| | | Reporting criterion |
|---|
| 05000281/LER-1994-001-01, :on 940124,both Auxiliary Exhaust Filter Trains Declared Inoperable Due to Excessive flow.Six-h Action Statement to Hot Shutdown of Facility Entered Until Normal 1J Bus Alignment Restored |
- on 940124,both Auxiliary Exhaust Filter Trains Declared Inoperable Due to Excessive flow.Six-h Action Statement to Hot Shutdown of Facility Entered Until Normal 1J Bus Alignment Restored
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) |
| 05000280/LER-1994-001-03, :on 940203,while Unit 1 Was at Cold Shutdown in Refueling Outage,Tack Weld Was Being Performed & Water Squirted from Opening in RCS Piping.Caused by H Gas in Pressurizer Being Ignited by Welding Arc |
- on 940203,while Unit 1 Was at Cold Shutdown in Refueling Outage,Tack Weld Was Being Performed & Water Squirted from Opening in RCS Piping.Caused by H Gas in Pressurizer Being Ignited by Welding Arc
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000281/LER-1994-002-01, :on 940307,filtered Exhaust Fan 1-VS-F-58B Tripped,Rendering Ventilation Filtered Exhaust Train Inoperable.Caused by Damper from Filter Was Found Halfway Shut.Filter Fully Opened & Device Tightened |
- on 940307,filtered Exhaust Fan 1-VS-F-58B Tripped,Rendering Ventilation Filtered Exhaust Train Inoperable.Caused by Damper from Filter Was Found Halfway Shut.Filter Fully Opened & Device Tightened
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) |
| 05000280/LER-1994-002-03, :on 940204,main Steam Safety Valves Found Out of Tolerance.Caused by Minor Setpoint Drift.Valves Inspected & Overhauled |
- on 940204,main Steam Safety Valves Found Out of Tolerance.Caused by Minor Setpoint Drift.Valves Inspected & Overhauled
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) |
| 05000280/LER-1994-003-01, :on 940204,hole in Recirculating Spray HX Svc Water Outlet Piping Identified.Caused by Failure of Coal Tar Epoxy Coating.Piping Inspected & Will Be Pressure Tested Per Station Procedures |
- on 940204,hole in Recirculating Spray HX Svc Water Outlet Piping Identified.Caused by Failure of Coal Tar Epoxy Coating.Piping Inspected & Will Be Pressure Tested Per Station Procedures
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000281/LER-1994-003-03, :on 940617,primary Grade Water Supply Manual Isolation Valve 2-CH-212 Found in Open Position During Cold Shutdown Condition Due to Personnel Error.Valve 2-CH-212 Immediately Isolated & Secured |
- on 940617,primary Grade Water Supply Manual Isolation Valve 2-CH-212 Found in Open Position During Cold Shutdown Condition Due to Personnel Error.Valve 2-CH-212 Immediately Isolated & Secured
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(B) |
| 05000281/LER-1994-004-03, :on 941007,inoperable Condition Noted During Performance of Corrective Maint on Station Battery 2A.Caused by Inadequate post-maint Testing & Cognitive Personnel Error by Util Engineer.Process Changed |
- on 941007,inoperable Condition Noted During Performance of Corrective Maint on Station Battery 2A.Caused by Inadequate post-maint Testing & Cognitive Personnel Error by Util Engineer.Process Changed
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000280/LER-1994-004, :on 940301,reactor Coolant Sys Loops Drained & Isolated.Caused by Personnel Error.Operations Dept Personnel Involved Counseled |
- on 940301,reactor Coolant Sys Loops Drained & Isolated.Caused by Personnel Error.Operations Dept Personnel Involved Counseled
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000280/LER-1994-005, :on 940330,steady State Reactor Power Exceeded Operating License Limit.Caused by Inadequate Instrumentation Change Control Process.Instrumentation Change Control Process Modified |
- on 940330,steady State Reactor Power Exceeded Operating License Limit.Caused by Inadequate Instrumentation Change Control Process.Instrumentation Change Control Process Modified
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000280/LER-1994-006, :on 940511,manual Reactor Trip Occurred During Safeguards Actuation Logic Testing.Caused by Inadvertent Actuation of Relay in Safety Injection Actuation Circuitry. Reactor Placed in Safe,Hot Shutdown Condition |
- on 940511,manual Reactor Trip Occurred During Safeguards Actuation Logic Testing.Caused by Inadvertent Actuation of Relay in Safety Injection Actuation Circuitry. Reactor Placed in Safe,Hot Shutdown Condition
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000280/LER-1994-007, :on 940614,Kaman Process Vent Radiation Monitors Were Declared Inoperable.Caused by Moisture Entrapment in System.Annunciator Response Procedure 0-RM-A-C-4 Was Performed |
- on 940614,Kaman Process Vent Radiation Monitors Were Declared Inoperable.Caused by Moisture Entrapment in System.Annunciator Response Procedure 0-RM-A-C-4 Was Performed
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) |
| 05000280/LER-1994-008, Forwards Corrected LER 94-008,changing Date to 940720 on Page 5 of 6,paragraph 5.0,line Four | Forwards Corrected LER 94-008,changing Date to 940720 on Page 5 of 6,paragraph 5.0,line Four | |
| 05000280/LER-1994-008-07, Corrected LER 94-0087-00,reflecting That Filter 3A Replaced & Returned to Service on 940720 Following Testing in Accordance W/Ts 4.12 | Corrected LER 94-0087-00,reflecting That Filter 3A Replaced & Returned to Service on 940720 Following Testing in Accordance W/Ts 4.12 | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) |
| 05000280/LER-1994-010, :on 940927,procedure 0-EPT-0109-03,weekly Emergency Diesel Generator Battery Pilot Cell & Bus Voltage Checks Had Not Been Performed.Caused by Personnel Error. Individuals Were Counseled |
- on 940927,procedure 0-EPT-0109-03,weekly Emergency Diesel Generator Battery Pilot Cell & Bus Voltage Checks Had Not Been Performed.Caused by Personnel Error. Individuals Were Counseled
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |