U.S. NRC Operational Experience Data Collection Program NEA Workshop on the Use of Operational Experience in PSA April 26-27 2018 John C Lane Office of Nuclear Regulatory Research U.S. NRC
Topics of Discussion Recognition of Importance of OpE data Where does U.S. OpE data come from?
How is OpE data gathered, coded, analyzed?
Where is OpE data housed?
Who uses OpE data?
2
WASH-1400 (1975)
Mid-1970s 1st computer file of Reportable Occurrences (73)
Documented the need for comprehensive OpE Nuclear Plant Reliability Data System (NPRDS)
Managed by Southwest Research Institute for Edison Electric Institute (1974)
Voluntary industry initiative Engr & failure data on components 3
Late 70s-80s President Jimmy Carter -1977-make mandatory the current voluntary reporting of minor mishaps and component failures at operating reactors, in order to develop the reliable data base needed to improve reactor design and operating practice NUREG-0161-LER Data Entry Guidance for Tech Spec Reportable Occurrences (1977)
Formalized in LER Rule (1983, 10 CFR 50.73)
Originally managed at ORNL via the Sequence Coding Search System (SCSS, 1984)
Idaho National Lab has managed since 2000 4
LER Reporting 5
Reportable Events require submission within 60 days:
- Plant shutdown resulting from a Technical Specification requirement
- Operations or plant conditions prohibited by Tech Specs
- Safety barriers degraded
- A previously unanalyzed condition
- A natural phenomena posing a threat to the facility
- Manual or automatic reactor scram (except pre-planned scrams)
- Inadvertent actuation of:
- Containment Isolation System
- Containment heat removal system
- Emergency service water system
LER Search 6
1990s Maintenance Rule-1991 (10CFR50.65)
- Required additional OpE capability to track component failures in safety and non-safety systems
- Use OpE to help set performance goals PRA Policy STMT--1995 INPO (Institute for Nuclear Power Operations)
- EPIX-1998 (Equip Performance & Information Exchange)
2000s MSPI-Mitigating Systems Performance Index (2005)
- Monitor(s) the performance of 5 systems based on their ability to perform risk-significant functions
- HP coolant injection/core spray/safety injection
- Rx Core Isolation Cooling/Emergency Feedwater
- Emergency AC power
- Cooling water support system
- Attempts to balance the need for maintenance (availability) with equipment performance (reliability) 8
9 2018
Publicly Available Data Summaries http://nrcoe.inl.gov/resultsdb/
10
Primary Data Source for Reliability Data Equipment failure data captured in the INPO Consolidated Events Database (ICES)
Formerly EPIX (prior to 2013)
Data from 1998 transition from NPRDS
- Supports data for:
- Maintenance Rule
- Mitigating Systems Performance Index (MSPI)
- Reactor Oversight Process (ROP)
- Data is proprietary, only accessible by INPO members
- Data is input by each utility in the U.S.
- Amount of data provided varies by utility
- All provide required MSPI data, but some provide significantly more
- Includes demand and run time data for some systems 11
RADS (Reliability & Availability Data System)
INL Computer Program Uses either plant-specific or generic data Reliability (failures per demand probability/failure rate to operate)
Train or component level data on unavailability (planned/unplanned unavailability) due to test and maintenance Used by NRC staff and industry for submission of licensing action requests Provides reliability parameters for SPAR models Helps focus NRC inspections on the most risk significant systems Aids in the review of requests for unit-specific licensing actions Monitors maintenance rule implementation Supports reliability analyses of risk-significant systems/components 12
Primary Data Source for Initiating Events 13
- Licensee Event Reports (LERs)
Reports required to be submitted to the NRC per LER Rule Event Report Guidance provided in NUREG-1022 Primary source of initiating events information Significant safety system failures are reported
- Event Notification Reports (ENs) (10 CFR 50.72)
- Inspection Reports (IRs)
- Monthly Operating Reports (MORs)
Primary source of operating time data Required by NRC Generic Letter 97-02
Initiating Event Studies Review all unexpected reactor trips during power operations Each event is categorized according to the initial plant fault and functional impact The collected data are analyzed for time dependence, reactor-type dependence, and between-plant variance Dependencies and trends are reported, along with the raw counts and the best estimate for initiating event frequencies
References:
NUREG/CR-5750 "Rates of Initiating Events at U.S. Nuclear Power Plants: 1987-1995 NUREG/CR-6928, Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants 14
Loss of offsite power Loss of vital AC bus Loss of vital DC bus Very small LOCA Loss of Component Cooling Water Loss of feedwater Partial Loss of Service Water BWR loss of instrument air BWR stuck open SRV BWR loss of heat sink BWR general transients PWR loss of instrument air PWR steam generator tube rupture PWR stuck open SRV PWR loss of heat sink PWR general transients Categories of Initiating Events 15
Fire Events Data Base NRC/EPRI developed Fire Events Database in 2011 from:
- Event Notifications and LERs from 1990 to present
Development of Fire PRA Initiating Event Frequencies Industry compliance with NFPA 805 (National Fire Protection Assoc)
NRR Fire Metrics 16
Component Studies Tasks:
- Risk analysis of operating data
- Engineering analysis of trends Provides insights into the performance of components on an industry-wide basis
- Turbine-Driven Pumps (TDP)
- Motor-Driven Pumps (MDP)
- Air-Operated Valves (AOV)
- Motor-Operated Valves (MOV) 17
System Reliability Studies Boiling Water Reactor Systems:
- High Pressure Coolant Injection (HPCI) System
- High Pressure Core Spray (HPCS) System
- Isolation Condenser (IC) System
- Reactor Core Isolation Cooling (RCIC) System Pressurized Water Reactor Systems:
- Auxiliary Feedwater (AFW) System
- High Pressure Safety Injection (HPSI) System Common System:
- Emergency Power System 18
Common Cause Failure Studies Common-Cause Failure Database includes:
- method for identifying CCF events
- coding and classification of events for use in CCF studies
- computer system for storing and analyzing the data CCF events are component failures that satisfy four criteria:
- Two or more individual components fail, are degraded or have deficiencies that would result in component failures if a demand signal had been received
- Components fail within a selected period of time such that success of the mission would be uncertain
- Components fail because of a single shared cause and coupling mechanism
- Components fail within the established component boundary 19
CCF (continued)
Studies:
- motor-operated valves
- motor-driven pumps
- circuit breakers
Reference:
"Common-Cause Failure Event Insights" (NUREG/CR-6819), Volumes 1 through 4 (2003) 20
21
- A users guide describes each study and provides guidance for completing each field in the IDCCS
- The IDCCS program utilizes numerous lookup tables and automated checks to ensure data consistency
- Records are entered by qualified coding engineers
- Each record is independently checked by a second qualified coding engineer
- The IDCCS software randomly selects a sample of records for an independent quality review semi-annually Data Quality Controls 22
NRC Equipment Reliability Database Sample Input 23
NRC/Industry Uses for OpE Data NRC/RES
- SPAR Models
- Accident Sequence Precursor Program NRC/NRR
- Mitigating System Performance Index
- Operating Experience Clearinghouse
- Regional Inspectors
- Significance Determination Process/SRAs Industry/Public
- Reference material for plant-specific PRA models
- LERSearch 24
25
26 NRC OpE Clearinghouse Screening Communication Evaluation Application Incident Reporting System (IRS)
International Nuclear Event Scale (INES)
Bilateral Exchanges International OpE Daily Event Reports
- Plant Status Reports
- Licensee Event Reports
- Part 21 Reports
- INPO Reports Domestic OpE: Industry Inspection Findings
- Preliminary Notifications
- Regional Project Calls Construction Experience Studies/Trends Domestic OpE: NRC OpE Clearinghouse Generic Communications
- OpE Briefings COMMunications Periodic OpE Newsletter OpE Notes Notable OpE Tech Review Group Report Informing Stakeholders Inspection
- Licensing
- Influencing Agency programs Rulemaking
- Information Request
- Taking Regulatory Actions Storage OpE Program Inputs Products
- Available on the public NRC Web Page
Screening Follows NRC Directive LIC-401 NRR-NRO Reactor Operating Experience Program Tiered response/disposition
- Formal screen in Issue for Resolution
- Staff follow-up and summary OpE COMMunication
- Email issue Technical Review Group Note
- Information only No Action 27
Communications Generic and Safety Significant issues may warrant notice Examples:
- Information Notice
- Generic Letter
- Regulatory Issues Summary
- Publication of OpE study 28
Coordinated International Activities Relationship focused
- NEAs Working Group on Operating Experience (WGOE)
- IAEAs International Reporting System
- International Common Cause Database (ICDE) 29