NL-18-044, Supplemental Information Regarding the Review of the License Renewal Application

From kanterella
(Redirected from ML18183A147)
Jump to navigation Jump to search

Supplemental Information Regarding the Review of the License Renewal Application
ML18183A147
Person / Time
Site: Indian Point  
Issue date: 06/25/2018
From: Vitale A
Entergy Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CAC MD5407, CAC MD5408, NL-18-044
Download: ML18183A147 (4)


Text

~Entergx Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, N.Y. 10511-0249 Tel (914) 254-6700 NL-18-044 June 25, 2018 Anthony J. Vitale Site Vice President U.S. Nuclear Regulatory Commission Document Control Desk 11545 Rockville Pike, TWFN-2F1 Rockville, MD 20852-2738

SUBJECT:

REFERENCES:

Dear Sir or Madam:

Supplemental Information Regarding the Review of the Indian Point Nuclear Generating Unit Nos. 2 and 3 License Renewal Application (LRA) (CAC Nos. MD5407 and MD5408)

Docket Nos. 50-247 and 50-286 Licenses Nos. DPR-26 and DPR-64

1)
2)
3)

Entergy Letter, "Reply to Request for Additional Information for the Review of the Indian Point License Renewal Application RAI SET 2017-03 (CAC Nos.

MD5407 and MD5408)," dated May 18, 2017 Entergy Letter, "Request for Additional Information for the Review of the Indian Point License Renewal Application RAI SET (CAC Nos. MD5407 and MD5408)," dated May 19, 2017 Entergy Letter, "Comments on Proposed Director's Decision for 1 O CFR 2.206 Petition on Indian Point Baffle Former Bolts Filed by the Union of Concerned Scientists Docket Nos. 50-247 and 50-286 (License Nos. DPR-26 and DPR-64)," dated February 09, 2017 By email date June 06, 2018, the Nuclear Regulatory Commission (NRC) identified "several questions" that needed answers to support completion of the license renewal application Safety Evaluation Report for Indian Point Nuclear Generating Unit Nos. 2 and 3 (Indian Point). The questions asked by the NRC and the Indian Point responses are included in Attachment 1 of this letter.

Entergy is making no new commitments in this letter. Should you have any questions regarding this matter, please contact Mr. Robert Walpole, Manager, Regulatory Assurance, Indian Point Energy Center at (914) 254-6710.

Sincerely,

~~~~==--=~~~~,~

~-

AJV/trj

Attachment:

1.

Response to email from NRC date June 06, 2018, Regarding the License Renewal Application - Safety Evaluation Report cc:

Mr. David Lew, Acting Regional Administrator, NRC Region I Mr. Sherwin E. Turk, NRC Office of General Counsel, Special Counsel Mr. William Burton, NRC Senior Project Manager, Division of License Renewal Mr. Richard V. Guzman, NRR Senior Project Manager Ms. Bridget Frymire, New York State Department of Public Service Ms. Alicia Barton, President and CEO NYSERDA NRC Resident Inspector's Office

-- --~------

ATTACHMENT 1 to NL-18-044 RESPONSE TO EMAIL FROM NRC DATE JUNE 06, 2018 REGARDING THE LICENSE RENEWAL APPLICATION - SAFETY EVALUATION REPORT ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 & 3 DOCKET NOS. 50-247 AND 50-286

Docket Nos. 50-247 and 50-286 NL-18-044 Page 1 of 1 Response to email from NRC date June 06, 2018, Regarding the License Renewal Application - Safety Evaluation Report By email dated June 06, 2016, the NRC asked the following questions:

1. Question: By letter dated May 18, 2017, IPEC stated that it would implement an enhancement to the Bolting Integrity Program before May 31, 2018. Has this been done?
a. Answer: Yes, we are in the implementation phase of this enhancement. A program has been developed and a number of potential opportunistic inspections selected.
2. Question: By letter dated May 19, 2017 IPEC identified an enhancement to the "detection of aging effects" program element in the Steam Generator Integrity program to revise applicable procedures to specify a general visual inspection of the steam generator channel head (Commitment No. 54), consistent with LR-ISG-2016-01, by December 31, 2017. Has this been done?
a. Answer: Yes, the steam generator integrity program procedures have been revised to specify a general visual inspection of the steam generator channel head.
3. Question: By letter dated February 6, 2017, IPEC that the IP3 baffle-bolt inspections previously scheduled to be performed in 3R20 (spring 2019) will be performed in 3R19 (spring 2017). Visual and UT inspections on 100 percent of all accessible BFBs, and a visual inspection of the baffle-edge bolts and baffle-former assembly, will be performed in 3R19. Has this been done?
a. Answer: The actual date of the letter was February 9, 2017. During the 3R19 we inspected all baffle bolts and replaced all of the bolts which either had flaws or could not be inspected. All baffle bolts were ir.ispected visually and with UT. All baffle bolts that had any indications of flaws were replaced as documented in EC 71081. All baffle bolt location contained either an existing baffle bolt that showed no indications of flaws OR were replaced with a new design. We also performed a visual inspection of the baffle-edge bolts and baffle-former assembly and no unacceptable indications were identified.