ML18094B385

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs Re ESF Response Times for Main Steam Line Isolation Valves
ML18094B385
Person / Time
Site: Salem  
Issue date: 04/04/1990
From:
Public Service Enterprise Group
To:
Shared Package
ML18094B383 List:
References
NUDOCS 9004130161
Download: ML18094B385 (7)


Text

NLR-N90076 ATTACHMENT 3

,,,.-- -5'T>04T::::o H:* r- 'i'(l(>l+O*~*-

'\\

PDR ADOCK 05000272 P

PDC

TAB LE 3.3-5 (Continued)

ENGINEERED SAFETY FEAT~ES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION

3. Pressurizer Pressure-Low
a. Safety Injection (ECCS)
b. Reactor Trip (from SI}
c. Feedwater Isolation
d. Containment Isolation-Phase *A*
e. Containment Ventilation Isolation
f. Auxiliary Feedwater Pu~s
g. Service Water System 4..

Otfferei'ithl Pressure Between Steam Lines-High

a. Safety Injection (ECCS) be Reactor Trip (from SI) c
d. Containment Isolation-Phase *A*
e. Containment Yent11at1on Isolation
f. Auxiliary Feedw~ter Pu~s
g. Service Water System
s. Steam F 1 ow 1 n two Steam l1 nes
  • H19!! Coincident with T avg *-Law-LDW
a. Safety Injection (ECCS)
b. Reactor Trip (from SI)
c. Feedwat!r lsol1tion
d. Contaf n111nt Isolation.Phase *A*
    • Conta1n11ent-Yentil1tion Isolation
f. Au xi 11 ary FHdwater. Pull!ps
g. Service Water System
n. Steam L1 ne Iso 1at1 on SAW.
  • UHIT 1 3/4 3-28 RESPONSE T !ME IN SEC ON C5

~ 21.0(1)112.0(2)

< 2.0

-< 7.0

-! 18.0(2}

Not App 11cab1 e

< 60

-! 49.o(l)/13.o(2)

! 12.0(2}/22.0(3)

! 2.0

! 7.0

! 11.0(2)/27.0(3)

Not Applicable

< 60

-! 1J.0(2)/4a.o(3)

! 15.75(2)/25.75(3)

! 5.75

! 10.75

! 20.75(2)/30.75(3)

Not Applicable

! 61.75

< 15.75(2)/50.75(3)

!1e.1s_~

Amendment No. 84

TABLE 3.3-5 (Cont1nu@d)

ENGINEERED SAFETY FEATlRES RESPONSE TIMES INITIATING SIGMA LAND FUNCTION

6. Ste111 flow fn Two Stea* Lf nes-Hf gh Co1ne1dwrtt with Stea* Lf n1 Pressure-low
1. Safety InJect1on (ECCS)
b. R11ctor Trf p (fl"Oll SI)
c. Feedlf1ter Isol1tf on
d. Contaf ft91nt Isol1tton-Phas1 *A*
      • Cont11ft9'nt ~ent11;t!Gi'i liol1tion
f. Auxtl11ry Feedllfater Pull!ps
g. SerY1 c1 Water Syst*
h. Stu* Lfn1 Isol1t1on
7. Cont1i wnt Pressure-Hf gh-Hf gh
1. Contaf nmnt Spray
b. Cont11nmnt Isol1tton-Phas1 -a*
c. Stea* L1n1 Isolat1on
d. Contaf "91nt Fan Cooler
8. St11* Generator Water lavel-Htq!!-Hf sh
1. Turbf ne Trip -
b. Feedw1t1r Isolatton
9. St11* Generator Vat1r t.vel-1.ow*l.aw
    • Motor*Drf ven Auxtltary FH*ater Putlps(4)
b. Turbf n1*Dr1 v.n Auxf lfary Fftdw1ter Pumps (5)

SAi.EM

  • lltIT 1 3/4 3-29 RESPONSE T lME IN SECON OS

< 12.0(2)/22.0(3)

-< 2.0

..! 7.0

.! 11.0<2>121.0(3)

Not Applicable

< 60

~ 14.0(2)/48.0(3)

<a;; ry 10.0

< 45.0 Not *PP 11cab1 e

~ r.f-4-[io.o J

< 40.0

< 2.5

-< 11.0

< 60.0

.! 60.0 Amendment No.

84 I

PLANT SYSTEMS MAIN STEAM LINE ISOLATION VALVES LIMITING CONDITION FOR OPERATION _____________

~~

3.7.l.5 Each main steam line isolation valve shall be OPERABLE.

APPLICABILITY:

MODES 1, 2 and 3.

ACTION:

MODES 1 - With one main steam line isolation valve inoperable, POWER OPERATION may continue provided the.inoperable valve is either restored to OPERABLE status or closed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />; otherwise, be in. HOT SHUTDOWN within tha next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

MODES 2 - With one main steam line isolation valve inoperable, subsequent and 3 operation in MODES 1, 2 or 3 ~ay proceed provided;

a.

The isolation valve is maintained closed.

b.

The provisions of Specification 3.0.4 are not applicable.

Otherwise, be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

SURVEI°LL~NCE REQUIREMENTS 4.7.1.5 Each main steam line isolation valve shall be demonstrated OPERABLE by verifying full closure within ~econds when tested pursuant 'to Specification 4.0.5.

~

SAL2'!-UNrT 1 3/d. i-iO

)

TABLE 3.3-5 (Continued)

ENGINEERED SAFETY FEAT~ES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION

3. Pressu r'f zer Pressure-Low
a. Safety Injection (ECCS)
b. Reactor Trip (from SI)
c. Feedwater Isolation
d. Containment Isolation-Phase *A*
e. Containment Ventilation Isolation
f. Auxiliary Feedwater Pu111>s
g. Service Water System
4. Dffferentfal Pressure Between Steam Lines-High lo S~fety Injection (ECCS)
b. Reactor Trip (from SI)
c. Feedwater Isolation
d. Contain111ent Isolation-Phase *A~
e. Containment Vent11at1on Isolation
f. AuxiliJry Feedwater Puq>s
g. Service Water System
s. Steam Fl ow in two Steam Lines - High Cof nci dent with T avg -Low-Law
a. Safety Injection (ECCS)
b. Reactor Trip (from SI)
c. Feedwater Isolation
d. Contain111nt Isolation-Phase *A*
    • Contain.. nt Ventilation Isolation
f. Auxf 11ary FHdwater Pumps
g. Service Water System
h. Steam Line Isolatf on
  • UNIT 2 3/4 3-29 RESPONSE TIME IN SEC ON CS

! 27.0(l)/12.0(2)

! 2.0

! 7.0

! 18.0(2)

Not App 11cab1 e

< 60

-! 49.0(l)/13.0(2)

! 12.0(2)/22.0(3)

! 2.0 i 7.0

.! 17.0(2)/27.0(3)

Not App 1f cab 1 e

< 60

-! 13.0(2)/48.0(3}

< 15.75(2)/25.75(3)

-! S.75

! 10.75

! 20.75(2)/30.75(3)

Not Applf cable

! 61.. 75

< 15.75(2)/50.75(3)

~ 18. 75 ""@*;.fl Amendment No.

56

l>

..i TABLE 3.3-5 (Continued)

ENGINEERED SAFETY FEATURES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION

6.

Steam Flow in Two Steam Lines-High Coincident w~th Steam Line Pressure-Low

a.

Safety Injection (ECCS)

b.

Reactor Trip (from SI)

c.

Feedwater Isolation

d.

Containment Isolation-Phase "A"

e.

Containment Ventilation Isolation

f.

Auxiliary Feedwater Pumps

g.

Service Water System

h.

Steam Line Isolation

7.

Containment Pressure--High-High

a.

Containment Spray

b.

Containment Isolation-Phase 11811

c.

Steam Line Isolation

d.

Containment Fan Cooler

8.

Steam Generator Water Level--High-High

a.
  • Turbine Trip
b.

Feedwater Isolation

9.

Steam Generator Water Level --Low-Low

a.

Motor-Driven Auxiliary Feedwater Pumps(4)

b.

Turbine-Driven Auxiliary Feedwater Pumps(S)

RESPONSE TIME IH SECONDS i 12.0<2>122.oCJ)

ii 2.0
ii 7.0
ii 17.0<2>121.oCl)

Not Applicable

< 60

~ 14. 0<2> /48. 0<3>.

ii &rlt~

~

ii 45.0 Not Applicable
ii r.&-'(?o.o I

~ 40.0

~ 2.5

S 11. 0
ii 60.0
S 60.0 SALEM - UNIT 2 314-3-30

PLANT SYSTEMS MAIN STEAM LINE ISOLATION VALVES LIMITING CONDITION FOR OPERATION 3.7. 1.5 Each main steam line isolation valve shall be OPERABLE.

APPLICABILITY:

MODES 1, 2 and 3.

ACTION:

MODES 1 - With one main steam line isolation valve inoperable, POWER OPERATION may continue provided the inoperable valve is either restored to OPERABLE status or closed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />; Otherwise, be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

MODES 2 - Wi'th one main steam line isolation valve inoperable, subsequent and 3 operation in MODES 1, 2 or 3 may proceed provided;

a.

The isolation valve is maintained closed.

b.

The provisions of Specification 3.0.4 are not applicable.

Otherwise, be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.7.1.5 Each main steam line isolation valve shall be demonstrated OPERABLE by verifying full closure within~econds when tested pursuant to Specification 4.0.5.

~

SALEM - UNIT 2 3/4 7-10