e JAN

  • 2 1980 APPENDIX A NOTICE OF VIOLATION Virginia Electric and Power Company Surry Power Station License Nos. DPR-32 DPR-37 Based on the NRC inspection November 27-30, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indi-cated below.

These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by Technical Specification 6.4.B.1.6, areas with radiation levels in excess of 1000 mrem/hr shall be provided with locked barricades to prevent unauthorized entry into these areas.

Contrary to the above, on November 27, 1979, the gate controlling access to the boric acid filter area (gate no. 7) did not have a lock adequate to prevent unauthorized entry.

Radiation levels were 2000 mrem/hr.