. The public address system may serve as a temporary substitute for the facility wide radiation alarms.
(2) Each gamma irradiation facility shall have an operating area radiation monitor having a readout and alarm indicator in the control room when irradiations are performed.
(3) If a required radiation monitor becomes inoperable, operations may continue only if the monitor can be repaired or replaced with a monitor of similar function within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of discovery.
(4) There shall be an environmental monitoring program that shall include the placement of dosimeters, or other devices at points outside the reactor building.
Bases The radiation monitoring system is described in Section 7.7 of the SAR.
Specifications 1 and 2 provides the minimum equipment for evaluating the radiation levels within the stack effluent and within the reactor building.
Specification 32 provides a reasonable time period to take corrective action after a failure of the minimum equipment is recognized. Specification 4 provides a means to assure exposures outside the restricted area are within regulatory limits.3 provides for the facility wide annunciation of elevated radiation conditions. The public address system used by the reactor operator serves as a reasonable temporary substitute for the alarms if needed.
3.6.2 Effluents Applicability:
This specification applies to the monitoring and control of radioactive effluents from the reactor buildingfacility.
Objectives:
To ensure that releases of liquid and airborne effluents are within 10 CFR Part 20 limits.
Specification:
Comment [L42]: RAI 14.3.24. Replaced by #3 below Comment [L43]: See response to RAI 14.3.25 Comment [L44]: RAI 14.3.26
23 (1)
The discharge of licensed material into sanitary sewage shall meet the requirements of 10 CFR 20.2003(a), Disposal by Release into Sanitary Sewerage.concentration of radioactive liquids released into the sanitary sewer shall not exceed the limits specified in 10 CFR Part 20.
(2)
The concentration of argon-41 at ground level below the point of release into the unrestricted area shall not exceed the unrestricted area effluent concentration limit in 10 CFR Part 20 Appendix B, Table 2, Column 1 for argon-41 when averaged over 1 year. or 10 times the effluent concentration limit when averaged over 1 day.
(3)
The concentration of argon-41 in the restricted area shall not exceed the 10 CFR Part 20 DAC for argon-41 when averaged over a 2000-hour work year.
Bases:
For specification 1, Chapter 11 of the SAR evaluates liquid releases into the sanitary sewer system. For specifications 2 & 3, Chapter 11 of the SAR evaluates the release of argon-41 in the restricted and unrestricted areas. For continuous full power operations, the analyses show that the maximum dose from Ar-41 would be approximately 13 mrem for an individual located in the parking lot (an unrestricted area) continuously for 1 year, and assuming the most conservative atmospheric conditions. For a worker inside the restricted area, the derived air concentration has been analyzed to be approximately one half the 10CFR Part 20 Appendix B Table 1 DAC limit for Ar-41.
3.7 EXPERIMENTS Applicability This specification applies to experiments to be installed in the reactor and associated experimental facilities.
Objective To prevent damage to the reactor or excessive release of radioactive materials in the event of an experiment failure.
3.7.1 Reactivity Limits Specification The reactivity worth of experiments shall not exceed the values indicated in the following table:
Table 3.7.1-1 Experiment Reactivity Limits Comment [L45]: RAI 14.3.27 Comment [L46]: See response to RAI 14.3.28 Comment [L47]: Revisions per RAI 14.3.29
24 Type Single Experiment Worth Total Worth Movable (including pneumatic rabbit) 0.25% k/k 0.5% k/k Secured 0.5% k/k 2.5% k/k (1)
The total reactivity worth of all experiments shall not be greater than 2.5%k/k.
(1)
The absolute value of reactivity worth of any single movable experiment shall not exceed 0.25%k/k.
(2)
The sum total absolute value of reactivity worth of all movable experiments shall not exceed 0.5%k/k.
(3)
The absolute value reactivity worth of any single secured experiment shall not exceed 0.5%k/k.
(4)
The sum total absolute reactivity worth of all secured experiments shall not exceed 2.5%k/k.
(5)
The sum absolute value of reactivity worth of all experiments shall not be greater than 2.5%k/k.
Bases Specification (1) ensures that the failure of a single experiment will not result in exceeding the Safety Limit. The analysis of a step insertion >0.5% k/k is given in Chapter 13 of the SAR. The analysis shows the step-reactivity transient will not lead to ONB before the reactor protective system begins to shut down the transient. The total reactivity of 2.5% in Specification (2) places a reasonable upper limit on the worth of all experiments which is compatible with the allowable excess reactivity and the shutdown margin and is consistent with the functional mission of the reactor.
3.7.2 Design and Materials Specification Experiments irradiated with either neutrons from the reactor or gamma rays from the Co-60 sources shall conform to the following: The reactor shall not be operated unless the following conditions governing experiments exist:
(1)
Experimental apparatus, material or equipment to be irradiated in the reactor shall not cause shadowing of the reactor nuclear instrumentation, interference with control rods, or other perturbations which may interfere with the safe operation of the reactor.
Comment [lb48]: See response RAI 14.3.30 also consistent with RAI 14.6.1.
Comment [lb49]: Redundant covered by (1) that uses ANSI 15.1 language
25 (2)
The reactor shall not be operated whenever the reactor core is in the same end of the reactor pool as any portion of the cobalt-60 source.
(1) Experiments shall be designed such that a credible failure of the experiment shall not result in releases or exposures in excess of 10 CFR Part 20 limits.
(2) Experiments shall be designed such that a failure of an experiment shall not contribute to the failure of another experiment, core components, or principal physical barriers to uncontrolled release of radioactivity.
(3) All materials to be irradiated shall be either corrosion resistant or encapsulated within corrosion resistant containers to prevent interaction with reactor components, or pool water, or Co-60 sources. Corrosive materials shall be doubly encapsulated. Should a failure of the encapsulation occur that could damage the reactor or Co-60 sources, then the potentially damaged components shall be inspected.
(4) Explosive materials shall not be irradiated nor shall they be allowed to generate in any experiment in quantities over 25 milligrams of TNT-equivalent explosives. In addition, the irradiation container for this material shall be designed and tested for a pressure exceeding two times the maximum expected pressure. Explosive material such as (but not limited to) gunpowder, dynamite, TNT, nitroglycerine, or PETN in quantities <25 mg may be irradiated in the reactor or experimental facilities provided out core tests indicate that, with the containment provided, no damage to the explosive containers, the reactor or the reactor components or the Co-60 Source shall occur upon detonation of the explosive.
(5) Each fueled experiment shall be limited such that the total inventory of iodine-131 through iodine-135 in the experiment is not greater than 100 mCi.
Bases Specification 1 requires an evaluation to assure the experiment materials and apparatuses used in an experiment do not lead to airborne and/or area radiation exposures that could exceed 10 CFR Part 20 limits under credible failure conditions. Specification 2 requires an evaluation to assure materials and apparatuses used in experiments do cause a failure of other experiments, structures, systems, or components resulting in a radiological consequence.
Specification 3 provides assurance that no unintended chemical reaction will take place that could adversely affect structures, systems, or components resulting in a Comment [L50]: Moved to Core Config Comment [L51]: RAI 14.3.32 Comment [L52]: RAI 14.3.30 Comment [lb53]: See response RAI 14.3.31.
Similar to MURR, AFRRI Comment [lb54]: Less than 1/2 MHA
26 radiological consequence. Specification 4 provides assurance that the detonation of explosive materials will not lead to the failure of encapsulation and possible damage to the reactor, structures, systems, or components resulting in a radiological consequence. Specification 5 limits the inventory of iodine radioisotopes to approximately one-half that used in the maximum hypothetical accident (MHA) analysis in which the occupational and public dose consequences were determined to be well below 10CFR Part 20 regulatory limits.
3.8 Beamport Operations Applicability This specification applies to restrictions associated with operation of the beamports.
Objective To prevent a loss of coolant accident that may cause the safety limit to be exceeded.
Specifications:
- 1) The reactor shall not be operated with both the beam port lead shutter in the up (open) position and the beam-port shield plug removed.
- 2) The shield plug may be substituted or modified so long as the overall open diameter does not exceed an area equivalent to 4 inches in diameter.
- 3) In order to access the beam ports with both the lead shutter in the up position and shield plug removed, the reactor shall be positioned in the bulk pool.
Bases A conservative loss of coolant analysis involving a beam port rupture demonstrates the beam ports can be safely utilized under the provided specifications.
4.0 SURVEILLANCE REQUIREMENTS Applicability This specification applies to the surveillance requirements of systems related to reactor safety.
Objective To verify the proper operation of systems related to reactor safety.
Specification A. Surveillance requirements may be deferred during reactor shutdown (except TS 4.1(7);
Comment [lb55]: RAI 14.3.18 Comment [lb56]: Added per RAI 14.4.1&2
27 4.2.1(2); 4.3; and 4.6(2)); however, they shall be completed prior to reactor startup unless reactor operation is required for performance of the surveillance. Such surveillance shall be performed as soon as practical after reactor startup. Scheduled surveillance, which cannot be performed with the reactor operating, may be deferred until a planned reactor shutdown.
B. The appropriate surveillance testing on any Limiting Condition of Operation required equipment shall be conducted after replacement, repair, or modification before the equipment is considerable operable and returned to service Basis Specification 4A allows for the deferral of surveillances when the reactor is shut down provided they are performed prior to reactor operation or if operation is required to perform the surveillance, they are performed as soon as practical after reactor start up. This ensures that the requirements for limiting conditions of operation in accordance with section 3.0 are met.
Specification 4B ensures that the affected LCO required equipment will operate as intended and as described in the SAR.
4.1 REACTOR CORE PARAMETERS 4.1.1 Excess Reactivity and Shutdown Margin Applicability:
This specification applies to surveillance requirements for the various reactor core parameters.determining the reactor core excess reactivity and shutdown margin.
Objective:
To ensure that the reactor core parameters meet the specified limiting conditions for operation. excess reactivity and shutdown margin limits of the reactor are not exceeded.
Specification:
Excess reactivity and shutdown margin and shall be determined annually and prior to the routine operation of any new fuel configuration in the reactor core.
- 1. The reactor core excess reactivity above reference core condition shall be verified annually or following any significant core configuration and/or control blade change. A significant core configuration change is defined as a change in reactivity greater than 0.2 %k/k.
- 2. The shutdown margin shall be verified annually or following any significant core configuration and/or control blade change. A significant core configuration change is defined as a change in reactivity greater than 0.2
%k/k.
Comment [lb57]: Subheading not needed.
Comment [lb58]: Changes per RAI 14.4.3&4&5
28
- 3. Prior to the first reactor start-up of the day, visual verification shall be made that each core grid positions is filled with either a fuel element, a radiation basket, a source holder, the regulating rod, a graphite reflector element, a lead void box, or a grid plug.
- 4. Prior to the first reactor start-up of the day, visual verification shall be made that all but 5 of the radiation baskets contain flow restricting devices. This specification shall be optional for low power operation <100 kW without forced flow.
- 5. Prior to the first reactor start-up of the day, visual verification shall be made that the reactor is not in the same end of the reactor pool as any portion of the cobalt-60 source.
- 6. Prior to the first reactor start-up of the day, a visual verification shall be made confirming the beam ports meet the criteria of TS 3.8.
- 7. The linear and logarithmic power channels signals shall be checked against a heat balance annually.
- 8. Visual inspection of one-fifth of the in-core reactor fuel elements shall be performed every two years, such that all fuel elements in the core are inspected over a 10 year period.
Bases:
A determination of excess reactivity is needed to preclude operating without adequate shutdown margin. Configuration changes to the reference core described in Chapter 13 are governed by administrative controls to ensure configurations are maintained within the envelope of conditions used to establish the Safety Limit.
Specifications (1) through (4) provide verification the reactor is being operated within the nuclear and hydraulics design parameters used in the steady state and transient analyses. Specification (5) and (6) provide verification that the measured reactor power level is correct. Specification (7) provides verification of acceptable fuel condition.
4.1.2 Fuel Elements Applicability This specification applies to the surveillance requirements for the reactor fuel.
Objective To detect if there is any deterioration, corrosion, or other physical changes to the fuel elements that could lead to loss of cladding integrity.
Comment [lb59]: RAI 14.3.18(d). Placed here rather a separate surveillance spec section 4.8.
Comment [L60]: Moved to 4.1.8
29 Specification Visual inspection of one-fifth of the in-core reactor fuel elements shall be performed every two years.
Bases Fuel inspections at the UMLRR since 1974 have revealed no negative fuel conditions. The specification of quantity and frequency is considered adequate based upon MTR fuel history.
4.2 REACTOR CONTROL AND SAFETY SYSTEMS 4.2.1 Control BladesRods Applicability This specification applies to the surveillance requirements for operability of the reactor control bladesand regulating rods.
Objective To ensure the the control blades meet the specified limiting conditions of operation operability of the control and regulating rods.
Specification
- 1. Prior to the first reactor start-up of the day, all the control blades shall be verified as operable.
1.2.
The control blades shall be visually inspected annually.
(1)
The reactivity worth of the regulating rod and each control rod shall be determined annually.
(2)
The reactivity worth of all rods shall also be determined prior to routine operation of any new fuel configuration in the reactor core.
- 3. Control blade scram times rod drop and drive times, and regulating rod drive time shall be determined annually, or if maintenance or modification is performed on the mechanism.
The control and regulating rods shall be visually inspected annually.
Bases The operability checks, visual inspection of the control blades, and the Comment [L61]: Reactivity specs now part of 4.2.2 Comment [L62]: Not part of safety system
30 measurements of scram times ensure that the blades are capable of operating properly and within the considerations used in transient analyses in Chapter 13 of the SAR. Drive times are used for calculating reactivity addition rates.
Verification of operability after maintenance or modification of the drive mechanism will ensure proper operation after reinstallation or reconnection.
4.2.2 Rod Reactivity Insertion Rate Applicability This specification applies to the surveillance requirements for the reactivity insertion rates.
Objective To ensure the reactivity insertion rates do not exceed the limiting conditions for operation.
Specification
- 1. The reactivity worth and maximum reactivity insertion rate of the regulating rod and each control blade shall be determined annually or following any significant core configuration and/or change in a control blade or the regulating rod. A significant core configuration change is defined as a change in reactivity greater than 0.2 %k/k.
- 2. Prior to the first reactor start-up of the day, the control blade drive system shall be tested to verify only control blade can be withdrawn at a time.
Bases The reactivity worth of the control blades and regulating rods is measured to ensure that the required shutdown margin is available, and to provide a means for determining the reactivity worths of experiments inserted in the core. Annual measurement of reactivity worths provides a correction for the slight variations expected because of burnup, and the required measurement after a any new arrangement of fuel in the core configuration change ensures that possibly altered rod worths will be known before routine operation. The visual inspection of the regulating and control rods and the measurements of drive and drop times are made to ensure that the rods are capable of operating properly and within the considerations used in transient analyses in Chapter 13 of the SAR. Verification of operability after maintenance or modification of the control system will ensure proper reinstallation or reconnection.
4.2.32 Reactor ProtectionSafety System Scrams Applicability This specification applies to the surveillance requirements for the Reactor Protection Safety System.
Comment [L63]: RAI 14.4.6
31 Objective To ensure that the Reactor Protection Safety System limiting conditions for operation are met.channels will remain operable. and will prevent the Safety Limit from being exceeded.
Specification (1)
A channel check of each channel listed in Specification 3.2.5, specific to the operating mode, shall be performed daily when the reactor is in operation.
(2)
A channel test, including scram function where applicable, of each channel listed in Specification 3.2.5, specific to the operating mode, shall be performed prior to each day's operation, or prior to each operation extending more than one day.
(3)
A channel calibration of the reactor power level channels (Linear and Log-N), and the period channel shall be made annually.
(4)
Thermal power level shall be verified annually.
(5)
A channel calibration of the following channels shall be made annually:
- a. Pool water temperature
- b. Primary coolant flow rate
- c. Pool water level
- d. Primary coolant inlet and outlet temperature (6)
The manual scram in the control room shall be verified to be operable prior to each days operation, or prior to each operation extending more than one day.
(7)
All Manual scrams outside of the control room, all other limit switches in the scram chain including those listed in Specifications 3.2.3 items 8 - 15 and 3.2.4, and the controls displays watch dog timers shall be verified operable annually.
(7)
(8)
The radiation monitoring system scram shall be verified operable annually.
(9)
The interlocks listed in Specification 3.2.6 shall be verified operable annually.
Comment [L64]: Added per mtg 1/9/19 Comment [L65]: RAI 14.4.8 Comment [L66]: Inlet specified in SAR 13 analyses. Outlet not used in any analyses.
Comment [L67]: See RAI response 14.4.10 Comment [L68]: See RAI response 14.3.10 &
14.4.12
32 (10)
Any reactor protection system channel replaced or repaired shall be calibrated and undergo a channel test after installation and prior to reactor operation.
Bases The daily channel tests and checks and periodic verifications will ensure that channels used to measure the process variables are operable. Annual calibrations will ensure that any long term drift of the process measuring channels is corrected. Appropriate annual tests of other scrams channels in the scram chain and control system interlocks will ensure that those functions not tested before daily operation remainare operable.
4.3 COOLANT SYSTEMS Applicability This specification applies to verifying the quality of the primary coolant system water and the pool configuration the surveillance requirement of monitoring the quality and the radioactivity in the pool water.
Objective To ensure the primary coolant system limiting conditions for operation are met high quality pool water and to monitor the radioactivity in the pool water in order to verify the integrity of the fuel cladding and cobalt-60 sources.
Specification (1)
The conductivity and pH of the pool water shall be measured weeklyquarterly.
(2)
The pH of the pool water shall be measured quarterly.
(2)
The radioactivity in the pool water shall be analyzed monthly.
(3)
The pool water shall be either monitored continuously for Co-60 or sampled once per week.
(4)
Prior to the first reactor start-up of the day, the pool divider shall be verified as open.
Bases Surveillance of water conductivity ensures that changes that could accelerate corrosion have not occurred. The pH and conductivity reading are administratively recorded as part of the reactor checkout procedure. A minimum weekly measurement is consistent with the recommendations in ANSI/ANS 15.1.
Monthly radionuclide analysis of the pool water samples will allow early Comment [L69]: Moved to spec 4B Comment [L70]: See response RAI 14.4.5 Comment [L71]: In bases 3.3
33 determination of any significant buildup of radioactivity from operation of the reactor. or the cobalt-60 sources. Either continuous or weekly pool water sampling for determining if the Co-60 sources are leaking is consistent with the original technical specification for monitoring source leakage. Verifying the pool divider condition meets the requirements of TS 3.3(4).
4.4 CONFINEMENTTAINMENT Applicability This specification applies to the surveillance requirements for the reactor building confinement. containment building.
Objective To ensure that the confinement limiting conditions for operation are met.containment system is operable.
Specification
- 1. Prior to any of the operations specified in 3.4.1 the main intake fan shall be verified as operating.
- 2. Prior to any of the operations specified in 3.4.1 and at no less than 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> intervals during, the building pressure compared to ambient shall be verified at or more negative than 0.1 inch water column.
- 3. The confinement system shall be functionally tested semi-annually.
- 1.
Building pressure will be verified prior to reactor operation and at least every eight hours during reactor operation to ensure that it is less than ambient atmospheric pressure.
The containment building isolation system including the initiating system shall be tested annually. The test shall verify that valve closure is achieved in <2.5 seconds after the initial signal.
Any additions or modifications to the containment building or its penetrations shall be tested to verify containment building integrity by performing an integrated leakage rate test of the containment building.
Bases Maintaining a negative pressure ensures that any confinement building leakage is inward.
Maintaining a negative pressure ensures that any leakage into the containment building is inward. The valve closure time was chosen to be 1/2 the time required for a given sample of air to travel from the first to the second valve in series in the exhaust line under regular flow conditions. Based upon 40 years of data, annually provides a reasonable frequency of testing. The containment building was designed to withstand a 2.0 psig internal pressure (SAR Chapter 6). Given there is no credible accident (SAR Chapter 13) that would result in Comment [L72]: RAI response 14.4. 16, 17, 18
& 20
34 an overpressure of the building concurrent with a fission product release, performing an integrated leak rate test on a regular basis is unnecessary. In addition, the data for previous integrated leak tests performed over the past 40 years have shown the containment building integrity has always met the criteria specified in Chapter 6 of the SAR.
4.5 VENTILATION SYSTEMS Applicability This specification applies to the surveillance requirements for the confinement containment building emergency exhaustventilation system.
Objective To ensure that the ventilation emergency exhaust system is operable.operates as described in Chapter 6 of the SAR.
Specifications (1) The an operability check of the emergency exhaust system including the initiating system shall be performed verified quarterly annually to be operable or, following any maintenance or modifications that could affect the operability of the system.
(2)
The carbon filter trains in the emergency exhaust system, facilities exhaust, and pneumatic sample exhaust shall be replaced or tested biennially. to verify that they are operable.
(3)
The air flow rate in the stack exhaust duct shall be measured biennially.
Bases Surveillance of the emergency exhaust system and the periodic testing or replacement of the carbon various filters will verify the system is that these are functioning as described in Chapter 6 of the SAR. Experience over 40 years has shown that a biennial measurement of exhaust ventilation flow rate is sufficient to detect trends.
4.6 RADIATION MONITORING EQUIPMENT Applicability This specification applies to the surveillance requirements for the area radiation monitoring equipment and systems for monitoring airborne radioactivity.
Objective To ensure the radiation monitoring equipment limiting conditions for operation Comment [L73]: RAI 14.4.19 Comment [L74]: Only the emergency exhaust carbon filter is considered for the MHA in the SAR.
Comment [L75]: Original TS for containment.
Not required by ANSI/ANS 15.1
35 are met.that the equipment used for monitoring radiation and radioactivity is operable and measuring accurately.
Specification (1) A channel test of the radiation monitoring channels in Specification 3.6.1(.1) shall be made prior to each days operation.
(2) The radiation monitoring channels in the radiation monitoring system shall be calibrated and the trip setpoints verified when initially installed and annually thereafter.
Bases The channel tests verify the channel operability by the introduction of a test signal. The calibration provides a complete verification of the performance of the channel. The radiation monitoring system is described in Chapter 7 of the SAR.
The large number of detectors in the area radiation monitoring system ensures that if a particular monitor should malfunction or drift out of calibration, sufficient backup monitors are available for reliable information. Calibration of the area radiation monitors annually An annual calibration is based upon manufacturer recommendations and is sufficient to ensure the required reliability.
End Section 4 5.0 DESIGN FEATURES Applicability These specifications apply to the physical location of the reactor and supporting structures.
Objective To specify the bounds of the facility.
36 5.1 SITE AND FACILITY DESCRIPTION 5.1.1 Site Location The reactor and associated equipment shall be located is housed in the reactor building, designed for containment, at 1 University Avenue, Lowell, Massachusetts, located on the north campus of the University of Massachusetts at Lowell.
5.1.2 Facility Description The facility is the area under the reactor license. It shall includes the reactor building, designed for confinement, and the attached three story building. The reactor building shall beis the restricted area as defined in 10 CFR Part 20.
The reactor building shall havehas a minimum free volume of 335,000 ft3 that is exhausted through a 100 ft. high stack. The three story building attached to the reactor building shall include spaces necessary for supporting licensed activities including radiation protection, emergency preparedness, physical security, and the reactor building ventialtion.
Bases The site on which the reactor building is located is detailed in chapter 2 of the SAR. Chapters 3 and 6 provide details of the reactor building and its design features. The attached three story building includes spaces described in the radiation safety program (SER Chapter 11), in the Emergency Preparedness Plan, and in the Physical Security Plan.
5.2 REACTOR COOLANT SYSTEM Applicability:
These specifications apply to the reactor pool and primary coolant system.
Objective:
To specify the major design features of the reactor coolant system.
The reactor coolant system shall consists of the following:
(1) Aan open pool containing approximately 75,000 gallons of demineralized water (H2O).,
(2) Aa single cooling loop containing a heat exchanger, a circulation pump, and various valves.
(3) All materials associated with the reactor coolant system shall beare aluminum alloys, except for the stainless steel heat exchanger which may include stainless steel components, and small non-corrosive components such as gaskets, filters, and valve diaphragms.
Comment [lb76]: Changed to confinement Comment [lb77]: Removed irrelevant information Comment [lb78]: Change to allow flexibility in changes to heat exchanger
37 Bases Chapter 5 of the SAR provides detail on the reactor cooling system.
5.3 REACTOR CORE AND FUEL 5.3.(1). The reactor core shall consists of a 9 x 7 array of 3-inch square modules with the four corners occupied by posts. The reference core for these Technical Specifications is described in Chapter 4 of the SAR. It consists of 19 standard fuel elements and two half-elements and the central location filled with a flux trap element, as shown in Figure 4.2 of the SAR.
5.3.(2). Cores shall containfrom 210 elements to 26 elements may be used, consisting of the any combination of fuel elements as described in specifications 5.3.3, 5.3.4, and 5.3.5.
5.3.(3) A standard fuel element shall be either:
- a. A flat plate MTR-type element having plates fueled with low enrichment (<20% U-235) U3Si2, clad with aluminum. There shall be 18 plates per element with 16 plates containing fuel and two outside plates of aluminum. There shall be 200 +/- 2 grams of Uranium-235 per element when new, or
- b. A flat plate MTR-type element having plates fueled with low enrichment (<20% U-235) UAlx, clad with aluminum. There shall be 18 plates per element. There shall be 167 +/- 2 grams of Uranium-235 per element when new.
5.3.(4) A partial fuel element shall be the same as Specification 5.3.3.a except each plate shall have has approximately half the uranium loading. No more than two (2) partial fuel elements shall be allowed in the core.
5.3.(5) A removable plate fuel element shall be the same as Specification 5.3.3.b, except the fuel plates are removable. No more than one (1) removable plate element shall be allowed in the core.
(3)(6)
Prior to operating the reactor with a removable plate element, a safety analysis shall be performed for each core configuration and configuration of the element to assure there are no changes to the safety margins presented in the SAR. The analysis shall be reviewed and approved by the reactor safety subcommittee.
Comment [L79]: See response RAI 14.5.5 Comment [L80]: See response RAI 14.5.6 which includes additions to other specs below
38 (7) The average fission density shall not exceed 2 x 1021fissions/cm3.
Bases Chapter 4 of the SAR provides details of the core design which are included in the safety analyses. The analyses show the reactor can be safely operated with any combination of U3Si2 and UAlx fuel, including 2 partial U3Si2 elements, for core loadings from 21 to 26 elements. The removable plate element provides for numerous configurations of placement in the core and number of plates used, requiring each configuration to be separately analyzed before use. The negative reactivity coefficients are described in the SAR Chapter 4 and used in the transient analyses (SAR Chapter 13). NUREG-1313 provides data indicating fission densities up to 2.5 x 1021fissions/cm3 are acceptable.
5.4 FISSIONABLE MATERIAL STORAGE Fuel elements may be stored in any of the following locations:
(1)
Un-irradiated fuel may be stored in licensed shipping containers within the restricted area.
(2)(1) In the fuel storage racks located inside the reactor pool.
(3)
In licensed shipping containers located in the restricted area or an area designated as a controlled area.
(4)
In the reactor core provided the reactivity is below the shutdown margin given by Specification 3.1.2.
Applicability:
These specifications apply to the storage of reactor fuel when not in the core and the storage of other fissionable material.
Objective:
To ensure that stored fuel or other fissionable material does not become critical and will not reach an unsafe temperature.
(1) Fuel, including fueled experiments and fueled devices not in the reactor shall be stored in the restricted area and in a configuration that ensures adequate cooling and is designed to maintain keff less than 0.9 under all conditions of moderation and reflection.
(2) Where a licensed shipping container is used, the keff and cooling design considerations of the container shall apply.
Comment [L81]: See response RAI 14.5.9 Comment [lb82]: See response RAI 14.5.8
39 Bases Specification (1) assures criticality is not attained and temperatures do not reach a level where damage could occur. Specification (2) allows for shipments.
6.0 ADMINISTRATIVE CONTROLS 6.1 ORGANIZATION 6.1.1 Structure The University of Massachusetts Lowell Research Reactor (UMLRR) is an integral part of the Radiation Laboratory of the University of Massachusetts Lowell (UML). The organization for the management and operation of the research reactor facility in matters related to the license and these technical specifications shall be as is shown in Figure 6-1.
6.1.2 Responsibility
- 1.
Office of the Chancellor: The Chancellor shall designate an individual (Level 1), at a position of associate vice chancellor or higher, to be responsible for ensuring that all research, education, and service activities at the research reactor facility are conducted in accordance with applicable federal, state and local regulations.
1.2.
The Reactor Supervisor (Level 2) shall beis directly responsible for the safety of all operations at of the research reactor facility, and in all matters pertaining to these Technical Specifications.
2.3.
In all matters pertaining to safe operation of the reactor and to these Technical Specifications, the Reactor Supervisor shall report to and be directly responsible to the Director of the Radiation Laboratory (Level 21).
3.4.
The UML Radiation Safety Officer shall be responsible for radiation protection at the UMLRR and shall advise the Reactor Supervisor on all matters pertaining to radiation protection.
4.5.
In matters pertaining to radiation safety, theThe UML Radiation Safety Officer shall report to and be directly responsible to the Level 1 individual in the Office of the Chancellor. Director of UML Environmental and Emergency Management.
Comment [lb83]: Information not needed Comment [L84]: Chart revised per RAI 14.6.3 and mtg on 1/9/19.
Comment [L85]: RAI 14.6.3. Same wording as MURR Comment [lb86]: Consistent with Radiation Safety Charter.
40 Reporting Line Communication Line Figure 6-1
41 6.1.3 Staffing
- 1. The following shall be the minimum staffing when the reactor is not secured:
- a. A reactor operator or senior reactor operator shall be in the control room.
- b. A second designated person shall be present at the facilitysite. This individual shall be a senior reactor operator, reactor operator or an individual able to carry out prescribed written instructions.
Unexpected absence for as long as 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to accommodate a personal emergency may be acceptable provided immediate action is taken to obtain a replacement.
- c. If a senior reactor operator is not at the facilityon site, a senior reactor operator shall be readily available on call. Readily available on call shall means an individual who:
- 1. has been specifically designated and the designation known to the operator on duty,
- 2. keeps the operator on duty informed of where he/she may be Comment [lb87]: See response RAI 14.6.5
42 rapidly contacted and the phone number, and
- 3. is capable of getting to the reactor facility within a reasonable time under normal conditions (e.g., 30 minutes or within a 15-mile radius).
- 2. A list of reactor facility personnel by name and telephone number shall be readily available for use in the control room. The list shall include:
- a. Management personnel,
- b. Radiation safety personnel, and
- c. Other operations personnel 2.3.
The following events shall require the presence of a senior reactor operator at the facilitysite:
- a. Initial startup and approach to power for each days operation.
- b. All fuel or control-rod relocations within the reactor core region.
- c. Recovery from an unplanned or unscheduled shutdown or power reduction of 200kW or greaterfor which documented verbal concurrence from a senior reactor operator shall be made.
6.1.4 Selection and Training of Personnel
- 1.
The Director of the Radiation Laboratory shall be a tenured faculty member of the graduate faculty in a science or engineering discipline.
- 2.
The selection, training, and requalification of operations personnel shall meet or exceed the requirements (most current revision) of American National Standard, ANSI/ANS-15.4 Selection and Training of Personnel for Research Reactors. (R2007 or later revision).
6.2 REVIEW AND AUDIT There shall be a Reactor Safety Subcommittee (RSSC) which shall review reactor operations to ensure that the facility is operated in a manner consistent with public safety and within the terms of the facility license. The RSSC shall be a subcommittee of the University Radiation Safety Committee which has overall authority in the use of all radiation sources at the University.
6.2.1 Composition and Qualifications The RSSC shall be composed of at least five members, one of whom shall be the Radiation Safety Officer and another of whom shall be the Reactor Supervisor. Members of the RSSC shall be knowledgeable in the areas of reactor operation and radiation safety. The membership of the RSSC shall Comment [L88]: Added per RAI 14.6.4 Comment [lb89]: Wording not in ANSI 15.1 or 50.54m1 Comment [lb90]: Similar to MURR - 20%
43 include at least two faculty members from the engineering or science disciplines. Members shall be appointed by the Office of theuniversity Vice Provost for Research or Chancellor Level 1 designee. The RSSC chairman shall be elected from among the membership and shall not have line responsibility for operation of the reactor.
6.2.2 Charter and Rules The RSSC shall follow the rules specific to it under the charter and rules of the Radiation Safety Committee. Notwithstanding that charter and rules, the RSSC functions shall be conducted as follows:
- 1. Meetings shall be held at least once per calendar year and more frequently as circumstances warrant, consistent with effective monitoring of facility activities.
- 2. A meeting quorum shall consist of at least one-half of the membership where the reactor staff does not constitute a majority.
- 3. The RSSC may appoint a subgroup from within its membership to act on behalf of the full committee on those matters that cannot await the next meeting. The RSSC shall review the actions taken by the subcommittee at the next regular meeting.
4.3.
Meeting minutes shall be distributed to RSSC members within three months of the meeting. in a timely manner for review and approval at the next meeting.
6.2.3 Review Function
- 1. The RSSC shall review the following:
- a. Evaluations performed as required by 10 CFR 50.59 Determination that proposed changes in equipment, systems, tests, experiments, or procedures do not require a license update, as described in 10 CFR 50.59.
- b. All new procedures and major revisions thereto having safety significance and proposed changes in reactor facility equipment or systems having safety significance.
- c. All new experiments or classes of experiments that could affect reactivity or result in the release of radioactivity.
- d. Proposed changes in technical specifications or license.
Comment [L91]: See response RAI 14.6.6 Comment [L92]: See response RAI 14.6.7 Comment [L93]: See response RAI 14.6.8
44
- e. Violations of technical specifications or license and violations of internal procedures having safety significance.
- f. Operating abnormalities having safety significance.
- g. Reportable occurrences listed in specificationSection 6.6.2 of this document.
- h. Audit reports.
- 2. A written report or minutes of the findings and recommendations of the RSSC shall be submitted to the Level 1 individual in the Office of the Chancellor Director of the Radiation Laboratory and to the RSSC members within three months in a timely manner after a review has been completed.
6.2.4 Audit Function
- 1. The RSSC Aaudits of the following functions shallmay be performed by an individual or groupa member of the RSSC who without immediate responsiblity for the area being audited: does not have line responsibility for the reactor or by a consultant who is knowledgeable of reactor operations and radiation safety.
Audits shall be performed biennially.
- 2. The scope of the audit shall include, as a minimum, the following:
- a. Facility operations for conformance to the technical specifications and license conditions on an annual basis.
- b. The requalification program for the operating staff on a biennial basis.
- c. Corrective The results of actions associated with taken to correct those deficiencies that may occur in the reactor facility equipment, systems, structures, or methods of operation that affect reactor safety on an annual basis.
- d. The reactor facility emergency plan and implementing procedures on a biennial basis.
- 3. Deficiencies uncovered that affect reactor safety shall immediately be reported to the Chancellors Level 1 designee. Director of the Radiation Laboratory. A written report of the findings of the audit shall be submitted to the Chancellors Level 1 designee Director of the Radiation Laboratory and to all RSSC members within three months after the audit has been completed.
Comment [L94]: See RAI 14.6.9. Same wording as MIT Comment [L95]: Per RAI 14.6.10 Comment [lb96]: See response RAI 14.6.10 This wording similar to MURR - more clear
45 6.3 RADIATION SAFETY
- 1. The Radiation Safety Protection Program shall be designed to achieve the requirements of 10 CFR 20 and shouldshall use generally conform to the guidelines in (most current revision) American National Standard, ANSI/ANS-15.11 Radiation Protection at Research Reactor Facilities.
(R2009 or later revision).
- 2. The Radiation Safety Protection Program shall be the responsibility of the Radiation Safety Officer, having line authority as indicated in Figure 6-1.
2.3.
The Radiation Safety Program shall include management commitment to maintain exposures and releases as low as reasonably achievable.
6.4 OPERATING PROCEDURES 1 Written procedures, shall be reviewed by the RSSC and approved by the Reactor Supervisor (Level 2) or designee, and the RSSC shall be in effect and followed for the following items. The procedures shall be adequate to ensure the safe operation of the reactor and gamma irradiation facilities, but should not preclude the use of independent judgment and action should the situation require such.
- a. startup, operation, and shutdown of the reactor;
- b. fuel loading, unloading, and movement within the reactor;
- c. maintenance of major components of systems that could have an effect on reactor safety;
- d. surveillance checks, calibrations, and inspections required by the technical specifications or those that may have an effect on reactor safety; d.e. personnel radiation protection specific to the facility radiation monitoring system and the use of the reactor experimental facilities and the gamma irradiation facilities;
- f. administrative controls for operations and maintenance and for the conduct of irradiations and experiments that could affect reactor safety or core reactivity; e.g. for the conduct of irradiations and experiments in the gamma irradiation facilities f.h. implementation of required plans such as emergency or security plans;
- i. use, receipt, and transfer of byproduct material, if appropriate.
g.j.
2 Substantive changes to procedures shall be made with the approval of the Reactor Supervisor or designee, and the RSSC. Minor changes to procedures that do not change the original intent may be made by a senior reactor operator, but the change must be approved by the Reactor Supervisor or Comment [L97]: See response RAI 14.6.12.
Consistent with other approved TS.
Comment [L98]: See response RAI 14.6.15 Comment [L99]: See response RAI 14.6.13 & 14
& 15
46 designee. Temporary Ddeviations from procedures may be made by a senior reactor operator (Level 3) in order to deal with special or unusual circumstances or conditions. Such deviations shall be documented, reviewed pursuant 10 CFR 50.59, and reported within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or the next working day to the Reactor Supervisor or designee.
3 Written procedures for personnel radiation protection shall be reviewed and approved in accordance with the Radiation Protection Program (Specification 6.3). The procedures shall be consistent with the applicable regulations or guidelines. The radiation protection program and procedures shall include management commitment to maintain exposures and releases as low as reasonably achievable.
6.5 EXPERIMENTS REVIEW AND APPROVAL
- 1. All new experiments or class of experiments shall be reviewed by the RSSC, subject to the requirements of 10CFR 50.59, and approved in writing by the Reactor Supervisor or designated alternate prior to initiation.
- 2. Substantive changes to previously approved experiments shall be made only after review by the RSSC, subject to the requirements of 10CFR 50.59, and approved in writing by the Reactor Supervisor or designated alternate prior to initiation.
- 1. An experiment using the reactor shall not be conducted until a favorable evaluation indicated in writing is rendered by the RSSC. All proposed experiments using the reactor shall be documented and included a description and a safety evaluation prepared by either the experimenter or individual(s) appointed by the Reactor Supervisor.
The evaluation shall include:
- 2.
- 3. An estimated reactivity worth of the experiment;
- 4. The integrity of the experiment, including the effect of changes in temperature, pressure, chemical composition, or radiolytic decomposition;
- 5. Any physical or chemical interaction that could occur with the reactor components;
- 6. Any radiation hazard that may result from the activation of materials or from external beams; and
- 7. An estimate of the amount of radioactive materials produced.
- 8.
- 9. Prior to performing any new reactor experiment, an evaluation of the experiment shall be made by the RSSC and shall consider:
- 10.
- 11. The purpose of the experiment;
- 12. The effect of the experiment on reactor operation and the possibility and consequences of failure of some aspect of the experiment, including, where Comment [L100]: See RAI 14.6.16, 17, 18, & 19 regarding additions and deletions for this section.
6.5.1&2 use wording in ANSI/ANS 15.1 - 6.5.
47 significant, chemical reactions, physical integrity, design life, proper cooling interaction with core components, and reactivity effects;
- 13. Whether or not the experiment, by virtue of its nature and/or design, includes an un-reviewed safety question or constitutes a significant threat to the integrity of the core, the integrity of the reactor, or to the safety of personnel; and
- 14. A procedure for the performance of the experiment.
- 15.
- 16. An experiment that has had prior RSSC approval and has been performed safely shall be a routine experiment and requires only the approval of the Reactor Supervisor (or designee) and the Radiation Safety Officer (or designee) to be repeated. An experiment that represents a minor variation from a routine experiment, not involving safety considerations of a different kind, shall be considered the equivalent of a routine experiment and may be approved by agreement of the Reactor Supervisor (or designee) and the Radiation Safety Officer (or designee).
6.6 REQUIRED ACTIONS 6.6.1 Action To Be Taken In The Event The Safety Limit Is Exceeded
- 1. The reactor shall be shut down and reactor operation shall not be resumed until authorization is obtained from the NRC.
- 2. The safety limit violation shall be promptly reported to the Reactor Supervisor or his designee, the Chancellors Level 1 designeeDirector of the Radiation Laboratory, and the Chairman of the RSSC.
- 3. The safety limit violation shall be reported by telephone to the NRC within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The safety limit violation shall be reported to the NRC in accordance with specification 6.7.2.
- 4. A safety limit violation report shall be prepared. The report shall describe the following:
- a. The time and date of the violation, reactor status at the time of the violation, and a description of the violation.
- b. The applicable circumstances leading to the violation including, when known, the cause and contributing factors.
- c. The effect of the violation upon reactor facility components, systems, or structures and on the health and safety of personnel and the public.
- d. Corrective action to be taken to prevent recurrence.
- 5. The report shall be reviewed and approved by the RSSC and shall be submitted to the NRC in accordance with specification 6.7.2 of this document.within 14 working days, and any follow-up report shall be
48 submitted to the NRC when authorization is sought to resume operation of the reactor.
6.6.2 Action To Be Taken in the Event of a Reportable Occurrence
- 1. A reportable occurrence shall beis any of the following conditions:
- a. Release of radioactivity from the reactor confinementtainment building above allowed limits.
- b. Operating with any safety system setting less conservative than those stated in Section 2.2 these specifications.
- c. Operating in violation of a limiting condition for operation established in Section 3.0 of these specifications unless prompt remedial action is taken as specified in Section 3.
- d. A reactor safety system component malfunction during reactor operation that renders or could render the reactor safety system incapable of performing its intended safety function. If the malfunction or condition is caused by maintenance, then no report shall be required.
- e. An uncontrolled or unanticipated change increase in reactivity in excess of 0.678%k/k (one dollar). Reactor trips resulting from a known cause are excluded.
- f. An abnormal and significant degradation in reactor fuel and/or cladding, coolant boundary, or confinementtainment boundary (excluding minor leaks).
- g. An observed inadequacy in the implementation of either administrative or procedural controls, such that the inadequacy could have caused the existence or development of an unsafe condition in connection with the operation of the reactor.
- 2. In the event of a reportable occurrence, the following four actions shall be taken:
- a. If involving the reactor, tThe reactor conditions shall be returned to normal, or the reactor shall be shutdown, to correct the occurrence. If shutdown, the reactor shall not be operated until authorized by the Reactor Supervisor (Level 2).
a.b. If involving a gamma irradiation facility, the conditions shall be returned to normal, or gamma facilities operations shall cease, to correct the occurrence. If operations cease, the gamma irradiation facility shall not be operated until authorized by the Reactor Supervisor.
b.c. The Reactor Supervisor shall be notified as soon as possible.
and corrective action shall be taken before resuming the operation involved.
c.d. The Nuclear Regulatory Commission shall be notified in Comment [L101]: See RAI 14.6.22, 23, 24, & 25 regarding additions and deletions for this section.
Comment [L102]: RAI 14.6.25 Comment [L103]: Added per RAI 14.6.25 and mtg 1/9/19
49 accordance with specification 6.7.2.
d.e. A report shall be prepared that includes the time and date of the occurrence, facilityreactor status at the time of the occurrence, a description of the occurrence, an evaluation of the cause of the occurrence, a record of the corrective action taken, and recommendations for appropriate action to prevent or reduce the probability of recurrence. This report shall be submitted to the U. S. Nuclear Regulatory Commission and it will be reviewed by the RSSC no later than its next regularly scheduled meeting.
6.7 REPORTS 6.7.1 Operating Reports An annual or operating report shall be submitted to the NRC U.S. Nuclear Regulatory Commission Document Control Desk within ninety days following the 30th of June of each year. Its content shall include:
- 1.
A narrative summary of reactor operating experience including a tabulation showing the energy generated by the reactor (in megawatt days), the number of hours the reactor was critical, and the cumulative total energy output since initial criticality.
- 2.
The number of emergency shutdowns and inadvertent scrams, including the reasons therefore, and where applicable, corrective actions to preclude recurrence.
- 3.
Tabulation of major preventive and corrective maintenance operations having safety significance.
- 4.
A summary of the safety analyses performed in connection with changes to the facility or procedures, which affect reactor safety, and performance of tests or experiments carried out under the requirements of 10 CFR 50.59. A tabulation of changes in the facility and procedures and of tests and experiments carried out pursuant to 10 CFR 50.59.
5.4.
A summary of the nature and amount of radioactive effluents released or discharged to environs beyond the effective control of the licenseeowner or operator, or both, as determined at, or before, the point of such release or discharge. The summary shall include to the extent practicable an estimate of individual radionuclides present in the effluent. If the estimated average release after dilution or diffusion is <25% of the 10 CFR 20 Appendix Bregulatory concentration limits allowed or recommended, a statement to this effect is sufficient.
6.5. A summarized result of environmental surveys performed outside the facility.
7.6. A summary of exposures received by facility personnel and visitors Comment [L104]: See response RAI 14.6.27 Comment [L105]: See response RAI 14.6.28 Comment [L106]: See response RAI 14.6.29
50 where such exposures are ><25% of the regulatory limits in 10 CFR 20that allowed or recommended.
6.7.2 Special Reports
- 1.
A report shall be made not later than the following working day by telephone and confirmed in writing by fax or similar conveyance to the NRC Headquarters Operation Center, and followed by a written report that describes the circumstances of the event and sent within 14 days to the U.S. Nuclear Regulatory Commission, Attn: Document Control Desk, Washington, DC 20555, of any of the following:by telephone or other communication systems to the U.S. Nuclear Regulatory Commission Headquarters Operations Center within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of:
- a. Operation in violation of a safety limit.
- b. Any release of radioactivity to unrestricted areas above permissible limits., whether or not the release resulted in property damage, personal injury, or exposure.
- c. Any reportable occurrence as defined in Specification 6.6.2.
- 2.
A written report shall be provided as a follow-up to the verbal one within 14 days of the occurrence. This report shall provide the information required by Specification 6.6.2(2). The report shall be submitted to the NRC Document Control Desk.
- 3.
A written report shall be submitted within 30 days to the NRC Document Control Desk in the event of:
- a. A permanent change in the personnel serving as the Level 1Director of the Radiation Laboratory or Level 2Reactor Supervisor.
6.8 RECORDS 6.8.1 Five-Year Record Retention The following records shall be retained for five years or for the life of the component involved if less than five years:
- 1. Records of normal reactor operation including power levels and periods of operation at each power level. (Note: Excludes retention of supporting documents such as checklists, log sheets, etc., which shall be retained for a period of at least one year.)
- 2. Records of principal maintenance activities including inspection, repair, Comment [L107]: See response RAI 14.6.20 (also part b below)
Comment [lb108]: Consistent with ANS15.1
51 substitution, or replacement of principal items of equipment pertaining to nuclear safety.
- 3. Records of reportable occurrences.
- 4. Records of surveillance activities that are required by these technical specifications.
- 5. Records of reactor facility radiation and contamination surveys.
- 6. Records of experiments performed with the reactor.
- 7. Records of fuel inventories, receipt, and shipments.
- 8. Records of changes made in the operating procedures.
- 9. Minutes of the RSSC and audit reports including both internal audits and those performed for or by the RSSC.
6.8.2 Six-Year Record Retention Records of individual licensed staff members indicating qualifications, experience, training, and requalification shall be retained at all times that the individual is employed or until the operator license is renewed.
6.8.3 Records To Be Retained for the Life of the Facility Applicable annual reports, if they contain all of the required information, may be used as records in this section.
- 1. Gaseous and liquid radioactive effluents released to the environs.
- 2. Off-site environmental-monitoring surveys required by the technical specifications.
- 3. Radiation exposure for all personnel monitored.
- 4. Drawings of the reactor facility.
- 5. Applicable annual reports, if they contain all of the required information, may be used as records in this section. Reviews and reports pertaining to a violation of a safety limit, limiting safety system setting, or limiting conditions for operations.
End Section 6 Comment [L109]: See response RAI 14.6.30&31