ML18207A590
| ML18207A590 | |
| Person / Time | |
|---|---|
| Site: | Callaway |
| Issue date: | 06/19/2018 |
| From: | Ameren Missouri, Union Electric Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML18207A460 | List:
|
| References | |
| ULNRC-06442 | |
| Download: ML18207A590 (15) | |
Text
{{#Wiki_filter:SEE NOTE 1 REACTOR VESSEL HEAD t TO CONTAINMENT t NOTES:
- 1.
EXISTING VENT LINE CALLAWAY PLANT FIGURE 18.2-1 REACTOR HEAD VENT SYSTEM REV. 15 5/15 J
FSAR Figure 18.2-2 is withheld per RIS 2015-17 FSAR Figure 18.2-2 is withheld per RIS 2015-17 CALLAWAY PLANT FIGURE 18.2-2 REVOL-8 11/95 POST-ACCIDENT RADIATION ZONES ELEVATION 1974'
CALLAWAY PLANT Rev. OL-0 6/86 FIGURE 18.2-3 POST-ACCIDENT RADIATION ZONES ELEVATION 1988' FSAR Figure 18.2-3 is withheld per RIS 2015-17 FSAR Figure 18.2-3 is withheld per RIS 2015-17
CALLAWAY PLANT REV OL-11 5/00 FIGURE 18.2-4 POST-ACCIDENT RADIATION ZONES ELEVATION 2000' FSAR Figure 18.2-4 is withheld per RIS 2015-17 FSAR Figure 18.2-4 is withheld per RIS 2015-17
FSAR Figure 18.2-5 is withheld perRIS 2015-17 FSAR Figure 18.2-5 is withheld perRIS 2015-17 CALLAWAY PLANT Rev. OL-0 6/86 FIGURE 18.2.0 POST-ACCIDENT RADIATION ZONES ELEVATION 2026'
FSAR Figure 18.2-6 is withheld per RIS 2015-17 FSAR Figure 18.2-6 is withheld per RIS 2015-17 CALLAWAY PLANT FIGURE 18.2*6 REV. OL-10 11/98 POST-ACCIDENT RADIATION ZONES ELEVATION 2047'-6"
FSAR Figure 18.2-7 is withheld per RIS 2015-17 FSAR Figure 18.2-7 is withheld per RIS 2015-17 REVOL-12 11/01 CALLAWAY PLANT FIGURE 18.2-7 POST-ACCIDENT RADIATION ZONFS CONTROLBLIXi.& COMMUNICATION CORRIDOR ELEVATIONS 1974' & 1984'
FSAR Figure 18.2-8 is withheld per RIS 2015-17 CALLAWAY PLANT Rev. Ol-0 6/86 FIGURE 18.2-8 POST-ACCIDENT RADIATION ZONES CONTROL & DIESEL GENERATOR BUILDINGS AND COMMUNICATION CORRIDOR ELEVATIONS 2000' & 2016' FSAR Figure 18.2-8 is withheld per RIS 2015-17
w I- <( a: w (f) 0 0 10°r----------------.-----------------r----------------.---------------~~--------------~ 0 II 1 a*2 w ~ i= I- <( w I- ~ 10"3 w (f) 0 0 1o* 6 L---------------~-----------------L----------------i---------------~-----------------J 10*1 TIME (HOURS) CALLAWAY PLANT 104 Rev. OL-0 6/86 FIGURE 18.2-10 NORMALIZED DOSE RATE DECAY CURVE FOR AIRBORNE SOURCE (SOURCE A)
UJ f- <( a: UJ (/) 0 Cl 0 i= <( a: 10°------------------~----------------~-----------------.-----------------.-----------------, 0 II UJ ~ 10-1 f- <( UJ () a: 0 (/) (/) () f-z 10-2 UJ () a: UJ a.. UJ a: UJ (/) 0 10-3 Cl 10* 4 ~----------------~----------------~-----------------L----------------~----------------~ 10-1 LEGEND: 1 PERCENT Cs SOURCE -- --50 PERCENT Cs SOURCE TIME (HOURS) CALLAWAY PLANT 104 Rev. Ol-0 6/86 FIGURE 18.2-11 NORMALIZED DOSE RATE DECAY CURVES FOR SUMP SOURCE (SOURCE C) WITH 1 PERCENT Cs AND 50 PERCENT Cs
REFERENCE TIC JUNCTION BOX Two T*hot Temp Signals T wo T*cold Temp Signals P1 P2 and P3 TRAIN A TRAIN B 8-- REFERENCE JUNCTION BOX wo T-hot Temp Signals T T wo T -cold Temp Signals P1 P2 and P3 RTD Signals TIC Signals 120 V ac HTD Signals TIC Signals 120 V ac Class Non*Ciass 1E.. I
- 1E Annunciator Outputs 1
t I I MODEM NSSS ~ BOP _I I I TERMINATION I BOARD I ASSEMBLY I 1.------------, I r-- REMOTE DISPLAY I I t 120 V ac I I ~ ANALOG METER I MICRO-I PROCESSOR ASSEMBLY I I J RECORDER I t I 120 V ac Annunciator Outputs t I I MODEM I NSSS BOP I I I I TERMINATION I BOARD ASSEMBLY I I ------------, I REMOTE DISPLAY I t I 120 V ac I I ANALOG METER 1--- Non*Ciass MICRO-1E PROCESSOR Class ---I ASSEMBLY 1E I RECORDER I t I I t Notes: 120 V ac REV. OL-7 5/94
- 1.
P1 is a wide range loop pressure.
- 2.
P2 and P3 are narrow range pressurizer pressures.
- 3.
Material type for TIC is shown below. Type K extension wire is minml insulated chromellalumel wile. ~Chrome! ~Aiumel CALLAWAY PLANT FIGURE18.2-12 FUNCTIONAL DIAGRAM (REACTOR CORE SUBCOOLING MONITOR) I
PENETRATION OUTLET MOVABLE DETECTOR CONDUIT TRAIN A OUTLET WIDE RANGE NARROW RANGE TRAIN B CALLAWAY PLANT FIGURE 18.2-13 REACTOR VESSEL LEVEL INSTRUMENTATION SYSTEM REV. 1 5/15 l
100 90 80 70 ~ 60 a: w s: 0 Q. 50 a: 0 1-u <( w 40 a: 30 20 10 BOl NO PORV ACTUATION (REACTOR TRIP DUE TO P-9) PORV ACTUATED NO PORV ACTUATION (SPRAY ADEQUATE TO CONTROL OVERPRESSURE) MOl CORE HISTORY EOl CALLAWAY PLANT FIGURE 18.2-14 Rev. OL-0 6/86 PORV OPENING BAND-TURBINE TRIP WITH CONDENSER UNAVAILABLE
8 7 6 <OlvOrSZZ-v-J BCB 0------L[i]~ ~ yo11(J) BCD V106 V107 LEG SAMPLE 5 e[_4] ~= I ~011 I I CIS-A l_~ I CLOSES' I 1" I *(A TEST _ ZS CONN. 129 0 T 4 BCB BCD .::=::.;;; 1 " rllll~f----1*1---J TEST V1 08 V1 09 CONN. LOOP 3 HOT l...:;uBING [!J 02 1-BCB-17" L_ 1 " x 3 'a I NOTE 9 I ~ 021-BCB-1" 021-BCB-1" ~ > M-22BB01 >----tcyi_, i v 1
- J--------'-"~
1 E~ 4 1~---c}--!T-t-:}----,r--+.. -------------1----.....::.;;;.;_;r....:....----..... --:;:;.;....::..::.::.....;.I_...L.. __ -{::<<:}-""Jr--__;i' 16_71 BB-V046 r ocE~IALY ' F.c. I v1o2 F.c. r:::::::: F.c. v~:yo3 v1oo I I P-641 I 021 -BCB-1 " 1 "x 318" (TYP. 6 PLCS.) BCB I NOTE 9 1-.L_ ___ d, V1 04 V 1 OS ~ 'il IE-4 ! TUBING TUBING ~ c= ~ 1" ~L'J I l-...... f--.. +-J TEST CONN. 1 ~IS N & VENT t-o I 13oo11 GV----L-~ I zs yo11~ 20 0 ~v V101 V894 BCB BCD e[i] ~~ I I ccLioss-EAs2-+------ l r;;;: I~ LIQUID SAMPLE "V X PRESSURIZER I...:;UBING ) <e->e I NOTE 9 I ~ M-2 2 B B 02 !_;C(!__:J---.----'\\v/'-_..---{::)olloi(::J---_:.:.;I:;:E~ 4 f-1.:_ __ L_ _ _j BB-V112 DELAY~ I A-71 COIL I NOTE 9 1-~---~ I E-4 I TUBING F. C. TUBING G0 j-----ep011 I V070 111 ~ TEST ~--.~~~~t---, CONN. 0 u OJ I ~o11 I I CIS-A )~ I CLOSES' I L.c.l_.~ s 001-BCB-1" 001-BCB-1" -*\\;3~~ s >23*~ 021-BCB-1" 021-BCB-1 II BCB voss V056 001-BCB-1" v ~ I V054 V11 6 - [1] ---0-----l IJ~ I ~011 I I I TO HV-21
( M-22EJ01 IE -71 I NOTE 19 1-TUBING 1 1/
3" X ~8 !NOTE 91 I C-4 I G-----L[_4]~ zs yo11~ I 3 0 ~3) I CIS-A l_ ~ I CLOSES'y I __ ?s ~ I OJ u OJ I 8--L_@ LOOP 1 HOT I...:;UBING LEG SAMPLE I NOTE 9 I TUB IN~ I '-.__s./'o- ~ s L N 0 TUBING
- e
- :
) M-22BBD1 >---tcX:L v I G 4 I BB-V007 ~ DELAY ~ I E 4 I V053 F. C. ~ F.C. @i'-/'.) :011~ "/ NUCLEAR SAMPLE STATION COIL 8 I NOTE 9 I--'-~------' IE-41 TUBING 1 1/ ~ TEST CONN. ~--1-f-..... --1 & VENT ~DO-; rvo,;', BCD BCB TUBING 7 001-BCB-1" I ITI u OJ I 0 0 ,------ 1 " S. W
- CAP ------,
BCB BCB 6 001-BCB-1 II F. C. -mw--l J~ I l 3Yo11 I I TO HV-22
( M-22EJ01 I D-7 I I NOTE 1 9 I 5
1 II X 3/a" F. C. BCB TUBING 4 "' ~ w " r-I D U z ~ 3 3 2 2 1 NOTES:
- 1. SEE DRAWING M-22SJ01 FOR NOTES.
AS-BUILT REV. DATE DRAWN 2 9/3/91 SBR CHKD. SUPV. APPD. RLW TJM N/A REDRAWN FOR CLARITY REV. DATE DRAWN 3 1o1o9s DLB1 CHKD. SUPV. APPD. RLW AMR N/A INCORP. RFR-16448 REV. DATE DRAWN 4 o1oJ% RL W CHKD. SUPV. APPD. DLBc AMR N/ A INCORP. RFR-16S1 OA. REV. DATE DRAWN 5 112697 RLW CHKD. SUPV. APPD. DLBc AMR N/ A INCORP. DEC-1478 REV. DATE DRAWN 6 072501 RLW CHKD. SUPY. APPD. EWM AMR N/A INCORP. RFR-21 026A. REV. DATE DRAWN 7 ososo2 SKC CHKD. SUPY. APPD. DJB TWS N/A INCORP. MP 01-1002A I PARTIAL I REV. DATE DRAWN 8 oa2102 RLW CHKO. SUPV. APPD. EWM AMR N/A INCORP. MP 01-1002A !PARTIAL I REV. DATE DRAWN 9 oaz1oz RLW CHKD. SUPV. APPD. 8W~ TWS N/A INCORP. MP 01-1002A !PARTIAL I REV. DATE DRAWN 10 091302 RLW CHKO. SUPV. APPD. EWM TWS N/A INCORP. MP 01-1002A I PARTIAL! REV. DATE 11 1 002 02 DRAWN CHKD. SUPV. RLW EWM TWS INCORPORATE MP 01-1 002A I PARTIAL I REV. DATE 1 2 1 031 02 DRAWN CHKD. SUPV. RL W MAL DLB INCORPORATE MP 01-1002A I PARTIAL I REV. DATE 13 111002 DRAWN CHKD. SUPV. EWM DJB JDW INCORPORATE MP 01-1 002A. REV. DATE 14 04190S DRAWN CHKD. SUPV. MAL RLW TWS INCORP. RFR 22941A CLASS 1 DRAWN WATE I PIPING AND ~'="'"-*--,=,"~"INSTRUMENTATION DIAGRAM N/A N/A ~s=upv-. --,=,.,~, NUCLEAR SAMPL I N.Q, SYSTEM (FSAR FIGURE 18.2-1S.}""") N/A APPO. (0/I.T[ J LOCATION N/A UNION ELECTRIC COMPANY ST. LOUIS. MD CALLAWAY PLANT
- \\~
CLASS REV. 1 4 M-22SJ04(Q) 1 H G F E D c B A}}