ML18095A290

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 900501-04.Violations Noted: Failure to Ensure That All Personnel Working Under Rev 2 of Radiation Work Permit (RWP) P901S00383 Had Read & Signed RWP Compliance Agreement
ML18095A290
Person / Time
Site: Salem  PSEG icon.png
Issue date: 06/11/1990
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML18095A289 List:
References
50-272-90-14, 50-311-90-14, NUDOCS 9006200167
Download: ML18095A290 (2)


Text

APPENDIX A NOTICE OF VIOLATION Public Service Electric and Gas Company Salem Nuclear Generating Station, Units 1 and 2 Docket Nos.

50-272 50-311 License Nos. DPR-70 DPR-75 As a result of the inspection conducted from May 1-4, 1990, and in accordance with the NRC Enforcement Policy, (10 CFR 2, Appendix C), the following violation was identified:

Technical Specification 6.11 requires, in part, that procedures for personnel radiation protection shall be approved, maintained and adhered to for all operations involving personnel radiation exposure.

1.

Radiation Protection Procedure RP 201, Revision 2, Access Control Poini Management, requires, in part, i.n Section 7.2.1, that radiation protection personnel ensure that individuals entering the radiological controlled area (RCA) have read the applicable RWP and signed the RWP compliance agreement.

Contrary to the above, during the period April 24, 1990 through May 1, 1990, radiation protection personnel did not ensure that all.

personnel working under Revision 2 of RWP No. 901S00383 had read the RWP and signed the RWP compliance agreement.

Between April 24, 1990 and May 1, 1990, two individuals entered the RCA and worked under Revision 2 of RWP No. 901S00383 a total of 15 times and had not signed the RWP compliance agreement.

2.

Radiation Protection Procedure RP 204, Revision 2, Posting of Radiation Signs and Barriers, requires, in part, in Section 7.1.7, that each room or area in which radioactive material is used or stored and contains in excess of ten times the applicable quantities specified in 10 CFR 20 Appendix C be posted as 11 Caution - Radioactive Materials 11

  • Contrary to the above, on May 1, 1990 the entrance to a trailer within the protected area of Salem Station was not posted 11Caution - Radioactive Materials 11
  • The trailer contained in excess of 100 times the applicable quantities of radioactive materials specified in 10 CFR 20, Appendix C.

The above examples constitute a Severity Level IV violation.

(Supplement IV)

Pursuant to the provisions of 10 CFR 2.201, Public Service Electric and Gas Company is hereby required to submit to this office within thirty days of the date of the letter which transmitted this Notice, a written statement or explanation in reply, including: (1) the corrective steps which have been taken 9006200167 900611 PDR ADOCK 05000272 G

PNU OFFICIAL RECORD COPY CIR SALEM 90-14/14 - 0004.0.0 05/31/90

2 Appendix A and the.results achieved; (2) corrective* steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved.

Where good cause is shown, consideration will be given to extending this response time.

OFFICIAL RECORD COPY CIR SALEM 90-14/14 - 0005.0.0 05/31/90