05000280/LER-1979-018-01, /01T-0 on 790509:solenoid Valve Model 8320A102 Mfg by Automatic Switch Co Found Environmentally Unqualified & Reportable Per IE Bulletin 79-01 & Tech Specs.Valve Could Fail to Control Admission & Venting of Air During LOCA

From kanterella
(Redirected from ML18114A608)
Jump to navigation Jump to search
/01T-0 on 790509:solenoid Valve Model 8320A102 Mfg by Automatic Switch Co Found Environmentally Unqualified & Reportable Per IE Bulletin 79-01 & Tech Specs.Valve Could Fail to Control Admission & Venting of Air During LOCA
ML18114A608
Person / Time
Site: Surry  
Issue date: 05/23/1979
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18114A607 List:
References
LER-79-018-01T, LER-79-18-1T, NUDOCS 7905290010
Download: ML18114A608 (2)


LER-1979-018, /01T-0 on 790509:solenoid Valve Model 8320A102 Mfg by Automatic Switch Co Found Environmentally Unqualified & Reportable Per IE Bulletin 79-01 & Tech Specs.Valve Could Fail to Control Admission & Venting of Air During LOCA
Event date:
Report date:
2801979018R01 - NRC Website

text

NRC FORM 366

.: **--W -*~>> Oil I c-...... z (7-7:i'i LICENSEE EVENT REPORT e V

CONTROL BLOCK: L____----'-~~-------'l~_____,___~'-----'IG) 6 (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

' ~

I v I A I s I P I s I 1 10.,,,_l o..___,___,_I o-'-----'--=I =----.!.-I.I oL-.1.-.1-1 o'---'-'-1 o'--:'--'--1 n._. :'-'-I a'----'---=1 '-----'-'-I o'---W-1 o'-=!I ! 4 I 1 I 1 I 1 I 1 I© I I

I 0 7.

8 9

LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 CON'T

~ REPORT I T Ir:'\\ I I

~ SOURCE ~\\.._V Q 5

7 8.

60 61 DOCKET NUMBER 68 ol o I o I 2 I s I o IG)I a I s I o I 9 I 1 69 EVENT DATE gjG)! ol sl 2! 3!7 I 9 IG) 74 75 RE.PORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

@IIJ I The Architect Engineer has i den ti fi ed Sol Pnoi a Valve, Model #832DAJ 02, marn,fac-tnred by I

[]JI] I Automatic Switch Company, as being environmentally unqualified and reportable as pe:!:_J

~

l I.E.Bulletin 79-01 and Technical Specification 6.6.2.b. (9).

The valve could fail to [QJ}J I control the admission and venting of operating air for the inside containment trip

~

jvalves on steam generator blowdown lines during a LOCA.

The fully redundant outside (III] ~'!~.tainment trip valves Would have provided containment isolation, if required, C§:1[] !Therefore, the health and safety of the public were not affected.

I 7

8 9 80

~

7 8

SYSTEM CODE

  • 1 s In I@

9 10 t::;\\

LER/RO CVENT YEAR

\\;.:./ REPORT I 7 I 9 j NUMBER 21 22

CAUSE

CAUSE CODE SUBCODE COMPONENT CODE uJ@ LBJ@ Iv IA h. I VI O I P,e 11 12 13 SEQUENTIAL REPORT NO.

lo I 1 I s !

18 OCCURRENCE CODE I a I, I 23 24 26 27 28 29 COMP.

SUBCODE W

19 REPORT TYPE LTJ 30 VALVE SUBCODE w@

20 31 ACTION FUTURE EFFECT SHUTDOWN ATTACHMENT NPRD-4 FORM SUB.

PRIME C.OMI'.

SUPPLIER REVISION NO. w 32 COMPONENT MANUFACTURER TAKEN ACTION ON PLANT METHOD HOURS ~ SUBMITTED

~@Lu@ LLJ@

LLI I o I o I o I o I L.x.l@

33 34 35 36 37 40 41

  • w@*

42 W@

JA 16 I 1 IO I@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

43 44 47

!The solenoid valves, Model #8320Al02, were identified as being similar to a solenoid_

[III] jvalve that failed environmental testing for the LOCA environment.

The three affected [I))] jon each unit wili be replaced with environmentally qualified valves.

D.JTI 7

8 9

FACILITY STATUS

% POWER OTHER STATUS @

METHOD OF

['.)ISCOVERY 80 ITJIJ w@, o I o, o 1@._1 __

N_A __ __ L12.J@)I DISCOVi:rfY DESCRIPTION *@

Notification frc-m AE

-~----------J 8

9 10 12 13 ACTIVITY CONTENT r::;;,.

RELEASED OF RELEASE AMOUNT OF ACTIVITY

~

w@) ul(§.__I __

...o..;N=A ____

7 B

9 10 11 7

45 46 44 80 LOCATION OF RELEASE @

NA 44 45 80 PERSONNEL EXPOSURES Q

NUMBER TY?E D:cSCRIPTION GID I o b I oJ@W@._-__......,_N~A----------------'-------"----.J 7

8 9

11 12 13 PERSONNEL INJURIES Q

NUMBER DESCRIPTION~

l:iTIJ I o I o I a I@

7 8

9 11 12 ______

_,_ __________ ~------------'------------'80 LOSS OF OR DAMAGE TO FACILITY 143\\

TYPE

DESCRIPTION

i.::_::J

. 7'9 Q 52--9 0"' /Q -

[IIIl lz_J(§_)j~~N=A'----------------------------~-----'

80 7

8 9

10 80 I

PUBLICITY

(';;;\\

ISSUED(,":;;\\ DESCRIPTION~

NRC USE ONLY 0:I1 W~..__---ilU------------------------' I I I I I I I 1

  • 1 I I I I ~
  • 7 8

_9 10 68 69 W. L. Stewart NAME OF PREPARER------------------

PHONE:

(804) 357-3184 80 ;;;

0 Q_

l!l

(Attachment, page 1 of 1)

Surry Power Station, Unit 1, 2 Docket No: 50-280, 281 Report No: 79-018/0lT-0 Event Date:

05-09-79

. Environmentally.Unqualified Solenoid Valve (SOV-BD-lOOA,B,C and 200A,B,C)

1.

Description of Event

The Architect Engineer has identified a solenoid valve, Model #8320Al02, manufactured by Automatic Switch Company, as being environmentally *unqualified for the conditions stated in I.E. Bulletin No. 79-01.

Six valves were identified, three in each of Surry Units 1 and 2.

2.

Probable Consequences and. Status of Redundant. Systems:

3.
4.

The solenoid valve could fail to function properly following a Loss of Coolant Accident.

These valves control the admissio~ and venting of operating air for the containment trip valves on steam generator blowdown lines.

The ful1y redundant outside containment trip valves would have provided containment isolation, if required.

Therefore, the health and safety of the public were not affected.

Cause

The solenoid valves, Model l/8320Al02, were identified as being similar to another solenoid valve that failed environmental testing.

Immediate Corrective Action

A search was initiated to locate environmentally qualified sol*enoid valves.

5.

Subsequent Corrective Action:

The subsequent corrective action will be the replacement of the present solenoid valves with environmentally qualified solenoid valves.

6.

Action Taken to Prevent Recurrence:

No additional actions are deemed necessary.

The solenoid valves are being replaced.

7.

Generic Implications:

Envirom:n=:ntal qualifications of other electrical components will be addressed in the response to IE Bulletin No. 79-01.