Text

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTA ST., N.W., SUITE 3100

ATLANTA, GEORGIA 30303

Virginia Electric and Power Company

ATTN: J. H. Ferguson

APR 2 8 1981

Executive Vice President-Power

P. 0. Box 26666

Richmond, VA 23261

Gentlemen:

Subject: Report Nos. 50-280/81-06 and 50-281/81-06

Thank you for your letter of April 7, 1981, informing us of steps you have taken

to correct the item of noncompliance concerning activities under NRC Operating

License Nos. DPR-32 and DPR-37 brought to your attention in our letter of

March 13, 1981.

We have examined your corrective actions and have no further

questions at this time.

We discussed your position regarding NRC item 50-280,281/81-06-0l in a telephone

call with R. F. Driscoll on April 16, 1981, and informed him that after re-exam-

ining the matter we found no reason to change our conclusions.

The NRC position

continues to be that your inspector was not adequately acquainted with the

process of fillet weld size measurement.

The corrective action described in

your response letter appears adequate to provide compliance with the require-

ments of 10 CFR 50 Appendix B.

We will examine these actions in subsequent

inspections.

cc:

J. L. Wilson, Manager

Sincerely,

~.c. J .

R. C. L~g Director

Division of Resident and

Reactor Project Inspection