.e Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1200 Vice President - Nuclear Operations MAR o 1 1991 NLR-N91030 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

RADIOACTIVE EFFLUENT RELEASE REPORT -

29 SALEM GENERATING STATION DOCKET NOS. 50-272 AND 50-311 In accordance with Section 6.9.1.11 of Appendix A to the Operating License for Salem Generating Station (SGS), Public Service Electric and Gas Company (PSE&G) hereby transmits one copy of the semi-annual Radioactive Effluent Release Report, RERR-29.

This report summarizes liquid and gaseous releases and solid waste shipments from the Salem Generating Station for the period July 1 through December 31, 1990.

Should you have any questions regarding this transmittal, please feel free to contact us.

Attachment

(

91 o:3i:i603c.2 90123-1---\\

PDR -Atiocv 05'"'0 R

  • *- C* 027:2 PDR Sincerely,

Document Control Desk NLR-N91030 RERR REPORT only c

Mr. J. c. Stone (1)

Licensing Project Manager Mr. T. Johnson Senior Resident Inspector 2

Mr. T. Martin, Administrator (2)

Region I Mr. K. Tosch, Chief (1)

NJDEP USRNC, Director (1)

Off ice of Nuclear Reactor Regulation Washington, DC. 20555 MAR o 1 1991

SALEM GENERATING STATION SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT SGS RERR-29 SALEM UNIT NOS. 1 & 2 UNIT 1 DOCKET NO. 50-272 UNIT 2 DOCKET NO. 50-311 OPERATING LICENSE NO. DPR-70 OPERATING LICENSE NO. DPR-75 March, 1991

  • sALEM GENERATING STATION RADIOACTIVE EFFLUENT RELEASE REPORT JULY -

DECEMBER 1990 Table of Contents INTRODUCTION................

2 PART A. PRELIMINARY SUPPLEMENTAL INFORMATION 3

1

  • 0 REGULATORY LIMITS 3

1.1 Noble Gas Release Limits.. * * *..

3 1.2 Iodine, Particulates, and Tritium 3

1.3 Liquid Effluents Release Limits 4

1.4 Total Dose Limit. * * *.. * * * *... *.

4 2.0 MAXIMUM PERMISSIBLE CONCENTRATIONS (MPC) 5

3. 0 AVERAGE ENERGY 5

4

  • 0 MEASUREMENTS AND APPROXIMATION OF TOTAL RADIOACTIVITY
  • 5 5. 0 BATCH RELEASES 7

6.0 UNPLANNED RELEASES 7

7.0 ELEVATED R-16/R41C CHANNEL RESPONSES 7

8.0 MODIFICATION TO PREVIOUS RERRS 7

B. GASEOUS EFFLUENTS.

7 art c. LIQUID EFFLUENTS 8

Part D. SOLID WASTE *.

  • Part E. RADIOLOGICAL IMPACT ON MAN Liquid Pathways Air Pathways.............

Direct Radiation..... *. * * *. * * *.

Part F. METEOROLOGICAL DATA *.......

Part G. ODCM CHANGES...........

Part H. INOPERABLE MONITORS.*

Page 1 8

8 8

8 9

9 9

9

INTRODUCTION "SALEM GENERATING STATION RADIOACTIVE EFFLUENT RELEASE REPORT JULY -

DECEMBER 1990 This report, SGS-RERR-29, summarizes information pertaining to the releases of radioactive materials in liquid, gaseous and solid form from the Salem Generating Station (SGS) Units 1 and 2 for the period July 1, 1990 to December 31, 1990.

This Semiannual Radioactive Effluent Release Report (RERR) is submitted for both Salem Units and combines those sections which are common to each unit.

Separate tables of releases and release totals are included.whenever separate processing systems exist.

Salem Unit 1 is a Westinghouse Pressurized Water Reactor which has a licensed core power of 3411 MWt and an approximate net electrical output of 1115 MWe.

Salem Unit 1 achieved initial criticality on December 11, 1976 and went into commercial operations on June 30, 1977.

Salem Unit 2 is a Westinghouse Pressurized Water Reactor which has a licensed core power of 3411 MWt and an approximate net electrical output of 1115 MWe.

Salem Unit 2 achieved initial criticality on August 2, 1980 and went into commercial operations on October 13, 1981.

This report is prepared in the format of Regulatory Guide 1.21, Appendix B, as required by Specification 6.9.1.11 of the Salem Technical Specifications.

Preceding the tables summarizing the gaseous and liquid discharges and solid waste shipments are our responses to parts A-F of the "Supplemental Information" section of Regulatory Guide 1.21, Appendix B.

As required by Regulatory Guide 1.21, our Technical Specification limits are described in detail within this report along with a summary description of how measurements and determinations of the total activity discharged were developed.

To facilitate determination of compliance with 40CFR190 requirements, the following information on electrical output is provided:

Unit 1 generated 3,209,274 megawatt-hours of electrical energy (net) during the reporting period.

Page 2

Unit 2 generated 4,084,649 megawatt-hours of electrical energy (net) during the reporting period.

Results of liquid and gaseous composites analyzed for Sr-89, sr-90 and Fe-55 for the fourth quarter of 1990 were not available for inclusion in this report.

The results of these composites will be provided in the next Radioactive Effluent Release Report.

The Sr-89, Sr-90 and Fe-55 analyses for the first half of 1990 (refer to RERR-28) have been completed; amended pages to RERR-28 are included in this report.

PART A. PRELIMINARY SUPPLEMENTAL INFORMATION 1.0 REGULATORY LIMITS 1.1 Noble Gas Release Limits The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the site boundary, shall be limited to the following:

For noble gases:

Less than or equal to 500 mrems/yr to the total body and less than or equal to 3000 mrems/yr to the skin.

In addition, the air dose due to noble gases released in gaseous effluents, from each reactor unit, from the site to areas at and beyond the site boundary, shall be limited to the following:

During any calendar quarter:

Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation, and During any calendar year:

Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.

1.2 Iodine, Particulates, and Tritium The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the site boundary, shall be limited to the following:

Page 3

For Iodine-131, for tritium, and for all radionuclides in particulate form with half lives greater than 8 days:

Less than or equal to 1500 mrems/yr to any organ.

In addition, the dose to a member of the public from iodine-131, from tritium, and from all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, from each reactor unit, from the site to areas at and beyond the site boundary, shall be limited to the following:

During any calendar quarter:

Less than or equal to 7.5 mrems to any organ~ and During any calendar year:

Less than or equal to 15 mrems to any organ.

1.3 Liquid Effluents Release Limits 1.4 The concentration of radioactive material released in liquid. effluents to unrestricted areas shall be limited to the concentrations specified in 10CFR20, Appendix B, Table II, Column 2 for radionuclides other than dissolved or entrained noble gases.

For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 microcuries per milliliter.

In addition, the dose or dose commitment to a member of the public from radioactive materials in liquid effluents released to unrestricted areas shall be limited:

During any calendar quarter to less than or equal to 1.5 mrems to the total body and to less than or equal to 5 mrems to any organ, and During any calendar year to less than or equal to 3 mrems to the total body and to less than or equal to 10 mrems to any organ.

Total Dose Limit The annual (calendar year) dose or dose commitment to any member of the public, due to releases of radioactivity and radiation, from uranium fuel cycle sources shall be limited to less than or equal to 25 mrems to the total body or any organ (except the thyroid, which shall be limited to less than or equal to 75 mrems)

  • Page 4

.O MAXIMUM PERMISSIBLE CONCENTRATIONS (MPC)

Regulatory Guide 1.21 requires that the licensee provide the MPCs used in determining allowable release rates for radioactive releases.

a.

MPC values were not used to determine the maximum release rates for fission gases, iodines, or particulates.

b.

MPC values as stated in 1CFR20, Appendix B, Table II, Column 2 were used for liquids.

c.

MPC value used for dissolved or entrained noble gases was 2E-4 microcuries per milliliter.

3.0 AVERAGE ENERGY Regulatory Guide 1.21 requires that the licensee provide the average energy of the radionuclide mixture in releases of fission and activation gases, if applicable.

Release limits for SGS are not based upon average energy, hence, this section does not apply.

MEASUREMENTS AND APPROXIMATION OF TOTAL RADIOACTIVITY 4.1 4.2 Liquid effluent streams are monitored and sampled in accordance with Table 4.11-1 of the Technical Specifications.

During the period of record, all wastes from the chemical drain tank, the laundry, and hot shower tanks were routed to the hold-up tanks for monitoring prior to release.

Technical Specifications require these tanks to be uniformly mixed for sampling and analysis before being released.

Batch releases are defined as releases from the waste monitor hold-up tanks and the chemical and volume control system.

Continuous liquid releases are defined as condensate releases from intermittent blowdown of the steam generators.

The preponderant gamma emitting nuclides detected in sampling were Co-58, Co-60 and Mn-54.

Specific activities from analyses were multiplied by the volume of effluent discharged to the environment in order to calculate the total liquid activity discharged.

Gaseous effluent streams are monitored and sampled in accordance with Table 4.11-2 of the Technical Specifications.

The plant vent is the final release point of all planned gaseous effluents and is continuously monitored by beta scintillators and high Page 5

range GM tubes.

Also, the vent is sampled continuously for iodine and particulates with a carbon cartridge and filter*

paper connected in series to a low volume air sampler.

The filters are changed weekly and analyzed on a multi-channel analyzer.

Sampling is also performed on all gas decay tanks and containment purges prior to their release to the environment.

The plant vent is sampled for noble gases monthly.

The detection requirements (LLDs) of Tables 4.11-1 and 4.11-2 of the Technical Specifications are achieved or exceeded.

Radionuclides for which no activity was detected while meeting the LLDs are.treated as absent.

Continuous Mode gaseous releases are quantified by routine (monthly or weekly) sampling and isotopic analyses of the plant vent.

Specific activities for each nuclide detected are multiplied by the total vent flow volume for the entire sampling period in order to calculate the normal continuous release of radioactivity through the plant vent.

Slightly elevated plant vent radiation monitor readings are treated as continuous releases.

The monitor's response is converted to a "specific activity" using historical efficiency factors.

The "specific activity" is multiplied by a default volume of effluent discharge to estimate the total activity discharged.

Batch Mode gaseous releases are quantified by sampling each gas decay tank or containment purge prior to discharge.

Specific activities for each nuclide are multiplied by the total volume of gas discharged.

Elevated plant vent radiation monitoring system readings, while the channel is in an alarm state, are treated as batch mode releases. If specific activity data from grab samples are not available, then the abnormal release is quantified by the use of the plant vent radiation monitors.

The monitor's response is converted to a "specific activity" using historical efficiency factors.

The "specific activity" is multiplied by the volume of effluent discharged while the channel was in an alarm state in order to estimate the total activity discharged.

4.3 The estimated total error of reported liquid releases is within 25%.

Page 6

The estimated total error of the reported continuous gaseous releases is within 50% when concentrations exceed detectable levels.

This error is due primarily to variability of waste stream flow rates and changes in isotopic distributions of waste streams between sampling periods.

The estimated total error of the reported batch gaseous releases is within 10%.

Error estimates for releases where sample activity is below the detectable concentration levels (MDA) are not included since error estimates at the MDA are not defined.

The estimated total error of reported solid releases is within 25%.

5.0 BATCH RELEASES Summaries of batch releases of gaseous and liquid effluents are provided in Tables 4A-l and 4B-1 for Unit 1 and 4A-2 and 4B-2 for Unit 2.

6.0 UNPLANNED RELEASES During this reporting period there were no unplanned releases.

  • O ELEVATED R-16/R41C CHANNEL RESPONSES During this reporting period, the plant vent radiation monitors indicated slightly elevated readings on several occasions.

As indicated above, elevated R16/R41C readings were quantified and treated as continuous releases.

It was assumed that they were Xe-133, since it the preponderant nuclide released.

The elevated readings are included in Tables lB-1 and lB-2.

8.0 MODIFICATION TO PREVIOUS RERRS Our last report (RERR-28) did not include the second quarter Sr-89, Sr-90 and Fe-55 composite data for the first half of 1990.

Amended pages to RERR-28 are included at the end of this report.

Part B. GASEOUS EFFLUENTS See Summary Tables lA-1 thru lC for Salem Unit 1 Operations.

See Summary Tables lA-2 thru lC for Salem Unit 2 Operations.

Page 7

~art c. LIQUID EFFLUENTS Summary Tables thru for Salem Unit operations.

See 2A-1 2C 1

See Summary Tables 2A-2 thru 2C for Salem Unit 2 Operations.

Part D. SOLID WASTE See Summary in Table 3.

Part E. RADIOLOGICAL IMPACT ON MAN The calculated individual doses in this section are based on actual locations of nearby residents and farms.

The population dose impact is based on historical site specific data i.e., food production, milk production, feed for milch animals and seafood production.

The doses were calculated using methods described in Regulatory Guide 1.109 and represent calculations for the six month reporting interval.

Individual doses from batch and continuous releases were calculated using the annual average historic meteorological dispersion coefficients* as described in the Offsite Dose Calculation Manual.

Population doses were calculated using the meteorological dispersion coefficients for the six month reporting interval.

Liquid Pathways Doses to individuals in the population from liquid releases are primarily from the seafood ingestion pathway.

The total body dose to an individual was calculated to be 1.59E-Ol mrem.

The calculated highest organ dose from liquid releases was 1.15E+OO mrem to the GI-LLI.

The calculated population total body dose was 8.20E-02 person-rem.

The calculated average total body dose to the population within fifty miles of the site was 1.37E-05 mrem/person.

Air Pathways The resulting total body and skin doses to an individual were calculated to be 6.84E-03 mrem and 1.64E-02 mrem respectively.

The calculated highest organ dose due to radioiodines and particulates with at greater than eight day half-life was 3.27E-03 mrem to the thyroid.

The calculated population total body dose was 1.50E-Ol person-rem.

The calculated average total body dose to the population within fifty miles of the site was 2.SOE-05 mrem/person.

Page 8

Direct Radiation Direct radiation may be estimated by Thermoluminescent

-Dosimetric (TLD) measurements.

One method for comparing TLD measurements is by comparison with preoperational data. It should be noted that the TLDs measure direct radiation from both the Salem and Hope Creek Generating stations at Artificial Island.

TLDs at onsite locations 2s-2 and ss-1, which are 0.3 miles and 0.9 miles from the point of origin, averaged 4.9 and 4.2 mrads/month respectively.

The values for stations 2S-2 and SS-1 are within the statistical variation associated with the preoperational program results.

It should be noted the nearest resident is 3.5 miles away.

It can thus be concluded that there is no measurable dose to any offsite location from direct radiation.

Part F. METEOROLOGICAL DATA Cumulative joint wind frequency distributions by atmospheric stability class at the 300 foot elevation are provided for the third and fourth quarters of 1990 in Tables 5 and 6.

art G. ODCM CHANGES During the report period, there were no changes to the Salem Generating Statio*n Off-Site Dose Calculation Manual.

Part H. INOPERABLE MONITORS Between the period* of July 1, and December 31, 1990, there were three instances of radioactive effluent monitors being out of service for periods greater than 30 days.

Per Salem Technical Specification 3.3.3.8, an explanation for the inoperability not being corrected within 30 days is given below:

On August 2, 1990 the number 14 steam generator blowdown radiation monitor (l-R19D) flow indicator was determined inoperable due to positive flow indication while Unit 1 was in cold shutdown and blowdown flow secured.

Maintenance work was done on the flow indicator on August 17.

The operability retest could not be performed within 30 days of the monitor being declared inoperable per Technical Specification 3.3.3.8, due to the shutdown with no steam generator blowdown flow.

On September 4, 1990, during plant heatup, the flow indicator was successfully tested for operability

  • Page 9

On June 23, 1990, the number 22 steam generator blowdown radiation monitor {2-Rl9B) was determined to be inoperable due to erratic response of the meter.

Maintenance work was done on the monitor on June 27.

The operability retest could not be performed within 30 days of the monitor being declared inoperable per Technical Specification 3.3.3.8, because Unit 2 was shutdown with no steam generator blowdown flow.

On September 5, 1990, with the plant at power, the radiation monitor was successfully tested for operability.

on June 28, 1990, the number 21, 23, and 24 steam generator blowdown radiation monitor {2-R19A, c, D) flow indicators were determined to be inoperable due to indications of low flow.

Unit 2 was in a maintenance shutdown with steam generator blowdown secured.

Technical Specification 3.3.3.8 requires that the steam generator blowdown radiation monitors be operable at all times.

No corrective maintenance work was required on the flow indicators.

An operability retest could not be performed within 30 days of the monitors being declared inoperable per Technical Specification 3.3.3.8 because Unit 2 was shutdown with no steam generator blowdown flow.

on September 5, 1990, with the plant at power, the radiation monitors were successfully tested for operability

  • Page 10

SALEM GENERATING STATION TABLE lA-1 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 UNIT 1 GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES 3rd Quarter 4th Est. (1)

Units A. -Fission and Activation Gases

1. Total release Ci 1.21E+02
2. Average release rate for period uci/sec 1.53E+Ol
3. Percent of technical specification limit (T.S. 3.11.2.2(a))

9.lOE-02 B. Iodines

1. Total iodine-131 Ci 1.26E-04 rate for period uci/sec 1.60E-05
2. Average release
3. Percent of technical specification limit (2)

(T.S. 3.ll.2.3(a))

6.39E-03

c. Particulates
1. Particulates with half-lives >8 days Ci 1.04E-05
2. Average release rate for period uci/sec 1.32E-06
3. Percent of technical specification limit (2)

(T.S. 3.11.2.3(a))

6.39E-03

4. Gross alpha Ci O.OOE+OO C. Tritium
1. Total Release Ci 1.83E+Ol
2. Average release rate for period uci/sec 2.32E+OO
3. Percent of technical specification limit (2)

(T.S. 3.11.2.3(a))

6.39E-03 (1) For batch releases the est;mated overall error ;s w;th;n 10X

~2> lod;ne,,,;,;.., ond po,t;oulotos *~ "'"' o gcoup Page 11 Quarter Total.

1.10E+02

1. 40E+Ol 8.22E-02 6.72E-07 8.55E-08 2.07E-04 O.OOE+OO O.OOE+OO 2.07E-04 O.OOE+OO 6.47E+OO 8.23E-Ol 2.07E-04 Error %

25 25 25 25

SALEM GENERATING STATION TABLE 1A-2 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 UNIT 2 GASEOUS EFFLUENTS-SUMMATION OF ALL 3rd Units Quarter A. Fission and Activation Gases

1. Total release Ci 3.28E+OO
2. Average release rate for period uCi/sec 4.17E-01
3. Percent of technical specification limit (T.S. 3.ll.2.2(a))

~

0 2.41E-03 B. Iodines

1. Total iodine-131 Ci O.OOE+OO
2. Average release rate for period uci/sec O.OOE+OO
3. Percent of technical specification limit (2)

(T.S. 3.11.2.J(a))

1. 70E-04
c. Particulates
1. Particulates with half-lives >8 days Ci 2.63E-06
2. Average release rate for period uci/sec 3.35E-07
3. Percent of technical specification limit (2)

(T.S. 3.11.2.J(a))

1.70E-04

4. Gross alpha Ci O.OOE+OO
c. Tritium
1. Total Release Ci 6.15E+OO
2. 'Average release rate for period uci/sec 7.82E-01
3. Percent of technical specification limit (2)

(T.S. 3.11.2.J(a))

1.70E-04 C1) For batch releases the estimated overall error is within 10X (2) Iodine, tritiun and particulates are treated as a group Page 12 RELEASES 4th Quarter 8.29E+01 1.05E+01 6.07E-02 O.OOE+OO O.OOE+OO 1.55E-04 O.OOE+OO O.OOE+OO 1.55E-04 O.OOE+OO 5.71E+OO 7.26E-01 1.55E-04 Est.

Total Error 25 25 25 25

. *SALEM GENERATING STATION TABLE 1B-1 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 GASEOUS EFFLUENTS-ELEVATED RELEASES UNIT 1 CONTINUOUS MODE BATCH MODE 3rd 4th 3rd 4th Nuclides Released Units Quarter Quarter Quarter Quarter

1. Fission Gases Krypton-85 Ci O.OOE+OO O.OOE+OO 5.15E-01 4.0lE-01 Krypton-85m Ci O.OOE+OO O.OOE+OO 1.39E-02
1. 45E-02 Krypton-88 Ci O.OOE+OO O.OOE+OO 1.0BE-03 5.92E-03 Xenon-13 lm.

Ci O.OOE+OO O.OOE+OO 9.03E-01 8.93E-Ol Xenon-133 Ci 2.73E+Ol 1.67E+Ol 8.86E+Ol 8.95E+Ol Xenon-133m Ci O.OOE+OO O.OOE+OO 1.10E+OO 1.09E+OO Xenon-135 Ci 6.20E-Ol 6.47E-Ol 1.40E+OO 5.38E-01 Argon-41 Ci O.OOE+OO O.OOE+OO O.OOE+OO 3.74E-04 Totals Ci 2.79E+Ol 1.73E+01 9.26E+Ol 9.24E+Ol

. Iodines Iodine-131 Ci

1. 26E-04 6.72E-07 O.OOE+OO O.OOE+OO Totals Ci l.26E-04 6.72E-07 O.OOE+OO O.OOE+OO
3. Particulates I

(half-live >8 days 1

Cobalt-58 Ci 3.59E-06 O.OOE+OO O.OOE+OO

0. OOE+OO
  • Cobalt-60 Ci 6.78E-06 O.OOE+OO O.OOE+OO O.OOE+OO Totals Ci 1.04E-05 O.OOE+OO O.OOE+OO O.OOE+OO Page 13

. *SALEM GENERATING STATION TABLE lB-2 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 GASEOUS EFFLUENTS-ELEVATED RELEASES UNIT 2 CONTINUOUS MODE BATCH MODE 3rd 4th 3rd 4th Nuclides Released Units Quarter Quarter Quarter Quarter

1. Fission Gases Kr}rpton-85 Ci O.OOE+OO O.OOE+OO 9.46E-03 O.OOE+OO Xenon-131m Ci O.OOE+OO O.OOE+OO 2.31E-02 2.95E-02 Xenon-133 Ci 1.lOE+OO 8.00E+Ol 2.13E+OO 2.82E+OO Xenon-133m Ci O.OOE+OO O.OOE+OO 1.00E-02 1.56E-02 Xenon-135 Ci O.OOE+OO O.OOE+OO 3.74E-03 4.23E-03 Totals Ci
1. lOE+OO 8.00E+Ol 2.18E+OO 2.87E+OO
2..Iodines Iodine-131 Ci O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Totals Ci O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO
3. Particulates (half-live >8 days Cobalt-58 Ci 1.33E-06 O.OOE+OO O.OOE+OO O.OOE+OO Cobalt-60 Ci
1. 30E-06 O.OOE+OO O.OOE+OO O.OOE+OO Totals Ci 2.63E-06 O.OOE+OO O.OOE+OO O.OOE+OO Page 14
    • SALEM GENERATING STATION TABLE lC EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 UNITS 1 AND 2 GASEOUS EFFLUENTS-GROUND-LEVEL RELEASES CONTINUOUS MODE BATCH MODE 3rd.

Nuclides Released Unit Quarter 4th Quarter 3rd Quarter 4th Quarter There were no ground level gaseous releases during this reporting period.

Page 15

"SALEM GENERATING STATION TABLE 2A-l EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 UNIT 1 LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES 4th Units 3rd Quarter Quarter Est. Total Error %

A. Fission and activation products

1. Total release (not including tritium, gases, alpha) (1)

Ci

2. Average diluted concentration during period uCi/ml
3. Percent of technical specification limit (T.S. 3.11.1.2.(a))

B. Tritium

1. Total release Ci
2. Average diluted concentration during period uCi/ml
3. Percent of technical specification limit (T. S. 3.11.. 1.1)
c. Dissolved and entrained noble gases
1. Total release Ci
2. Average diluted concentration during period uCi/ml
3. Percent of technical specification limit (T.S. 3.11.1.1)

D. Gross alpha activity

1. Total release (2)

Ci E. Volume of waste release (prior to dilution -

Batch Release) liters F. Volume of dilution water 9.66E-Ol 8.45E-08 9.0GE+OO 5.09E+Ol 4.45E-06 l.48E-Ol 3.95E-02 3.45E-09

1. 73E-03 O.OOE+OO 2.75E+06 used during entire period liters l.14E+l0 C1> For batch releases the estimated overall error is within 10X
2) Iodine, tritilln and particulates are treated as a group Page 16 3.40E-Ol 25 4.lGE-08 2.13E+OO l.04E+02 25 l.27E-05 4.23E-Ol l.39E-Ol 25 l.70E-08 8.SlE-03 O.OOE+OO 2.16E+06 8.19E+09

.

  • SALEM GENERATING STATION TABLE 2A-2 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 UNIT 2 LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES 4th Units 3rd Quarter Quarter Est. Total Error %

A. Fission and activation products

1. Total release (not including tritium, gases, alpha) (1)

Ci

2. Average diluted*

concentration during period uci/ml

3. Percent of technical sp~cification limit (T.S. 3.11.1.2.(a))

B. Tritium

1. Total release Ci
2. Average diluted concentration during period uCi/ml
3. Percent of technical specification limit (T.S. 3.11.1.1)
c. Dissolved and entrained noble gases
1. Total release Ci
2. Average diluted concentration during period uCi/ml
3. Percent of technical specification limit (T.S. 3.11.1.1) 1.06E+OO 1.14E-07 9.30E+OO 4.89E+Ol 5.27E-06
1. 76E-Ol 2.63E-02 2.83E-09
1. 42E-03 D. Gross alpha activity
1. Total release (2)

Ci O.OOE+OO E. Volume of waste release (prior to dilution -

Batch Release)

F. Volume of dilution water liters 2.54E+06 used during entire period liters 9.29E+09

1) For batch releases the estimated overall error is within 10X.
2) Iodine, tritii.n and particulates are treated as a group Page 17 3.40E-Ol 25 4.75E-08 2.50E+oo 9.40E+Ol 25 1.32E-05 4.38E-Ol 1.0SE-01 25 1.51E-08 7.55E-03 O.OOE+OO 1.83E+06 7.15E+09
  • . SALEM GENERATING STATION TABLE 2B-1 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 LIQUID EFFLUENTS UNIT 1 CONTINUOUS MODE BATCH MODE 3rd 4th 3rd 4th Nuclides Released Units Quarter Quarter Quarter Quarter Sodium-24 Ci O.OOE+OO O.OOE+OO 5.04E-04 5.34E-04 Chromium-51 Ci O.OOE+OO O.OOE+OO 5.24E-03 6.47E-04 Manganese-54 Ci O.OOE+OO O.OOE+OO 3.25E-02 5.62E-03 Iron-55 Ci O.OOE+OO O.OOE+OO 3.85E-02 O.OOE-00 Cobalt-57 Ci O.OOE+OO O.OOE+OO 2.52E-03

1. 45E-03 Cobalt-58 Ci O.OOE+OO O.OOE+OO 6.22E-Ol 1.85E-Ol Iron-59 Ci O.OOE+OO O.OOE+OO 3.63E-04 2.86E-05 Cobalt-60 Ci O.OOE+OO O.OOE+OO 8.58E-02 6.29E-02 Zinc-65 Ci O.OOE+OO O.OOE+OO 2.44E-04 O.OOE-00 Strontium-89 Ci O.OOE+OO O.OOE+OO
1. 79E-04 O.OOE-00 Strontium-90 Ci O.OOE+OO O.OOE+OO 8.24E-05 o*. OOE-00 Niobium-95 Ci O.OOE+OO O.OOE+OO 8.lOE-03 1.llE-03 Zirconium-95 Ci O.OOE+OO O.OOE+OO 4.0lE-03 4.38E-04 Technetium-99m Ci O.OOE+OO O.OOE+OO 9.73E-06 3.90E-05 ilver-llOm Ci O.OOE+OO O.OOE+OO 3.68E-04 O.OOE-00 in-113 Ci O.OOE+OO O.OOE+OO 2.59E-04 O.OOE+OO Antimony-122 Ci O.OOE+OO O.OOE+OO O.OOE-00 5.06E-05 Antimony-124 Ci O.OOE+OO O.OOE+OO 2.32E-03 3.99E-04 Antimony-125 Ci O.OOE+OO O.OOE+OO
1. 41E-02 5.18E-03 Iodine-131 Ci O.OOE+OO O.OOE+OO 6.27E-03 3.84E-03 Iodine-133 Ci O.OOE+OO O.OOE+OO 6.75E-04 1.69E-03 Cesium-134 Ci O.OOE+OO O.OOE+OO 4.24E-02 3.39E-02 Cesium-136 Ci O.OOE+OO O.OOE+OO 1.07E-04 O.OOE+OO Cesium-137 Ci O.OOE+OO O.OOE+OO 4.38E-02 3.74E-02 Cerium-144 Ci O.OOE+OO O.OOE+OO 5.82E-05 O.OOE+OO TOTALS Ci O.OOE-00 O.OOE-00 9.66E-Ol 3.40E-Ol Tritium Ci O.OOE+OO O.OOE+OO 5.09E+Ol 1.04E+02 Krypton-87 Ci O.OOE+OO O.OOE+OO 1.41E-05 O.OOE-00 Xenon-131m Ci O.OOE+OO O.OOE+OO O.OOE-00 2.72E-04 Xenon-133m Ci O.OOE+OO O.OOE+OO 1.64E-04 3.45E-04 Xenon-133 Ci O.OOE+OO O.OOE+OO 3.91E-02
1. 38E-Ol Xenon-135 O.OOE+OO O.OOE+OO 2.36E-04 7.55E-04 TOTALS Ci O.OOE+OO O.OOE+OO 5.09E+Ol 1.04E+02 Page 18

. *SALEM GENERATING STATION TABLE 2B-2 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 LIQUID EFFLUENTS UNIT 2 CONTINUOUS MODE BATCH MODE 3rd 4th 3rd 4th Nuclides Released Units Quarter Quarter Quarter Quarter Sodium-24 Ci O.OOE+OO O.OOE+OO 1.22E-04 2.68E-04 Chromium-51 Ci O.OOE+OO O.OOE+OO 4.60E-03 1.99E-04 Manganese-54 Ci O.OOE+OO O.OOE+OO 3.BlE-02 6.07E-03 Iron-55 Ci O.OOE+OO O.OOE+OO 8.89E-02 O.OOE-00 Cobalt-57 Ci O.OOE+OO O.OOE+OO 2.60E-03 1.71E-03 Cobalt-58 Ci O.OOE+OO O.OOE+OO 6.40E-Ol 1.79E-Ol Iron-59 Ci O.OOE+OO O.OOE+OO 3.52E-04 O.OOE-00 Cobalt-60 Ci O.OOE+OO O.OOE+OO 6.96E-02 7.20E-02 Zinc-65 Ci O.OOE+OO O.OOE+OO 1.09E-04 3.51E-04 Strontium-89 Ci O.OOE+OO O.OOE+OO 1.70E-04 O.OOE+OO Strontium-90 Ci O.OOE+OO O.OOE+OO 8.64E-05 O.OOE+OO Niobium-95 Ci O.OOE+OO O.OOE+OO 6.62E-03 1.89E-03 irconium-95 Ci O.OOE+OO O.OOE+OO 3.48E-05 8.43E-04 admium-109 Ci O.OOE+OO O.OOE+OO 1.76E-04 O.OOE+OO Silver-llOm Ci O.OOE+OO O.OOE+OO 1.39E-04 9.34E-04 Tin-113 Ci O.OOE+OO O.OOE+OO 2.14E-04 1.llE-04 Antimony-122 Ci O.OOE+OO O.OOE+OO 6.50E-05 O.OOE+OO Antimony-124 Ci O.OOE+OO O.OOE+OO 3.14E-o3* 6.52E-04 Antimony-125 Ci O.OOE+OO O.OOE+OO 1.79E-02 9.16E-03 Iodine-131 Ci O.OOE+OO O.OOE+OO l.OBE-02 3.99E-03 Iodine-133 Ci O.OOE+OO O.OOE+OO 3.47E-04 1.09E-03 Cesium-134 Ci O.OOE+OO O.OOE+OO 5.67E-02 2.92E-02 Cesium-136 Ci O.OOE+OO O.OOE+OO 4.0lE-04 5.33E-05 Cesium-137 Ci O.OOE+OO O.OOE+OO 5.77E-02 3.lBE-02 Lanthanum-140 Ci O.OOE+OO O.OOE+OO 3.14E-05 1.12E-05 TOTALS Ci O.OOE+OO O.OOE+OO 1.06E+OO 3.40E-Ol Tritium Ci O.OOE+OO O.OOE+OO 4.89E+Ol 9.40E+Ol Xenon-131m Ci O.OOE+OO O.OOE+OO O.OOE+OO 9.02E-04 Xenon-133m Ci O.OOE+OO O.OOE+OO O.OOE+OO 7.43E-04 Xenon-133 Ci O.OOE+OO O.OOE+OO 2.59E-02 1.06E-Ol Xenon-135 Ci O.OOE+OO O.OOE+OO 3.49E-04 4.26E-04 TOTALS Ci O.OOE+OO O.OOE+OO 4.89E+Ol 9.40E+Ol Page 19

  • . SALEM GENERATING STATION TABLE 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 UNITS 1 AND 2 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)

1.

Type of waste Units ( 1) 6-month period Est. Total Error, %

a.

Spent resins, filters, m3 12.6 sludges, evaporator bottoms Ci 143 25

b.

Dry compressible waste, m3 30.5 contaminated equipment.

Ci 0.62 25

c.

Irradiated components, m3 0

control rods Ci 0

25

d.

Others (described) m3 0

Ci 0

25 Estimate of major nuclide composition (for Type A and B waste)

Tritium -

3 Iron -

55 Manganese -

54 Cobalt -

58 Cobalt -

60 Nickel -

63 Cesium -

134 Cesium -

137 Cerium -

144 Plutonium -

241

(%)

o.o 21.6 5.0 56.4 8.3 5.8 1.4 1.5 0.0 o.o Resin DAW (Ci)

O.OOE+OO 3.09E+Ol 7.15E+OO 8.07E+Ol 1.19E+Ol 8.29E+OO 2.00E+OO 2.15E+OO O.OOE+OO O.OOE+OO

(%)

0.1 15.7 1.2 56.6 9.4 9.1 2.1 4.2 0.2 1.2 (1)

Volumes are measured, activities are estimated Page 20 (Ci) 6.19E-04 9.72E-02 7.42E-03 3.49E-Ol 5.81E-02 5.63E-02 1.30E-02 2.61E-02 1.24E-03 7.43E-03

. *SALEM GENERATING STATION TABLE 3 (CONT'D)

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990 UNITS 1 AND 2 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS

3.

Solid Waste Disposition Number of Mode of Type of Shipments Transportation Destination Containers 3

Truck Barnwell, SC HIC 6

Truck Barnwell, SC Strong, tight container

4.

IRRADIATED FUEL SHIPMENTS (Disposition)

Number of Shipments None Mode of Transportation N/A Page 21 Destination N/A

    • sALEM GENERATING STATION TABLE 4A-l EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE UNIT 1 BATCH RELEASES ONLY

1.

Dates:

July 1 - September 30, 1990

2.

Type of release:

Gas

3.

Number of releases during the 3rd Quarter:

64

4.
5.
7.
8.

Total time duration for all releases of type listed above:

2.84E+04 minutes Maximum duration for release of type listed above:

1.80E+04 minutes Average duration for release of type listed above:

4.43E+02 minutes Minimum duration for release of type listed above:

2.00E+Ol minutes Average stream flow (dilution flow) during the period of release:

N/A Page 22

SALEM GENERATING STATION TABLE 4A-1 (CONT'D)

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE UNIT 1 BATCH RELEASES ONLY

1.

Dates:

October 1 -

December 31, 1990

2.

Type of release:

Gas

3.

Number of releases during the 4th Quarter:

42

4.

Total time duration for all releases of type listed above:

3.73E+03 minutes

5.

Maximum duration for release of type listed above:

5.57E+02 minutes

6.

Average duration for release of type listed above:

8.89E+Ol minutes

7.

Minimum duration for release of type listed above:

6.00E+OO minutes

8.

Average stream flow (dilution flow) during the period of release:

N/A Page 23

SALEM GENERATING STATION TABLE 4A-2 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE UNIT 2 BATCH RELEASES ONLY

1.

Dates:

July 1 - September 30, 1990

2.

Type of release:

Gas

3.

Number of releases during the 3rd Quarter:

35

4.
5. **
7.
8.

Total time duration for all releases of type listed above:

8.22E+03 minutes Maximum duration for release of type listed above:

5.25E+03 minutes Average duration for release of type listed above:

2.35E+02 minutes Minimum duration for release of type listed above:

3.80E+Ol minutes Average stream flow (dilution flow) during the period of release:

N/A Page 24

SALEM GENERATING STATION TABLE 4A-2 (CONT'D)

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE UNIT 2 BATCH RELEASES ONLY Dates:

October 1 -

December 31, 1990

2.

Type of release:

Gas

3.

Number of releases during the 4th Quarter:

20

4.

Total time duration for all releases of type listed above:

l.81E+03 minutes Maximum duration for release of type listed above:

1.34E+02 minutes

6.

Average duration for release of type listed above:

9.0GE+Ol minutes

7.

Minimum duration for release of type listed above:

6.40E+Ol minutes

a.

Average stream flow (dilution flow) during the period of release:

N/A Page 25

SALEM GENERATING STATION TABLE 4B-1 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE UNIT 1 BATCH RELEASES ONLY

1.

Dates:

July 1 -

September 30, 1990

2.

Type of release:

Liquid

3.

Number of releases during the 3rd Quarter:

44

4.

Total time duration for all releases of type listed 1.09E+04 minutes Maximum duration for release of type listed above:

3.58E+02 minutes

6.

Average duration for release of type listed above:

2.47E+02 minutes

7.

Minimum duration for release of type listed above:

2.18E+02 minutes above:

8.

Average stream flow (dilution flow) during the period of release: 2.78E+05 gpm Page 26

.. SALEM GENERATING STATION TABLE 4B-1 (CONT ID)

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE UNIT 1 BATCH RELEASES ONLY

1.

Dates:

October 1 -

December 31, 1990

2.

Type of release:

Liquid

3.

Number of releases during the 4th Quarter:

34

4.

Total time duration for all releases of type listed above:

8.34E+03 minutes

5.

Maximum duration for release of type listed above:

3.06E+02 minutes Average duration for release of type listed above:

2.45E+02 minutes

7.

Minimum duration for release of type listed above:

2.15E+02 minutes

8.

Average stream flow (dilution flow) during the period of release: 2.59E+05 gpm Page 27

. *sALEM GENERATING STATION TABLE 4B-2 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE UNIT 2 BATCH RELEASES ONLY

1.

Dates:*

July 1 -

September 30, 1990

2.

Type of release:

Liquid

3.

Number of releases during the 3rd Quarter:

41

4.

Total time duration for all releases of type listed above:

l.05E+04 minutes

5.

Maximum duration for release of type listed above:

3.37E+02 minutes Average duration for release of type listed above:

2.55E+02 minutes

7.

Minimum duration for release of type listed above:

l.50E+02 minutes

8.

Average stream flow (dilution flow) during the period of release: 2.35E+05 gpm Page 28

. *SALEM GENERATING STATION TABLE 4B-2 (CONT'D)

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JULY -

DECEMBER 1990

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE UNIT 2 BATCH RELEASES ONLY

1.

Dates:

October 1 -

December 31, 1990

2.

Type of release:

Liquid

3.

Number of releases during the 4th Quarter:

29

4.
5.
7.
8.

Total time duration for all releases of type listed above:

7.11E+03 minutes Maximum duration for release of type listed above:

3.32E+02 minutes Average duration for release of type listed above:

2.45E+02 minutes Minimum duration for release of type listed above:

l.08E+02 minutes Average stream flow (dilution flow) during the period of release: 2.66E+05 gpm Page 29

ARTIFICIAL ISLAND 7/90 - 9/90 0.0-0.5 0.6-3.5 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

WIND SPEED GROJPS (MPH) 3.6-7.5 7.6-12.5 12.6-18.5 DIRECTION sut PERCENT sut PERCENT sut PERCENT SUM PERCENT sut PERCENT N

0 o.o 0

o.o NNE 0

0.0 0

0.0 NE 0

0.0 0

0.0 ENE 0

0.0 0

0.0 E

0 0.0 0

o.o ESE 0

0.0 0

o.o SE 0

o.o 0

o.o SSE 0

o.o 0

0.0 s

0 o.o 0

o.o ssu 0

o.o 0

0.0 SU 0

o.o 0

o.o YSU 0

0.0 2

o.,

w 0

0.0 0

0.0 WNW 0

o.o 0

0.0 NW 0

0.0 0

0.0 NNW 0.*

0.0 0

0.0 0

0.0 2

0.1 MEAN WIND SPEED:

9.9 MISSING

0 0

0.0 0

0.0 1

o. 1 0

0.0 0

o.o 0

o.o 0

o.o 3

0.2 1

o. 1 5

0.3 8

0.4 o.,

0 0.0 0

o.o 0

o.o 0

0.0 19 1.0 0

0.0 0

o.o 2

o. 1 0

o.o 0

0.0 0

0.0 0.1 1

o. 1 0

0.0 1

0.1 8

0.4 0.1 2

0.1 2

0.1 o.,

0 0.0 19 1.0 Table 5 Page 1 of 9 0

0.0 0

0.0 0.1 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

o.o 0

0.0 0.1 o.,

0 o.o 2

0.1 3

0.2 0

0.0 0.4 LAPSE RATE:

LE -1.9 DEG C/100M CLASS A 18.6-24.5 GE 24.6 SUM PERCENT sut PERCENT SUM PERCENT 0

o.o 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 1

0. 1 0

0.0 5

0.3 0

0.0 0

0.0 0

0.0 0

o.o 0

o.o 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 1

o. 1 0

0.0 0

o.o 4

0.2 0

0.0 0

o.o

0. 1 0

o.o 0

o.o 6

0.3 0

0.0 0

0.0 17 0.9 0

0.0 0

o.o 5

0.3 o.,

0 o.o 3

0.2 2

0.1 0

0.0 6

0.3 1

0.1 0

o.o 5

0.3 0

0.0 0

0.0 0

0.0 5

0.3 0

0.0 53 2.7 I !

ARTIFICIAL ISLAND 7/90

  • 9/90 0.0-0.5 DIRECTION SUM PERCENT N

0 o.o NNE 0

o.o NE 0

0.0 ENE 0

o.o E

0 0.0 ESE 0

o.o SE 0

0.0 SSE 0

o.o s

0 0.0 SSY 0

0.0 SY 0

0.0 YSY 0

0.0 0

0.0 WY 0

o.o NW 0

o.o NIN 0

o.o 0

o.o MEAN WIND SPEED:

9.2 MISSING

4 0.6-3.5 SUM PERCENT 4

0.2 1

0. 1 0

0.0 0

0.0 1

o. 1 0

o.o 0

0.0 0

o.o 2

0.1 0

0.0 1

o. 1 0

o.o 2

0.1 0

o.o 0

o.o 0

0.0 11 0.6 JOINT DISTRIBUTION OF YIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS YIND: 300 FT DELTA T: (300*33FT)

YIND SPEED GRCXJPS (MPH) 3.6-7.5 7.6-12.5 12.6-18.5 SUM PERCENT SUM PERCENT SUM PERCENT 3

0.2 4

0.2 2

0.1 0

o.o 0

o.o 0

o.o 0

0.0 5

0.3 4

0.2 4

0.2 6

0.3 7

0.4 4

0.2 2

o. 1 4

0.2 5

0.3 50 2.5 5

0.3 7

0.4 1

0.1 2

0.1 1

o. 1 1
o. 1 3

0.2 4

0.2 1

0.1 3

0.2 6

0.3 4

0.2 1

o. 1 1

0.1 3

0.2 5

0.3 48 2.4 Table 5 Page 2 of 9 3

0.2 2

0.1 0

0.0 0

o.o 0

0.0 1

o. 1 2

0.1 0

0.0 1

o. 1 0

0.0 0

0.0 2

0.1 5

0.3 0

o.o 2

0.1 3

0.2 21 1.1 LAPSE RATE: *1.8 TO *1.7 DEG C/10<lt CLASS I 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 0

o.o 0

o.o 15 0.8 0

o.o 0

o.o 14 0.7 1

o. 1 0

o.o 4

0.2 0

0.0 0

o.o 2

0. 1 0

0.0 0

0.0 2

0. 1 0

o.o 0

o.o 2

o. 1 0

0.0 0

0.0 5

0.3 0

0.0 0

o.o 9

0.5 0

o.o 0

0.0 8

0.4 0

o.o 0

o.o 7

0.4 0

0.0 0

o.o 13 0.7 0

o.o 0

o.o 13 0.7 3

0.2 0

0.0 15 0.8 5

0.3 0

o.o 8

0.4 0

0.0 0

o.o 9

0.5 0

0.0 0

0.0 13 0.7 9

0.5 0

0.0 139 7.0

ARTIFICIAL ISLAND 7/90 - 9/90 0.0-0.5 0.6-3.5 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

WIND SPEED GR<lJPS (MPH) 3.6-7.5 7.6-12.5 12.6-18.5 DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

0 o.o 1

o. 1 NNE 0

o.o 1

0.1 NE 0

0.0 0

o.o ENE 0

o.o 0

0.0 E

0 0.0 0

0.0 tsE 0

o.o 0

0.0 SE 0

0.0 1

0.1 SSE 0

0.0 1

0.1 s

0 o.o 0

o.o SSW 0

0.0 1

0.1 SW 0

o.o 1

0. 1 WSW 0

0.0 3

0.2 w

0 0.0 1

o. 1 0

o.o 0

0.0 NW 0

0.0 3

0.2 NNW 0

o.o 1

0.1 0

0.0 14 0.7 MEAN WIND SPEED:

10.4 MISSING:

15 3

0.2 5

0.3 1

0. 1 0

0.0 0

0.0 0

0.0 1

0.1 3

o.z 2

0.1 1

o. 1 IS 0.4 5

0.3 7

0.4 6

0.3 4

0.2 6

0.3 52 2.6 9

0.5 7

0.4 0

o.o 2

0.1 0

0.0 0

0.0 0

0.0 6

0.3 1

0.1 3

0.2 4

0.2 9

0.5 2

o. 1 2
o. 1 1
o. 1 13 0.7 59 3.0 Table 5 Page 3 of 9 4

0.2 9

0.5 5

0.3 1

0.1 0

0.0 1

0.1 2

0.1 1

o. 1 2
o. 1 0

0.0 5

0.3 5

0.3 7

0.4 0

o.o 4

0.2 9

0.5

55.

2.8 LAPSE RATE: -1.6 TO -1.5 DEG C/100M CLASS C 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 1

o. 1 0

0.0 18 0.9 0

0.0 0

0.0 22 1.1 0

o.o 0

o.o 6

0.3 0

0.0 0

0.0 3

0.2 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.1 0

0.0 2

o. 1 6

0.3 1

0.1 0

0.0 12 0.6 0

0.0 0

0.0 5

0.3 0

0.0 0

0.0 5

0.3 0

o.o 2

o. 1 20 1.0 0

0.0 0

0.0 22 1.1 1

0.1 0

o.o 18 0.9 0

0.0 0

0.0 8

0.4 4

0.2 0

o.o 16 O.IS 1

0.1 0

o.o 30 1.5 8

0.4 4

0.2 192 9.7

ARTIFICIAL ISLAND 7/90

  • 9/90 0.0-0.5 0.6-3.5 DIRECTION SlJll PERCENT SlJll PERCENT N

0 o.o 1

0.1 NNE 0

o.o 2

0.1 NE 0

0.0 3

0.2 ENE 0

0.0 2

0. 1 E

0 0.0 0

0.0 ESE 0

0.0 2

0.1 SE 0

o.o 3

0.2 SSE 0

0.0 7

0.4 s

0 o.o 5

0.3 SS\\I 0

0.0 2

o. 1 SY 0

0.0 8

0.4 YS\\I 0

0.0 7

0.4 y

0 0.0 3

0.2 llN\\I 0

o.o 4

0.2 NY 0

0.0 3

0.2 NN\\I

  • o 0.0 4

0.2 0

0.0 56 2.8 MEAN YIND SPEED:

12.1 MISSING:

124 JOINT DISTRIBUTIOH OF YIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS YIND: 300 FT DELTA T: (300*33FT)

YIND SPEED GROUPS (MPH) 3.6-7.5 SlJll PERCENT 7

0.4 10 0.5 6

0.3 2

o. 1 3

0.2 1

o. 1 3

0.2 17 0.9 9

0.5 10 0.5 10 0.5 9

0.5 13 0.7 8

0.4 5

0.3 14 0.7 127 6.4 7.6-12.5 SUM PERCENT 16 0.8 10 0.5 20 1.0 8

0.4 3

0.2 0

o.o 7

0.4 28 1.4 29 1.5 26 1.3 15 0.8 17 0.9 9

0.5 3

0.2 10 0.5 17 0.9 218 11.0 Table 5 Page 4 of 9 12.6-18.5 SlJll PERCENT 8

0.4 37 1.9 19 1.o 12 0.6 0

o.o 3

0.2 5

0.3 58 2.9 23 1.2 13 0.7 28 1.4 15 0.8 20 1.0 9

0.5 7

0.4 13 0.7 270 13.7 LAPSE RATE: *1.4 TO *0.5 DEG C/100M CLASS D 18.6-24.5 GE 24.6 SUM PERCENT SlJll PERCENT SlJll PERCENT 4

0.2 0

0.0 36 1.8 10 0.5 0

0.0 69 3.5 10 0.5 1

0. 1 59 3.0 5

0.3 0

0.0 29 1.5 0

0.0 0

0.0 6

0.3 0

0.0 0

0.0 6

0.3 4

0.2 9

0.5 31 1.6 12 0.6 2

0.1 124 6.3 7

0.4 0

0.0 73 3.7 8

0.4 0

0.0 59 3.0 4

0.2 3

0.2 68 3.4 0

0.0 0

0.0 48 2.4 9

0.5 0

0.0 54 2.7 3

0.2 0

0.0 27 1.4 3

0.2 0

0.0 28 1.4 3

0.2 2

0. 1 53 2.7 82 4.1 17 0.9 770 38.9

ARTIFICIAL ISLAND 7/90 - 9/90 0.0-0.5 0.6-3.5 JOINT DISTRIBUTION Of WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T:

(300~33FT)

WIND SPEED GR<XJPS (MPH) 3.6-7.5 7.6-12.5 12.6-18.5 DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT Slit PERCENT N

0 o.o NNE 0

0.0 NE 0

o.o ENE 0

0.0 E

0 o.o ESE 0

0.0 SE 0

0.0 SSE 0

o.o s

0 0.0 ssv 0

0.0 SW 0

0.0 WSW 0

0.0 w

0 0.0 WY 0

0.0 NW 0

0.0 NNW

0.

0.0 0

0.0 MEAN WIND SPEED:

12.0 MISSING:

66 0

o.o 9

2 0.1 5

1 0.1 4

0 o.o 2

0 0.0 3

0 0.0 6

0 0.0 1

1 0.1 11 3

0.2 8

3 0.2 9

4 0.2 1

3 0.2 11 6

0.3 20 6

0.3 1

3 0.2 11 1

0.1 10 33

1. 7 124 0.5 7

0.4 11 0.3 11 0.6 18 0.2 15 0.8 13 0.1 20 1.0 8

0.2 5

0.3 4

0.3 6

0.3 5

0.1 6

0.3 5

0.6 15 0.8 6

0.4 15 0.8 21 0.5 11 0.6 34 0.4 24 1.2 35 0.6 10 0.5 17 1.0 21 1.1 14 0.4 13 0.1 21 0.6 17 0.9 27 0.5 12 0.6 17 6.3 208 10.5 256 Table 5 Page 5 of 9 0.6 0.9 0.1 0.4 0.2 0.3 0.3 0.3 1.1 1.7 1.8 0.9 0.1 1.1 1.4 0.9 12.9 LAPSE RATE: -0.4 TO 1.5 DEG C/100M CLASS E 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 11 0.6 0

o.o 38 1.9 1

o. 1 0

0.0 37 1.9 1

o. 1 0

o.o 34 1.7 0

0.0 0

0.0 30 1.5 0

0.0 0

0.0 12 0.6 0

0.0 0

0.0 17 0.9 1

0.1 0

0.0 13 0.7 0

0.0 0

0.0

))

1.7 3

0.2 0

0.0 50 2.5 12 0.6 1

0. 1 70 3.5 10 0.5 0

0.0 80 4.0 4

0.2 0

0.0 45 2.3 1

0.1 0

o.o 62 3.,

3 0.2 1

0. 1 51 2.6 11 0.6 1

0.1 70 3.5 16 0.8 1

0.1 57 2.9 74 3.7 4

0.2 699

]5.4

ARTIFICIAL ISLAND 7/90 - 9/90 0.0-0.5 DIRECTIOll SUM PERCENT N

0 0.0 NNE 0

o.o NE 0

0.0 ENE 0

0.0 E

0 0.0 ESE 0

o.o SE D

0.0 SSE 0

o.o s

0 0.0 SSW 0

0.0 SY 0

0.0

\\ISW 0

0.0

0.

o.o 0

o.o NW 0

o.o NNll 0

0.0 0

0.0 MEAN lllND SPEED:

13.5 MISSING:

6 0.6-3.5 SUM PERCENT 0

0.0 0

o.o 0

o.o 0

0.0 0

0.0 1

0.1 0

0.0 0

o.o 2

0.1 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

0;0 3

0.2 JOINT DISTRIBUTION OF lllND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS

\\llND: 3DO FT DELTA T: (300-33FT) lllND SPEED GROUPS (MPH) 3.6-7.5 Slit PERCENT 2

0.1 0

o.o 0

o.o 0

0.0 1

0.1 0

0.0 0

0.0 0

o.o 0

0.0 0

o.o 0

0.0 0

o.o 0

0.0 2

0.1 2

0.1 2

0.1 9

0.5 7.6-12.5 SUM PERCENT 8

0.4 4

0.2 0

0.0 2

0.1 0

o.o 0

0.0 3

0.2 0.1 1

0.1 0

0.0 3

0.2 0

0.0 1

0.1 3

0.2 3

0.2 6

0.3 35 1.8 Table 5 Page 6 of 9 12.6-18.5 SUM PERCENT 21 1.1 4

0.2 3

0.2 e

0.4 0

o.o 0

0.0 0

0.0 0

o.o 0.1 4

0.2 3

0.2 6

0.3 1

0.1 0

0.0 5

0.3 8

0.4 64.

3.2 LAPSE RATE:

1.6 TO 4.0 DEG C/100M CLASS F 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 6

0.3 0

0.0 37 1.9 0

0.0 0

0.0 e

0.4 0

o.o 0

0.0 3

0.2 0

0.0 0

0.0 10 0.5 0

0.0 0

o.o 0.1 0

0.0 0

0.0 0.1 0

o.o 0

o.o 3

0.2 0

0.0 0

0.0 1

0.1 1

0.1 0

0.0 5

0.3 1

0.1 0

0.0 5

0.3 1

0.1 0

0.0 7

0.4 0

0.0 0

o.o 6

0.3 0.1 0

0.0 3

0.2 0

0.0 0

0.0 5

0.3 1

0.1 0

0.0 11 0.6 2

0.1 0

0.0 18 0.9 13 0.1 0

0.0 124 6.3

\\*

ARTIFICIAL ISLAND 7/90

  • 9/90 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED 0.0*0.5 DIRECTION Slit PERCENT II 0

0.0 NNE 0

0.0 NE 0

0.0 ENE 0

0.0 E

0 0.0 ESE 0

o.o SE 0

0.0 SSE 0

0.0 s

0 0.0 SSW 0

0.0 SW 0

0.0 WSW 0

o.o w

0 0.0

\\INW 0

0.0 NW 0

0.0 NNW 0

0.0 0

0.0 MEAN WIND SPEED:

0.0 MISSING

0 0.6*3.5 Slit PERCENT 0

o.o 0.0 0.0 0.0 0.0 o.o 0.0 0.0 0.0 0.0 o.o 0.0 0.0 0

o.o 0

o.o 0

0.0 0

0.0 BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300*33FT)

WIND SPEED GROUPS (MPH)

J.6-7.5 Slit PERCENT 0

o.o 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 7.6-12.5 Slit PERCENT 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

o.o 0

0.0 Table 5 Page 7 of 9 12.6-18.5 S\\lt PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

o.o 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 I

I I

I LAPSE RATE:

GT 4.0 DEG C/100M I

CLASS G I

18.6-24.5 GE 24.6 S\\M PERCENT S\\lt PERCENT Slit PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

o.o 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0

ARTIFICIAL ISLAND 7/90 - 9/90 JOINT DISTRIBUTION OF WIND.DIRECTIOM AND SPEED BY ATMOSPHERIC STABILITY CLASS 0.0-0.5 DIRECTION SUM PERCENT N

0 o.o NNE 0

0.0 NE 0

0.0 ENE 0

0.0 E

0 0.0 ESE 0

0.0 SE 0

o.o SSE 0

0.0 s

0 0.0 SSW 0

0.0 SW 0

o.o WSW 0

0.0 w

0 0.0 WNW 0

0.0 IN 0

o.o NIN 0

o.o 0

0.0 MEAN WI ND SPEED:

11. 7 WIND: 300 FT DELTA T: (300-33FT)

WIND SPEED GROUPS (MPH) 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT 6

0.3 24 1.2 45 2.3 47 2.4 6

0.3 24 1.2 39 2.0 70 3.5

  • 4 0.2 14 0.7 38 1.9 41 2.1 2

0.1 4

0.2 34

1. 7 29 1.5 1

0.1 1

0.4 9

0.5 4

0.2 3

0.2 1

0.4 7

0.4 10 0.5 4

0.2 5

0.3 20 1.0 14 0.1 9

0.5 39 2.0 55 2.8 65 3.3 12 0.6 24 1.2 47 2.4 48 2.4 6

0.3 29 1.5 44 2.2 51 2.6 14 0.7 39 2.0 60 3.0 72 3.6 15 0.8 33 1.7 41 2.1 46 2.3 12 0.6 44 2.2 36 1.8 47 2.4 10 0.5 25 1.3 24 1.2 32 1.6 9

0.5 26 1.3 35 1.8 48 2.4 6

0.3 37 1.9 53 2.7 50 2.5 119 6.0 381 19.3 587 29.7 674 34.1 Table 5 Page 8 of 9 ALL STABILITY CLASSES 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 22 1.1 0

o.o 144 7.3 11 0.6 0

0.0 150 7.6 13 0.7 1

0.1 111 5.6 5

0.3 0

0.0 74 3.7 0

o.o 0

o.o 21 1.1 0

0.0 0

0.0 27 1.4 5

0.3 11 0.6 59 3.0 13 0.7 2

0.1 183 9.3 11 0.6 0

0.0 142 7.2 21 1.1 1

0.1 152 7.7 15 0.8 5

0.3 205 10.4 4

0.2 0

0.0 139 7.0 16 0.8 0

o.o 155 7.8 13 0.7 1

0.1 105 5.3 20 1.0 1

0.1 139 7.0 22 1.1 3

0.2 171 8.6 191 9.7 25 1.3 1977 100.0 MISSING HOURS:

231

IFICIAL ISLAND 7/90 - 9/90 0.0-0.5 0.6-3.5 DIRECTION SUM PERCENT SUM PERCENT II 0

o.o 7

0.4 NNE 0

0.0 6

0.3 NE 0

0.0 4

0.2 ENE 0

o.o 2

0.1 E

0 0.0 1

0.1 ESE 0

o.o 3

0.2 SE 0

0.0 4

0.2 SSE 0

0.0 9

0.5 s

0 o.o 12 0.6 ssw*

0 o.o 6

0.3 SW 0

0.0 14 0.7 WSW 0

o.o 15 0.8 w

0 0.0 12 0.6 WN" 0

0.0 10 0.5 NW 0

o.o 10 0.5 NNW 0

0.0 6

0.3 0

o.o 121 6.1 MEAN WIND SPEED:

11.7 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300*33FT)

WIND SPEED GROUPS (MPH) 3.6-7.5 7.6-12.5 12.6-18.5 SUM PERCENT SUM PERCENT SUM PERCENT 27 1.4 46 2.3 47 2.4 25 1.3 39 2.0 70 3.5 14 0.7 38 1.9 41 2.1 4

0.2 34 1.7 29 1.5 7

0.4 9

0.5 4

0.2 7

0.4 7

0.4 10 0.5 5

0.3 20 1.o 14 0.7 39 2.0 57 2.9 68 3.4 24 1.2 47 2.4 48 2.4 29 1.5 44 2.2 51 2.6 39 2.0 62 3.1 72 3.6 33

1. 7 41
2. 1 46 2.3 44 2.2 36 1.8 47 2.4 25 1.3 24 1.2 32 1.6 26 1.3 35 1.8 48 2.4 39 2.0 53 2.7 50 2.5 387 19.4 592 29.7 677 34.0 Table 5 Page 9 of 9 DIRECTION VS SPEED ONLY 18.6-24.5 GE 24.6 Slit PERCENT SUM PERCENT SUM PERCENT 22 1.1 0

0.0 149 7.5 11 0.6 0

0.0 151 7.6 13 0.7 1

0.1 111 5.6 5

0.3 0

0.0 74 3.7 0

0.0 0

0.0 21 1.1 0

0.0 0

o.o 27 1.4 5

0.3 0.6 59 3.0 13 0.7 2

0.1 188 9.4 0.6 0

0.0 142 7.1 21 1.1 1

0.1 152 7.6 15 0.8 5

0.3 207 10.4 4

0.2 0

0.0 139 7.0 16 0.8 0

0.0 155 7.8 13 0.7 1

o. 1 105 5.3 20 1.0 1

0.1 140 7.0 22 1.1 3

0.2 173 8.7 191 9.6 25 1.3 1993 100.0 MISSING HOURS:

215

ARTIFICIAL ISLAND 10/90-12/90 0.0-0.5 0.6-3.5 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: <300*33FT)

WIND SPEED GROUPS (MPH) 3.6-7.5 7.6-12.5 12 *. 6-18.5 DIRECTION SIM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT II 0

0.0 0

o.o 0

NNE 0

o.o 0

0.0 0

llE 0

0.0 0.0 0

ENE 0

o.o 0.0 0

E 0

0.0 0.0 0

ESE 0

o.o o.o 0

SE 0

0.0 0.0 0

SSE 0

o.o o.o 0

s 0

0.0 0.0 0

SSW 0

0.0 0.0 0

SW 0

o.o 0.0 0

WSW 0

0.0 0.0 1

w 0

0.0 0.0 1

WW 0

0.0 0.0 0

w 0

0.0 0.0 0

NW 0

o.o 0.0 0

0 0.0 0

0.0 2

MEAN WIND SPEED:

15.0 MISSING:

0 o.o 0

o.o o.o 0

o.o o.o 0

o.o o.o 0

0.0 0.0 0

o.o 0.0 0

0.0 0.0 1

o.o 0.0 1

o.o 0.0 0

o.o 0.0 0

0.0 o.o 4

0.2 o.o 0

0.0 o.o 3

0.1 0.0 2

0.1 0.0 0

0.0 o.o 0

0.0

0. 1 11 0.5 1

o.o 0

0.0 0

0.0 0

o.o 0

0.0 0

0.0 1

o.o 0

o.o 1

o.o 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

o.o 4

0.2 Table 6 Page 1 of 9 LAPSE RATE:

LE -1.9 DEG C/100M CLASS A 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 1

0.0 0

o.o 2

0.1 0

o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o 0

o.o 0

0.0 0

0.0 0

o.o 0

0.0 0

o.o 0

0.0 2

o. 1 0

o.o 0

0.0 1

0.0 0

o.o 0

0.0 1

0.0 0

o.o 0

o.o 0

0.0 0

o.o 0

o.o 4

0.2 0

o.o 0

0.0 1

o.o 0

o.o 0

o.o 5

0.2 4

0.2 0

o.o 6

0.3 1

o.o 0

0.0 1

0.0 2

0.1 2

0.1 4

0.2 8

0.4 2

0.1 27 1.2

ARTfFICIAL ISLAND 10/90-12/90 0.0-0.5

.0.6-3.5 DIRECTIOM S~ PERCENT SUM PERCENT N

0 0.0 0

0.0 NNE 0

0.0 0

o.o NE 0

o.o 0

0.0 ENE 0

0.0 0

0.0 E

0 0.0 0

0.0 ESE 0

0.0 0

0.0 SE 0

0.0 0

0.0 SSE 0

o.o 0

o.o s

0 o.o 0

0.0 SSY 0

0.0 0

0.0 SY 0

0.0 0

o.o YSY 0

0.0 1

0.0 y

0 o.o 0

0.0 YNY 0

0.0 0

0.0 NY 0

0.0 0

0.0 NNY 0

0.0 0

0.0 JOINT DISTRIBUTIOM OF YIND DIRECTIOM AND SPEED BY ATMOSPHERIC STABILITY CLASS YIND: 300 FT DELTA T: (300-33FT)

YIND SPEED GROUPS (MPH) 3.6-7.5 7.6-12.5 12.6-18-5 SUM PERCENT SUM PERCENT SUM PERCENT 0

0.0 4

0.2 0

0.0 0

0.0 0

0.0 1

o.o 0

0.0 0

0.0 0

0.0 0

o.o 1

0.0 0

0.0 0

o.o 1

0.0 0

o.o 0

o.o 0

o.o 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 2

o. 1 0

0.0 1

0.0 0

0.0 1

0.0 0

o.o 0

0.0 1

0.0 0

o.o 0

0.0 0

o.o 0

0.0 0

0.0 0

0.0 1

0.0 2

0.1 0

0.0 0

0.0 1

o.o 3

o. 1 0

0.0 3

0.1 6

0.3 0

0.0 3

0.1 5

0.2 0

o.o o.o 3

0.1 18 0.8 17 0.8 MEAN MINO SPEED:

17.5 MISSING:

0 Table 6 Page 2 of 9 LAPSE RATE: -1.8 TO -1.7 DEG C/100M CLASS I 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 2

0.1 0

0.0 6

0.3 0

o.o 0

0.0 1

0.0 0

o.o 0

o.o 0

0.0 0

0.0 0

0.0 1

o.o 0

0.0 0

o.o 1

0.0 0

o.o 0

0.0 0

0.0 0

o.o 0

o.o 2

0.1 0

0.0 0

o.o 2

0. 1 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 1

0.0 0

o.o 0

0.0 0

0.0 0

o.o 0

o.o 1

0.0 1

0.0 1

0.0 5

0.2 4

0.2 1

0.0 9

0.4 8

0.4 11 0.5 28 1.3 5

0.2 4

0.2 17 0.8 20 0.9 17 0.8 76 3.5

ARTIFICIAL ISLAND 10/90-12/90 0.0-0.5 0.6-3.5 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

WIND SPEED GR<llPS (MPH) 3.6-7.5 7.6-12.5 12.6-18.5 DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

0 o.o MME 0

o.o NE 0

0.0 ENE 0

o.o E

0 0.0 ESE 0

0.0.

SE 0

0.0 SSE 0

0.0 s

0 0.0 SS\\I 0

0.0 SW 0

0.0 WSY 0

0.0 w

0

. 0.0 WNW 0

o.o 0

0.0 NNW 0

0.0 0

0.0 MEAN WIND SPEED:

14.6 MISSING:

0 0

0.0 2

0 0.0 0

1 0.0 0

0 0.0 0

0 0.0 2

0 0.0 0

0 0.0 0

0 o.o 2

0 0.0 1

0 0.0 1

0 0.0 2

1 0.0 2

0 0.0 1

0 o.o 3

0 o.o

]

0 0.0 2

2 0.1 21 0.1 5

o.o 3

0.0 0

o.o 1

0.1 0

0.0 1

o.o 2

o.'

1 0.0 0

0.0 0

o.'

1 0.1 1

o.o 4

o.'

2 o.'

3 o.'

6 1.0 30 0.2 2

0.1 1

0.0 0

o.o 0

0.0 0

0.0 0

0.'

1 0.0 o.o 0

0.0 1

o.o 0

0.0 1

0.2 o.,

3 o.,

8 0.3 3

1.4 22 Table 6 Page 3 of 9 0.1 0.0 0.0 o.o o.o 0.0 0.0 o.o o.o 0.0 0.0 0.0 0.0 0.1 0.4 0.'

1.0 LAPSE RATE: -1.6 TO -1.5 DEG C/100M CLASS C 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 2

0.1 1

0.0 12 0.5 0

0.0 0

0.0 4

0.2 0

o.o 0

0.0 1

0.0 0

0.0 0

o.o 1

0.0 0

0.0 0

o.o 2

0.1 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 3

o.'

0 0.0 0

0.0 4

0.2 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 2

0.'

0 0.0 0

0.0 3

0.1 2

0.1 0

o.o 7

0.3 2

o.,

0.0 9

0.4 3

0.1 5

0.2 16 0.7 6

0.3 9

0.4 29 1.3 2

0.'

1 0.0 14 0.6 17 O.B 17 O.B 109 5.0

ARTIFICIAL ISLAND 10/90*12/90 0.0*0.5 0.6-3.5 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300*33FT)

WIND SPEED GROUPS (MPH) 3.6*7.5 7.6*12.5 12.6*18.5 DIRECTION SUM PERCENT Slit PERCENT Slit PERCENT Slit PERCENT S\\Jf PERCENT N

0 0.0 NNE 0

0.0 NE 0

o.o ENE 0

0.0 E

0 o.o ESE 0

0.0 SE 0

o.o SSE 0

0.0 s

0 0.0 SSW 0

o.o SW 0

o.o WSW 0

0.0 w

0 0;0 0

0.0 NW 0

0.0 NNW 0

0.0 0

0.0 MEAN WIND SPEED:

16.0 MISSING:

0 2

o.,

0 0.0 0

o.o 0

0.0 0

o.o 1

o.o 1

o.o 2

o. 1 1

0.0 3

0.1 4

0.2 1

o.o 1

o.o 3

0.1 2

0.1 1

0.0 22 1.0 3

0.1 6

15 0.7 5

6 0.3 8

1 0.0 2

2 0.1 0

2 0.1 2

2 0.1 6

3 0.1 5

2 0.1 8

3 0.1 8

6 0.3 15 9

0.4 5

2 0.1 6

5 0.2 1

4 0.2 4

6 0.3 11 71 3.2 92 0.3 7

0.2 3

0.4 12 0.1 2

0.0 1

0.1 1

0.3 8

0.2 10 0.4 9

0.4 10 0.7 4

0.2 1

0.3 8

0.0 13 0.2 11 0.5 15 4.2 115 Table 6 Page 4 of 9 0.3 0.1 0.5

o. 1 0.0 0.0 0.4 0.5 0.4 0.5 0.2 0.0 0.4 0.6 0.5 0.7 5.2 LAPSE RATE: *1.4 TO *0.5 DEG C/100M CLASS D 18.6*24.5 GE 24.6 S\\Jf PERCENT Slit PERCENT Slit PERCENT 3

0.1 13 0.6 34 1.5 0

0.0 0

0.0 23 1.0 2

0.1 0

0.0 28 1.3 3

0.1 0

0.0 8

0.4 0

0.0 0

o.o 3

0.1 0

0.0 0

0.0 6

0.3 2

o.,

6 0.3 25 1.1 5

0.2 0

o.o 25 1.1 22

,.0 4

0.2 46

2. 1 4

0.2 4

0.2 32 1.5 1

0.0 0

0.0 30 1.4 2

0.1 1

o.o 19 0.9 13 0.6 2

0.1 32 1.5 11 0.5 16 0.7 49 2.2 41 1.9 22 1.0 84 3.8 14 0.6 5

0.2 52 2.4 123 5.6 73 3.3 496 22.6

ARTIFICIAL ISLAND 10/90-12/90 0.0-0.5 0.6-3.5 JOINT DISTRIBUTION OF WINO DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WINO: 300 FT DELTA T: (300-33FT)

WINO SPEED GRClJPS (MPH) 3.6-7.5 7.6-12.5 12.6-18.5 DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT II 0

0.0 llNE 0

o.o llE 0

0.0 ENE 0

0.0 E

0 0.0 ESE 0

0.0 SE 0

0.0 SSE 0

0.0 s

0 o.o SSW 0

0.0 SW 0

o.o "5W 0

0.0 w

0 0.0 UNW 0

0.0 NW 0

0.0 NNW 0

0.0 0

0.0 MEAN WIND SPEED:

16~ 1 MISSING:

0 3

0.1 0

4 0.2 10 1

0.0 1

1 0.0 l

1 0.0 4

1 0.0 3

1 0.0 8

2 0.1 9

2 0.1 11 2

0.1 9

2 0.1 9

0 0.0 7

3 0.1 7

2 0.1 4

0 0.0 1

3 0.1 2

28 1.3 88 0.0 0.5 0.0 0.1 0.2 0.1 0.4 0.4 0.5 0.4 0.4 0.3 0.3 0.2 0.0 0.1 4.0 9

0.4 12 5

0.2 9

8 0.4 7

6 0.3 1

9 0.4 4

5 0.2 3

17 0.8 17 9

0.4 20 10 0.5 15 31 1.4 37 22 1.0 31 20 0.9 24 15 0.7 13 1

0.3 23 10 0.5 42 19 0.9 49 202 9.2 307 Table 6 Page 5 of 9 0.5 0.4 0.3 0.0 0.2 0.1 0.8 0.9 0.7 1.7 1.4 1.1 0.6 1.0 1.9 2.2 14.0 LAPSE RATE: *0.4 TO 1.5 DEG C/100M CLASS E 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 26 1.2 10 0.5 60 2.7 2

0.1 0

0.0 30 1.4 3

0.1 0

0.0 20 0.9 1

0.0 0

o.o 12 0.5 1

0.0 0

0.0 19 0.9 1

0.3 1

0.0 20 0.9 20 0.9 21 1.0 B4 3.8 11 0.5 12 0.5 63 2.9 11 0.5 4

0.2 53 2.4 19 0.9 6

0.3 104 4.7 22 1.0 9

0.4 95 4.3 16 0.7 3

0.1 70 3.2 11 0.5 2

0.1 51 2.3 12 0.5 6

0.3 54 2.5 63 2.9 9

0.4 125 5.7 42 1.9 15 0.7 130 5.9 267 t2.2 98 4.5 990 45.1

ARTIFICIAL ISLAND 10/90-12/90 0.0-0.5 0.6-3.5 DIRECTION SUM PERCENT SUM PERCENT N

0 0.0 0

0.0 NNE 0

o.o 0

0.0 NE 0

0.0 0

o.o ENE 0

o.o 0

0.0 E

0 o.o 0

o.o ESE 0

o.o 1

0.0 SE 0

o.o 0

0.0 SSE 0

0.0 0

0.0 s

0 o.o 2

0.1 SSll 0

o.o 1

o.o Sii 0

0.0 1

o.o llSll 0

o.o 0

0.0 0

o.o 0

0.0 0

o.o 0

0.0 NII 0

0.0 2

0.1 NNll 0

0.0 0

0.0 0

o.o 7

0.3 MEAN MIND SPEED:

15.5 MISSING:

0 JOINT DISTRIBUTION OF MIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS MIND: 300 FT DELTA T: (300-33FT)

MIND SPEED GRClJPS (MPH) 3.6-7.5 SUM PERCENT 0

o.o 0

o.o 0

0.0 0

o.o 2

0.1 3

0.1 4

0.2 2

0.1 4

0.2 6

0.3 3

o. 1 6

0.3 4

0.2 2

o. 1 o.o 0

0.0 37

1. 7 7.6-12.5 12.6-18.5 SUM PERCENT SUM PERCENT 5

0.2 8

0.4 5

0.2 17 0.8 6

0.3 2

0.1 3

o. 1 0

0.0 8

0.4 2

0.1 3

0.1 5

0.2 13 0.6 4

0.2 5

0.2 3

0.1 4

0.2 5

0.2 6

0.3 24 1.1 10 0.5 19 0.9 8

0.4 18 o.e 9

0.4 9

0.4 1

0.0 2

0.1 2

0.1 9

0.4 8

0.4 16 0.7 96 4.4 143 6.5 Table 6 Page 6 of 9 LAPSE RATE:

1.6 TO 4.0 DEG C/100M CLASS F 18.6-24.5 GE 24.6 SUf PERCENT SUM PERCENT SUM PERCENT 1

0.0 0

0.0 14 0.6 0

0.0 0

o.o 22 1.0 2

0.1 0

o.o 10 0.5 0

0.0 0

o.o 3

0. 1 0

0.0 0

0.0 12 0.5 1

0.0 0

o.o 13 0.6 1

0.0 1

o.o 23 1.0 1

0.0 10 0.5 21 1.0 2

0.1 4

0.2 21 1.0 14 0.6 14 0.6 65

].0 21 1.0 12 0.5 66 3.0 12 0.5 1

o.o 45 2.1 6

0.3.

0 0.0 28 1.]

0 0.0 1

0.0 6

0.3 6

0.3 0

0.0 20 0.9 2

0.1 0

0.0 26 1.2 69

  • 1.1 43 2.0 395 18.0

ARTIFICIAL ISLAND 10/90-12/90 0.0-0.5 0.6-3.5 DIRECTION SUM PERCENT SUM PERCENT N

0 0.0 0

o.o NNE 0

0.0 0

0.0 NE 0

o.o 0

0.0 ENE 0

o.o 0

0.0 E

0 0.0 0

0.0 ESE 0

o.o 1

o.o SE 0

0.0 0

0.0 SSE 0

0.0 1

o.o s

0 0.0 1

o.o SSW 0

0.0 1

o.o SW 0

o.o 0

0.0 WSW 0

o.o 0

o.o 0

0.0 1

0.0 WNW 0

o.o 0

0.0 NW 0

o.o 0

o.o NNW 0

0.0 0

0.0 0

0.0 5

0.2 MEAN WIND SPEED:

13.9 MISSING:

0 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WINO: 300 FT DELTA T: (300-33FT)

WIND SPEED GRCIJPS CMPH) 3.6-7.5 SUM PERCENT 0

o.o 0

0.0 1

0.0 0

o.o 0

0.0 0

o.o 1

o.o 4

0.2 0

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

o.o 0

o.o 0

0.0 9

0.4 7.6-12.5 SUM PERCENT 1

0.0 2

0.1 0

0.0 1

0.0 1

o.o 0

0.0 0

o.o 1

0.0 3

0.1 7

0.3 5

0.2 1

0.0 4

0.2 0

0.0 1

0.0 0

0.0 27 1.2 Table 6 Page 7 of 9 12.6-18.5 SUM PERCENT 0

0.0 3

0.1 1

o.o 0

0.0 0

0.0 0

0.0 0

o.o 1

0.0 7

0.3 10 0.5 4

0.2 3

0.1 6

0.3 2

0.1 0

0.0 0

0.0 37

1. 7 LAPSE RATE:

GT 4.0 DEG C/100M CLASS G 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 0

o.o 0

o.o 1

0.0 0

o.o 0

0.0 5

0.2 0

o.o 0

0.0 2

0.1 0

0.0 0

0.0 1

0.0 0

0.0 0

o.o 1

o.o 0

0.0 0

0.0 1

o.o 0

0.0 0

0.0 1

0.0 0

0.0 1

0.0 8

0.4 7

0.3 2

0.1 20 0.9 3

0. 1 0

o.o 24 1.1 2

o. 1 0

0.0 11 0.5 0

0.0 0

o.o 4

0.2 6

0.3 1

0.0 18 0.8 1

o.o 0

o.o 3

0.1 0

o.o 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 19 0.9 4

0.2 101 4.6

ARTIFICIAL ISLAND 10/90-12/90 0.0-0.5 0.6-3.5 JOINT DISTRIBUTION OF VIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS VIND: 300 FT DELTA T: (300-33FT)

VINO SPEED GR<lJPS (MPH) 3.6-7.5 7.6-12.5 12.6-18.5 DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

0 0.0 5

0.2 5

0.2 30 1.4 30 1.4 NNE 0

0.0 4

0.2 25 1.1 20 0.9 34 1.5 NE 0

0.0 2

o. 1 8

0.4 22 1.0 22 1.0 ENE 0

0.0 1

0.0 4

0.2 14 0.6 3

0.1 E

0 0.0 1

0.0 10 0.5 19 0.9 7

0.3 ESE 0

0.0 4

0.2 8

0.4 11 0.5 9

0.4 SE 0

o.o 2

o. 1 16 0.7 40 1.8 31 1.4 SSE 0

0.0 5

0.2 20 0.9 24 1.1 35 1.6 s

0 0.0 6

0.3 19 0.9 25 1.1 38

,

  • 7 ssv 0

0.0 7

0.3 22 1.0 52 2.4 83 3.8 sv 0

0.0 7

0.3 20 0.9 57 2.6 58 2.6 vsv 0

0.0 3

0.1 25 1.1 35 1.6 47 2.1 v

0 0.0 5

0.2 16 0.7 43 2.0 38

1. 7 VNV 0

o.o 5

0.2 14 0.6 14 0.6 46

2. 1 NV 0

0.0 4

0.2 9

0.4 23 1.0 76 3.5 NNV 0

0.0 4

0.2 10 0.5 47

2. 1 88 4.0 ALL STABILITY CLASSES 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT 35 1.6 24 1.1 129 5.9 2
o. 1 0

o.o 85 3.9 7

0.3 0

0.0 61 2.8 4

0.2 0

0.0 26 1.2 1

o.o 0

o.o 38 1.7 a

0.4 1

0.0 41 1.9 23 1.o 28 1.3 140 6.4 17 o.a 23 1.0 124 5.7 42 1.9 14 0.6 144 6.6 40 1.8 24 1.1 228 10.4 46

2. 1 21 1.0 209 9.5 32 1.5 5

0.2 147 6.7 39 1.8 7

0.3 148 6.7 35 1.6 29 1.3 143 6.5 125 5.7 51 2.3 288 13.1 67 3.1 27 1.2 243 11.1 0

0.0 65 3.0 231 10.5 476 21.7 645 29.4 523 23.B 254 11.6 2194 100.0 MEAN VIND SPEED:

15.B Table 6 Page 8 of 9 MISSING Hll.IRS:

14

  • \\

TIFICIAL ISLAND 10/90*12/90 JOINT DISTRIBUTl<JI Of WIND CTION AND SPEED 0.0-0.5 0.6-3.5 DIRECTION SUM PERCENT SUM PERCENT N

0 0.0 5

0.2 NNE 0

o.o 4

0.2 NE 0

0.0 2

0.1 ENE 0

o.o 1

0.0 E

0 0.0 1

0.0 ESE 0

D.O 4

0.2 SE 0

0.0 2

0.1 SSE 0

0.0 5

0.2 s

0 O.D 6

D.3 SSW 0

0.0 1

0.3 SW 0

o.o 1

0.3 WSW 0

o.o 3

0.1 w

0 o.o 6

0.3 WNW 0

0.0 5

0.2 NW 0

0.0 4

0.2 NNW 0

0.0 4

0.2 0

0.0 66 3.0 MEAN WIND SPEED:

15.B BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300*33FT)

WIND SPEED GROUPS (MPH) 3.6*7.5 7.6*12.5 12.6*18.5 SUM PERCENT SUM PERCENT SUM PERCENT 5

0.2 30 1.4 30 1.4 25 1.1 20 0.9 34 1.5 8

0.4 22 1.0 22 1.0 4

0.2 14 0.6 3

0.1 10 0.5 19 0.9 1

0.3 a

0.4 11 0.5 9

0.4 16 0.7 40 1.8 31 1.4 20 0.9 24 1.1 35 1.6 19 0.9 25 1.1 38

1. 7 22 1.D 52 2.4 83 3.8 20 0.9 57 2.6 58 2.6 25 1.1 35 1.6 49 2.2 16 0.7 44 2.0 44 2.0 14 D.6 14 0.6 48 2.2 9

0.4 23 1.0 16 3.4 10 0.5 47 2.1 88 4.0 18.6*24.5 SUM PERCENT 35 1.6 2

0.1 1

0.3 4

0.2 1

o.o 8

0.4 23 1.0 17 0.8 42 1.9 40 1.8 46 2.1 33 1.5 39 1.8 35 1.6 125 5.7 61 3.0 231 10.5 4n 21.6 655 29.7 524 23.7 Table 6 Page 9 of 9 DIRECTION VS SPEED ONLY GE 24.6 SUM PERCENT SUM PERCENT 24 1.1 129 5.8 0

0.0 85 3.9 0

o.o 61 2.8 0

0.0 26 1.2 0

0.0 38 1.7 1

0.0 41 1.9 28 1.3 140 6.3 23 1.0 124 5.6 14 0.6 144 6.5 24 1.1 228 10.3 21 1.0 209 9.5 5

0.2 150 6.8 1

0.3 156 7.1 29 1.3 145 6.6 51 2.3 288 13.0 27 1.2 243 11.0 254 11.5 2207 100.0 MISSING HOURS:

(

AMMENDMENT TO RERR 28 Page 30

f Liauid Pathways Doses to individuals in the population from liquid releases are primarily from the seafood ingestion pathway.

The total body dose to an individual was calculated to be 3.04E-Ol mrem.

The calculated highest organ dose from liquid releases was 1.13E+OO mrem to the GI-LLI. The calculated population total body dose was 9.SOE-02 person-rem.

The calculated average total body dose to the population within fifty miles of the site was 1.64E-05 mrem/person.

. Air Pathway The resulting total body and skin doses to an individual were calculated to be 3.04E-03 mrem and 7.41E-03 mrem respectively.

The calculated highest organ dose due to radioiodines and particulates with a greater than eight day half-life was 1.13E-02 mrem to the thyroid.

The calculated population total body dose was 4.05E-Ol person-rem.

The calculated average total body dose to the population within fifty miles of the site was 6.78E-05 mrem/person.

Direct Radiation Direct radiation may be estimated by Thermoluminescent dosimetric (TLD) measurements.

One method for comparing TLD measurements is by omparison with preoperational data.

It should be noted that the TLDs easure direct radiation from both the Salem and Hope Creek Generating Stations at Artificial Island.

TLDs at onsite locations 2S-2 and 5S-1, which are 0.3 miles and 0.9 miles from the point of origin, averaged 4.6 and 4.1 mrads/month respectively. The values for stations 2s-2 and 5S-l are within the statistical variation associated with the preoperational program results.

It should be noted that the nearest resident is 3.5 miles away. It can be concluded that there is no measurable dose to any.offsite location from direct radiation.

Page 31