ML18144A951
| ML18144A951 | |
| Person / Time | |
|---|---|
| Site: | PROJ0728, 99902041 |
| Issue date: | 05/23/2018 |
| From: | Paul Clifford NRC/NRR/DSS |
| To: | Peters G Framatome |
| Rowley J | |
| Shared Package | |
| ML18129A020 | List: |
| References | |
| ANP-10340P, Rev. 0 | |
| Download: ML18144A951 (31) | |
Text
FINAL SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION TOPICAL REPORT ANP-10340P, REVISION 0, INCORPORATION OF CHROMIA-DOPED FUEL PROPERTIES IN AREVA APPROVED METHODS PROJECT NO. 99902041
1.0 INTRODUCTION AND BACKGROUND
By letter dated April 29, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16124B091), Framatome Inc. (Framatome, formerly AREVA Inc.)
submitted for U.S. Nuclear Regulatory Commission (NRC) staff review and approval Topical Report (TR) ANP-10340P, Revision 0, Incorporation of Chromia-Doped Fuel Properties in AREVA Approved Methods (Reference 1). Framatome desires to introduce chromia-doped fuel pellets to Framatome boiling water reactor (BWR) fuel products to increase fuel reliability and operational flexibility. The scope of this TR focuses on relevant fuel material properties and in-core behavioral characteristics that are affected by the addition of chromia to the uranium dioxide (UO2) fuel. Material properties of the doped fuel such as melting, density, thermal expansion, thermal conductivity, grain size and grain strength, stored thermal energy, creep yield strength, elastic modulus, strain hardening coefficient and tangent modulus, plastic Poissons ratio, and swelling are treated using the RODEX4 thermal-mechanical code (Reference 2). Additionally, certain models are also included in the AURORA-B methodology to predict the dynamic response of BWR fuel during transient, postulated accident, and beyond design-basis accident (DBA) scenarios.
The TR describes the proposed introduction of chromia-doped fuel pellets into normal core reloads. A nominal value of ['''''''] weight parts per million (wppm) ([''''''] weight percent (wt %)) of chromia (Cr2O3) is to be introduced in a UO2 pellet. This safety evaluation (SE) refers only to the dopant concentration range detailed in Section 3.1.1 of this SE.
During this review, a regulatory audit was conducted (References 2 and 3). After conclusion of the audit, a round of request for additional information (RAI) questions were issued (Reference 4) and responses were received (Reference 5).
This SE is largely ordered parallel to the submitted TR. Section 2.0 covers the regulatory evaluation, Section 3.0 covers the technical evaluation, and makes up the bulk of the document.
Section 4.0 contains the limitations and conditions. Section 5.0 contains the conclusions.
References are found in Section 6.0. The technical evaluation includes material properties in Section 3.1, behavioral assessment in Section 3.2, the operating experience and qualification dataset in Section 3.3, qualification of RODEX4 in Section 3.4, qualification of AURORA-B in Section 3.5, license criteria in Section 3.6, and finally power maneuvering guidelines in Section 3.7.
Enclosure
2.0 REGULATORY EVALUATION
The NRC staff used the guidance in Standard Review Plan (SRP), NUREG-0800, Section 4.2, Fuel System Design, for the review of ANP-10340P, Revision 0. SRP Section 4.2 acceptance criteria are based on meeting the requirements of General Design Criteria (GDC) 10 of Appendix A of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Reactor Design.
GDC 10 states:
The reactor core and associated coolant, control, and protection systems shall be designed with the appropriate margin to assure that specified acceptable fuel design limits are not exceeded during any condition of normal operation, including the effects of anticipated operational occurrences.
In accordance with SRP Section 4.2, the objectives of the fuel system safety review are to provide assurance that:
- a. The fuel system is not damaged as a result of normal operation and anticipated operational occurrences (AOOs),
- b. Fuel system damage is never so severe as to prevent control rod insertion when it is required,
- c. The number of fuel rod failures is not underestimated for postulated accidents, and
- d. Coolability is always maintained.
The NRC staff reviewed ANP-10340P, Revision 0 to: (1) ensure that the material properties and in-core behavioral characteristics of chromia-doped fuel, as analyzed using the RODEX4 and AURORA-B codes, are capable of accurately (or conservatively) ensuring the fuel system safety criteria, (2) identify any limitations on the behavioral characteristics of the additive fuel, and (3) ensure compliance of fuel design criteria with licensing requirements of fuel designs.
3.0 TECHNICAL EVALUATION
3.1 Chromia-doped Fuel Material Properties The chromia-doped fuel material properties are addressed in this section. These properties are used in RODEX4 and AURORA-B and describe behavior during normal operation, AOOs, and accidents.
3.1.1 Microstructure While not a material property itself, microstructure can have an effect on other properties of the fuel. The primary effect of chromia doping on microstructure is the enhancement of the fuel grain size. This enhances the viscoplasticity of the fuel and has an effect on the fission gas release (FGR) from the fuel. The chromia concentration ([''''''] wppm) has been selected such that the chromia is [' '' ''''''''''''''''' '''''' '' ''' ''''''''''''''''' ''''''''''''''''' ''''''''''''''''''''']. This leads to an average grain size of [' '' ''''''''''''''''''' ''''''' '''''''' ''''''' ''''''''''''''' ''''''']. This is ['''''
''''''' ''''''''' ''''''''] than standard UO2.
The NRC staff asked RAI-1a, which asked for clarification on manufacturing specification limits on chromia content as well as Framatomes quality assurance procedure to ensure the fuel produced is within those limits. Framatome responded that chromium content will be maintained within a range of [''''''' ''''''''''''''''''] microgram chromium per gram of uranium
(µgCr/gU) for each pellet lot. The nominal value corresponds with ['''''''] wppm of Cr2O3 as defined in the TR. Framatome will use Inductively Coupled Plasma-Mass Spectrometry to analyze chromia content, and sample several individual pellets in each lot.
The NRC staff finds the response to RAI-1a acceptable. The manufacturing tolerances will be included in the conditions and limitations in Section 4.0 of this SE.
3.1.2 Theoretical Density In the original TR submittal (Reference 1), Framatome stated that chromium mostly occupies interstitial positions in the UO2 ceramic matrix, and provided equations for determining the theoretical density of the doped fuel. Details of this section were discussed at the regulatory audit, and RAI-2 was asked to address remaining questions. RAI-2a requested clarification on the description of the location of the added chromium ions within the uranium sub-lattice.
Framatome clarified that the chromium (Cr) is primarily a ['''''''''''''''''''''''''' ''''''''''], and has amended the description in the TR accordingly. (Amended pages are included with the RAI responses in Reference 5). The NRC finds this explanation acceptable.
RAI-2b requested clarification on the method for calculating theoretical density of chromia-doped fuel, given the changing explanation of lattice location expected in response to RAI-2a. Framatome responded that the method of calculation is appropriate independent of the location of the dopant in the uranium sub-lattice. As this method has been previously approved for use with gadolinia dopants in RODEX4, the NRC finds this explanation, and the method for calculating theoretical density, to be acceptable.
RAI-2c noted a typographical error in equation 4-4. Framatome has corrected the error.
RAI-3 requested clarification on the statement that the stoichiometry of doped and standard UO2 is similar, and requested information on any impact on the fuel properties due to any difference in stoichiometry. Framatome responded that doped and standard UO2 have the same manufacturing specifications for stoichiometry. Framatome states that, as there are no significant differences in oxygen to uranium ratio between standard and doped fuel, there are also no differences in fuel properties as a result of stoichiometry. The NRC staff finds this response to be acceptable.
3.1.3 Thermal Expansion Thermal expansion of the fuel pellet is important primarily to the determination of the pellet-clad gap, which has a large effect on heat transfer. As UO2 thermal expansion has been shown to experience only minor changes with much higher levels of impurities, Framatome states that the small percentage of chromia added will have a negligible effect on the thermal expansion of the fuel. Therefore, Framatome will be using the thermal expansion coefficient for standard UO2.
The NRC staff finds Framatomes treatment of thermal expansion to be acceptable.
RAI-6 was asked to clarify a point in this section of the TR, which stated that the chromia level was in the range of impurity content in the fuel pellet. Framatome clarified that the statement was in reference to the total impurity limit, rather than a statement that chromia could be treated as an impurity. The NRC staff finds the explanation acceptable.
3.1.4 Specific Heat and Enthalpy Specific heat is a property used in the calculation of fuel stored energy during transients. It is also used in the calculation of thermal conductivity.
Framatome states that the specific heat of un-irradiated UO2 and chromia-doped fuel was measured using differential scanning calorimetry, with an estimated uncertainty of 7 percent.
The results of this measurement show that the doped fuel experiences a small increase in specific heat. Framatome has stated that this difference is negligible and the doped fuel will be analyzed using the same specific heat formulation as un-doped UO2. This result has been extrapolated to higher temperatures [''''' '''''''''''''''''''''''''''''' '''] as well.
The NRC finds this treatment of specific heat to be acceptable based on the experimental evidence provided and the theoretical explanation for extrapolating this data.
3.1.5 Thermal Conductivity Fuel thermal conductivity is essential to the modeling of both steady state and transient phenomena, as it directly impacts fuel temperature and stored energy. Generally speaking, higher thermal conductivity results in lower fuel temperatures and less stored energy in the fuel.
Framatome states that laser flash diffusivity measurements were performed on chromia-doped UO2 and gadolinia fuels as well as standard UO2. These tests subject a thin disc specimen to a high-intensity, short duration radiant energy pulse. This energy is absorbed by one side of the specimen, and the subsequent temperature rise over time is measured on the opposite side.
From these results thermal diffusivity can be calculated. Thermal conductivity is then simply the product of thermal diffusivity and volumetric heat capacity.
Framatome conducted two in-house thermal diffusivity measurement campaigns, one each in 2006 and 2015. In both cases Framatome also sent a sub-set of samples to the Joint Research Center-Institute for Transuranium Elements (JRC-ITU) for confirmation and complementary measurements. [''''''''''' '''''' '''''''''''''' ''''' ''''''''''' ''''' ''''''''''''' ''''''''' ''''''''''''''' ''''''''''''
''''''''''''''''''' ''''' ' '''''''''''''''' '''''''''''''''''''''' ']
The thermal conductivity correlation developed for chromia-doped fuel is discussed in Section 3.4.1 in the context of qualification of RODEX4.
3.1.6 Grain Size and Growth
Increased grain size drives many of the property and behavior differences between standard and chromia-doped fuel. As grain size is an input into many properties calculated in RODEX4, NRC staff asked RAI-1b: Please define the manufacturing specification limits on grain size, and describe AREVAs quality assurance procedures to ensure that the fuel produced remains within these limits.
Framatome responded by stating that the specification for chromia-doped pellets indicates a
['''''''''''''''''''''' '''''''' ''''''''''''''''''' ''''' '''''''''' '' ''' '''''''' ]. This is consistent with the grain size data that has been previously collected. Framatome will sample pellets to calculate the 95 percent LCL value and update the RODEX4 input distribution annually, as described in the RODEX4 TR. As the NRC has previously approved this approach, this is found to be acceptable for use with chromia-doped fuel.
Framatome states that grain growth is not expected due to the already-large grain size present in doped UO2. [''''' ''' '''''''' ''''''''''''''''''''' ' '''''' '''''' ''''''''''''''''''''''''''''''''' '''''''''''''''' '''''
'''''''''''''''''']. Given the evidence provided that ['''''' ''''' ' ''''''''''''''''''' ''''''''''''''''''' '''''''''''
'''''''''''''''''''''], the NRC finds this acceptable.
3.1.7 Elastic Moduli Elastic Moduli can impact cladding strain analyses for AOO events; however, Framatome states that the elastic properties of the fuel are not of fundamental importance to predicting fuel behavior under normal operation or abnormal conditions (such as AOOs or accident conditions).
Framatome refers to literature to indicate that additives cause only a minor change to these properties, with a significant addition (10-20 wt%) of gadolinium or plutonium resulting in a small change to Youngs Modulus, and no change in Poissons ratio. Given the much smaller percentage of chromia, Framatome states that they will continue to use the models for standard UO2 for these properties. The NRC staff has reviewed this justification and finds it acceptable.
3.1.8 Tensile Fracture Strength Tensile fracture strength is important to understanding the fuel pellet cracking behavior under thermal stress. This is effected by fuel porosity, pore size, and grain size. Un-irradiated fuels testing were performed by Framatome [''''''''' ''''''''''''''''''''' ''''''''''''''' '''''' ''''' '''''''''' ''''''''
' '''''' ''] These differences are accounted for by the increased grain size of the doped fuel. As these results are consistent with expected behavior, and contribute to pellet cladding interaction (PCI) performance benefits, the NRC staff finds Framatomes treatment of tensile fracture strength acceptable.
3.1.9 Creep and Plastic Deformation Creep and plastic deformation are important material properties for understanding fuel behavior under compressive stress. This stress occurs later in life, when the fuel pellet and cladding are in contact due to a combination of clad creep-down and fuel pellet swelling. Increased creep rate and plastic deformation of the fuel allow the pellet to adjust to these stresses without
damaging the clad, leading to reduced occurrence of pellet-clad mechanical interaction (PCMI) fuel damage.
Framatome states that uniaxial mechanical compression tests were performed to assess creep and plastic deformation of chromia-doped fuel. [''''''''' ''''' ''''''''''''''''''' ''''''' ''''''''' '''''
'''''' ''''''''' '''''''''''''' '''''' ''''''''''' ''''' ''''''''''''''''''' '''''''' ''''''''] Given the experimental data presented, the NRC staff finds the treatment of creep and plastic deformation to be acceptable.
3.1.10 Fuel Pellet Cracking Accurate understanding of fuel pellet cracking behavior is important to the prediction of fuel pellet deformation and PCMI. Fuel pellets crack radially due to thermal stresses. Framatome states that at the beginning of life the power must exceed ['' '' ''''''''' '''' '''''''''''''''''''] to initiate radial cracking.
While chromia-doped fuel has a different tensile strength, as described in Section 3.1.8 of this SE, the cracking mechanism for doped and standard UO2 fuel during steady-state operation appears fundamentally the same. The chromia-doped fuel does, however, behave differently under power ramp conditions.
['''''''''''''''''''' ''''''''' ''''' '''''''''''''''''' '''''''''''''''''''''''' '''''''''''''' ''' '''''''''''''''''''''''''' ''' '''''''''' ''''''''''''''
'''''' ' '' '''''''''''''' ''''' ' ''''''''' ''''''''''''''''''''''''' ']
The NRC staff finds the treatment of fuel pellet cracking under steady state power ramp conditions to be acceptable.
3.1.11 In-reactor Densification When first irradiated, UO2 fuel undergoes a densification process due to a combination of increased temperature and the fission process. This densification is important to the calculation of the fuel pellet diameter, and therefore the fuel-to-cladding gap. This densification is a result of a reduction in micron-scale pores. In-reactor densification is commonly simulated using out-of-pile resinter tests, which also lead to a reduction of these small pores.
Framatome states that the chromia-doped fuel was tested using a 24-hour out-of-reactor thermal stability test at 1700 degrees Celsius (°C). Framatome states that the fuel is ['''''
''''''''''''''''' ''' '''''''''''''''''''''' '''''''''''' ' '' ''''''' ' '''''''''''''''' '''' ''''''''''']
The NRC staff finds Framatomes treatment of in-reactor densification to be acceptable.
3.1.12 Effect of Additive on the High Burnup Fuel Pellet Rim Structure Irradiation of fuel to high burnup results in changes to the structure of UO2 pellets. These changes begin when the local burnup exceeds approximately 60 gigawatt-days per metric ton of uranium (GWd/MTU) and occur in the lower temperature region or near the periphery of the pellet and result in a structure known as the high burnup structure (HBS) or rim structure.
Formation of the HBS is attributed to recrystallization which starts at grain boundaries and propagates into the affected grains and to the formation of small pores on and within grains.
RAI-14 asked for additional explanation and data regarding the formation of the HBS.
Framatome clarified that the post-irradiation examination (PIE) data used in the analysis provided in the TR was on chromia-doped fuel with a chromia concentration outside of the proposed specification range. Framatome was able to share additional data from a PIE performed on doped fuel that is more representative of the product Framatome intends to produce.
Data collected on standard UO2 HBS has a very large spread when plotted against burnup.
While large grain size should hinder the formation of the HBS, and this has been observed in some PIEs. Framatome states that the chromia-doped fuel examined is within this spread and, therefore, no changes to the HBS models are needed.
The NRC staff finds this explanation acceptable, as HBS data presented appear to be within the uncertainty of non-doped UO2. It is also noted that this treatment is likely conservative, but the quantity of data is insufficient to draw further conclusions.
3.2 Behavioral Assessment The use of chromia-doped fuel could potentially impact the following in-reactor fuel behaviors:
fuel washout as a result of fuel clad failure, lower fuel melting limits, and performance during loss-of-coolant accidents (LOCAs) and reactivity initiated accidents (RIAs).
3.2.1 Washout Characteristics Washout behavior occurs after failure of the fuel cladding. Water is introduced into the fuel rod interior and interacts with the fuel pellet. In BWR conditions, water is mildly corrosive to UO2.
Corrosivity depends on multiple factors but primarily is dependent on the grain structure of the fuel.
Framatome used thermogravimetry to achieve a greater understanding of the underlying phenomena by measuring the mass change of unirradiated standard and chromia-doped fuel pellets with varied grain size in an oxidizing environment at 380 °C. This test indicated that the larger grain-size chromia-doped pellets experienced up to a 50 percent increase in oxidation resistance, while the small grain size chromia performed comparably to undoped UO2.
A second study was performed investigating corrosion behavior of unirradiated fuel in autoclave leaching tests under BWR conditions. These showed that the chromia-doped fuel ['''''''''''''''''''''''''
' ''''''''''''''' ' ''''''''''' '''''''''''''' ''''''' ''''' ''''] in comparison with undoped fuel.
Framatome states that this trend will remain valid in irradiated fuel.
The NRC staff finds that Framatome has provided sufficient evidence that chromia-doped fuel washout characteristics are bounded by undoped UO2, and therefore, finds Framatomes explanation to be acceptable.
3.2.2 Fuel Melting Framatome has measured the melting point of standard UO2, chromia-doped UO2, and chromia-doped (U-Gd)O2 fuel using laser heating and fast multi-channel pyrometry at JRC-ITU.
Framatome reported that the melting temperature for chromia-doped fuel is ['''''''''''''' '' ']
over the entire burnup range. Gadolia-doped fuel melting temperature [''''' '''''''''''''''''''' ' ''
'''''''''''' '''''''''''''']
The NRC staff asked RAI-4a to better understand if and how this ['''''''''''''] melting temperature was incorporated into RODEX4 and downstream safety analyses. Framtome responded that the melting point ['''''''''''''''] can be applied either within RODEX4 or as part of the post-processing of results. Framatome clarified that, while either approach is appropriate, RODEX4 has been updated to include the ['''''''''''''''] melting temperature for chromia-doped fuel. The NRC staff finds this explanation to be satisfactory. Framatome also clarified in this response that RODEX4s melting temperature model is not burnup dependent, but instead uses the expected minimum fuel melting temperature. By ['''''''''''''''' '''' '''''''''''''''''''''''''' ' ''], they are capturing the results from the JRC-ITU experiment. The NRC staff finds this acceptable.
RAI-4b asked for clarification on the statistical approach used by Framatome to calculate the
['''''''' ''''''' ''''''''''] for melting temperature from the JRC-ITU experiments. Framatome responded with a detailed description of their treatment of uncertainty for these experiments.
Uncertainty is a result of data dispersion, uncertainty in the emissivity of the fuel sample, and pyrometer calibration. These have been geometrically combined and adjusted for sample size to determine one-sided 95/95 values. The NRC staff agrees with this approach and finds it to be acceptable as it accounts for uncertainties appropriately.
3.2.3 Doped Neutron-Absorber Fuel Rods Framatome is also requesting approval of chromia-doped neutron-absorber fuel (NAF). NAF is UO2 with gadolinia dopant added, and is alternatively referred to as gadolinia-doped fuel.
Framatome included data collected for chromia-doped NAF thermal conductivity and melting temperature, which the NRC staff reviewed and found acceptable.
RAI-11 asked Framtome to disposition the remaining properties for chromia-doped NAF; a summary of the response follows:
- Microstructure and grain size are relatively unchanged between normal NAF and chromia-doped NAF, as the effect of the much larger quantity of gadolinia dopant exceeds that of the chromia.
- In-reactor densification is assessed during fabrication, and behaves the same as normal NAF
- Creep behavior was assessed for chromia-doped gadolinia fuel. This test found the samples to fall on a logarithmic curve. The creep rate for the chromia-doped NAF falls between the creep rates for standard UO2 and chromia-doped UO2.
- Washout behavior of chromia-doped NAF was studied in autoclave experiments under BWR conditions. Doped NAF fuel performs ['''''''''' '''''''''] at 290 °C, and shows] at 290
((°C, and shows [''''''''''''''''''' ''''''''''''''' ''''' '''''''''''''] at 360 °C.
- NAF is more resistant to PCI than UO2. This is not expected to change with chromia doping.
- The remaining properties included in the RIA (tensile fracture strength, fuel pellet cracking, HBS formation, performance under LOCA, and performance under RIA) are expected to be equivalent to un-doped NAF fuel.
Due to the evidence and theoretical arguments provided, the NRC staff finds the use of undoped NAF properties to be acceptable for analysis of chromia-doped NAF.
3.2.4 Behavior During Accident Conditions 3.2.4.1 Loss-of-Coolant Accidents The performance of the emergency core cooling system is judged relative to the performance of the reactor fuel under postulated LOCA conditions. 10 CFR 50.46 and Appendix K provide analytical requirements and prescriptive limits (e.g., 2200 degrees Fahrenheit (°F) peak cladding temperature (PCT), 17 percent ECR maximum cladding oxidation (MLO)) applicable to UO2 fuel pellets within cylindrical zircaloy or ZILRO cladding. These analytical limits preserve a coolable rod bundle array by ensuring adequate post-quench cladding ductility. The introduction of chromia-doped fuel pellets does not directly alter the applicability of the 10 CFR 50.46 analytical requirements and prescriptive limits associated with maintaining adequate cladding ductility; however, changes in fuel properties and performance may alter the accident progression and influence PCT and MLO calculation. In addition to 10 CFR 50.46, fuel performance may impact the LOCA radiological consequence assessment (often bounded by the maximum hypothetical accident). The following fuel properties and performance metrics were evaluated with respect to chromia-doped fuel:
- Fuel thermal conductivity and stored energy
- Fission gas release, rod internal pressure, and rod ballooning
- Fuel-to-cladding bond layer and oxygen ingress
- Fuel pellet fragmentation, relocation, and dispersal
- Fission gas release and accident source term A change in fuel thermal conductivity will impact the amount of stored energy in the fuel pellet.
Section 4.5 of ANP-10340P describes the impact of chromia addition on fuel thermal conductivity and Section 7.1 describes changes in the RODEX4 thermal conductivity model.
See Section 3.4.1 of this SE for further assessment of fuel thermal conductivity. In general, the addition of chromia reduces fuel thermal conductivity which tends to increase fuel stored energy. This potential impact is being explicitly addressed in the RODEX4 calculated stored energy and initial fuel conditions (input) to the downstream LOCA calculations.
A change in FGR will impact rod internal pressure which, in turn, will impact the probability of fuel rod ballooning and rupture. Section 7.2 of ANP-10340P describes the validation of the RODEX4 FGR model for chromia-doped fuel. See Section 3.4.2 of this SE for further assessment of FGR. In general, the addition of chromia increases the grain size which increases the diffusion path; however, the lower thermal conductivity tends to increase the rate
of diffusion. An increase in FGR would lead to higher rod internal pressures and increase the likelihood of fuel rod ballooning and rupture. These potential impacts are being explicitly addressed in the RODEX4 initial fuel conditions (input) to the downstream LOCA calculations.
The 10 CFR 50.46c rulemaking identified a new cladding degradation mechanism involving oxygen ingress from the fuel-to-cladding bonding layer, which reduces the time-at-temperature to nil ductility. A change in fuel irradiation swelling or pellet microstructure, which impacts the formation of the fuel-to-cladding bond layer, may change the timing (BU) at which point 2-sided oxidation must be considered. As 10 CFR 50.46c has not been finalized, this potential effect will not be considered in this SE.
A change in pellet microstructure or fission gas retention may impact the susceptibility to fuel fragmentation or the resulting fragmentation size distribution. Section 5.3.1 of ANP-10340P describes impact of chromia addition to fuel fragmentation under LOCA conditions. Citing a technical paper presented at TopFuel 2013, Framatome states that the susceptibility to fine fragmentation is highly correlated to the formation of the high burnup structure (HBS).
Framatome concludes that (1) pellet cracking pattern, (2) fuel-to-cladding interface bonding, and (3) HBS formation and evolution are comparable to that of UO2.
RAI-12 requested supporting evidence for the statement in the TR that cracking and pellet-clad interface behavior in chromia-doped pellets is very similar to that in standard UO2. Framatome provided data from the post-irradiation annealing test for standard and chromia-doped pellets, conducted by the Nuclear Fuel Industry Research (NFIR) Program from various fuel types irradiated in IFA-649 at the Halden Reactor Project (Halden). The data provided supports the conclusion that chromia-doped and standard UO2 behavior is similar. Therefore, the NRC staff finds the treatment of pellet cracking and pellet-clad interface to be acceptable.
Any interaction between chromia dopant and fission products may alter the amount or chemical species of releases during Design Basis Accidents or Severe Accidents. While Framatome did not include a discussion in the TR, the source term released from the fuel during postulated accidents was questioned in RAI-13. Framatome responded that the dopant does not modify the isotope inventories. Given this and the negligible impact on neutron flux-spectrum, Framatome plans to use NUREG-1465 to determine the alternate source term (AST) for chromia-doped fuel as it does undoped UO2. The NRC staff finds Framtomes treatment of AST acceptable.
3.2.4.2 Reactivity Initiated Accidents The regulation at 10 CFR Part 50, Appendix A, GDC 28 requires reactivity control systems to be designed with appropriate limits on potential amount and rate of reactivity increase to assure that the effects of postulated reactivity accidents can neither (1) result in damage to the reactor coolant pressure boundary greater than local yielding nor (2) sufficiently disturb the core, its support structures, or other reactor pressure vessel internals to impair significantly the capability to cool the core. For BWRs, the postulated control rod drop accident (CRDA) is the limiting RIA.
The following fuel properties and performance metrics were evaluated with respect to chromia-doped fuel:
- Control blade worth and reactor kinetics
- Fuel transient thermal expansion and gaseous swelling
- Fuel melting temperature
- Fission gas release, rod internal pressure, and rod ballooning
- Fuel pellet fragmentation, relocation, and dispersal
- Transient fission gas release and accident source term Section 9.3 of ANP-10340P describes the impact of chromia addition to nuclear design requirements and reactor kinetics. There is no impact on reactor physics calculations because chromium and oxygen cross sections are included in the nuclear data library of the CASM0-4 lattice code. Additions of chromia to the fuel will require no changes to existing neutronics codes or methodologies. Hence, any impact of chromia addition on core physics predictions will be explicitly accounted for.
Section 7.3 of ANP-10340P describes the new RODEX4 intraganular gaseous swelling model.
PIE data on chromia-doped fuel rods show larger cladding deformation following both steady-state and power ramp irradiations, which indicates an increased fuel pellet deformation in comparison to standard fuel. Measured cladding strain was used to validate the new RODEX4 model. Section 5.3.2 of ANP-10340P describes the potential impact of chromia addition on fuel performance under RIA conditions. Framatome states that ['''' ''''''''''''''''
''''''''' ''''''''''''''' '''' '' '''''''''''''' '''''''''''''''''''''' '''' ''''''' ''''''''' '''''''''''''''' '' ''''''' '' ''''' ].
RAI-7b and RAI-7c requested additional evidence on fuel swelling and fragmentation, respectively. The RAIs also suggested the Nuclear Safety Research Reactor (NSRR) as a possible source for RIA performance data on fuel pellets different than standard UO2. As no data from NSRR exists for chromia-doped fuel, Framatome discussed performance of other fuels with similar properties, such as gadolinia doped, large-grain undoped, and niobia-doped fuel, which has similar intragranular swelling features. Framatome states that all of these tests showed similar outcome during RIA pulse testing as standard UO2, and assert that gadolinia doped fuel is bounding, and as gadolinia fuel is included in DG-1327, it is expected that the draft guide would be similarly applicable to chromia-doped fuel.
Similarly, Framatome states that niobia-doped fuel should bound the fuel fragmentation performance of chromia-doped fuel, as the intragranular gaseous swelling is larger for niobia doped fuel. They further point to NFIR post-irradiation annealing tests that indicate that FGR is lower for doped fuel than standard UO2. This test also found that fuel fragment size was a factor of burnup, but that no fine-fragmentation was found during the anneal testing on any standard or doped UO2, nor mixed oxide (MOX), between 40 and 48 GWd/tHM. Framatome asserts that the fission gas residing within the grains in intragranular bubbles will decrease the FGR during RIA, as fission gas reaches the gap primarily through a process of cracking along the grain boundary.
The Organization for Economic Co-operation and Development/Nuclear Energy Agency (OECD/NEA) State-of-the-Art report, Nuclear Fuel Behaviour Under Reactivity-initiated Accident (RIA) Conditions, make the following observation (Section A.5.1.4) (Reference 6) with respect to fuel grain size on RIA fuel performance:
It should be remarked that rod OI-10 showed exceptionally low fission gas release and cladding residual deformation. From the peak fuel enthalpy in this test, it is expected that film-boiling occurred during the transient ['''']. Yet, the cladding peak residual hoop strain is merely 0.7%, and the transient fission gas release is only 2.6%. These unusually low values are probably a consequence of the large grain (~28 m) UO2 fuel that was used in the OI-10 test rod. Due to
the large grain size, there is less fission gas accumulated in grain boundary bubbles, and the transient fission gas release is lower than from fuel pellets with normal grain size (~10 m).
This observation supports Framatomes claim regarding less transient FGR under RIA conditions.
After review of the additional information submitted by Framatome, the NRC staff finds the description of chromia-doped fuels RIA performance, from the standpoints of fuel pellet swelling and fragmentation to be acceptable.
A change in fuel melting temperature may impact the allowable amount of deposited energy (coolability criterion), predicted number of failed fuel rods, and radiological source term.
Section 5.2 of ANP-10340P describes the impact of chromia addition on fuel melting temperature. In general, the addition of chromia [''''''''''' ''''''''''''] the fuel melting temperature.
Changes were experimentally determined and will be explicitly accounted for in the approved methodology. With respect to fuel performance under RIA conditions, Section 5.3.2 of ANP-10340P concludes that the limited amount of chromia will not induce significant changes in fuel specific heat, thermal conductivity, or fuel melting point. As such, the radial average fuel enthalpy threshold for incipient melting of chromia-doped fuel is not significantly different than standard UO2 fuel.
RAI-7a requested clarification of a statement made in the TR which indicated that the change in margin to fuel melt is negligible between doped and standard UO2. Framatome was asked to explain how the changes to fuel conductivity and melting point would affect allowable peak radial average fuel enthalpy and predicted number of fuel rod failures due to fuel melt.
Framatome responded by stating that thermal-mechanical and thermal-hydraulic methodologies calculated each reload cycle would both include the new properties, and therefore any change to the average fuel enthalpy threshold for incipient melting would be explicitly accounted for.
They additionally pointed to the example calculation provided in ANP-10340P, which indicated that there is generally a minimal impact to margin to fuel melt. The NRC staff finds the explicit calculation of fuel melt margin using the new thermal conductivity and melting temperature to be acceptable.
During the regulatory audit, Framatome indicated that, under certain conditions, chromium
['''''''''''' '' ''''''''' '' ''''''''] through some other process, and [''''''''''''''''' '''''''''''' '' '''''''''''
''''''''' ''''''''''''''''' ''''''''''' ''''''''''''''''''''''']. The NRC staff asked RAI-5 to gather additional information and understanding of this behavior. This discussion is included in this section of the SE, as fuel centerline temperature is seen as the primary driver of the phenomenon, and RIA results in increased fuel centerline temperature.
Framatome described the solubility of chromia and other chromium species inside the pellet qualitatively as a function of temperature and burnup. In response to RAI-5a, which requested a description of the change in chromia content in the pellet with increased temperature, Framatome stated that:
During power ramps, some chromia will reduce, causing the liberation of oxygen.
This oxygen is expected to migrate to oxidize the inside of the cladding, which has the effect of counteracting stress corrosion cracking (SCC). The chromium remaining in the pellet is converted to a metallic precipitate, and it is expected that this would restore the thermal conductivity to that of undoped UO2.
In response to RAI-5b, which requested any data from hot-cell examinations that would confirm this behavior, Framatome described the change in ['''''''''''''' ''''''''] in the pellet center, and showed x-ray cartography data that provides experimental evidence for this behavior.
In response to RAI-5c, which asked if chromia migration might lead to an increase FGR, Framatome clarified that the chromium does not leave the [''''''''' '''''''''], and thus would not precipitate in such a way to negatively impact FGR, but rather that the oxygen may migrate under certain conditions.
The NRC staff has reviewed these responses, and the data contained within, and find them to be acceptable.
A change in FGR will impact rod internal pressure which, in turn, will impact the probability of fuel rod ballooning and rupture. Section 7.2 of ANP-10340P describes the validation of the RODEX4 FGR model for chromia-doped fuel. See Section 3.4.2 of this SE for further assessment of FGR. In general, the addition of chromia increases the grain size which increases the diffusion path; however, the lower thermal conductivity tends to increase the rate of diffusion. An increase in FGR would lead to higher rod internal pressures and increase the likelihood of fuel rod ballooning and rupture. These potential impacts are being explicitly addressed in the RODEX4 initial fuel conditions (input) to downstream safety analyses, including RIA calculations.
A change in pellet microstructure or fission gas retention may impact the susceptibility to fuel fragmentation or the resulting fragmentation size distribution. Section 5.3.2 of ANP-10340P describes the potential impact of chromia addition to fuel fragmentation under RIA conditions.
Citing microstructural examinations of irradiated fuel, Framatome concludes that chromia-doped fuel has a [''''''''' ''''''''''''''''''''''' ' '''' ''''''''''''''''''''''''''''' '''''''''' '''' '''''''''''''''''''].
Any interaction between chromia dopant and fission products may alter the amount or chemical species of releases under RIA conditions. Citing microstructural examinations of irradiated fuel, Framatome concludes that chromia-doped fuel has a [''''''' '''''''''''''''''''''''''''' ' ''''''''''''''' ''''''''''
''''''''''''''''' '''''''''''''''''''''''' '''''''] under RIA conditions. Additionally, in the response to RAI-7a, Framatome stated that the impact on source term due to a change in melting temperature will be taken into account when AST analyses are performed.
In a recent review of Global Nuclear Fuel-Americas, LLC additive fuel pellets for BWR applications, the NRC staff evaluated the impacts on fuel performance under RIA conditions.
Results presented from NSRR RIA tests on fuel rod segments with different additive compositions and concentrations exhibited similar behavior and failure thresholds as standard UO2 rods. These results support the discussion above which refers to tests with niobium-doped, gadolinia, large grain standard, and MOX fuel.
The RIA empirical database which forms the technical bases for the soon to be published regulatory guidance and acceptance criteria in DG-1327 is comprised of over 150 prompt pulse tests performed at several research reactors on a large variation of fuel rod designs, including non-standard UO2 fuel pellets. While no explicit RIA tests were conducted on chromia-doped fuel, tests conducted on other non-standard UO2 fuel strongly suggest that the concentrations of chromia requested in this TR (and the known impacts on fuel properties) are unlikely to significantly or negatively impact fuel performance under RIA conditions.
One potential unintended consequence of eliminating fuel designs with the natural or low alloy zirconium liner cladding (with the substitution of chromia-doped fuel) is the change in the initial, pre-transient cladding hydrogen distribution. The barrier liner acts as a sponge for hydrogen absorbed through waterside corrosion. The barrier effectively removes significant amounts of hydrogen and the detrimental effects of hydrides from the base metal. Out-of-pile mechanical testing on irradiated cladding segments suggest that the zirconium liner, even after significant irradiation and hydride precipitation, remains ductile. Since the presence of a barrier liner depletes hydrogen from the base metal and remains ductile, a barrier lined fuel rod will likely exhibit more ductility than a non-lined fuel rod at the same hydrogen level.
As a result of this phenomenon, a potential inconsistency exists with recrystallized annealed (RXA) Zry-2 cladding. A majority of the NSRR prompt power test results used to develop the PCMI cladding failure threshold for RXA cladding are based on RXA Zry-2 fuel rod segments with a zirconium liner. Application of these test results to RXA Zry-2 fuel rod designs without a liner may be non-conservative. Future applicants should carefully consider the applicability of these cladding failure curves to non-lined RXA Zry-2 fuel rod designs.
The NRC staff finds the performance of chromia-doped fuel under RIAs acceptable.
3.3 Operating Experience and Qualification Data Framatome has conducted ['] steady-state lead fuel assembly (LFA) campaigns in pressurized water reactor (PWR) and BWR reactors using chromia-doped UO2 fuel pellets, beginning in 1997. These have included enrichments up to 4.95 percent U235, and densities from ['' '' '''''''''''''' '''''''''''''''''''''' '''''''''']. Cladding for these pellets has included
[''''''''''''''''''''''''''' '' ''''' '''''''''''''''''''' ''''''''' ''''''''''''''' ''''''''''''''' '''''' ' '''''''''' ''''' '''''''''''''''''' '''
''''''''''''''''''''''''' '''''''''''' ''''''''' '''' '''''' '''' ''''''''''''''' ''''' ''''''''''' ''''' ''''''''''''''' '' '''''''''''].
Maximum rod burn-up of approximately [''''''''''''''' ''''''''''''''' ''' ''''''''''''' ' ''''''''''''''''
''''''''''''''''''''''] has been obtained. This includes a LFA program in a domestic BWR.
Rods irradiated as part of the LFA campaigns have been used for ramp testing, as described in Section 3.3.2 of this SE, and Section 6.2 of the TR. Framatome states that most of the ramped fuel rods were irradiated to burnup levels that are typically most limiting with respect to PCI failures. In addition, high-burnup rods were also tested, to assess the impact of hydrogen uptake.
3.3.1 Steady State Dataset The range of burnup achieved in commercial reactors at steady-state is summarized in Table 3.3-1 below, taken from the TR. These were irradiated in the following cladding materials:
['''''''' '''' ''''''''''''''''' '''''''''''''' '''''''''''''''''' ''''''''''''''''],
[''''''''' '''''''''''''''' '''''' ''''''' '''' '''''''''''''''']
Fuel rod designs included in the database are:
['''''''' '''''''''' '''' ''''''''],
[''''''''' '''''''''].
Following irradiation, PIE measurements of the following were conducted:
['''''''' '''' ''''''''''''''' '''''''''''''' '' '''''''''''''''''''''' '''''''' '''''''''''''''''''' ''''''' ''''' '''' '''''''''''' ''''
''''''''' ''''''''''].
Some rods were full-length, while others were rodlets used for ramp testing after base irradiation was achieved. [''''' '''''' '''''''''''''''''' ''''''''''''''' ' ''''''''''''''''''''''''''''''' '''' '' ' '''''''
'''''' ''''''' ''''' ' '''''''''''' ' ''''''' '''''].
Temperature measurements were also collected for separate effects testing of high burnup fuel
(~50 MWd/kgU). A rod that had accumulated burnup was refabricated and instrumented with a central thermocouple and irradiated in a test reactor with on-line temperature measurement.
['''''''''' ''''''''''''''''''''''' ''''''''''''''''''''''''''' '''''''''''''''' '' '''''''' '''''' '''''' '''''''''''''''''''''''''' '' ''''''' ''' '
''''''''].
Table 3.3-1 Chromia-doped irradiation database (from Reference 1)
3.3.2 Ramp Dataset The range of burnup achieved for the ramp dataset is summarized in Table 3.3-1, taken from the TR. The ramp dataset is used to justify the ramp rates discussed in Section 3.7 of this SE.
The following cladding materials were used in this dataset:
[''''''''' ''''' ''''''''''''''' ''''''''''''],
['''''''' ''''''''''''''' ''''''' '''''''' '''' ''''''''''''''']
Fuel rod designs included in the database are:
[''''''''' ''''''''''],
['''''''''' '''''''''].
Following irradiation, PIE measurements of the following were conducted:
[''''''' ''' '''''''''''''''' '''''''''''' '' ''''''''''''''''''''' '''''''' '''''' '''' ''''''''''''''' ''''' ''''''''' '''''''''''].
For the BWR program [''''''' ''''''' '''''' '''''''''''''''''''' ''''''''''' ' '''''''''''''''' ''''''''''' '''' '''''
''''''''''''' ' ''''''''''''''' ' '''''''''' '''''''''''''''' ''''''''''' ''''''' ''''''']
The NRC staff concludes that Framatome has provided sufficient operating experience for chromia-doped fuel for use within the bounds of the conditions and limitations included in this SE.
3.4 Qualification of RODEX4 RODEX4 is Framatomes fuel thermal-mechanical code approved for BWR fuel design and licensing analyses with standard UO2 and gadolinia-doped UO2. The following sections of this report detail changes made to RODEX4 to accommodate the properties and behavior of chromia-doped fuel.
Validation and verification of these changes was carried out by comparing the data described in Section 3.3 of this SE and Section 6 of the TR. This data includes [' '''''''''''''''''''''''''''
''''''''' ''''''''''''''''' '''' '''''''' ''''''''''''''''''''''].
3.4.1 Thermal Conductivity Model Thermal conductivity is measured experimentally by determining the thermal diffusivity and the specific heat capacity of the material. Thermal diffusivity measurements were taken during the JRC-ITU 1999 campaign, as well as in-house campaigns conducted by Framatome in 2006 and 2015. A subset of samples from these in-house campaigns was sent to JRC-ITU for
complementary measurements. Thermal conductivity is also described in Section 3.1.5 of this SE.
3.4.1.1 Adaptation of RODEX4 thermal conductivity model to unirradiated chromia-doped fuel JRC-ITU data used either measured specific heat, or a known specific heat correlation. As Framatome is not intending to modify the specific heat correlation used for standard UO2 and
['''''''''''''''''''''''''''''''' '''''] for use with chromia-doped fuel, the thermal conductivity of the samples was recalculated using the MATPRO correlation used in RODEX4. This change resulted in lower uncertainty and a better match with the data.
During the 2015 campaign Framatome tested a number of different chromia concentrations and found that conductivity decreases with increasing chromia concentration, ['' ''' '''''''''
''''''''''''''' '''''''''' ''''''' ''''''''' '''''''''' '' ''''''''''''''''' ''''' ' '''''''''''''''' ''''''].
Using this experimental data, a new thermal conductivity model was developed for chromia-doped fuel. This model is specified in the TR, Section 7.1.1 and ['''''''''''''' '''''''''''''
''''''''''' '''''''''''''']
3.4.1.2 Validation of RODEX4 thermal conductivity model to irradiated chromia-doped fuel Standard UO2 fuel experiences degradation of thermal conductivity with increased burnup. To validate that this effect is also present in chromia-doped fuel, Framatome benchmarked RODEX4 to the REMORA2 test, where a pellet centerline temperature was measured online using thermocouples after achieving a burnup of around 62 MWd/kgU. This showed good agreement when applying the same thermal conductivity degradation effect to chromia-doped fuel as is applied to standard UO2.
Due to the experimental measurements and satisfactory benchmarking of RODEX4, the NRC staff finds Framatomes thermal conductivity models for chromia-doped fuel and chromia-doped NAF to be acceptable.
3.4.2 Fission Gas Release Model Framatome states that the FGR model in RODEX4 remains unchanged. This is due to competing effects: larger grain size reduces FGR by slowing the diffusion to grain boundaries, but the reduction in grain boundary area leads to decreased fission gas retention at these boundaries. Framatome provides a plot of calculated versus measured FGR from a number of lead assemblies.
Framatome discounts the impact that chromia has on the diffusion rate of fission products through the fuel matrix. A plot is presented in the TR showing predicted versus measured FGR from a database of 48 doped samples and 13 undoped control samples paired with data in the doped set. These data show a relatively wide degree of variability, but generally are in agreement with the predicted values.
The NRC staff requested, in RAI-9, that Framatome model test IFA-716 from the Halden experimental reactor using RODEX4. This experiment measured FGR from chromia-doped fuel as well as standard and large-grain undoped UO2. Framatome submitted this as well as the results from modeling IFA-677, which was similar to IFA-716 but contained standard UO2 as well as fuel pellets with a different dopant. Tables 3.4-1 and 3.4-2 below summarize the important results from these test rods. For the purposes of evaluating the FGR in chromia-doped fuel, there are a total of 3 rods of interest containing standard UO2 (677-2, 677-6, 716-2), and 2 rods with chromia dopant (716-1 and 716-6). All of these rods except 716-2 had online FGR calculated from online rod internal pressure, and 677-6 and 716-6 both were also subjected to PIE FGR measurements using puncture testing.
RODEX4 very slightly overpredicted FGR for the two standard UO2 rods for which there is data.
The two chromia-doped rods, on the other hand, were underpredicted by the code. It is worth noting that the total FGR for these two rods is still small, where the standard UO2 has typically also had a relatively large spread of data.
The NRC staff also requested the data used to generate this plot in RAI-8a. This data was provided with additional information, such as grain size and chromia content, that was not in the original submittal. This data was examined to determine if any of the other parameters correlated with FGR calculational errors. No trends were found. Framatome also submitted a plot of FGR, replicated below, using the 95/95 bound for diffusion coefficient and LHGR. This additional plot provided assurance that the FGR dataset is representative of the doped fuel under review, and that the FGR correlation in RODEX 4 does a satisfactory job of predicting the experimental data. For these reasons, the NRC staff finds the FGR model acceptable for use with chromia-doped UO2.
Framatome also requested that the grain size restriction (for standard UO2) imposed by the SE for RODEX4 (Reference 7) be lifted. The primary stated reason for that restriction was the limited FGR data for undoped fuel with grain size above 20 µm MLI. To better disposition this request, the NRC staff requested additional FGR data to support the use of large-grain standard UO2 in RAI-10a, and requested that Framatome model a Halden test (Halden-716) which studied the behavior of both chromia-doped as well as large grain undoped UO2 fuel.
Framatomes response to RAI-10a provided a total of 9 data points for FGR from standard UO2 with grain size over 20 µm. Framatomes response to RAI-9 demonstrated underprediction of FGR from large grain undoped UO2.
The NRC staff has determined that this is insufficient evidence to warrant removing the restriction on grain size for standard UO2. Although this is not a new limitation or condition, for clarity this will be included in the limitations and conditions in Section 4 of this SE.
Table 3.4-1 Salient Features and Measured Data for Modelled rods of IFA 677 (From Reference 5, Table 9-1)
Table 3.4-2: Salient Features and Measured Data for Modelled rods of IFA 716 (From Reference 5, Table 9-2)
Figure 3.4-1: FGR Results for the Chromia-Doped Database with LHGR and Diffusion Coefficient Biased to the 95/95 Upper Bounds (From Reference 5, Figure 8-1) 3.4.3 Intragranular Gaseous Swelling Model In standard UO2, fission gases collect and may form bubbles along the grain boundary, known as intergranular bubbles. As chromia-doped fuel has larger grains and enhanced creep and plasticity it has a propensity for forming intragranular bubbles instead, as the gases collect inside the grain instead of along the grain boundary. These bubbles lead to increased fuel pellet and cladding deformation, especially following a power ramp.
To accurately capture this phenomenon, Framatome has added an intragranular swelling (IGSW) model to RODEX4. After using PIE ceramography to calibrate the parameters of this model, Framatome presented data showing good agreement between measured and calculated fuel clad strain from the chromia-doped fuel database. Given the validation data provided, NRC staff finds this model acceptable for modeling fission gas swelling in chromia-doped fuel.
During the regulatory audit, NRC staff asked if the intergranular model is turned off for chromia-doped fuel pellets. Framatome responded that the model reduces IGSW with increased grain size, and therefore does not need to be adjusted for chromia-doped fuel. The NRC staff finds this acceptable.
RAI-10b requested additional information regarding how the IGSW model will be applied to standard UO2. In response, Framatome states that the model is only used if the grain size exceeds [''] microns MLI. They also state that they would not expect standard UO2 to exceed that value.
In their response to this RAI Framatome demonstrated that, for standard UO2 below the 20 micron 3-D limit, including the IGSW model results in a small conservative change in the predicted strain increment during power ramps, a small change in the clad diameter change after steady-state irradiation, and a small non-conservative change in the FGR prediction. The NRC staff has reviewed this response and found it to be acceptable.
3.5 Qualification of AURORA-B Framatome states that AURORA-B will include the use of RODEX4 and S-RELAP5, and that the thermal conductivity model described in Section 3.4.1 of this SE will be incorporated into S-RELAP5.
The NRC staff finds this acceptable. This does not over-ride or replace any conditions or limitations placed on the use of AURORA-B methodologies by the NRC staff in other safety evaluations.
3.6 Licensing Criteria Assessment Framatome states that no fundamental changes are necessary in order to model chromia-doped fuel using RODEX4 or AURORA B methodologies, beyond changes to correlations discussed in Sections 1.0 and 8.0 of the TR, and covered in Sections 3.4 and 3.5 of this SE. Additionally, there is no change to any design or licensing criteria. Examples of the design analyses were performed with the chromia-doped option activated and the results of those analyses are discussed below.
These examples were examined in greater detail at the regulatory audit (References 2 and 3) conducted by NRC staff. No discrepancies were found.
3.6.1 Steady State and AOO Analyses Framatome repeated a recent ATRIUM 10XM reload steady-state calculation (performed with RODEX4) using the chromia-doped fuel model options activated, and the results were compared to the standard UO2 cases. The outcome of this comparison shows that, compared to standard UO2, chromia-doped fuel exhibits:
- [''''''''' '''' '''''''''''''''' ''''''''''''''''''''''''']
- [''''''''' '''''''''''''''''' ''''''''''''' '''''''''' '''''''''']
- [''''''''''''''''' '''''''''''' '''''''''''''''''''' '''''''''' ''''''''']
- [''''''''''''''' '''''''''''''''''''''''''' ''''''''''''']
[''''''''''''''''''''''''' '''''''' ''''''''' ''''' '''''''''''''''' '''' ''' '''''''''''''''' '''''''''''''''' '''' ''''' ''''''''''''''
''''''''''''''''''' ''' ''''''''''''''].
For the AOO analysis, Framatome calculated fast AOO setback factors for control rod withdrawal error, and flow run-up. Compared to standard UO2, chromia-doped fuel exhibits:
- ['''''''''''''''' ''''''''''' '' ''''''' '''''''''''''''''''''' '' '''''''''' ''' '''''''''''' '' ''''''' '''' ''''''''' '''''''
''''''''''']
- ['''''''''''''''''' ''''''''''' ''''''''''''' ' ''''''' ' ''''''''''' '''''''''''' '' ''''''''''''''' ''''''''''''''''' ''''''''''''
'''''''''' ' ''''''''''''''']
[''''''''''''''''''''''' ''''''''' '''' '' '''''''''''' ' '''''''' ''''''''''''''''''' ''''''''''''''''' ''''''''''' '''''''''''''].
The NRC staff has examined the results of this analysis presented in the TR, as well as the detailed calculations made available at the regulatory audit. The results are acceptable, as they demonstrate expected behavior.
3.6.2 Safety Analyses Framatome performed sample problems that cover AOOs, LOCA, and CRDA using AURORA-B. The AOO analysis performed with AURORA-B is separate from that performed with RODEX4, described in Section 3.6.1, and focuses primarily on thermal-hydraulic response rather than thermal-mechanical. The primary consequences of chromia-doped fuel over standard UO2, for these analyses, are competing effects on energy stored in the fuel. On one hand, doped fuel closes the gap between the cladding and the pellet earlier, which results in lower thermal resistance between fuel and coolant. On the other hand, decreased fuel thermal conductivity has the opposite effect.
Framatome provided results for three AOOs: turbine trip-no bypass (TTNB), feedwater controller failure (FWCF), and anticipated transient without scram. Different figures of merit are of primary interest for different AOOs. For TTNB and FWCF, margin to boiling crisis (i.e., critical power ratio, or CPR) are of interest. As margin is reduced with increase thermal conductivity, the upper bound best estimate thermal conductivity correlation, described in Section 3.4.1.1 of this SE, was used to ensure conservatism. Framatome presents the results of these calculations in Table 9-4 of the TR, which indicates that, for these example calculations, chromia-doped fuel exhibits only small changes to CPR and maximum system pressure for these three transients.
For the remaining sample problems (large-break LOCA, small-break LOCA, and CRDA), the figure of merit is PCT. The results show that the doped fuel has very little effect on the results of the calculation, with only a very small increase in PCT, explained by a small increase in stored energy.
3.6.3 Impact on Nuclear Design Requirements Framatome states that there is no impact on reactor physics calculations as cross sections for Cr and O are included in the CASMO-4 lattice code. Framatome further states that the change in reactivity is small, as the absorption cross section for chromium is small compared to that of the fuel and the small change of density is properly captured. Thus changes are small and will be captured by current analysis methods. The NRC staff finds this acceptable.
3.7 Power Maneuvering Guidelines The movement of high worth control blades during BWR power maneuvering may result in a significant increase in local power. Depending on the initial pellet-to-clad gap width, fuel pellet thermal expansion may lead to an increase in cladding stress. Given the right combination of mechanical stress, chemical agent (e.g., iodine), and time, pellet cladding interaction - stress corrosion cracking (PCI-SCC) induced crack propagation may lead to cladding failure.
PCI-SCC cladding failures during power maneuvering were a significant operational issue prior to the introduction of liner cladding (i.e., thin layer of natural or low alloy zirconium on cladding inside diameter) in combination with power maneuvering guidelines.
The regulation at 10 CFR Part 50 Appendix A GDC 10, Reactor design, requires that the reactor core and associated coolant, control, and protection systems shall be designed with appropriate margin to assure that specified acceptable fuel design limits are not exceeded during any condition of normal operation, including the effects of AOOs. In accordance with GDC 10, licensees should establish power maneuvering guidelines, based upon experimental data, which minimize the likelihood of fuel rod cladding failures. However, recognizing the low safety significance of a limited number of fuel rod failures, existing plant technical specification allowable limits on reactor coolant activity, and the ability of plant operators to identify and respond to fuel rod failures during power maneuvering, the NRC staff does not require specified, reviewed, and approved power maneuvering restrictions.
Section 10.2 of ANP-10340P describes ramp testing performed on irradiated chromia-doped UO2 fuel rod segments. The purpose of these ramp tests was to quantify the PCI-SCC performance of chromia-doped UO2 fuel and demonstrate it as an alternative to present liner cladding in terms of PCI-SCC protection for BWR applications. Figure 10-1 of ANP-10340P (reproduced below in Figure 3.7-1) provides the Framatome ramp test database as a function of conditioning power versus power increment. Further details were provided in response to RAI 8b (Reference 5).
Fuel rod design (e.g., rod diameter, initial gap size, cladding thickness, cladding microstructure) and operating history (e.g., power history, burnup, cladding corrosion) play an important role in quantifying PCI-SCC resistance and defining power maneuvering guidelines. Figure 3.7-2 illustrates the extent of the Framatome ramp test database for BWR fuel designs with chromia-doped fuel as a function of conditioning power and separately as a function of fuel burnup. The database is limited both in the total number of ramp tests (14), the number which experienced cladding failure (4), and the range of conditioning power and burnup.
To investigate Framatomes claim that chromia-doped UO2 fuel is a viable alternate to liner cladding in terms of PCI-SCC protection, the NRC staff reviewed the Studsvik Cladding Integrity Program (SCIP-I, SCIP-II) ramp testing empirical database. With over 180 ramp tests conducted on BWR fuel rods with liner cladding, the SCIP database encompasses a much
broader range of initial and test conditions. Figure 3.7-3 plots the SCIP test results along with the Framatome BWR database (failed versus survived as a function of conditioning power and power increment). The transition between failure and survival as a function of conditioning power is similar between chromia-doped fuel and liner cladding and certainly within the spread of the SCIP database.
Figure 3.7-4 plots only the tests which experienced cladding failure. Hundreds of earlier SCIP ramp tests with standard Zry-2 BWR cladding (unlined) have been added to investigate the relative benefit of both chromia-doped and liner cladding. Examination of this figure reveals significant improvements in PCI-SCC resistance for both chromia-doped and liner cladding, especially at higher conditioning powers.
Figure 3.7-5 adds the cladding liner fuel rod failure threshold and proposed chromia-doped fuel rod failure threshold to the SCIP and Framatome database depicted earlier in Figure 3.7-3.
Based on the limited chromia-doped ramp database and the spread in the broader SCIP BWR liner cladding database, the NRC staff is not convinced that the chromia-doped fuel offer superior PCI-SCC resistance relative to liner cladding. Both chromia-doped fuel and liner cladding exhibit significant improvements in PCI-SCC resistance relative to non-liner BWR cladding designs. As such, chromia-doped fuel is a viable alternate to liner cladding.
Licensees and their fuel vendors are responsible for establishing power maneuvering guidelines, which when combined with the beneficial PCI-SCC performance of either chromia-doped or barrier liner, provide a reasonable assurance of fuel rod cladding integrity during power maneuvering.
Figure 3.7-1:
Figure 3.7-2:
Figure 3.7-3:
Figure 3.7-4:
Figure 3.7-5:
4.0 LIMITATIONS AND CONDITIONS
- 1. The limitation imposed on grain size of standard UO2 in the RODEX4 TR SE (Reference 7) is unchanged.
- 2. Chromia-doped fuel is licensed to the same currently approved rod-average burnup limit as standard UO2: 62 GWd/MTU.
- 3. Chromia concentration shall be limited to the range specified in the response to RAI-1a:
['''''' ''''''''''''''''''] µgCr/gU. This limit shall also apply to chromia-doped NAF.
5.0 CONCLUSION
S Framatome has presented data and analyses to support their request for approval of chromia-doped UO2 fuel for use in BWRs, where the dopant is within the range ['''''''
''''''''''''''''''] µgCr/gU. Material property changes have been implemented in both the RODEX-4 thermal-mechanical code and the AURORA-B transient analysis methodology. The impact of the chromia dopant on in-reactor fuel performance (such as washout characteristics, RIA behavior, LOCA behavior, and FGR) has been adequately analyzed.
The NRC staff concludes that thermal-mechanical performance of the proposed fuel is adequately addressed in the Framatome submittal with the application of the RODEX4 fuel performance code. Fuel melt temperature and thermal conductivity are found to be affected by the chromia dopant in excess of any expected effect from grain size. Additional properties are affected by grain size, such as fuel swelling and steady state fragmentation. FGR is found to be adequately predicted using the existing correlation in RODEX4, for which grain size is an input.
Additionally, the NRC staff found chromia-doped NAF fuel to be well represented by existing gadolinia-doped fuel properties, with the exception of thermal conductivity and fuel melt temperature which were directly measured.
The NRC staffs SE of chromia-doped fuel is subject to the limitations and conditions listed in Section 4.0.
6.0 REFERENCES
- 1. ANP-10340P/NP, Revision 0, Incorporation of Chromia-Doped Fuel Properties in AREVA Approved Methods, AREVA, April 2016 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML16124B092 (Public) and ML16124B093 (Non-Public)).
- 2. Plan for Audit Supporting NRC Review of ANP-10340P, Revision 0, February 28, 2017 (ADAMS Accession No. ML17045A530).
- 3. Audit Report to Support the Review of AREVA Inc. Topical Report ANP-10340P, Revision 0, August 1, 2017 (ADAMS Accession Nos. ML17179A399 (Public) and ML17179A405 (Non-Public)).
- 4. Request for Additional Information Regarding AREVA Inc. Topical Report ANP-10340P, Revision 0, August 4, 2017 (ADAMS Accession No. ML17179A345).
- 5. Additional Information Regarding ANP-10340, Incorporation of Chromia-Doped Fuel Properties in AREVA Approved Methods, Framatome, March 28, 2018 (ADAMS Accession Nos. ML18092A601 (Public) and ML18092A602 (Non-Public))
- 6. NEA/CSNI/R(2010)1, Nuclear Fuel Behaviour Under Reactivity-initiated Accident (RIA)
Conditions, State-of-the-art Report, 2010, https://www.oecd-nea.org/nsd/docs/2010/csni-r2010-1.pdd
- 7. BAW-10247PA/NPA, Revision 0, Realistic Thermal-Mechanical Fuel Rod Methodology for Boiling Water Reactors, April 30, 2008 (ADAMS Accession Nos. ML081340208 (Public), ML081340383, and ML081340385 (Non-Public)
Attachment:
Comment Resolution Table Principle Contributors: Joshua Whitman, NRR/DSS Paul Clifford, NRR/DSS Date: May 23, 2018