ML18283A082

From kanterella
Jump to navigation Jump to search

Supplemental Information Related to License Renewal Application NRC Request for Additional Information to Clarify Response to RAI 2.3.3.16-1 Set 11
ML18283A082
Person / Time
Site: River Bend 
Issue date: 10/09/2018
From: Maguire W
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RGB-47904
Download: ML18283A082 (8)


Text

w-==", Entergx RGB-47904 October 9, 2018 Attn: Document Control Desk U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2738 Entergy Operations, Inc.

River Bend Station 5485 U.S. Highway 61 N St. Francisville. LA 70775 Tel 225*381*4177 William F. Maguire Site Vice President River Bend Station

Subject:

Supplemental Information Related to License Renewal Application NRC Request for Additional Information to Clarify Response to RAI 2.3.3.16-1 Set 11 River Bend Station, Unit 1 Docket No. 50-458 License No. NPF-47

References:

1) Entergy Letter: License Renewal Application (RBG-47735 dated May 25, 2017)
2) Entergy Letter: Response to License Renewal Application NRC Request for Additional Information (RAI) Set 11 (ML18073A068)

Dear Sir or Madam:

In Reference 1, Entergy Operations, Inc. (Entergy) submitted an application for renewal of the operating license for River Bend Station (RBS) for an additional 20 years beyond the current expiration date.

The license renewal subcommittee of the Advisory Committee on Reactor Safeguards (ACRS) met on September 20, 2018, to review the license renewal application and the associated safety evaluation report for River Bend Station (RBS). During the meeting, the subcommittee raised a question regarding the RBS response to RAI 2.3.3.16-1 (Reference 2) concerning crankcase vent piping for the emergency diesel generators. Enclosure 1 provides supplemental information to clarify the response to RAI 2.3.3.16-1 and replaces the original in its entirety.

In accordance with 10 CFR 50.91 (b)(1), Entergy is notifying the State of Louisiana and the State of Texas by transmitting a copy of this letter to the designated State Official.

If you require additional information, please contact Mr. Tim Schenk at (225)-381 -4177 or tschenk@entergy.com.

I declare under penalty of perjury that the foregoing is true and correct.

No new commitments have been identified in this letter.

RBG-47904 Page 2 of 2 Sincerely, WFM/djp : Supplemental Response to RAI 2.3.3.16-1 Set 11 cc:

U. S. Nuclear Regulatory Commission Attn: Emmanuel Sayoc 11555 Rockville Pike Rockville, MO 20852 U. S. Nuclear Regulatory Commission Region IV 1600 E. Lamar Blvd.

Arlington, TX 76011-4511 U. S. Nuclear Regulatory Commission Attn: Ms. Lisa M. Regner, Project Manager 09-0-14 One White Flint North 11555 Rockville Pike Rockville, MO 20852 NRC Senior Resident Inspector Attn: Mr. Jeff Sowa 5485 U.S. Highway 61, Ste. NRC St. Francisville, LA 70775 RBF1 0183

RBG-47904 Response to Request for Additional Information Set 11 Supplement

RBG-47904 Page 2 of3 REQUEST FOR ADDITIONAL INFORMATION LICENSE RENEWAL APPLICATION RIVER BEND STATION, UNIT 1 - Supplemental Response Set 11 DOCKET NO.: 50-458 CAC NO.: MF9757 Office of Nuclear Reactor Regulation Division of Materials and License Renewal The license renewal subcommittee of the Advisory Committee on Reactor Safeguards (ACRS) met on September 20, 2018, to review the license renewal application for River 8end Station (R8S). During the meeting, the subcommittee raised a question regarding the R8S response to RAI 2.3.3.16-1 concerning crankcase vent piping for the emergency diesel generators. The following supplemental response is provided to clarify the response to RAI 2.3.3.16-1. The response replaces the original response in its entirety.

Question RAI 2.3.3.16-1 (Plant Drains) 8ackground The staff performed its scoping and screening review of LRA Section 2.3.3.16 "Plant Drains."

Many of the components of the Plant Drains System (DER/DFRIVTP) are typically within the scope of components that require an AMR because they provide an intended pressure-retaining boundary function for the system.

After review of:

LRA Table 2.3.3-16; the nine (9) LRA drawings identified in LRA Section 2.3.3.16; and drawings LRA-PID-08-09A, LRA-PID-08-98 and LRA-PID-08-09D the staff requests additional information about a system Component Type that appears on one of these drawings. The staff notes that drawing LRA-PID-08-98 showing the subject vent lines of this "Issue" is referenced as part of LRA Section 2.3.3.18, Auxiliary Systems in Scope for 10 CFR 54.4(a)(2), which Section 2.3.3.16 refers to for certain reviews.

Issue LRA Drawing LRA-PID-08-98 identifies two vent pipes each from each Standby Diesel Generator EGS*EG 1 A(AR) [Coordinate M-2] and EGS*EG 18(88) [Coordinate E-2]. The two vent pipes for each diesel generator are identified as not being subject to AMR. Respectively, the vent pipes are identified as VTP-004-4-4 and VTP-004-5-4 for EGS*EG1A(AR) and as VTP-004-6-4 and VTP-004-7-4 for EGS*EG1 8(88). LRA Section 2.3.3.16 reads in part:

... The equipment vent system (VTP) provides vents to atmosphere, outside the buildings, for tanks associated with generator hydrogen system or to vent the combustion fumes from the diesel generator crankcase and lube oil tank....

From the staff's review of System Design Criteria (SOC) 309 (DIV I & II), SOC 309/405 (DIV III) and LRA Section 2.3.3.16, it is not clear how the function of venting the crankcase for the Division I & II EDGs and the HPCS Diesel Generator will be maintained during the period of extended plant operations.

RBG-47904 Page 3 of3 Request Please identify where the LRA addresses these ventilation piping components in LRA Table 3.3.2-16 "Plant Drains Summary of Aging Management Evaluation" or provide the staff with justification why these piping components are not addressed within LRA Table 3.3.2-16.

Response

The four lines shown on LRA Drawing LRA-PID-08-9B are vent pipes for the Division I and II diesel generator engines. The Division I and II diesel generator vent pipes are not addressed within LRA Table 3.3.2-16 because they do not have a license renewal intended function. The purpose of the vent pipe is to vent the gasses from the diesel generator to the outdoors. Upon loss of the vent pipe pressure boundary, the gasses would exhaust into the room, but the diesel would continue to perform its function. When the diesel is in operation, the room ventilation system is in service, venting the room. Therefore, the loss of pressure boundary of this pipe has no impact on the diesel or personnel and it has no safety function. The function of venting the crankcase to the outdoors is not necessary for the diesel to operate under emergency conditions. Periodic surveillance testing confirms adequate crankcase venting for both Division I and II and Division III diesel engines.

The nonsafety-related Division I and II diesel engine vent lines are not subject to aging management review under S4.4(a)(2) criteria due to leakage or spray because the vent lines contain no liquids that would impact other components in the room. The vent lines are installed with seismic supports that are subject to aging management review and included in the Structures Monitoring Program. Therefore, the vent lines cannot fall and impose an unanalyzed load on the connection to the safety-related diesel engine that would render it unable to perform its intended function under both normal operation and seismic CLB design conditions.

The Division III diesel generator engine is shown on LRA drawing LRA-PID-08-09D. This diesel engine does not have a vent line to the outdoors corresponding to that of the Division I and II diesel generators. The Division III diesel generator vents the crankcase to the outdoors via the engine exhaust line.

ATTACHMENT 9.4 Sheet 1 of 2 NRC SUBMITTAL REVIEW

{Typical}

Letter #: RBG-47904

Subject:

Additional Information to Clarify Response to RAI 2.3.3.16-1 Set 11 Response Due: 10/10/2018 Date Issued for Review: 10/8/2018 Correspondence Pre parer I Phone #: Pereira 1 4621 Section I Letter Concurrence and A reement to Perform Actions POSITION I NAME Bill Maguire Jeff Reynolds Tim Schenk Action concurrence, certification, etc.

Signature Review Review COMMENTS S

f II eClon C

d orrespon ence S creenmg Does this letter contain commitments? If "yes," identify the commitments with due Yes 0

dates in the submittal and in Section III. When fleet letters contain commitments, a No

~

PCRS LO (e.g., LO-LAR, LO-WT) should be initiated with a CA assigned to each applicable site to enter the commitments into the site's commitment management system.

Does this letter contain any information or analyses of new safety issues performed at Yes 0

NRC request or to satisfy a regulatory requirement? If "yes," reflect requirement to No

~

update the UFSAR in Section III.

Does this letter require any document changes (e.g., procedures, DBDs, UFSAR, TS Yes 0

Bases, etc.), if approved? If "yes," indicate in Section III an action for the responsible No

~

department to determine the affected documents. (The Correspondence Preparer may indicate the specific documents requiring revision, if known or may initiate an action for review.)

Does this letter contain information certified accurate? If "yes," identify the information Yes 0

and document certification in an attachment. (Attachment 9.5 must be used.)

No

~

ATTACHMENT 9.4 Sheet 2 of 2 Section III Required Actions Note: Actions needed upon approval should be captured in the appropriate action tracking system Commitments Note: When fleet letters contain commitments, a PCRS LO should be initiated with a CA assigned to each applicable site to enter the commitments into the site's commitment management system.

NRC SUBMITTAL REVIEW Actions and Commitments Due Date Responsible Dept.

N/A N/A Due Date Responsible Dept.

N/A N/A Section IV fltna Document Sicmoff for Submittal Correspondence Preparer Dennis Pereira ~~-J ~'

Final Submittal Review (optional)

Responsible Department Head

NUCLEAR QUALITY RELATED EN-LI-10S I REV. 17

~Entergy MANAGEMENT MANUAL INFORMATlONAL USE PAGE 1 OF 1 NRC Correspondence ATTACHMENT 9.5 CERTIFICATION REFERENCE FORM Letter Number: I RGB-47904

~--------------------------------------------------~

Subject:

I Supplemental Response for RAI2.3.3.1S-1 (EDG Vents)

Certifiable Statement(s): Use one of the following methods to identify certifiable statements In the table below:

1 Identify location in submittal (e.g., page 3, para 2, sentence 1) OR, 2

Paste In the exact words of the statement(s} OR, 3

State "see attachment" and attach a copy of the correspondence with the certifiable statements indicated (e.g., by redlining, highlighting, or underlining, etc.).

Each statement or section of information being certified should be uniquely numbered to correspond with the supporting documentation listed below.

Objective Evidence or Basis of Peer Review: Ust the supporting documents in the table below and attach a copy of the documents OR give basis of peer review. Large documents need not be attached.

Certifiable Statement(s)

Objective Evidence or Basis of Peer Review LRA-PID-08-09B LRA-PID-08-09D Drawing EP-S8C-2, Standby Diesel Generator BLDG Equipment Vents

1.

Attached Response to RAI 2.3.3.16-1 LDT-VTP -Equipment Vent Une List 9/13/18 Email from Kenneth Klamert Seismic calculations AX-S8A, Band C STP-309-0201, 0202, and 0203 SDC-309/40S for HPCS DG Individual certifying the atatement(s): Certification may be documented using e-mail, telecom, "sign off" sheet, or inter-oHice memorandum. The fonn of documentation should specifically identify the information being Certifie~d Stan Batchl ~

License Renewal f/r.56" Na e Department Date Peer Review: Prior to signing for certification, determine if a Peer Review is required per section S.4[2](c}.

Indicate "N/A" if not required.

AL1.Stttt ~tOut.Yl~~ ~


"JEJV~~h""U->oI=.!E...

~oa.::~:III:":="'>b.

N6me Department lu, ~f£ l E" Date EN-LJ-106 REV 17

',~

1

" ~

'. '.*,1 ill..

.~

.~.

.~.

r:'

~ '"'

,'~.

-~ ~.