Notice of Deviation from Insp on 790320-23
ML18116A202
Person / Time
Site: Surry  
Issue date: 05/17/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML18116A199 List:
References
50-280-79-14, 50-281-79-20, NUDOCS 7907260007
Download: ML18116A202 (2)


Text

APPENDIX B NOTICE OF DEVIATION Virginia Electric and Power Company License No. DPR-37 Based on the results of the NRC inspection conducted on March 20-23, 1979, certain of your activities appear to deviate from your commitments to the Commission, as indicated below.

A.

Table 6-1 of the "Steam Generator Replacement Program Manual" lists specific measures implemented to maintain radiation doses as low as reasonably achievable including:

1.

Establishing low radiation zones in containment for personnel to use for rest breaks.

2.

Minimizing the streaming of radiation by installing shielding such as plugs in open-ended pipe lines following cutting.

3.

Performing preoperational briefings to instruct personnel of the requirements of a work package.

4.

Assuring that the number of persons who must enter high radiation areas or contaminated areas be held to a minimum, that the period of time persons must remain in these areas be minimized and that the magnitude of the potential dose be maintained to the lowest levels coD1Densurate with other considerations.

S.

Keeping zones with high dose rates as small as possible considering the work requirements.

Contrary to the above,

1.

On Harch 21, 1979, two to six individuals waited in 5 to 50 mrem/hour zones for up to four hours awaiting the use of the polar crane to move reactor coolant piping into an electrolysis tank.

They stayed in this area because they were told that the crane would be available within thirty minutes all morning long.

2.

The shield plugs of a section of reactor coolant p1p1ng, were removed at approximately 0300 on Harch 21, 1979, but the pipe could not be placed in the electrolysis tank until approximately 1500 on March 21, 1979.

The premature removal of the shield plugs resulted in radiation levels of 10 rem/hr at the open end of the pipe and 50 MAY l 8 191

MAY 1 8 1979 Appendix B Virginia Electric and Power Company License No. DPR-37 Notice of Deviation mrem/hr 10 feet away.

The cart on which the pipe was stored had to be moved by hand approximately 40 feet after the shielding was removed.

3.

On March 21, 1979, three workers were told to report to the base-ment of containment to await instruction concerning their assignment.

The workers waited in an area with radiation levels of 5 to 10 mrem/hr for approximately 30 minutes before being briefed as to the specifics of the work package.

4.

On March 22, 1979, three workers spent at least two hours searching containment in 5 to 50 mrem/hour fields, attempting to locate fittings for pipe which they were to run.

5.

From March 20 - 23, 1979, from one to six individuals frequently waited for 5 to 15 minutes in radiation fields 10 to 20 mrem/hour outside C cubicle near the RHR platform.

A low-dose area was approximately fifty feet down the corridor.