ML18285A377

From kanterella
Jump to navigation Jump to search
Export License Issued to Source Production and Equipment Co., Inc. PXB14b.07
ML18285A377
Person / Time
Site: 11006034
Issue date: 10/11/2018
From: David Skeen
NRC/OIP
To: Bonds K
Source Production & Equipment Co
Savoy J
References
PXB14b.06
Download: ML18285A377 (3)


Text

EXPORT LICENSE NRC FORM 250 (10-07)

UNITED STA TES OF AMERICA Nuclear Regulatory Commission Washington, D.C. 20555 NRC LICENSE NO.:

PXB14b.07 Page 1 of 3 NRC DOCKET NO.:

11006034 LICENSE EXPIRES:

September 30, 2021 Pursuant to the Atomic Energy Act of 1954, as amended, and the regulations issued by the Nuclear Regulatory Commission (NRC) pursuant thereto, and in reliance on statements and representations heretofore made by the applicant/licensee, this license is hereby issued authorizing the licensee to export the byproduct materials listed below, subject to the terms and conditions herein. This license is only valid if the licensee or 'Other Party(ies) to Export' maintain the requisite NRC or Agreement State domestic license(s).

LICENSEE ULTIMATE CONSIGNEE(S) IN FOREIGN COUNTRY(IES)

Source Production & Equipment Co., Inc.

113 Teal St.

St. Rose, LA 70087 Attn: Kristen Bonds INTERMEDIATE CONSIGNEE(S) IN FOREIGN COUNTRY(IES)

None APPLICANT'S REFERENCE NO.: PXB14b 06 See Country(ies) of Ultimate Destination OTHER U.S. PARTY(IES) TO EXPORT None ULTIMATE DESTINATION: See countries listed on page 2 CONDITIONS, NOTES, AND DESCRIPTIONS OF 10 CFR PART 110, APPENDIX P, RADIOACTIVE MATERIALS TO BE EXPORTED (NOTE: SEE PAGE 3 FOR DEFINITIONS OF CATEGORY 1 AND CATEGORY 2)

Export to countries listed as 'Country(ies) of Ultimate Destination,' Category 2 quantities of Co-60, lr-192, Se-75, and Yb-169, contained in special forms or sealed sources for use in the manufacture or use of industrial gamma radiography and brachytherapy sources is authorized.

Licensee is responsible for compliance with all applicable import, export, and other domestic regulatory requirements, including all terms and conditions of domestic material possession licenses. Licensee, if not already submitted with your application, must submit information required by 10 CFR §110.32(d) and pertinent documentation required by 10 CFR

§110.32(9) at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to shipment. See page 3 for Mandatory Advanced Notifications.

License expiration date is based on established limits. This license replaces PXB14b.06 and amends its authority by extending the expiration date from September 30, 2018 to September 30, 2021 ; and updating the licensee point of contact.

Neither this license nor any right under this license shall be assigned or otherwise transferred in violation of the provisions of the Atomic Energy Act of 1954, as amended.

This license is subject to the right of recapture or control by Section 108 of the Atomic Energy Act of 1954, as amended, and to all of the other provisions of said Acts, now or hereafter in effect and to all valid rules and regulations of the NRC.

BY AUTHORIZE N C RErRj SE, TATl~E j)

THIS LICENSE l~SNV UNLESS SIGNED BELOW SIGNATURE:

'//-r'~~

NAME AND TITLE:

DATE OF ISSUANCE:

David L. Skeen, Deputy Director Office of International Programs OCT 11 2018 EXPORT LICENSE

COUNTRIES OF ULTIMATE DESTINATION(S):

PXB14b.07 Page 2 of 3 Albania, Algeria, Antigua and Barbuda, Armenia, Aruba, Azerbaijan, Bahamas, Bahrain, Barbados, Belize, Benin, Bhutan, Bosnia and Herzegovina, Botswana, Brunei, Burkina Faso, Burundi, Cambodia, Cameroon, Cape Verde, Central African Republic, Chad, Colombia, Comoros, Congo (Brazzaville), Congo (Kinshasa),

Costa Rica, Cote d'Ivoire, Croatia, Curacao, Dominica, Dominican Republic, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Fiji, Gabon, Gambia, Georgia, Ghana, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Holy See, Honduras, India, Indonesia, Jamaica, Jordan, Kenya, Kiribati, Kosovo, Kuwait, Kyrgyzstan, Laos, Lebanon, Lesotho, Liberia, Liechtenstein, Macau, Macedonia, Madagascar, Malaysia, Malawi, Maldives, Mali, Malta, Marshall Islands, Mauritania, Mauritius, Federated States of Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Nauru, Nepal, Nicaragua, Niger, Nigeria, Oman, Pakistan, Palestinian Territories, Palau, Panama, Papua New Guinea, Paraguay, Peru, Rwanda, Saint Kitts and Nevis, Saint Lucia, Saint Vincent and The Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Solomon Islands, Somalia, Sri Lanka, St. Maarten, Suriname, Swaziland, Tajikistan, Tanzania, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkmenistan, Tuvalu, Uganda, Uruguay, Uzbekistan, Vanuatu, Venezuela, Zambia, and Zimbabwe.

PXB14b.07 Page 3 of 3 MANDATORY ADVANCED NOTIFICATIONS PER 10 CFR PART 110.50(c)

The following Advanced Notifications must be made to both the NRC and, in case of exports, the government of the importing country in advance of each shipment:

Advanced Notifications to the NRC are to be emailed to hoo.hoc@nrc.gov (preferred method) or faxed to the NRC at 301-816-5151. In the subject line of the email or on the fax cover page include: "10 CFR 110.50(c) Notification."

For technical assistance, use the same e-mail address or call 301-816-5100.

Advanced Notifications to the government of the importing country must be emailed or faxed to the appropriate foreign government authorities. To locate the point-of-contact for international Prior Shipment Notifications see:

http://www-ns.iaea.org/downloads/rw/imp-export/import-export-contact-points.pdf. In the subject line of the email or on the fax cover page include: "NOTIFICATION TO THE IMPORTING STATE PRIOR TO SHIPMENT OF CATEGORY 1 OR 2 RADIOACTIVE SOURCES." For technical assistance or for countries not listed, contact the Office of International Programs' export/import staff at 301-287-9056.

Table 1: Appendix P to Part 110 Category 1 and Category 2 Radioactive Material Threshold Limits Radioactive Category 1 Category 2 Material Terabequerels (TBq)

Curies (Ci)'

Terabequerels (TBq)

Curles(Ci)1 Americium-241 (Am-241) 60 1,600 0.6 16 Americium-241/Beryllium (Am-60 1,600 0.6 16 241/Be)

Californium-252 (Cf-252) 20 540 0.2 5.4 Curium-244 (Cm-244) 50 1,400 0.5 14 Cobalt-60 (Co-60) 30 810 0.3 8.1 Cesium-137 (Cs-137) 100 2,700 1.0 27 Gadolinium-153 (Gd-153) 1,000 27,000 10.0 270 lridium-192 (lr-192) 80 2,200 0.8 22 Plutonium-2382 (Pu-238) 60 1,600 0.6 16 Plutonium-239/Bervllium2 (Pu-239/Be 60 1,600 0.6 16 Promethium-147 /Pm-147) 40,000 1,100,000 400 11,000 Radium-2263 (Ra-226) 40 1,100 0.4 11 Selenium-75 (Se-75) 200 5,400 2.0 54 Strontium-90 (Y-90) 1,000 27,000 10.0 270 Thulium-170 (Tm-170) 20,000 540,000 200 5,400 Ytterbium-169 /Yb-169) 300 8,100 3.0 81 Calculation of Shipments Containing Multiple Sources or Radionuclides:

The "sum of fractions" methodology for evaluating combinations of radionuclides being transported is to be used when import or export shipments contain multiple sources or multiple radionuclides. The threshold limit values used in a sum of the fractions calculation must be the metric values (i.e., TBq).

I. If multiple sources and/or multiple radionuclides are present in an import or export shipment, the sum of the fractions of the activity of each radionuclide must be determined to verify the shipment is less than the Category 1 or 2 limits of Table 1, as appropriate. If the calculated sum of the fractions ratio, using the following equation, is greater than or equal to 1.0, then the import or export shipment exceeds the threshold limits of Table 1 and the applicable security provisions of this part apply.

II. Use the equation below to calculate the sum of the fractions ratio by inserting the actual activity of the applicable radionuclides or of the individual sources (of the same radionuclides) in the numerator of the equation and the corresponding threshold activity limit from the Table 1 in the denominator of the equation. Ensure the numerator and denominator values are in the same units and all calculations must be performed using the TBq (i.e., metric) values of Table 1.

R1 = activity for radionuclides or source number 1 R2 = activity for radionuclides or source number 2 RN = activity for radionuclides or source number n AR1 = activity limit for radionuclides or source number 1 AR2 = activity limit for radionuclides or source number 2 ARN = activity limit for radionuclides or source number n n

[

R 1 R2 Rn J 2: --+--+--

~ 1 J

AR1 AR2 ARn 1 The values to be used to determine whether a license is required are given in TBq. Curie (Ci) values are provided for practical usefulness only and are rounded after conversion.

2 The limits for exports of Pu-238 and Pu-239/Be can be found in § 110.21.

3 Discrete sources of Radium-226.