RESOLUTION OF COMMENTS BY THE OFFICE OF NUCLEAR REACTOR REGULATION ON DRAFT SAFETY EVALUATION FOR TOPICAL REPORT ANP-10340P, REVISION 0, INCORPORATION OF CHROMIA-DOPED FUEL PROPERTIES IN AREVA APPROVED METHODS FRAMATOME, INC.

PROJECT NO. 728; DOCKET NO. 99902041 This attachment provides the U.S. Nuclear Regulatory Commission (NRC) staffs review and disposition of the comments made by Framatome Inc. (formerly AREVA Inc.) on the draft safety evaluation for Topical Report ANP-10340P, Revision 0, Incorporation of Chromia-Doped Fuel Properties in AREVA Approved Methods.

Page Line Proposed Change/Comment NRC Response 3 22 Add proprietary brackets around the The NRC staff agrees with highlighted text suggested editorial changes. Final SE modified accordingly.

12 24 Add proprietary brackets around the The NRC staff agrees with highlighted text suggested editorial changes. Final SE modified accordingly.

13 17 Add proprietary brackets around the The NRC staff agrees with highlighted text suggested editorial changes. Final SE modified accordingly.

13 38 Add proprietary brackets around the The NRC staff agrees with highlighted text suggested editorial changes. Final SE modified accordingly.

13 42,43 Add proprietary brackets around the The NRC staff agrees with highlighted text suggested editorial changes. Final SE modified accordingly.