n

    • ~

~.

/

VIRGINIA ELECTRIC AND PowER COMPANY RICHMOND, VIRGINIA 23261 February 28, 1991 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.

20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 Serial No.

NURBP Docket Nos.

License Nos.

INDEPENDENT SPENT FUEL STORAGE INSTALLATION SEMI-ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT 91-097 RO 50-280 50-281 72-2 DPR-32 DPR-37 SNM-2501 Enclosed is the Surry Power Station Semi-Annual Radioactive Effluent Release Report for July 1, 1990, through December 31, 1990. The report, submitted pursuant to Surry Power Station Technical Specification 6.6.8.3 and ISFSI Technical Specification 1.4.1 of Appendix C, includes a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released during the previous six months, as outlined in Regulatory Guide 1.21, Revision 1, June 1974.

Very truly yours, I{/- ~au-~

.,(crV'J. L. Stewart

()

Senior Vice President - Nuclear Attachment cc:

U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.

Suite 2900 Atlanta, Georgia 30323 Mr. W. E. Holland NRC Senior Resident Inspector Surry Power Station Mr. Robert M. Bernero, Director Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, D. C.

20555

(.-

.-. *11--**-* 1 91030601JL !l~~~"n~

F,,.,R A"C1nr:1< 05000..::.,::-0

-1,.;

F'DR

,-~

ATTACHMENT SEMI-ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SURRY POWER STATION UNITS 1 AND 2 LICENSE NOS. DPR-32 AND DPR-37 INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE NO. SNM-2501

SEMI-ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SURRY POWER STATION (July 1, 1990 Through December 31, 1990)

Prepared By: JZ~ 1:gL-t Supervisor Radiological Analysis Reviewed By: ~_,j.xJ~

SuJ>e"or Health Physics Technical Services Approved By:

Id-f-..-t:~

Superintendent Radiological Protection

FORWARD This report is submitted as required by Appendix A to Operating License No. 1s DPR-32 and DPR-37, Technical Specifications for Surry Power Station, Units 1 and 2, Virginia Electric and Power Company, Docket No. 1s 50-280, 50-281, Section 6.6.B.3.

and as required by Appendix C to Materials License No.

SNM-2501, Technical Specifications for Environmental Protection for Surry Independent Spent Fuel Storage, Docket No. 72-2, Section 1.4.1.

Section No.

1 2

3 RADIOACTIVE EFFLUENT RELEASE REPORT FOR THE SURRY POWER STATION (July 1, 1990 Through December 31, 1990)

Index Subject Purpose and Scope Discussion Page 1

Supplemental Information Effluent Release Data Annual and Quarterly Doses Revisions to Offsite Dose Calculation Manual (ODCM) Revisions to Process Control Program (PCP) Major Changes to Radioactive Liquid, Gaseous and Solid Waste Treatment Systems Inoperability of Radioactive Liquid and Gaseous Effluent Instrumentation Unplanned Releases Lower Level of Detection (LLD) for Effluent Analysis 1&2 2

.Page 1 of 2

1.0 Purpose and Scope

The Radioactive Effluent Release Report includes a summary of the quantities of radioactive liquid and gaseous effluents and solid waste as outlined in Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants'\\ Revision 1, June 1974, with data summarized on a quarterly basis following the format of Tables 1, 2 and 3 of Appendix B thereof. The report submitted within 60 days after January 1 of each year includes an assessment of radiation doses to the maximum exposed member of the public due to radioactive liquid and gaseous effluents released from the site during the previous calendar year. The report also includes a list of unplanned releases during the reporting period.

As required by Technical Specification 6.8B, changes to the ODCM for the time period covered by this report are included. Information is provided to support the changes along with a package of those pages of the ODCM changed.

This report includes changes to the PCP with information and documentation necessary to support the rationale for the changes as required by Technical Specification 6.8A.

Major changes to the radioactive liquid, gaseous and solid waste treatment systems are required to be reported in accordance with Technical Specification 6.9. If changes are made to these systems, the report shall include information to support the reason for the change and a summary of the 1 OCFR50.59 evaluation. In lieu of reporting major changes in this report, major changes to the radioactive waste treatment systems may be submitted as part of the annual FSAR update.

As required by Technical Specification 3.7E.2, a list and explanation for the inoperability of radioactive liquid and/or gaseous effluent monitors are provided in this report.

2.0 Discussion The basis for the calculation of the percent of technical specification for the critical organ in Table lA of Attachment 1, is Technical Specification 3.1 lB.l.a (ii). Technical Specification 3.llB.l.a (ii) requires that the dose rate for iodine -

131, for tritium, and for all radionuclides in particulate form with half-lives greater than 8 days shall be less than or equal to 1500 mRem/yr to the critical organ at or beyond the site boundary. The critical organ is the child's thyroid, inhalation pathway.

The basis for the calculation of percent of technical specification for the total body and skin in Table lA of Attachment 1, is Technical Specification 3.llB.l.a (i). This Technical Specification requires that the dose rate for noble gases to areas at or beyond site boundary shall be less than or equal to 500 mRem/yr to the total body and less than or equal to 3000 mRem/yr to the skin.

The basis for the calculation of the percent of technical specification in Table 2A of, is Technical Specification 3.11 A. l.a. Technical Specification 3.11 A.1.a states that the concentration of radioactive material released in liquid effluents to unrestricted areas shall be limited to the concentrations specified in 1 OCFR20, Appendix B, Table II, Column 2 for radionuclides other than dissolved or entrained noble gases.

For dissolved or entrained noble gases, the concentration shall be limited to 2 X 1 o-4 micro curies/ ml.

age 2 of 2 Percent of technical specification calculations are based on the total gaseous or liquid effluents released for that respective quarter.

The annual and quarterly doses, as reported in Attachment 2, were calculated according to the methodology presented in the ODCM. The beta and gamma air doses due to noble gases released from the site were calculated at the site boundary. The maximum exposed member of the public from the release of airborne iodine -

131, tritium and all radionuclides in particulate form with half lives greater than 8 days, is defined as an infant, exposed through the grass-cow-milk pathway, with the critical organ being the thyroid gland. The maximum exposed member of the public from radioactive materials in liquid effluents in unrestricted areas is defined as an adult, exposed by either the invertebrate or fish pathway, with the critical organ being either the thyroid gland or gastrointestinal-lower large intestine. The total body dose was also determined for this individual.

Unplanned releases presented in Attachment 7 are defined in Technical Specification 6.6.B.3 as those gaseous releases exceeding Technical Specification 3.11.B.l.a and those liquid releases exceeding Technical Specification 3.11.A. l.a.

The typical lower level of detection (LLD) capabilities of the radioactive effluent analysis instrumentation are presented in Attachment 8.

These LLD values are based upon conservative conditions (i.e., minimum sample volumes and maximum delay time prior to analysis). Actual LLD values may be lower. If an isotope is not detected when analyzing effluent samples, then the activity of that isotope will be reported as Not Detected (N /D) on Attachment 1 of this report. When all isotopes listed on Attachment 1 for a particular quarter and release mode are less than the lower level of detection, then the totals for this period will be designated as Not Applicable (N / A).

3.0 Supplemental Information Technical Specification 3.11.D. l.d requires the identification of the cause for the unavailability of milk or leafy vegetation samples, required by Technical Specification, Table 4.9-3, and identification for obtaining replacement samples. All milk and leafy vegetation samples required by Table 4.9-3 were available for collection during the period of July 1, 1990 through December 31, 1990.

Technical Specification 3.11.D.2.b requires the identification of new sample locations determined with the Land Use Census as yielding a calculated dose or dose commitment greater than the values being calculated in Technical Specification 4.9.C. No new sample location(s) that may yield a greater dose or dose commitment than are currently used in Technical Specification 4.9.C, were identified in the Land Use Census.

Dry Cask Independent Spent Fuel Storage Installation Technical Specification Appendix C, 1.4.1 requires reporting the quantity of each of the principal radionuclides released from the installation to the environment in liquid and gaseous effluents during the previous 6 months of operations. There were no liquid or gaseous effluent releases from the Dry Cask Independent Spent Fuel Storage Installation during the period of July l, 1990 through December 31, 1990.

.ttachment 1 EFFLUENT RELEASE DATA (July 1, 1990 Through December 31, 1990)

TABLE 1A

  • Page 1 of 7 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT PERIOD: 7/1/90 TO 12/31/90 GASEOUS EFFLUENT-SUMMATION OF ALL RELEASES SURRY POWER STATION UNITS 1&2 UNIT THIRD QTR.

FOURTH QTR.

% EST. ERROR A. FISSION & ACTIVATION GASES

1. TOTAL RELEASE Ci 3.08E+02 8.84E+01 1.80E+01
2. AVE RELEASE RATE FOR PERIOD

µCi/sec 3.87E+01 1.11E+01 B. IODINE

1. TOTAL 1-131 Ci 1.27E-04 8.54E-04 2.80E+01
2. AVE RELEASE RATE FOR PERIOD

µCi/sec 1.60E-05 1.07E-04 C. PARTICULATE

1. HALF-LIFE >8 DAYS Ci
1. 71 E-04 2.61 E-04 2.80E+01
2. AVE RELEASE RATE FOR PERIOD

µCi/sec 2.16E-05 3.29E-05

3. GROSS ALPHA RADIOACTIVITY Ci 6.33E-07 2.94E-07 D. TRITIUM
1. TOTAL RELEASE Ci 4.67E+OO 4.68E+OO 3.10E+01
2. AVE RELEASE RATE FOR PERIOD

µCi/sec 5.88E-01 5.88E-01 PERCENTAGE OF T.S. LIMITS CRITICAL ORGAN DOSE RATE 3.46E-03 9.48E-03 TOTAL BODY DOSE RATE 6.67E-02 2.26E-02 SKIN DOSE RATE 2.53E-02 8.92E-03

TABLE 1 B Page 2 of 7 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT PERIOD: 7/1/90 TO 12/31/90 GASEOUS EFFLUENTS-MIXED MODE RELEASES CONTINOUS MODE BATCH MODE SURRY POWER STATION UNITS 1&2 UNIT THIRD FOURTH THIRD FOURTH QUARTER QUARTER QUARTER QUARTER

1. FISSION & ACTIVATION GASES KR-85 Ci N/D 1.28E-01 2.60E+OO 1.76E+OO KR-85M Ci N/D N/D 1.94E-02 N/D KR-87 Ci N/D N/D N/D N/D KR-88 Ci N/D N/D 1.02E-02 N/D XE-133 Ci 1.67E+01 5.06E+OO 1.59E+02 3.06E+01 XE-135 Ci 1.81E-01 2.28E-01 8.66E-01 1.47E-04 XE-135M Ci N/D N/D N/D N/D XE-138 Ci N/D N/D N/D N/D XE-131M Ci N/D 4.66E-02 1.74E+OO 6.02E-01 XE-133M Ci N/D 2.12E-02 1.13E+OO 1.31E-01 AR-41 Ci N/D 1.31E-01 1.1 OE-02 N/D TOTAL FOR PERIOD Ci 1.69E+01 5.61 E+OO 1.65E+02 3.31 E+01
2. IODINES 1-1 31 Ci 1.14E-06 7.91 E-06 2.47E-07 7.55E-06 1-132 Ci N/D
1. 79E-07 N/D N/D 1-133 Ci 4.46E-07 3.82E-07 1.33E-08 N/D 1-135 Ci N/D N/D N/D N/D TOTAL FOR PERIOD Ci 1.58E-06 8.47E-06 2.60E-07 7.55E-06
3. PARTICULATES SR-89 Ci N/D N/D N/D N/D SR-90 Ci N/D N/D N/D N/D CS-134 Ci N/D N/D N/D N/D CS-137 Ci 1.50E-07 1.58E-07 N/D N/D BA-140 Ci N/D N/D N/D N/D LA-140 Ci N/D N/D N/D N/D C0-60 Ci 2.63E-07 2.57E-07 N/D N/D CS-138 Ci N/D N/D N/D N/D C0-58 Ci N/D 1.52E-08 N/D N/D RB-88 Ci N/D N/D N/D N/D SE-75 Ci N/D 1.05E-08 N/D N/D SB-125 Ci N/D 6.1 ?E-09 N/D N/D CR-51 Ci N/D N/D N/D N/D NB-95 Ci N/D N/D N/D N/D AG-110M Ci N/D N/D N/D N/D MN-54 Ci N/D N/D N/D N/D

TABLE 1C EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT PERIOD: 7/1/90 TO 12/31/90 GASEOUS EFFLUENTS-GROUND LEVEL RELEASES CONTINOUS MODE Page 3 of 7 BATCH MODE SURRY POWER STATION UNITS 1&2 UNIT THIRD r

FOURTH THIRD FOURTH QUARTER QUARTER QUARTER QUARTER

1. FISSION & ACTIVATION GASES KR-85 Ci 2.02E-02 N/D N/D N/D KR-85M Ci 5.76E-02 N/D N/D 3.65E-04 KR-87 Ci 9.51 E-02 N/D N/D 2.16E-04 KR-88 Ci 1.24E-01 N/D N/D 6.13E-04 XE-133 Ci 1.25E+02 3.62E+01 N/D 1.34E+01 XE-135 Ci 4.35E-01 5.40E-04 N/D 6.56E-02 XE-135M Ci 1.05E-01 N/D N/D
8. 77E-05 XE-138 Ci 2.BOE-01 N/D N/D N/D XE-131 M Ci N/D N/D N/D 1.87E-02 XE-133M Ci 2.50E-01 N/D N/D 3.48E-03 AR-41 Ci 7.09E-02 N/D N/D 1.16E-02 TOTAL FOR PERIOD Ci 1.26E+02 3.62E+01 N/A 1.35E+01
2. IODINES 1-131 Ci 1.26E-04 6.61 E-04 N/D
1. 78E-04 1-132 Ci 1.73E-05 4.98E-03 N/D 5.47E-05 1-133 Ci 2.55E-04 7;60E-05 N/D 2.27E-05 1-135 Ci 2.96E-05 N/D N/D N/D TOTAL FOR PERIOD Ci 4.28E-04 5.72E-03 N/A 2.55E-04
3. PARTICULATES SR-89 Ci N/D N/D N/D N/D SR-90 Ci N/D N/D N/D N/D CS-134 Ci 6.93E-06 1.25E-07 N/D 4.36E-06 CS-137 Ci 1.11E-04 4.85E-05 N/D 3.60E-05 BA-140 Ci N/D N/D N/D N/D LA-140 Ci N/D N/D N/D N/D C0-60 Ci 4.03E-05 4.42E-05 N/D 1.77E-05 CS-138 Ci 9.1 BE-05 N/D N/D N/D C0-58 Ci 1.26E-05 6.67E-05 N/D 4.96E-06 RB-88 Ci 1.11 E-04 N/D N/D N/D SE-75 Ci N/D N/D N/D N/D SB-125 Ci N/D N/D N/D N/D CR-51 Ci N/D 2.89E-05 N/D N/D NB-95 Ci N/D 5.03E-06 N/D N/D AG-110M Ci N/D 3.0BE-06 N/D N/D MN-54 Ci N/D 1.17E-06 N/D N/D

TABLE 2A

  • Page 4 of 7 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT PERIOD: 7/1/90 TO 12/31/90 LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SURRY POWER STATION UNITS 1&2 A. FISSION AND ACTIVATION PRODUCTS
1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
2. AVE OIL. CONG. DURING PERIOD
3. PERCENT OF APPLICABLE LIMIT B. TRITIUM
1. TOTAL RELEASE
2. AVE OIL. CONG. DURING PERIOD
3. PERCENT OF APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES
1. TOTAL RELEASE
2. AVE OIL. CONG. DURING PERIOD
3. PERCENT OF APPLICABLE LIMIT D. GROS$ ALPHA RADIOACTIVITY
1. TOTAL RELEASE E. VOLUME OF WASTE RELEASED (PRIOR TO DILUTION)

F. VOLUME OF DILUTION WATER USED DURING PERIOD UNIT Ci

µCi/ml Ci

µCi/ml Ci

µCi/ml Ci LITERS LITERS THIRDQTR.

3.42E-01

4. 73E-10 2.0SE-03 2.81 E+02 3.89E-07 1.30E-02 2.75E+OO 3.BOE-09 1.90E-03 O.OOE+OO 4.16E+07 7.23E+11 FOURTHQTR.

1.95E+OO 4.41 E-09 2.62E-02 1.43E+02 3.23E-07 1.0BE-02 4.87E-01 1.10E-09 5.SOE-04 5.97E-05 4.11E+07 4.42E+11

%EST.ERROR 2.00E+01 2.00E+01 2.00E+01 2.00E+01 3.00E+OO 3.00E+OO

TABLE 28 Page 5 of 7 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT PERIOD: 7/1/90 TO 12/31/90 LIQUID EFFLUENTS CONTINOUS MODE BATCH MODE SURRY POWER STATION UNITS 1&2 UNIT THIRD FOURTH THIRD FOURTH QUARTER QUARTER QUARTER QUARTER SR-89 Ci N/D N/D N/D N/D SR-90 Ci N/D N/D N/D N/D CS-134 Ci 4.40E-05 1.68E-05 2.BBE-02 5.BSE-02 CS-137 Ci 1.41 E-02 1.45E-02 1.46E-01 2.59E-01 1-1 31 Ci N/D N/D 4.0BE-04 2.42E-02 C0-58 Ci N/D 1.31 E-03 1.44E-02 3.21 E-01 C0-60 Ci 5.12E-05 2.1 BE-04 5.13E-02 1.62E-01 FE-59 Ci N/D N/D N/D 1.84E-02 ZN-65 Ci N/D N/D 1.38E-06 9.21 E-05 MN-54 Ci N/D 2.13E-05 8.13E-04 7.04E-03 CR-51 Ci N/D 1.20E-04

1. 72E-02 2.1 SE-01 ZR-95 Ci N/D N/D 7.79E-06 1.48E-02 NB-95 Ci N/D 1.87E-05 1.02E-03 2.17E-02 M0-99 Ci N/D N/D N/D 4.83E-06 TC-99M Ci N/D N/D 4.98E-05 4.14E-05 BA-140 Ci N/D N/D 1.14E-05

. N/D LA-140 Ci N/D N/D 7.45E-06 2.12E-04 CE-141 Ci N/D N/D N/D 4.1 SE-04 C0-57 Ci N/D N/D 7.84E-06 5.81 E-04 SB-125 Ci N/D N/D 1.52E-02 2.69E-01 AG-110M Ci N/D N/D 1.BBE-03 1.40E-02 RU-103 Ci N/D N/D 1.63E-04 6.SBE-03 SB-124 Ci N/D N/D

5. 78E-06 1.96E-02 1-133 Ci N/D N/D 6.07E-05 1.17E-04 NA-24 Ci N/D N/D 2.11 E-06 1.90E-04 FE-55 Ci N/D N/D 5.0SE-02 5.18E-01 TE-132 Ci N/D N/D 2.68E-06 5.51 E-04 RB-88 Ci N/D N/D 2.SOE-04 N/D 1-132 Ci N/D N/D
1. 72E-06 2.SSE-04 CE-144 Ci N/D N/D N/D 3.39E-04 NA-22 Ci N/D N/D N/D 1.91 E-06 ND-147 Ci N/D N/D N/D 1.92E-05 TOTAL FOR PERIOD Ci 1.41 E-02 1.62E-02 3.28E-01 1.93E+OO XE-133 Ci N/D N/D 2.66E+OO 4.62E-01 XE-135 Ci N/D N/D 4.07E-02 1.SSE-02 XE-135M Ci N/D N/D 1.42E-03 1.23E-03 XE-133M Ci N/D N/D 2.59E-02 5.SBE-03 XE-131 M Ci N/D N/D 1.BSE-02 2.33E-03 AR-41 Ci N/D N/D 5.83E-04 2.11E-04 KR-88 Ci N/D N/D 3.BSE-05 2.22E-05 KR-85M Ci N/D N/D 3.37E-05 N/D KR-87 Ci N/D N/D 1.02E-05 2.12E-05

TABLE 3

  • Page 6 of 7 EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT SOLID WASTE AND IRRADIATED FUEL SHIPMENTS PERIOD 07/01/90-12/31/90 SURRY POWER STATION A.

SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL(Not irradiated fuel)

1. Type of waste Unit 6-month Est.Total Period Error,%
a. Spent resins, filter sludges, evaporator m3 2.28E+Ol 1.00E+Ol bottoms, etc.

Ci 7.08E+02 3.00E+Ol

b. Dry compressible waste, contaminated m3 4.53E+02*

1.00E+Ol equip., etc.

Ci 4.93E+OO 3.00E+Ol

c. Irradiated components, control m3 O.OOE+OO O.OOE+OO rods, etc.

Ci O.OOE+OO O.OOE+OO

d. Organic waste(i.e. oil and scintillation m3 O.OOE+OO O.OOE+OO fluid)

Ci O.OOE-00 O.OOE+OO

2. Estimate of major nuclide composition(by type of waste)
a. Co-60 3.08E+Ol Cs-137
2. 76E+O 1 Ni-63 1.83E+Ol Fe-55 Of_

/0 1.21E+Ol Cs-134 7.14E+OO Be-07 1.21E+OO

b. Fe-55 3.0SE+O 1 Co-60 3.0ZE+Ol Ni-63 2.53E+Ol Cs-137 1.19E+Ol Cs-134 l.40E+OO
c.
d.

TABLE 3

  • Page 7 of 7 EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT SOLID WASTE AND IRRADIATED FUEL SHIPMENTS PERIOD 07/01/90-12/31/90
3. Solid Waste Disposition Number of Shipments 8

8 (continued)

Mode of Transportation Truck Truck Destination Barn well, SC Oak Ridge, TN B.

IRRADIATED FUEL SHIPMENT(Disposition)

Number of Shipmen ts 0

Mode of Transportation Destination

  • NOTE: Dry active waste was shipped to a licensed waste processor for volume reduction. Therefore, this volume is not representative of the actual volume buried. The total volume of dry active waste buried for the reporting period was 6.91E+Ol m3.

Total Body (mRem) 1st Quarter 5.89E-03 2nd Quarter 6.34E-03 3rd Quarter 1.43E-03 4th Quarter 1.0lE-02 Annual 2.38E-02 ANNUAL AND QUARTERLY DOSES LIQUID Thyroid GI-LLI Gamma (mRem)

(mRem)

(mRad)

1. OOE-03 7.79E-03 4.29E-02 1.0SE-04 1.85E-02
1. 0 6E-04 7.44E-05 3.49E-03 9.91E-02 2.94E-03 7.41E-02 3.43E-02 4.12E-03 l.04E-01
1. 7 6E-01 Page 1 of 1 GASEOUS Beta Thyroid (mRad)

(mRem)

9. 76E-02 3.06E-03 3.52E-04 4.lSE-03 2.64E-01 2.64E-03 1.0lE-01 1.69E-02 4.63E-01 2.68E-01

Page 1 of 1 REVISIONS TO OFFSITE DOSE CALCULATION MANUAL (ODCM)

There were no changes to the Offsite Dose Calculation Manual (ODCM) during the period of July 1, 1990 through December 31, 1990.

Page 1 of 1 REVISIONS TO THE PROCESS CONTROL PROGRAM (PCP)

There were no changes to the Process Control Program during the period of July 1, 1990 through December 31, 1990.

Page 1 of 1 MAJOR CHANGES TO RADIOACTNE LIQUID, GASEOUS AND SOLID WASTE TREATMENT SYSTEMS There were no major changes to Surry1s Radioactive Liquid, Gaseous or Solid Waste Treatment Systems during the period of July 1, 1990 through December 31, 1990.

Page 1 of 1 INOPERABILITY OF RADIOACTIVE LIQUID AND GASEOUS EFFLUENT MONITORING INSTRUMENTATION Technical Specification 3.7.E.2 requires the Semi-Annual Report to include an explanation why monitors required by Technical Specification Tables 3. 7-5(a) and 3. 7-5(b) which were determined inoperable, were not returned to operable status within 30 days.

Two monitors require explanation under this criteria for the period of July 1, 1990 through December 31, 1990. They are the Component Cooling Heat Exchanger Service Water Monitor and the Waste Gas Holdup System, Explosive G.as Oxygen Monitor.

1. The installation of the new Component Cooling Heat Exchanger (CCHX) Service Water Radiation Monitors l-RM-SW-107A, Band D, under Design Change 89-21-3, is complete.

The design of this passive Radiation Montioring System should reduce the influence of biofouling experienced on the previous design and insure trouble free operability.

The installation of l-RM-SW-107C is scheduled for the spring 1991 Unit #2 Refueling Outage.

Grab sampling, as required by Table 3.7-5(a) when the monitor is out of service, has been performed since the monitor became inoperable and will continue until the new system is complete.

2. The installation of new and more reliable hydrogen and oxygen analyzers for the Waste Gas Holdup System was completed during the 1990 Unit # 1 Fall Refueling Outage. The work completed under Engineering Work Request (EWR)89-352 also included the redesign of the sample flow path.

Initial startup testing and calibrations indicate that the system will provide reliable, long term explosive gas monitoring. Local readout and alarm are currently available for both monitors with remote readout and alarm of the oxygen concentration available in the Control Room. Final close out of the EWR will be completed when remote indications for both monitors are available and minor startup problems are resolved.

Projected completion date during the first quarter 1991.

Grab sampling as required by Technical Specification Table 3. 7-5(b) when the monitor is out of service, has been performed since the monitor became inoperable. Even though installation is complete and local readout and alarms are operable, grab sampling will continue until final closeout of the EWR.

UNPLANNED RELEASES

.achment 7 Page 1 of 1 There have been no Unplanned Liquid or Gaseous Releases that exceeded Technical Specification 3.11.A.la and 3.11.B.l.a during the period July 1, 1990 through December 31, 1990.

v

!(',

GASEOUS:

LIQUID:

Page 1 of 1 LOWER LEVEL OF DETECTION FOR EFFLUENT SAMPLE ANALYSIS Isotope Required LLD Typical LLD (uCi/ml)

(uCi/ml)

Kr-87 1.00 E-04 4.25 E 6.40 E-07 Kr-88 1.00 E-04 3.76 E 5.65 E-07 Xe-133 1.00 E-04 2.12 E 3.07 E-07 Xe-133m 1.00 E-04 1.04 E 1.74 E-06 Xe-135 1.00 E-04 1.19 E 2.05 E-07 Xe-135m 1.00 E-04 2.63 E 3.73 E-06 Xe-138 1.00 E-04 5.09 E 1.02 E-05 I-131 l.OOE-12 2.16 E 3.48 E-13 Sr-89 l.OOE-11 7.00 E 9.00 E-14 Sr-90 1.00 E-11 2.00 E 2.00 E-14 Cs-134 1.00 E-11 1.54 E 3.31 E-13 Cs-137 1.00 E-11 2.26 E 1.02 E-12 Mn-54 1.00E-11 1.89 E 2.87 E-13 Fe-59 1.00 E-11 2.96 E 5.44 E-13 Co-58 l.OOE-11 1.65 E 3.94 E-13 Co-60 1.00 E-11 2.34 E 5.34 E-13 Zn-65 1.00 E-11 4.34 E 7.01 E-13 Mo-99 1.00 E-11 8.69 E 2.40 E-12 Ce-141 1.00 E-11 1.20 E 1.91 E-13 Ce-144 1.00 E-11 4.12 E 7.40 E-13 Alpha 1.00 E-11 9.58 E 1.18 E-14 Tritium 1.00 E-06 6.56 E 7.46 E-08 Sr-89 5.00 E-08 3.00 E 5.00 E-08 Sr-90 5.00 E-08 5.00 E 2.00 E-08 Cs-134 5.00 E-07 3.14 E 5.46 E-08 Cs-137 5.00 E-07 3.60 E 1.83 E-07 I-131 1.00 E-06 3.19 E 4.65 E-08 Co-58 5.00 E-07 2.74 E 6.59 E-08 Co-60 5.00 E-07 3.72 E 8.28 E-08 Fe-59 5.00 E-07 4.41 E 9.26 E-08 Zn-65 5.00 E-07 7.01 E 1.10 E-07 Mn-54 5.00 E-07 3.15 E-08.:. 4.78 E-08 Mo-99 5.00 E-07 1.48 E 3.38 E-07 Ce-141 5.00 E-07 2.62 E 4.72 E-08 Ce-144 5.00 E-07 1.04 E 1.81 E-07 Fe-55 1.00 E-06 5.00 E 1.00 E-06 Alpha 1.00 E-07 5.52 E 6.80 E-09 Tritium 1.00 E-05 1.83 E 2.06 E-06 Xe-133 1.00 E-05 5.16 E 7.49 E-08 Xe-135 1.00 E-05 2.47 E 3.71 E-08 Xe-133m 1.00 E-05 2.70 E 3.18 E-07 Xe-135m 1.00 E-05 3.91 E 6.51 E-07 Xe-138 1.00 E-05 1.05 E 1.94 E-06 Kr-87 1.00 E-05 8.62 E 1.31 E-07 Kr-88 1.00 E-05 8.47 E 1.51 E-07