"' /; . ). PS~G
- Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit August-21, 1996 (SCH96-114)
Chief George Caporale Bureau of Information Systems CN-029 Trenton, NJ 08625
Dear Chief Caporale:
NEW JERSEY POLLUTANT DISCHARGE ELIMINATION SYSTEM DISCHARGE MONITORING REPORTS SALEM GENERATING STATION PERMIT NO. NJ0005622 Attached is the Discharge Monitoring Report for Salem Generating Station containing the information as required in Permit No.
NJ0005622 for the month of July, 1996.
This report is required by and prepared specifically for the Environmental Protection Agency (EPA) and the New Jersey Department of Environmental Protection (NJDEP). It presents only the observed results of measurements and analyses required to be performed by the above agencies. The choice of the measurement devices and.analytical methods is controlled by EPA and NJDEP, not by the company, and there are limitations on the accuracy of such measurement devices and analytical techniques even when used and maintained as required. Accordingly, this report is not intended as an assertion that any instrument has measured, or any reading or analytical result represents, the true value with absolute accuracy, nor is it an endorsement of the suitability of any analytical or measurement procedure.
\
r-~-:::9~6~0~82~8~0N2~1tc83C9~6~0\i7~3111~~~~~~l PDR ADOCK 05000272 j General Manager -
R PDR Salem Operations SRT:pc Attachments The po'vvn is in your hands.
95-2168 REV. 6/94
1 NJPDJ;:S Report
'July, 1996
- C Mr. Gerald M. Ransler - Executive Director USNRC - Document Control Desk Unit#l-50-272 Unit#2-50-311 Manager-Licensing & Regulations M. Vaskis D. Hurka Central Record Facility File SCH96-114
1NJPDES Report Explanation of Deviations July, 1996 The following explanations are included to clarify possible deviations from permit conditions.
General - The columns labeled, "No. Ex.," on the enclosed DMR, tabulate the number of daily discharge values outside the indicated limits.
Data reporting and accuracy reflect the working environment, the design capabilities and reliability of the monitoring instruments and operating equipment.
All reported concentrations are based on daily discharge values.
Total residual chlorine is performed three times per week during chlorination unless otherwise indicated.
Analytical values which are less than detectable are reported as zero unless otherwise indicated.
Analytical results for all parameters other than pH,
Bioassay results are provided by AnalytiKEM Inc.
(NJDEP certification 82888).
Net negative discharge values are reported as negative.
489C Flow thru outfall 489 is calculated based on Oil water Separator Lift Pump run times.
481-486 - Chlorination of the circulation water system normally does not occur except as otherwise noted.
Service water system chlorination is normally continuous and is monitored on the circulating water system outfall.
Chlorination of both systems will be indicated by results reported for both and represents their combined effect upon the circulating water outfall.
,NJPDES Report -
'Explanation of Deviations July, 1996 48C - Non-Radioactive Liquid Waste - This system continues to be operated in a batch mode to treat for hydrazine and ammonia by the addition of sodium hypochlorite. No hydrazine has been discharged from this outfall during the reporting period. Residual chlorine is monitored at the outfalls of DSN's 481, 482, 484, and 485, and has not exceeded the permit limits at these outfalls.
The following excursions are included in the attached report and are explained below. Excursions have not endangered nor significantly impacted public health or the environment.
DSN NO. EXPLANATION NONE
COUNTY OF SALEM STATE OF NEW JERSEY I, David F. Garchow, of full age, being duly sworn according to law, upon my oath depose and say:
- 1. I am General Manager of Salem Generating station, and as such, am authorized to sign Discharge Monitoring Reports submitted to the New Jersey Department of Environmental Protection pursuant to the Station's New Jersey Pollutant Discharge Elimination System permit.
- 2. I have reviewed the attached Discharge Monitoring Reports.
Pursuant to N.J.A.C. 7:14A-2.4, I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments and that based on my inquiry of those individuals responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.
- 3. The signature on the attached Discharge Monitoring Reports is my signature and I am submitting this affidavit in satisfaction of the requirement that my signature be notarized.
David F. Ga chow General Manager -
Salem Operations Sworn and subscribed bef o_J'.e me
<-; ~ d~y of~ ~996.
this 1
(
1 --2 c..A.-/. w-~ I t-.,,c-UU 2_? J BARBARA A. POWELL
~OTARY .P~BllC OF NEW JERSEY Y Comm1ssmn Expires Dec. 2, 1998 ID# 2160323
Form T-VWX-.01*4 NEW JERSE.PT. OF ENVIRONMENTAL PROTECTION - ENERGY 2/92° MONITORING REPORT -TRANSMITTAL SHEET NJPDES NO. REPORTING PERIOD MO. YR. MO. YR.
PERMITTEE: Name Public Service Electric and Gas Company Address P.O. Box 236 Hancock's Bridge, NJ 08038 FACILITY: Name Salem Nuclear Generating Station Address Alloway Creek Neck Road Hancock's Bridge (County) Salem Telephone (609) 935-6000 FORMS ATTACHED (Indicate Quantity of Each) OPERATING EXCEPTIONS SLUDGE REPORTS - Sanitary YES NO DT-VWX-007 D T-VWX-008 D T-VWX-009 DYE TESTING D [2J SLUDGE REPORTS - Industrial TEMPORARY BYPASSING D [2J D T-VWX-01 OA D T-VWX-01 OB DISINFECTION INTERRUPTION D [2J WASTEWATER REPORTS MONITORING MALFUNCTIONS D [2J D T-VWX-011 D T-VWX-012 D T-VWX-013 UNITS OUT OF OPERATION D [2J OTHER D [2J GROUNDWATER REPORTS D VWX-015(A,B) D VMX-016 *'0 VMX-017 (Detail any "Yes" on reverse side in appropriate space.)
NPDES DISCHARGE MONITORING REPORT NOTE: The "Hours Attended at Plant" on the
~EPA FORM 3320-l reverse of this sheet must also be completed.
AUTHENTICATION- I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.
_LICENSED OPERATOR PRINCIPAL EXECUTIVE OFFICER or DULY AUTHORIZED REPRESENTATIVE Name(Printed) JOHN F. LEOPARDI Name (Printed) DAVID F. GARCHOW
&~e * ;~o.~~13703 Gen. Mg,. S$l=-='
CluD r. W G.rade Title(Printed)
Srgnatu ~"'""°T~t-~--"-==========-~~~ Signature
_)
Date 08/20/96 Date 08/20/96
OPERATING EXCEPTIONS DETAILED
'NONE ',
- Page 2 HOURS ATTENDED AT PLANT Month l_Qj_z_J Year UU..§J Day of Month 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Licensed Operator 8 8 8 0 8 0 0 8 8 8 8 8 0 0 8 8 Others 4 4 4 0 4 0 0 4 4 4 4 4 0 0 4 4 Day of Month 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Licensed Operator 8 8 8 0 0 8 8 8 8 8 0 0 8 8 8 Others 4 4 4 0 0 4 4 4 4 4 0 0 4 4 4
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (17-19) MAJOR ADDRESS=P.O. BOX 236/N21 = = = = = = = NJ0005622 FACA
_ _ _ HANCOCK~RIDGE_,NJ~038_ _ _ _ PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY THERMAL DSCHG FOR DSN 481-483 FROMt-----1---t----l TOt-----t---t----i LOCATIO~ LOWER _!:_LLOWAY__§__ CREEK_!_ NJ _Q_8 0 3 8_ - 96 07 01 96 07 31 SOUTHERN REGION / SALEM DMR NUMBER: NJ0005622 FACA 071996 (20-21) (22-23) (24-2 5) (26-27) (28-29) (30-31)
(3 Card Only) QUANTITY OR LOADING (4 Card Only) QUALITY OR CONCENTRATION PARAMETER
- (46-53) (54-61) (38-45) (46-53) (54-61) NO .
EX FREQ.
OF SAMPLE (32-37) (62 ANALYSIS TYPE UNITS UNITS 63) (64-68) (69-70)
- ****** ****** 23.2 24.4 EFFLUENT NET VALUE TEMPERATURE, WATER DEG. CENTIGRADE 00010 7 0 INTAKE FROM STREAM NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED t - - - - - - - - - - - - - - - - - - 1 A N D AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GAR CHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG- 09 935-6000 96 08 16 NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 USC § 1001 AND t - - - - - - - - - - - - - - - - - - 1 3 3 USC § 1319. (Penalties under these statutes may include fines up to AREA TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) CODE NUMBER YEAR MO DAY EFFLUENT TEMP IS TO BE CALCULATED AS THE COMBINED AVERAGE OF EACH OF THE SEPARATE DISCHARGES 481-483.
NET TEMP DIF IS THE DIFFERENCE BETWEEN THE AMBIENT RIVER WATER TEMP AND THE AVE EFFLUENT TEMP OF 481-483.
EPA Form 3320-1 (Rev. 9-88) Previous editions may be used. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (17-19) MAJOR
==
ADDREss-P-:-o-.-BOX236/N2l- -
HANCOCKSBRIDGE,NJ08038
=
- - - NJ0005622 PERMIT NUMBER MONITORING PERIOD FACB DISCHARGE NUMBER FACILITY PSE&G SALEM GENERATING STATION LOCATION LOWER ALLOWAYS CREEK, NJ 08038 DMR NUMBER: NJ0005622 FACB 071996
= YEAR MO DAY YEAR MO DAY FROM t---,----,-+-,,--,-,---t----,-t TOt---,-,..-t---=--t--:--,--~
96 07 01 (20-21) (22-23) (24-25) 96 07 31 (26-27) (28-29) (30-31)
THERMAL DSCHG FOR DSN 484-486 SOUTHERN REGION / SALEM
- * (46-53) (54-61) (38-45) (46-53) (54-61) NO. FREQ
- PARAMETER (32-37)
- t-------~------~----+-------~------~-----~-----<EX OF (62 ANALYSIS SAMPLE TYPE UNITS UNITS 63) (64-68) (69-70)
- ****** ****** 24.6 27.0 EFFLUENT NET VALUE TEMPERATURE, WATER DEG. CENTIGRADE 00010 7 0 INTAKE FROM STREAM NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED 1 - - - - - - - - - - - - - - - - - - - < AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F . GARCHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG- 09 935-6000 96 08 16 NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 use § 1001 AND 1 - - - - - - - - - - - - - - - - - - - < 3 3 USC § 1319. (Penalties under these statutes may include fines up to AREA TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) CODE NUMBER YEAR MO DAY EFFLUENT TEMP IS TO BE CALCULATED AS THE COMBINED AVERAGE OF EACH OF THE SEPARATE DISCHARGES 484-486.
NET TEMP DIF IS THE DIFFERENCE BETWEEN THE AMBIENT RIVER WATER TEMP AND THE AVE EFFLUENT TEMP OF 484-486.
EPA Form 3320-1 (Rev. 9-88) Previous editions may be used. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE Nl\ME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
==
DISCHARGE MONITORING REPORT (DMR)
Nl\ME PSE&G (2-16) (17-19) THERMAL DSCHG FOR DSN 48i-486 ADDRESS=P.O. BOX 236/N21 = = = NJ0005622 FACC
_ _ _HANCOCK~RIDGE_,NJ~038_ _ _ _ PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MAJOR SALEM FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY SOUTHERN REGION LOCATION LOWER ALLOWAYS CREEK, NJ 08038 FROM 1----+----+------1 T0>----+----+------1 96 07 01 96 07 31 nMR.NtiMB°ER:NJOoos622ncc - -071996- (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
(3 Card Only) QUANTITY OR LOADING (4 Card Only) QUALITY OR CONCENTRATION (46-53) (54-61) (38-45) (46-53) (54-61) NO. FREQ.
PARAMETER (32-37)
- EX OF (62 ANALYSIS SAMPLE TYPE UNITS UNITS 63) (64-68) (69-70)
THERMAL DISCHARGE 58 313 ****** ****** ******
MILLION BTUS PER HR.
00015 2 0 ~~rr:w~~;;;;m~~~~mD~~~
INTAKE FROM STREAM Nl\ME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED t - - - - - - - - - - - - - - - - - - - - i A N D AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F . GAR CHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION NIFICANT s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG-PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING 09 935-6000 96 08 16 THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 USC § 1001 AND r - - - - - - - - - - - - - - - - - i 33 USC § 1319. (Penalties under these statutes may include fines up to AREA TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) CODE NUMBER YEAR MO DAY EPA Form 3320-l (Rev. 9-88) Previous editions may be used. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (17-19) MAJOR ADDRESS=P.O. BOX 236/N21 = = = = = = = NJ0005622 048C
_ _ _HANCOCK~RIDGE_,NJ~038_ _ _ _ PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY LOCATION LOWER ALLOWAYS CREEK, NJ 08038 FROM >--9-6-+--0-7-+--0-1-----< TO>-----<----+---<
96 07 31 SOUTHERN REGION / SALEM
-DMR--m1MBER:NJ0005622648C- - 0 7 1 9 9 6 - (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
- (46-53) (54-61) (38-45) r--------,---------,-----t---------.--------.----------.------1EX (46-53) (54-61) NO. FREQ .
OF SAMPLE (32-37)
- UNITS UNITS (62 63)
ANALYSIS (64-68)
TYPE (69-70)
SOLIDS, TOTAL ****** ****** ****** 6 9 SUSPENDED 00530 1 0 CARBON, TOT (TOC) 00680 1 0 EFFLUENT EFFLUENT GROSS NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED r - - - - - - - - - - - - - - - - - - ; A N D AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GAR CHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG- 09 935-6000 96 08 16 NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 use § 1001 AND t----------------~33 USC § 1319. (Penalties under these statutes may include fines up to AREA TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) CODE NUMBER YEAR MO DAY EPA Form 3320-1 (Rev. 9-88) Previous editions may be used. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (l7-l9) MAJOR ADDRESS=P.O. BOX 236/N21 = = = = = = = NJ0005622 481A
_ _ _HANCOCK~RIDGE_,NJ~038_ _ _ _ PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY FROMl--9-6-+--0-7--+-0-l-l TOl---+----+---l LOCATION LOWER ALLOWAYS CREEK, NJ 08038 96 07 31 SOUTHERN REGION / SALEM DMRNUMBER~~~ill2~Th--onffi- (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
- (3 Card Only) QUANTITY OR LOADING (46-53) (54-61)
(4 Card Only)
(38-45)
QUALITY OR CONCENTRATION (46-53) (54-61) NO. FREQ.
PARAMETER (32-37)
- t---------.--------..----+--------.--------,--------r-----1EX OF (62 ANALYSIS SAMPLE TYPE UNITS UNITS 63) (64-68) (69-70)
LCSO STATRE 96HR ACU ****** ****** CODE= ****** ******
CYPRINODON TAN6A 1 0 EFFLUENT GROSS PH 00400 1 0 EFFLUENT GROSS PH 00400 7 0 INTAKE BELOW NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED 1 - - - - - - - - - - - - - - - - j A N D AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GARCHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG- 09 935-6000 96 08 16 NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 USC § lOOl AND l - - - - - - - - - - - - - - - - j 3 3 USC § l3l9. (Penalties under these statutes may include fines u -to AREA TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) CODE NUMBER YEAR MO DAY PARAMETER 50060 LOCATIONS: "R" = SWS DSCHG (NO CWS FLOW} 11 8 11 = SWS DSCHG (NORMAL COND}
11 11 ENTER NODI FOR LOCATIONS THAT DO NOT APPLY.
WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES PER WEEK DURING 2-HR PERIODS OF CHLORINATION.
EPAForm3320-l (Rev. 9-88) Previous editions maybe used. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (17-19) MAJOR ADDRESS=P.O. BOX 236/N21 = = = = = = = NJ0005622 482A
_ _ _HANCOCK~RIDGE_,NJ~038_ _ _ _ PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY
- - - - - - - - - - - - - - - - - FROM f-----+---+------1 TOf-----+---+---.,.---;
LOCATION LOWER ALLOWAYS CREEK, NJ 08038 96 07 01 96 07 31 SOUTHERN REGION / SALEM DMRlroMBER~~~ill2~n--onffi- (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
- (3 Card Only) QUANTITY OR LOADING (46-53) (54-61)
(4 Card Only)
(3 8-45)
QUALITY OR CONCENTRATION (46-53) (54-61) NO. FREQ.
PARAMETER r-------.-------.-----+--------.--------,..---------.-----iEX OF SAMPLE (32-37) (62 ANALYSIS TYPE
- UNITS UNITS 63) (64-68) (69-70)
LC50 STATRE 96HR ACU ****** ****** CODE=N ****** ******
CYPRINODON TAN6A 1 0 EFFLUENT GROSS PH 00400 1 0 EFFLUENT GROSS PH 00400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR THRU TREATMENT 50050 1 0 CHLORINE, RESIDUAL 50060 R 0 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 s 0 SEE COMMENTS BELOW 09 935-6000 96 08 16 NUMBER YEAR MO DAY PARAMETER 50060 LOCATIONS: "R" = SWS DSCHG (NO CWS FLOW) 11 S 11 = SWS DSCHG (NORMAL COND)
ENTER 11 NODI 11 FOR LOCATIONS THAT DO NOT APPLY.
WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES PER WEEK DURING 2-HR PERIODS OF CHLORINATION.
EPAForm3320-l(Rev.9-88)Previouseditionsmaybeused. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM {NPDES)
DISCHARGE MONITORING REPORT {DMR)
NAME PSE&G (2-16) (17-19) MAJOR ADDREss-P--:-o-.-BOX236/N2l- - - - - - - NJ0005622 483A
==-HANCOCKSBRIDGE,NJ08038 === PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY FROM 1----+---+---j TOl----t---+----l LOCATION LOWER ALLOWAYS CREEK, NJ 08038 96 07 01 96 07 31 SOUTHERN REGION / SALEM I
-DMR~BER:NJ0005622 483A - -071996- (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
(3 Card Only) QUANTITY OR LOADING (4 Card Only) QUALITY OR CONCENTRATION PARAMETER (46-53) (54-61) (38-45) (46-53) (54-61) NO. FREQ. *
(32-37)
- 1-------~------~---+-------~------~-----~--~EX OF SAMPLE
- (62 ANALYSIS TYPE UNITS UNITS 63) (64-68) (69-70)
LC50 STATRE 96HR ACU ****** ****** ****** ******
CYPRINODON TAN6A 1 0 EFFLUENT GROSS PH 00400 1 0 EFFLUENT GROSS PH 00400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR THRU TREATMENT 50050 1 0 CHLORINE, RESIDUAL 50060 R 0 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 s 0 SEE COMMENTS BELOW NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED 1-----------------<AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GARCHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG- 09 935-6000 96 08 16 NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 USC § 1001 AND r--------------~33 USC § 1319. {Penalties under these statutes may include fines up to AREA TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) CODE NUMBER YEAR MO DAY PARAMETER 50060 LOCATIONS: "R" = SWS DSCHG (NO CWS FLOW) 11 S = SWS DSCHG (NORMAL COND) 11 ENTER "NODI" FOR LOCATIONS THAT DO NOT APPLY.
WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES PER WEEK DURING 2-HR PERIODS OF CHLORINATION.
EPAForm3320-1 {Rev. 9-88) Previous editions maybe used. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) .
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (l7-l9) MAJOR ADDREss-P.o-.-BOX236/N2l - - - - - - - NJ0005622 484A
==-HANCOCKSBRIDGE,NJ08038 === PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY
- - - - - - - - - - - - - - - - - FROM t-----+----+-------l TOt-----+----+------1 LOCATIO~ LOWER ~LLOWAY_E__ CREEK..!....__ NJ _Q__8 0 3 ~ - 96 07 01 96 07 31 SOUTHERN REGION / SALEM DMR NUMBER: NJ0005622 484A 071996 (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
- (3 Card Only) QUANTITY OR LOADING (4 Card Only) QUALITY OR CONCENTRATION PARAMETER (46-53) (54-61) (38-45) (46-53) (54-61) NO. FREQ.
(32-37) r---------.--------.--------+--------,--------.---------.----1EX OF SAMPLE (62 ANALYSIS TYPE UNITS UNITS 63) (64-68) (69-70)
LC50 STATRE 96HR ACU ****** ****** CODE=N ****** ******
CYPRINODON TAN6A 1 0 EFFLUENT GROSS PH 00400 1 0 EFFLUENT GROSS PH 00400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR THRU TREATMENT 50050 1 0 CHLORINE, RESIDUAL 50060 R 0 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 s 0 SEE COMMENTS BELOW NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED t--------------------lAND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GARCHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION NIFICANT s TRUE, ACCURATE PENALTIESAND FORCOMPLETE.
SUBMITTINGI AM AWARE FALSE THAT THERE INCLUDING INFORMATION, ARE SIG- 09 935-6000 96 08 16 THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 use § 1001 AND t--------------------l33 USC § 1319. (Penalties under these statutes may include fines up to YEAR MO DAY TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) NUMBER PARAM:l!:TER 50060 LOCATIONS: 11 R = SWS DSCHG (NO CWS FLOW) 11 11 S = SWS DSCHG (NORMAL COND) 11 ENTER "NODI" FOR LOCATIONS THAT DO NOT APPLY.
WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES PER WEEK DURING 2-HR PERIODS OF CHLORINATION.
EPAForm3320-l(Rev.9-88)Previouseditionsmaybeused. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
=
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (17-19) MAJOR ADDRESS=P.O. BOX 236/N21 = = I NJ0005622 I I 485A
_ _ _HANCOCK~RIDGE_,NJ~038_ _ _ _ I PERMIT NUMBER I !DISCHARGE NUMBER MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION MO I DAY I I YEAR I MO I DAY FROM YEAR I LOCATION LOWER ALLOWAYS CREEK I NJ 0 8 0 3 8 96 I 07 I 01 I TOI 96 I 07 I 31 SOUTHERN REGION / SALEM
-DMR---m.rnBER:NJ0005622 485A - -071996- (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
- (3 Card Only) QUANTITY OR LOADING (4 Card Only) QUALITY OR CONCENTRATION (46-53) (54-61) (38-45) (46-53) (54-61) NO.
PARAMETER
- SAMPLE (32-37)
- TYPE UNITS UNITS (69-70)
LC50 STATRE 96HR ACU ****** ****** CODE=N ****** ******
CYPRINODON TAN6A 1 0 EFFLUENT GROSS PH 00400 1 0 EFFLUENT GROSS PH 00400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR THRU TREATMENT 50050 1 0 EFFLUENT GROSS CHLORINE, RESIDUAL 50060 R 0 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 s 0 SEE COMMENTS BELOW NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED 1----------------lAND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GAR CHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG-NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING 0 9 9 3 5 - 6 0 0 0 9 6 0 8 16 THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 use § 1001 AND r - - - - - - - - - - - - - - - - - < 3 3 USC § 1319. (Penalties under these statutes may include fines up to AREA TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) CODE NUMBER YEAR MO DAY PARAMETER 50060 LOCATIONS: "R" = SWS DSCHG (NO CWS FLOW) "S" = SWS DSCHG (NORMAL COND)
ENTER "NODI" FOR LOCATIONS THAT DO NOT APPLY.
wHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES PER WEEK DURING 2-HR PERIODS OF CHLORINATION.
EPA Form 3320-1 (Rev. 9-88) Previous editions may be used. LABS: 17327 08153 82888 PAGE 1 OF 1
PER!>lITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (17-19) MAJOR ADDRESS=P.O. BOX 236/N21 = = = = = = = NJ0005622 486A
_ _ _HANCOCK~RIDGE_,NJ~038_ _ _ _ PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY
- - - - - - - - - - - - - - - - - FROMt-----+---+------1 TOt-----+---t-----,--1 LOCATION LOWER ALLOWAYS CREEK, NJ 08038 96 07 01 96 07 31 SOUTHERN REGION / SALEM
-DMR~BER~JC>oos622 486A - -071996- (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
(3 Card Only) QUANTITY OR LOADING (4 Card Only) QUALITY OR CONCENTRATION
- (46-53) (54-61) (38-45) (46-53) (54-61) NO. FREQ .
PARAMETER t---------.--------.-----+---------.--------.---------.------1EX OF SAMPLE (32-37) (62 ANALYSIS TYPE UNITS UNITS 63) (64-68) (69-70)
LC50 STATRE 96HR ACU ****** ****** CODE=N ****** ******
CYPRINODON TAN6A 1 0 EFFLUENT GROSS PH 00400 1 0 EFFLUENT GROSS PH 00400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR THRU TREATMENT 50050 1 0 CHLORINE, RESIDUAL 50060 R 0 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 s 0 SEE COMMENTS BELOW NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED t-------------------jAND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GARCHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION NIFICANT s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG-PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING 96 08 16 THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 USC § 1001 AND t-------------------j33 USC § 1319. (Penalties under these statutes may include fines up to NUMBER YEAR MO DAY TYPED OR PRIN'l'ED $10,000 and/or maximum imprisonment of between 6 months and 5 years.)
PARAMETER 50060 LOCATIONS: 11 R = SWS DSCHG (NO CWS FLOW) 11 11 S = SWS DSCHG (NORMAL COND) 11 ENTER "NODI" FOR LOCATIONS THAT DO NOT APPLY.
WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES PER WEEK DURING 2-HR PERIODS OF CHLORINATION.
EPA Form 3320-1 (Rev. 9-88) Previous editions may be used. LABS: 17327 08153 82888 PAGE 1 OF 1
PEfillITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (17-19) #3 OIL SKIM TANK DSN-487B ADDRESS=P.O. BOX 236/N21 = = = = = = = NJ0005622 487B
_ _ _HANCOCK~RIDGE_,NJ~038_ _ _ _ PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MAJOR SALEM FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY SOUTHERN REGION FROM r-----,--+---+----,--j TOr-----+---+------l LOCATION LOWER ALLOWAYS CREEK~NJ 0 8 0 3 S - 96 07 01 96 07 31
-DMRNUMBER:NJ0005622 487B - -071996- (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
(3 Card Only) QUANTITY OR LOADING (4 Card Only) QUALITY OR CONCENTRATION
- (46-53) (54-61) (38-45) (46-53) (54-61) NO .
PARAMETER
- SAMPLE (32-37)
- UNITS UNITS TYPE (69-70)
TEMPERATURE, WATER SAMPLE
- ****** ****** NODI NODI DEG. CENTIGRADE MEASUREMENT 00010 1 0 EFFLUENT GROSS PH 00400 1 0 EFFLUENT GROSS SOLIDS, TOTAL SUSPENDED 00530 1 0 1 0 EFFLUENT EFFLUENT GROSS ****
NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED TELEPHONE DATE t----------------1AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GARCHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG- 09 935-6000 96 08 16 NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 USC § lOOl AND t c c - - - - - - - - - - - - - - - - - 1 3 3 USC § 1319. (Penalties under these statutes may include fines up to AREA TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) CODE NUMBER YEAR MO DAY EPA Form 3320-l (Rev. 9-88) Previous editions may be used. LABS: 17327 08153 82888 PAGE 1 OF 1
PERMITTEE NAME/ADDRESS NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
NAME PSE&G (2-16) (17-19) MAJO'R ADDRESS=P.O. BOX 236/N21 = = = = = = = NJ0005622 489C HANCOCKS BRIDGE, NJ 08038 PERMIT NUMBER DISCHARGE NUMBER
MONITORING PERIOD FACILITY PSE&G SALEM GENERATING STATION YEAR MO DAY YEAR MO DAY FROM t---:--:,--+----+----; TOt---:--:,--+----+-----i LOCATION LOWER ALLOWAYS CREEK, NJ 08038 96 07 01 96 07 31 SOUTHERN REGION / SALEM
-DMR---mfMBER.:NJ0005622 489C - -o?l.996- (20-21) (22-23) (24-25) (26-27) (28-29) (30-31)
- (3 Card Only)
(46-53)
QUANTITY OR LOADING (54-61)
(4 Card Only)
(38-45)
QUALITY OR CONCENTRATION (46-53) (54-61) NO.
PARAMETER SAMPLE (32-37)
- UNITS UNITS TYPE PH ****** ****** 7.8 ****** 7.8 00400 1 0 EFFLUENT GROSS SOLIDS, TOTAL SUSPENDED 00530 1 0 1 0 EFFLUENT EFFLUENT GROSS NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED t - - - - - - - - - - - - - - - - - - - i A N D AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F
- GARCHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG- 09 935-6000 96 08 16 NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 use § 1001 AND t - - - - - - - - - - - - - - - - - - - i 3 3 USC § 1319. (Penalties under these statutes may include fines uKo TYPED OR PRINTED $10,000 and/or maximum imprisonment of between 6 months and 5 years.) NUMBER YEAR MO DAY TOTAL'SUSPENDED SOLIDS SHALL NOT EXCEED A 7-DAY AVERAGE OF 45 MG/L. THIS DISCHARGE IS DESIGNATED AS DS~ 489 IN PERMIT EPA Form 3320-1 (Rev. 9-88) Previous editions may be used. LABS: 17327 08153 82888 PAGE 1 OF 1