MAY 10 1~79 APPENDIX A NOTICE OF VIOLATION Virginia Electric and Power Co.

Surry 1 and 2 License Nos. DPR-32 DPR-37 Based on the results of the NRC inspection on April 9-13, 1979, it appears that certain of your activities were not conducted in full compliance with NRC requirements as indicated below. These items have been categorized as described in our correspondence to you dated December 31, 1974.

A.

As required by Amendment No. 46 to Unit 2's operating license issued January 24, 1979, the Health Physics Program and procedures which have been established for the Steam Generator Replacement Program shall be implemented. The Health Physics Manual for the Steam Generator Replace-ment Project, Procedure HP-SGRP-10, Paragraph B.2.d, requires that test and checks of tents be performed by Health Physics and an acceptance or "stop" sticker affixed to the tent.

B.

C.

Contrary to the above, the tents located on the -18 foot elevation of Unit 2 being used for the removal of slag from the reactor coolant system pipe prior to decontamination of the pipe and being used for working miscellaneous piping had not been inspected nor an acceptance label affixed on April 11, 1979.

This is an infraction and applies to Unit 2.

As required by 10 CFR 20.201(b), each licensee shall make or cause to be made such surveys as may be necessary for him to comply with the regulations in this part.

Contrary to the above, radioactive liquid effluents from the plant's subsurface drain system were auotmatically pumped to the discharge canal between January 1, 1979 and April 11, 1979 without performing radioactivity analyses of the effluents at a frequency adequate to ensure that 10 CFR 20 limits are not exceeded.

This is an infraction and applies to Units 1 and 2.

As required by 10 CFR 20.203(b), each radiation area should be conspic-uously posted with a sign or signs bearing the caution symbol and the words "Caution -

Radiation Area." 10 CFR 20.202(b)(2) states that 1

\\-1'

\\1!

Jf l

.190171$0 l, 8 ~

....... ----------~- ------ -- ----- --


.----------**-~---~* ----

-. -~ #**, *

--~~~-~

_!-.., __ *-*~'*------~.. *,- *-*'-- *-*-.. ----*-~**

MAY 10 1979 "Radiation Area means any area, accessible to personnel, in which there exists radiation,... at such levels that a major portion of the body could receive in any one hour a dose in excess of 5 millirem II Contrary to the above, on April 12, 1979, a radiation area near a piece of reactor coolant system pipe located outside the Unit 2 equipment hatch was not posted as a radiation area. Radiation levels in accessible areas near the pipe were 10 - 20 mR/hr.

This is an infraction and applies to Units 1 and 2.