ML18100A173

From kanterella
Jump to navigation Jump to search
Response to Request for Additional Information Regarding Exemption Request for Nonconforming Dye Penetrant Examinations of Dry Shielded Canisters (Dscs) 11 Through 15
Date released: 04/12/2018 Download: ML18100A173


Enclosure 13 - Tn Americas LLC Calculation 11042-0207, Revision 1, Nuhoms 61BTH Type 1 DSC Itcp and Otcp Maximum Weld Flaw Evaluation
ML18100A193
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 04/05/2018
From:
Northern States Power Company, Minnesota, TN Americas LLC
To:
Office of Nuclear Material Safety and Safeguards
References
CAC 001028, EPID L-2017-LLE-0029, L-MT-18-013
Download: ML18100A193 (35)
Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear Nuhoms 61BTH Type 1 & 2 Transportable Canister for BWR Fuel
ML18100A191
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 01/30/2014
From: Rich Smith
Northern States Power Company, Minnesota, Structural Integrity Associates, TriVis
To: Becka J
Office of Nuclear Material Safety and Safeguards, Xcel Energy
References
CAC 001028, EPID L-2017-LLE-0029, L-MT-18-013
Download: ML18100A191 (4)
Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records
ML18100A190
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 05/22/2014
From: Rich Smith
Northern States Power Company, Minnesota, Structural Integrity Associates
To:
Office of Nuclear Material Safety and Safeguards
References
CAC 001028, EPID L-2017-LLE-0029, L-MT-18-013
Download: ML18100A190 (52)
Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination
ML18100A188
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 04/11/2013
From:
Northern States Power Company, Minnesota, TriVis
To:
Office of Nuclear Material Safety and Safeguards
References
CAC 001028, EPID L-2017-LLE-0029, L-MT-18-013
Download: ML18100A188 (13)
Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH Nuhoms Canisters
ML18100A185
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 04/11/2013
From:
Northern States Power Company, Minnesota
To:
Office of Nuclear Material Safety and Safeguards
References
CAC 001028, EPID L-2017-LLE-0029
Download: ML18100A185 (30)
Response to Request for Additional Information Regarding Exemption Request for Nonconforming Dye Penetrant Examinations of Dry Shielded Canisters (Dscs) 11 Through 15
ML18100A183
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 04/05/2018
From: O'Connor T
Northern States Power Company, Minnesota, Xcel Energy
To:
Document Control Desk, Division of Spent Fuel Management
References
CAC 001028, EPID L-2017-LLE-0029, L-MT-18-013
Download: ML18100A183 (115)