LER 79-033/03L-0:on 791127,during Normal Operation,Personnel Observed Reduction in Flow & Pressure in Charging Pump Svc Water Subsys.Caused by Broken Stem on 1-SW-107,w/valve Disc Partially Blocking Pump Supply.Valve Replaced
ML18136A320
Person / Time
Site: Surry Dominion icon.png
Issue date: 12/21/1979
From:
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18136A319 List:
References
LER-79-033-03L-01, LER-79-33-3L-1, NUDOCS 7912270560
Download: ML18136A320 (2)


Text


---~-ti - -

NRC FORM 366 U. Se::LEAR REGULATORY COMMISSION (7-77)

LICENSEE EVENT REPORT CONTROL BLOCK: LI_ _.____.__ _,__......__.___,l G) (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

~ I vi A/ sIP Is I 1 IG)l o I o I - I o I o I o I o I o I- Io I o 1014 I1 l 1 I 1 I 1 101 I I 0 7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T

[ITD 7 8

~;~~~~ LJ©I O I 5 I O I o Io I 2 I s I 0101 11 11 21 11 71 9 IG)I 11 2 I 2 I 1 I zI 9 IG) 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

I While Surry Unit No. 1 was in steady state operation at 100% power, Control Room persad-

[))}]* I nel observed a reduction in flow and pressure in the charging. pump service water

((II] I subsystem. This is contrary to T.S. 3.13B.2 and TS.S 3.14.A.5 and is reportable in

~ I accordance with T .S. 6. 6. 2. b. 2. The heal th and safety of the public were not affect-

[)))) I ed since the redundant train was operable.

[9]I]

ITTI.J 7 8 9 80 SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUS CODE COMPONENT CODE SUBCODE SUBCODE

[ill] 1w jB I@ I El@ !:!_j@ IVIAIL!VlEJxl@ 11U@ l!U@

7 8 9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LER/RO c-VENT YEAR REPORT NO; CODE TYPE NO.

@ REPORT NUMBER j 7 J 9 j 1-1 1013131 j/j 1° 13 J IU L=J LQJ 21 22 23 24 26 27 28 29 30 31 32 rKi51@fTIBfo~ 0r~A~ Mt'21

<"22) r ACTION FUTUi'lE EFFECT SHUTDOWN ATTACHMENT NPRD-4 PRIME COMP. COMPONENT 33

  • 34 35 \:::::) 36 I O I 00 0 ~ I 37 40 sui~1@

41 FORM SUB.

~@)

42 SUPPLIER

~@)

43 IP 44 MANUFACTURER 13 11 12 I@ 47 CAUSE DESCr'li?TION AND CORR::CTIVE ACTIONS @

IA broken stem on l-Sw-107 caused the valve disc to drop into the suction side flow

[IJI] !path of 1-SW-P-lOA w~ich resulted in a partial blockage of the pump supply and a CIIIJ 1 reduced outlet flow £nd pressure to the charging pump service water subsystem.

DJIJ l Corrective action was taken immediately to restore the flow path.

ITE18 7 9 so FACILITY METHOD OF A STATUS ~,c PQ\~/Eri OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION \:51 D:TIJ u@ l I O I O l I l0sJ N_.<l._

  • ___.J1.-j- - - - - - - - - '

LU@L.I__Op.....:...e_r_a_t_o_r_o_b_s_e_rv_a_t_i_on___________,

7 8 9 iO i2 13 44 45 46 BO ACTIVITY CONT!::NT ~

RELZASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE @

QE L:J @ LJ@l.-1-'------'-------'

7 8 9 10 11 44 45 NA BO PERSONNEL EX?OSUR!::S ~

CIT!] IO 7 8 9 y~sro J@)1T:tE1@LD-ES_C_R_IP_T_lNA_N_\:::;)_39-----------------------------~

11 12 13 80 PERSONNEL INJURIES ~

NU!,,1BEFJ.. D::SCRl?TION 41 8TI I0 Iu 1° l@)L____N_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _--:-:'

7 B 9 11 LOSS OF OR DAMAGE TO FACILITY TYPE DESCRIPTION 12

'4J\

i.::.::J 'l 912 2** 7* 0 5 i

. , , ,',(J 80

~ ~(§)IL--_NA_*- - - - - - - - - - - - - - - - - - - - - - - - - ~ * - ~

7 8 9 10 80 PUBLICITY (;';;\ NRC USE ONLY ISWEDQ DES~l3IPTION ~ "'

~ ~~,..._N_A_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~_ I I I I I I I I I I I I,~

n 68 69 so-;;;

-~------=--- ---e - - - -

e e SURRY POWER STATION, UNIT NO. 1 DOCKET NO. 50-280 REPORT NO: 79-033/031-0 EVENT DATE: 11/27/79 TITLE OF REPORT: Failure of Service Water Valve (l-SW-107)

1. DESCRIPTION OF EVENT:

W'..riile Surry Unit No. l was in steady state operation at 100% power, a reduction in charging pump service water subsystem flow and pressure was observed by Control Room personnel.

This event constitutes a condition contrary to T.S. 3.13.B.2 and T.S. 3.14.A.5, and is reportable in accordance with T.S. 6.6.2.b.(2).

2. PROBABLE CONSEQUENCES/STATUS OF REDUNDANT SYSTEMS:

The charging pump service water subsystem provides cooling water to the charging pump mechanical seal coolers and charging pump lubricating oil coolers. A complete description of the systems is contained in FSAR sections 9.4.1.4 and 9.4.3.5.

The degradation of the affected system did not have any direct safety implications. Since the redundant train was operable, the health and safety of the public were not affected.

3. CAUSE OF THE EVENT:

The valve stem was broken due to deterioration.

4. IM.'1EDIATE CORRECTIVE ACTION:

The dropped disc was removed to restore the flow pa th.

5. SCHEDULED CORRECTIVE ACTION:

The degraded valve has been replaced.

6. ACTION TAKEN TO PREVENT RECURRENCE:

None re-quired.

7. GENERIC IMPLICATIONS:

This has been identified as a generic problem. A design change package has been generated to replace all affected valves with ball valves in the Charging Pump Service Water Subsystem. The modification has been implemented on Unit 2 and Unit 1 will be completed during the SGRP outage.